1 Installation
1. Determine position in ceiling
where Fanlight is required to be
installed. (Do not install within
120cm of stove or inside a shower
recess). Be certain that the
installation area is not restricted
by roof beams above ceiling.
5. Remove light diffuser and
air-intake grille. Unscrew
the 3 screws on the lip of the
unit until the gap between the
toggles and inner lip of the
unit is greater than the width
of the Gyprock, or other ceiling
material. Fold these toggles in.
Push unit into hole.
A licensed electrician is required to connect this unit to the mains supply.
A lamp (B22 75W Max) is required for the R620 model (not supplied)
6. Turn the retention screws
clockwise. The toggles will splay
out. Tightening the retention
screws allows the toggles to
grip the ceiling material.
7. It is recommended that the
three toggles be checked for the
correct clamping by inspection
from above. You may now insert
a globe ≤ 75W into the R620
(not required for the R620LED)
8. Push grille into unit and click into
position. Assemble the diffuser
and round dust seal and twist
into position. To remove this
assembly for cleaning, simply
pull assembly downwards.
2. Use template provided to draw
a circle 300mm in diameter.
To do this insert a thumb tack
in hole at one end and insert
a pencil in the other hole and
scribe a circle.
3. Use electric jig saw or small
hand saw to cut out around this
line. Several holes drilled at a
point inside the circle provides
a convenient starting point for
cutting the panel out.
4. Remove the terminal cover and
wire according to the diagrams
in section 2. Option 1: This
method of wiring switches
fan and light on and off
simultaneously. Option 2:
Shows how to wire fan and
light separately. This allows the
light (or the fan) to be switched
on independently of the other.
Option 3: Shows the addition of
HPM Cat TX770/1RC time delay
mechanism.
Variable field of view
2 Switching arrangements
INSTALLATION/APPLICATION
Terminal block
& cover Motor
housing
Reflector
Dust seal
Retention
screws
Lampholder
Fan blade
Fan intake
grille
Light diffuser
Option 1: Fan and light switched together
Option 2: Fan and light switched separately
Option 3: Fan and light switched together with time
delay on fan after switch is turned off
Fan/Light switch
Fan switch
Light switch
1
1 2
C
Fan/Light Switch
HPM Cat. TX770/1RC
to light to fan
1 2
C
1
2
C
2
C
N L
FAN
A
A
LOOP
NEUTRAL
LIGHT
FAN
A
A
LOOP
NEUTRAL
LIGHT
FAN
A
A
LOOP
NEUTRAL
LIGHT
N L
N L
Double pole
disconnection
switch or 2 pin plug
Double pole
disconnection
switch or 2 pin
plug
Double pole
disconnection
switch or 2 pin plug
INSTALLATION/APPLICATION
Terminal block
& cover Motor
housing
Reflector
Dust seal
Retention
screws
Lampholder
Fan blade
Fan intake
grille
Light diffuser
Option 1: Fan and light switched together
Option 2: Fan and light switched separately
Option 3: Fan and light switched together with time
delay on fan after switch is turned off
Fan/Light switch
Fan switch
Light switch
1
1 2
C
Fan/Light Switch
HPM Cat. TX770/1RC
to light to fan
1 2
C
1
2
C
2
C
N L
FAN
A
A
LOOP
NEUTRAL
LIGHT
FAN
A
A
LOOP
NEUTRAL
LIGHT
FAN
A
A
LOOP
NEUTRAL
LIGHT
N L
N L
Double pole
disconnection
switch or 2 pin plug
Double pole
disconnection
switch or 2 pin
plug
Double pole
disconnection
switch or 2 pin plug
INSTALLATION/APPLICATION
Terminal block
& cover Motor
housing
Reflector
Dust seal
Retention
screws
Lampholder
Fan blade
Fan intake
grille
Light diffuser
Option 1: Fan and light switched together
Option 2: Fan and light switched separately
Option 3: Fan and light switched together with time
delay on fan after switch is turned off
Fan/Light switch
Fan switch
Light switch
1
1 2
C
Fan/Light Switch
HPM Cat. TX770/1RC
to light to fan
1 2
C
1
2
C
2
C
N L
FAN
A
A
LOOP
NEUTRAL
LIGHT
FAN
A
A
LOOP
NEUTRAL
LIGHT
FAN
A
A
LOOP
NEUTRAL
LIGHT
N L
N L
Double pole
disconnection
switch or 2 pin plug
Double pole
disconnection
switch or 2 pin
plug
Double pole
disconnection
switch or 2 pin plug
Variable field of view
3
4
Specifications
Product parts
R620 R620LED
Supply voltage: 240V a.c. 50Hz 240V a.c. 50Hz
Maximum power consumption: 113W 49W
Light: Consumption 75W (Max) 11W, not dimmable
Lumen output - 600 lumens
Temperature - 4000k (cool white)
Fan: Consumption 38W 38W
Airflow 300m3/hr 300m3/hr
Ceiling: Cut-out 300mm 300mm
Protrusion from ceiling: 90mm 90mm
Projection into ceiling: 130mm 130mm
Impeller diameter: 200mm 200mm
Weight (Normal): 3.0kg 3.0kg
INSTALLATION/APPLICATION
Terminal block
& cover Motor
housing
Reflector
- with lamp holder (R620), or
- with LED panel (R620LED)
Retention
screws
Fan blade
Fan intake
grille
Option 1: Fan and light switched together
Option 2: Fan and light switched separately
Option 3: Fan and light switched together with time
delay on fan after switch is turned off
Fan/Light switch
Fan switch
Light switch
1
1 2
C
Fan/Light Switch
HPM Cat. TX770/1RC
to light to fan
1 2
C
1
2
C
2
C
N L
FAN
A
A
LOOP
NEUTRAL
LIGHT
FAN
A
A
LOOP
NEUTRAL
LIGHT
FAN
A
A
LOOP
NEUTRAL
LIGHT
N L
N L
Light diffuser
and seal
assembly
Double pole
disconnection
switch or 2 pin plug
Double pole
disconnection
switch or 2 pin
plug
Double pole
disconnection
switch or 2 pin plug
Variable field of view
5 Warning
Warranty
HPM Legrand warrants this product for a period of 5 years from the
date of purchase. These goods come with guarantees that cannot
be excluded under the Australian and New Zealand Consumer
Laws. You are entitled to a replacement or a refund for a major
failure and for compensation for any other reasonably foreseeable
loss or damage. You are also entitled to have the goods repaired
if the goods fail to be acceptable quality and the failure does not
amount to a major failure. See the Warranty card enclosed with this
product for further details.
Customer Service
For all Customer Service and Technical Support
please call Monday to Friday during business hours.
HPM Legrand Australia
1300 369 777
www.hpm.com.au
HPM Legrand New Zealand
0800 476 009
www.hpm.co.nz
ABN: 31 000 102 661
LE05800ADB
a This product must be installed and used as per these instructions.
For indoor ceiling mount applications only.
b All wiring must be carried out by a licensed electrician.
c Means for disconnection must be incorporated in the fixed wiring in
accordance with the Wiring Rules.
d This product should only be cleaned with a damp cloth. Cleaning
agents and solvents should not be used.
e Ensure the fan is switched off from mains supply before removing
grill and diffuser for cleaning purposes.
f This appliance is intended for household use and similar purposes.
It is not suitable for use in an environment heavily-laden with dust.
Under these conditions the life of the fan motor can be significantly
reduced.
g This appliance is not intended for use by young persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised to
ensure that they do not play with the appliance.
h Airflows listed in this product indicate the product performance.
Refer to the BCA (Building Code of Australia), or similar, for the
appropriate number of room air changes / extraction rate required
for a particular installation.
i Ventilation products must have an adequate source of external air to
ensure rated performance can be achieved.
j This product contains no serviceable parts and no attempt should
be made to repair this product. If the product is faulty it should be
discarded.
k Severe electromagnetic interference from other products may cause
malfunction of this product.
l The material in this product may vary in colour from batch to batch.
Colour matching from one batch to another cannot be guaranteed.
m Electrical installations periodically receive transient over-voltages.
This product has been designed to minimise the effect of such
voltages on connected equipment. It may not give full protection for
extreme over voltage transients such as those resulting from a close
lighting strike.
n This product utilises intellectual property in the form of registered
designs, trademarks, and/or patents. Such intellectual property
remains the property of HPM Legrand in all cases.
o HPM Legrand reserves the right to modify the specifications of this
product at any time.

This manual suits for next models

1

Other HPM Fan manuals

HPM EFD01RDWE User manual

HPM

HPM EFD01RDWE User manual

HPM EFIL150SQWE User manual

HPM

HPM EFIL150SQWE User manual

HPM EFD01 Series User manual

HPM

HPM EFD01 Series User manual

HPM EF100SQWE User manual

HPM

HPM EF100SQWE User manual

HPM R620 Owner's manual

HPM

HPM R620 Owner's manual

HPM EF150SQWE User manual

HPM

HPM EF150SQWE User manual

HPM EFT150SQSWE User manual

HPM

HPM EFT150SQSWE User manual

HPM EF200SQ User manual

HPM

HPM EF200SQ User manual

Popular Fan manuals by other brands

Prominence Home Potomac 51639 owner's manual

Prominence Home

Prominence Home Potomac 51639 owner's manual

Guzzanti GZ-1401 instruction manual

Guzzanti

Guzzanti GZ-1401 instruction manual

Breez DELTA GBR50LED Installation and operating instructions

Breez

Breez DELTA GBR50LED Installation and operating instructions

Showa Denki KAIRYU instruction manual

Showa Denki

Showa Denki KAIRYU instruction manual

Rejuvenation Heron owner's manual

Rejuvenation

Rejuvenation Heron owner's manual

Habitat Watton manual

Habitat

Habitat Watton manual

Hunter 23262 Installating and operation manual

Hunter

Hunter 23262 Installating and operation manual

GreenTech FD-40F instruction manual

GreenTech

GreenTech FD-40F instruction manual

Hunter ashmont Owner's guide and installation instructions

Hunter

Hunter ashmont Owner's guide and installation instructions

Vents ICF Series user manual

Vents

Vents ICF Series user manual

Lasko Max Air 4821 operating manual

Lasko

Lasko Max Air 4821 operating manual

Compaq 2T-VCFAN-AA Installation information

Compaq

Compaq 2T-VCFAN-AA Installation information

Galletti UTN Series Technical manual

Galletti

Galletti UTN Series Technical manual

Vent-Axia Svensa installation guide

Vent-Axia

Vent-Axia Svensa installation guide

Aereco CONNECT WP120 Technical manual

Aereco

Aereco CONNECT WP120 Technical manual

Jaga Briza 22 installation instructions

Jaga

Jaga Briza 22 installation instructions

Lasko W16900 operating manual

Lasko

Lasko W16900 operating manual

Craftmade MN44FB4 installation guide

Craftmade

Craftmade MN44FB4 installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.