Notes:
The specification may be changed for product improvement, please refer to the nameplate of
product.
MAINTENANCE
To protect the paintwork, avoid leaning or putting objects on the device. External heat pump
parts can be wiped with a damp cloth and domestic cleaner. (Attention: Never use cleaning
agents containing sand, soda, acid or chloride as these can damage the surfaces.)
To prevent faults due to sediments in the titanium heat exchanger of the heat pump, ensure
that the heat exchanger cannot be contaminated (water treatment and filter system necessary).
In the even that operating malfunctions due to contamination still occur, the system should be
cleaned as described below.
(Warning: the fins on the finned tube heat exchanger are sharp-edged --- danger of being cut!)
Cleaning the pipe system in the heat exchanger
Contamination in the pipes and heat exchanger can reduce the performance of the heat
pump’s titanium heat exchanger. If this is the case, the pipe system and heat exchanger must
be cleaned by a technician.
Use only pressurized drinking water for cleaning.
Cleaning the air system
The finned heat exchanger, ventilator and condensate outflow should be cleaned of
contaminants (leaves, twigs, etc.) before each new heating period. These types of
contaminants can be manually removed using compressed air or by flushing with clean water.
It may be necessary to remove the device cover and air inlet grid first.
Attention: Before opening the device, ensure that all circuits are isolated from the power
supply.
To prevent the evaporator and the condensate tray from being damaged, do not use hard or
sharp objects for cleaning.
Under extreme weather conditions (e.g. snow drifts), ice may form on the air intake and
exhaust air outlet grids. If this happens, the ice must be removed in the vicinity of the air intake
and exhaust air outlet grids to ensure that the minimum air flow rate is maintained.
Winter Shutdown/Lay-up
If there is a chance of frost after the bathing-season has ended when the swimming pool
heating is switched off and the external temperature is expected to drop below the operating
limit, the water circuit of the heat pump should be completely drained. Otherwise, suitable
constructional measures should be taken by the customer to protect the heat pump against
damage from frost.