ICWUSA TITAN ELITE Instruction sheet

TITAN ELITE CEILING & WALL MOUNT INsTALL
TITAN ELITE INSTALLATION - 09/01/16 pjmPage 1 of 4
DO NOT use power tools to assemble or
adjust the arm. Use hand tools ONLY.
IMPORTANT
ICW recommends wood or metal stud mounting only.
MAXIMUM LOAD CAPACITY:
28 LBS (12.7 KG)
•Do not attempt to adjust the arm until all components
are mounted (monitor, keyboard, etc.)
•Arm must be completely horizontal (extended)
before adjusting the arm’s tension. Failure to do so will
damage the arm and void the warranty.
•NEVER loosen or remove any of the shoulder
bolts. Doing so will cause the arm to immediately
come apart with tremendous force, and could cause
serious injury.
• If equipment requiring AC power is mounted to this unit,
haveacertiedelectricianinspecttheinstallation.
• Failure to install this unit according to these instructions
will void all ICW warranties. If installed incorrectly, ICW
is not liable for any damage or injury caused by the unit.
The Elite arm contains high pressure gas
springs. The following cautions MUST be
observed to avoid serious injury.
DANGER!
MOUNT sQUARE CEILING PLATE
Loosen the set screw
in ceiling plate before
attaching extension pipe.
Using four 1/4 x 2” lag bolts
provided in hardware bag,
secure ceiling plate to a solid
wood surface or ceiling joist.
Use square pattern or inline
pattern. Be sure to use all four
bolts.
Run wires through center hole
or wire management port.
Loosen set screw BEFORE
attaching pipe. Screw
extension pipe into ceiling
plate, then tighten set screw.
Wire management holes
MOUNT INLINE CEILING PLATE
Loosen the set screw
in ceiling plate before
attaching extension pipe.
Firmly secure ceiling mount
to solid ceiling joist using
four #14 wood screws found
in hardware bag. Be sure
mount is level.
Loosen set screw BEFORE
attaching pipe. Screw extension pipe into ceiling
plate, then tighten set screw.
Ceiling Mount
Wall Mount
MOUNT WALL EAR & PLATE
Using the 3/16 hex key
provided, attach wall plate
to ear with four 1/4-20
screws provided.
Locate stud and mark top
hole, drill 11/64 pilot hole
and insert #14 screw and
tighten slightly. Using a
level, mark lower holes and
drill pilot holes. Insert #14
screws and, with unit level,
tighten all screws.
NOTE: ICW supplies #14
wood screws. If installing
onto metal studs, you will
need to replace with proper
metal stud fasteners.
Thread arm onto extension pipe
andtighten.AFTERarmisrmly
attached, tighten set screw with
5/32 hex key.
DO NOT loosen lower, smaller screw
without instructions from ICW.
ATTACH ARM TO EXTENsION PIPE
Set
screw

TITAN ELITE CEILING & WALL MOUNT INsTALL
TITAN ELITE INSTALLATION - 09/01/16 pjmPage 2 of 4
MONITOR TILT, ROTATION & ADJUsT MONITOR DEPTH
MONITOR TILT
& ROTATE
Gently hold sides
of monitor. Tilt and
rotate to desired
position with ball
VESA.
ADJUST
MONITOR
DEPTH
Loosen the
adjustment
knob, move
the Paralink
forward or
back, then
re-tighten
the knob.
Adjustment
Knob
ATTACH VEsA (PARALINk)
Attach VESA to
monitor using
four 4mm screws
in the hardware
bag.
Mount the VESA
assembly by
screwing the
knob through
the rail into the
VESA.
Attach Monitor - Paralink
Attach Keyboard Tray
IF ATTACHING TO ULTRA FLIP-UP IF ATTACHING TO PARALINk
ATTACH FLIP UP
• Remove screws from
drop extension using
5/32” hex key.
• Align holes in keyboard
tray with screw holes in
drop extension.
• Attach keyboard tray
using the provided
screws.
ATTACH PARALINk
• Remove beauty cap on
Paralink.
• Remove screw using 3/16”
hex key.
• Slide keyboard tray into
Paralink.
• Replace screw and tighten.
• Replace beauty cap.
Beauty cap
Screw
Attach the Paralink
Keyboard Mount to the
Monitor Mount by using
the 3/8-16 screw and
lock washer provided.
ATTACH PARALINk kEYBOARD TO MONITOR
ADJUsT BALL VEsA TENsION & HEIGHT
Pivot tension
adjustment screws
Use the slider knob
to loosen the slider
to adjust the height
of the monitor on the
Paralink.
Adjust the pivot tension
of the ball by gently
and evenly tightening
or loosening the four
screws on the back of
the ball VESA.
Slider knob

TITAN ELITE CEILING & WALL MOUNT INsTALL
TITAN ELITE INSTALLATION - 09/01/16 pjmPage 3 of 4
Attach QuickLink & Monitor Cord Management - Wall Mount
REMOVE ELITE ARM COVERs
END COVERS
Remove the end covers by
unscrewing the two 3/4” long
10-24atheadscrewsusinga
Phillips head screwdriver.
TOP COVER
Remove the long arm cover
by unscrewing the two 1/4”
long6-32atheadscrewsin
the center of the cover using
a Phillips head screwdriver. If
you use a power tool, be very
careful not to strip the screws.
The arm needs to be in a
vertical position to remove the
long top cover.
MANAGE CORDs THROUGH ARM - WALL MOUNT
Feed monitor and other cords and any other cords down
through opening in wall mount. Slip all cords through Titan
arm, out through end cap and into the back of the Elite arm.
When running cords through arm, keep them all to one side
of bolts at Titan arm joints. Pass cords through holes in Elite
arm end covers. Reassemble arm and reattach covers.
NOTE: When measuring for length of cords, be sure
to allow enough extra cord to accommodate tilt and
rotation of monitor.
NOTE: CORDS CAN BE DAMAGED IF JOINTS ARE
ROTATED MORE THAN 360 DEGREES.
USE ROTATION
STOP PINS TO AVOID DAMAGE.
Rotation
Bearing
Rotation
Bearing
End cap
End cover
End cover
Top cover
Titan Arm
Wire Management Detail
ADJUsT QUICkLINk TILT
QuickLink
buttons
Pivots
Use the under-monitor handle
to rotate, tilt and swivel the
monitor to desired position.
Increase range of motion by
depressing buttons on back
of QuickLink. Each button
provides 90° of adjustment
for its corresponding pivot.
Depressing both buttons
at once provides 180° of
adjustment.
ATTACH QUICkLINk TO ARM
9/16 wrench
Nut
Remove nut from bolt
on QuickLink. Attach
QuickLink to arm. Thread
nut onto bolt through front
of arm assembly. Tighten
bolt with provided 9/16”
wrench.
ATTACH VEsA AND HANDLE TO MONITOR
Using a Phillips
screw driver, attach
the VESA plate
to the back of the
monitor using four
4mm screws in the
hardware bag.
Attach handle to
VESA plate.

TITAN ELITE CEILING & WALL MOUNT INsTALL
TITAN ELITE INSTALLATION - 09/01/16 pjm
Bearing
Ceiling
pipe
End cap
End cover
End cover
Top cover
End cap
Page 4 of 4
Cord Management - Ceiling Mount
ADJUsT ARM REsIsTANCE
Extend the arm
straight out as shown
before adjusting the arm’s
resistance. Be sure all equipment
is mounted on the arm before
adjusting. Use the T-handle provided
to adjust the arm’s resistance.
DO NOT USE POWER TOOLS TO ADJUST.
MANAGE CABLEs THROUGH ARM - CEILING MOUNT
REATTACH ARM COVERs
TOP COVERS:
Reattach the long arm covers by replacing the two
1/4”long6-32atheadscrewsinthecenterofthe
cover using a Phillips head screwdriver.
CENTER COVER:
Reattach the center cover by replacing the four 3/4”
long10-24atheadscrewsusingaPhillipshead
screwdriver.
END COVERS:
Reattach the end covers by replacing the two 3/4”
long10-24atheadscrewsusingaPhillipshead
screwdriver.
Torque Chart- In/lbs 2/23/2016
Minimum torque values Monitor Mount
Arm
Base
Mount Arm Joint Paralink EV710 Ultra
021-021-021etilE
021-021021021etilE2T
Titan (T2) 120 120 120 - 120
02158021021021artlU
UL180 / UL182 120 120 - 85 -
MD Arm 140 - 120 - 120
Feed monitor and other cords and any other cords down
through the ceiling extension pipe. Slip all cords through
Titan arm, out through end cap and into the back of the
Elite arm. When running cords through arm, keep them
all to one side of bolts at Titan arm joints. Pass cords
through holes in Elite arm end covers. Reassemble arm
and reattach covers.
NOTE: When measuring for length of cords, be
sure to allow enough extra cord to accommodate
tilt and rotation of monitor.
NOTE: CORDS CAN BE DAMAGED IF JOINTS
ARE ROTATED MORE THAN 360 DEGREES.
USE ROTATION STOP PINS TO AVOID DAMAGE.
ADJUsT ROTATION sTOPs
Rotation limits for the
arm are set by placing
stop pins in the holes
where you want the
arm to stop. The stop
pins can be removed
and set by hand.
Rotation
Limiter Ring
Stop Pin
Other ICWUSA Rack & Stand manuals
Popular Rack & Stand manuals by other brands

Konig & Meyer
Konig & Meyer 23856 INFORMATION FOR USE

Audio Precision
Audio Precision RAK-APX instructions

Muscle Rack
Muscle Rack ACR3296B Use and care guide

Konig & Meyer
Konig & Meyer 11912 manual

Speaka Professional
Speaka Professional SP-AWR-100 operating instructions

Philips
Philips SDW1410 Specification sheet