Ideal Air 700026 User manual

SPLIT-TYPE FOUR-WAY CASSETTE TYPE
ROOM AIR CONDITIONER
USER MANUAL
Inside you will find helpful hints on how to use and maintain your air conditioner properly.
Just a little preventative care on your part can save you a great deal of time and money over the life
of your air conditioner. Before operating this product, please read the instructions carefully and
save this manual for future use.
#700026 • #700027 • #700028 • #700029
PRO |DUAL MINI-SPLIT
INDOOR | CEILING MOUNT

READ THIS MANUAL
CONGRATULATIONS...
Please read through these instructions before you start the installation process. Improper installation can
cause damage to the unit, your personal property, and also poses a personal safety hazard.
on your purchase of Ideal Air’s Pro | Dual Mini-Split, indoor unit. We’re proud to offer this product and
believe it’s the very best in its class.
2
SAFETY PRECAUTIONS..................................................................................................................3
MANUAL OPERATION ....................................................................................................................5
ADJUSTING AIR FLOW DIRECTION............................................................................................5
MAINTENANCE ................................................................................................................................6
AIR CONDITIONER OPERATIONS AND PERFORMANCE .....................................................8
INSTALLATION..................................................................................................................................9
TROUBLES AND CAUSES ..............................................................................................................9
TROUBLES AND CAUSES (CONCERNING REMOTE CONTROL).......................................10
MATCH UP CHART.........................................................................................................................11
CONTENTS

3
SAFETY PRECAUTIONS
READ SAFETY PRECAUTIONS BEFORE INSTALLATION:
Incorrect operation due to ignoring instructions can cause serious damage or injury.
The seriousness of potential damage or injuries is classified as either a WARNING or CAUTION.
WARNING
DO NOT attempt to service the unit yourself. This unit has no user
serviceable components. Opening or removing the cover will expose you
to dangerous voltage.
Never put hands or objects into the air outlet of indoor or outdoor units.
These units are installed with a fan running at high speed. To touch the
moving fan will cause serious injury.
DO NOT attempt to install this unit by yourself. This unit requires
installation by qualified professionals.
Ventilate the room regularly while the air conditioner is in use, especially
if there is also a gas appliance in use in this room, failure to follow these
directions may result in a loss of oxygen in the room.
To prevent electric shock, turn off the power or disconnect the power
supply before beginning any cleaning or other routine maintenance.
Follow the directions for cleaning in the user manual.
DO NOT use liquid cleaners or aerosol cleaners, use a soft and dry cloth
for cleaning the unit. To avoid electric shock, never attempt to clean the
units by spraying with water.
DO NOT use caustic household drain cleaners in the unit. Drain cleaners can
quickly destroy the unit components (drain pan and heat exchanger coil etc).
This symbol indicates that ignoring
instructions may cause damage to
your unit, or other property, serious
injury or death.
This symbol indicates that ignoring
instructions may cause moderate
injury to you, or damage to your
unit or other property.
WARNING CAUTION
Danger
No
Thinner
No
Household
Drain
Cleaner
NOTE:
For proper performance, operate the unit in temperature and humidity
ranges indicated in this owner's manual. If the unit is operated beyond
these conditions, it may cause malfunctions of the unit or dew dripping
from the unit.
CAUTION

4
NAMES AND FUNCTIONS
2
6
7
4
3
8
5
1
9
Indoor Unit
Outdoor
Unit
Inlet
Outlet
12 13 14 15
11
10
Control board
Manual
OPERATION
TIMER
DEF./FAN.
ALARM
12
12
13
13
14
14
15
15
11
11
10
10
10
SET
OPERATION
TIMER
DEF./FAN.
ALARM
NOTE:
These three indication lamps flash in
cycles when solar PV ECO function is
activated. (Applicable to the unit adopts
solar photovoltaic system only.)
FUNC
Indoor Unit
Air outlet
Drain hose
Drain Pump (Internal installed), water drain from indoor unit.
Infrared Signal receiver
Timer indicator
Alarm indicator
Defrost indicator heating/cooling type or fan indicator (cooling
only type)
Outdoor Unit
Vertical louver
Manual button/SET button
Remote Control
Connecting pipe
Run lamp
1
7
10
4
9
13
15
2
3
11 12
14
8
5
6
Air Inlet (Air filter installed inside to prevent the dust)
NOTE:
This chart is based on 18000BTU/h type. So, a little differences may exist
on the outlook and functions from yours.
FOUR-WAY CASSETTE (SLIM) TYPE

5
TEMPORARY
BUTTON
MANUAL OPERATION
CEILING AND FLOOR
This function is used to operate the unit temporarily in case you misplace the remote control or its
batteries are exhausted. Two modes including AUTO and FORCED COOL can be selected through
the TEMPORARY BUTTON on the air-in grill control box of the indoor unit. Once you push this
button, the air conditioner will run in such order: AUTO, FORCED COOL, OFF, and back to AUTO.
• AUTO: The OPERATION lamp is lit, and the air conditioner will run under AUTO mode. The remote
control operation is enabled to operate according to the received signal.
• FORCED COOL: The OPERATION lamp flashes, the air conditioner will turn to AUTO after it is enforced to
cool with a wind speed of HIGH for 30 minutes. The remote control operation is disabled.
• OFF: The OPERATION lamp goes off. The air conditioner is OFF while the remote control operation
is enabled.
FOUR-WAY CASSETTE
This function is used to operate the unit temporarily in case you misplace the remote control or its
batteries are exhausted. Two modes including AUTO and MANDATORY COOL can be selected through
the TEMPORARY BUTTON on the air inlet grill control box of the indoor unit. Once you push this
button, the air conditioner will run in such order: AUTO, MANDATORY COOL, OFF, and back to AUTO.
• AUTO: The OPERATION lamp is lit, and the air
conditioner will run under AUTO mode. The
remote control operation is enabled to
operate according to the received signal.
• MANDATORY COOL: The OPERATION lamp
flashes, the air conditioner will turn to AUTO
after it is enforced to cool with a wind speed
of HIGH for 30 minutes. The remote control
operation is disabled.
• OFF: The OPERATION lamp goes off. The air
conditioner is OFF while the remote control
operation is enabled.
ADJUST IT UP AND DOWN
ADJUSTING AIR FLOW DIRECTION
CASSETTE TYPE
While the unit is in operation, you can adjust the air flow louver to change the flow direction and naturalize
the room temperature evenly. Thus you can enjoy it more comfortably.
• Set the desired air flow direction. Push the SWING button to adjust the louver to the desired position
and push this button again to maintain the louver at this position.
• Adjust the air flow direction automatically. Push the SWING button, the louver will swing automatically.
While this function is set, the swing fan of the indoor unit runs; otherwise, the swing fan doesn't run. The
swing scale of every side is 300º. When the air conditioner isn't in operation the SWING button will be disabled.

6
MAINTENANCE
Before you clean the air conditioner, be sure to disconnect the power supply.
DUCT AND CEILING TYPE
The following is how to adjust air flow direction when air outlet part (sold separately) is used with the
indoor unit.
• Use a dry cloth to wipe the indoor unit and remote control.
• A cloth dampened with cold water may be used on the indoor unit if it is very dirty.
• Never use a damp cloth on the remote control.
• DO NOT use a chemically-treated duster for wiping or leave such material on the unit for long, because it
may damage or fade the surface of the unit.
•
DO NOT use benzine, thinner, polishing powder, or similar solvents for cleaning. These may cause the plastic
surface to crack or deform.
CLEANING THE INDOOR UNIT AND REMOTE CONTROL
COOLING
To effectively cool
the whole room,
please set the
louver so that the
air can come out
horizontally.
HEATING
To effectively heat the
bottom of the room,
Please set the louver
so that the air can
come out downwards.
WARNING
CAUTION
If you do not plan to use the unit for at least 1 month.
• Operate the fan for about half a day to dry the inside of the unit.
• Stop the air conditioner and disconnect power.
• Remove the batteries from the remote control.
Before you clean the air conditioner, be sure to disconnect the power supply.
CHECKS BEFORE OPERATION
• Check that the wiring is not broken off or disconnected.
• Check that the air filter is installed.
• Check that the outdoor unit air outlet or inlet is not blocked.
CAUTION
CLEANING THE AIR FILTER
• The air filter can prevent the dust or other particulate from going inside. In case of blockage of the filter,
the working efficiency of the air conditioner may be greatly decreased. Therefore, the filter must be
cleaned once every two weeks.
• If the air conditioner is positioned in a dust place, the cleaning frequency of the air filter must be increased.
• If the accumulated dust is too heavy to be cleaned, please replace the filter with a new one (replaceable
air filter is an optional fitting).

7
The control box cables, which are originally connected with the main body electrical terminators must be
pulled off before doing as indicated above.
CAUTION
2 Take out the air-in grill (together with the air filter shown in Sketch B) Pull the air-in grill down at 45˚ and
lift it up to take out the grill.
3 Dismantle the air filter.
4 Clean the air filter (Vacuum cleaner or pure water may be used to clean the air filter. If the dust
accumulation is too heavy, please use soft brush and mild detergent to clean it and dry out in cool place).
CASSETTE TYPE
1 Open the air-in grill: Push the grill switches towards the middle simultaneously as indicated in sketch A.
Then pull down the air-in grill.
A
B
CEILING TYPE
1 Open the air-in grill: Push the grill switches towards the middle simultaneously as indicated in following
figure sketch. Then pull down the air-in grill.
The control box cables, which are originally connected with the main body electrical terminators must be
pulled off before doing as indicated above.
2 Take out the air-in grill.
3 Dismantle the air filter.
4 Clean the air filter (Vacuum cleaner or pure water may be used to clean the air filter. If the dust
accumulation is too heavy, please use soft brush and mild detergent to clean it and dry out in cool place).
CAUTION
Clip
Open<
Fig. 1
Fig. 2

8
DO NOT dry out the air filter under direct sunshine or with fire.
5
Re-install the air filter.
6
Install and close the air-in grill in the reverse order of step 1 and 2 and connect the control box cables to the
corresponding terminators of the main body.
a) The air-in side should face up when using vacuum cleaner (See FIG. 1).
b) The air-in side should face down when using water (See FIG. 2).
CAUTION
NOTE:
High-static Pressure Parvis Split Type has no air filter.
AIR CONDITIONER OPERATIONS
AND PERFORMANCE
THREE-MINUTE PROTECTION FEATURE
A protection feature prevents the air conditioner from being activated for approximately 3 minutes
when it restarts immediately after operation.
POWER FAILURE
Power failure during operation will stop the unit completely.
• The OPERATION lamp on the indoor unit will start flashing when power is restored.
• To restart operation, push the ON/OFF button on the remote control.
• Disconnect the unit with the power and then connect the unit with the power again.
• Push the ON/OFF button on the remote control to restart operation.
AIR CONDITIONER OPERATING CONDITIONS
For proper performance, run the air conditioner under the following temperature conditions:
Mode Cooling operationHeating operation Drying operation
Temperature
1. If air conditioner is used outside of the above conditions, certain safety protection features
may come into operation and cause the unit to function abnormally.
2. Room relative humidity less than 80%. If the air conditioner operates in excess of this
figure, the surface of the air conditioner may attract condensation. Please setthe vertical
air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.
3. Optimum performance will be achieved within these operating temperature.
Room temperature
Outdoor temperature
NOTE:
17 32
62 90 0 30
32 86
-7 24
20 76
18 43
64 109
-7 43 20 109
For the models with low
temperature cooling system
18 52 64 126
For special tropical models
(For special tropical models)
OO
OO
17 C~ 32 C/ 62 F~ 90 F
OO
OO
18 C~ 43 C/64 F~109F
OO
OO
18 C~52 C/64 F~126 F

9
SPECIAL FUNCTIONS: REFRIGERANT LEAKAGE DETECTION (OPTIONAL):
With this new technology, the display area will appear EC (if applicable) and the LED
indication lamps continue flashing when the outdoor unit detects refrigerant leakage.
SPECIAL FUNCTIONS: LOUVER ANGLE MEMORY FUNCTION (OPTIONAL):
For some models, the machine is specially designed with louver angle memory function. Power failure
during operation or pressing the ON/OFF button on the remote control will stop the unit completely.
When the power restores or pressing the ON/OFF button on the remote control again, the unit restarts
automatically with the previous open angle of the horizontal louver by the memory function. So we
strongly recommend that the open angle of the horizontal louver should not be set too small, in case the
condensed water forms and drops from the horizontal louver. Press the MANUAL CONTROL BUTTON and
the open angle of the horizontal louver will be restored to the standard angle.
INSTALLATION
LOCATION
• During cooling operation, the air conditioner will
dry the room air, so please fix a pipe to drain all
the water away from the air conditioner.
• Please keep the indoor unit more than 1m/40"
away from the TV set and the radio in order to avoid
the picture and noise interference.
• Powerful radio transmitters or any other devices
radiating high frequency radio waves can cause
the air conditioner to malfunction.
• If the air conditioner operates in an atmosphere
containing oils (machine oil), salt (near a coastal
area), sulfide gas (near a hot spring), etc., such
substances may lead to failure of the air conditioner.
BE CAREFUL OF NOISE OR VIBRATIONS
• Please install the unit in a stable place to avoid
noise or vibrations.
• Locate the outdoor unit where noise emitted by it or
hot air from its air outlet will not cause nuisance
to your neighbors.
• If the air conditioner sounds abnormal during
operation, contact the service professional that
installed your unit or Ideal-Air
TM
tech support.
WIRE
• To avoid electric shock, please link the air
conditioner with the ground. The plug in the air
conditioner has joined the ground wiring, please
don't change it freely.
• Don't pull the power cord.
• When linking the air conditioner with the ground,
observe the local rules.
•
If you want to change the power wiring, please contact
a certified electrician.
RELOCATION
If you move out or if it is desired to relocate
the air conditioner, consult an HVAC technician,
because special certification is required to
withdraw Freon, purge air and perform other
operations that are necessary.
TROUBLES AND CAUSES
RECHECK
Inoperative
• The power fuse is blown or the circuit breaker has
been tripped.
• The batteries in the remote control are exhausted.
• The timer is set does not cool or heat well.
• The air inlet or outlet of the outdoor unit is blocked.
• Doors or windows are open.
• The air filter is clogged with dust.
• The louver is not at the correct position.
• The fan speed is set too low.
• The temperature setting is too high or too low.
THESE ARE NOT FAILURES
Room air is smelly – A bad odor comes from the air
conditioner.
• Smells in the wall, carpet, furniture, clothing, or
furs, are coming out. A white mist of chilled air or
water is generated from the outdoor unit.
Before you ask for servicing or repairs, check the following points.

bk
TROUBLES AND CAUSES
(CONCERNING REMOTE CONTROL)
Before you ask for servicing or repairs, check the following points.
If any of the following conditions occur, stop the air conditioner immediately, cut all power to the system,
and contact a service technician:
• The indicator lamps flash rapidly (five times per second), you disconnect the unit with the power and then
connect the unit with the power again after two or three minutes but the lamps still flash.
• Switch operations are erratic.
• The fuse is blown frequently or the circuit breaker is tripped frequently.
• Foreign matter or water has fallen inside the air conditioner.
• Any other unusual condition is observed.
CAUTION
The Transmission Indicator " " Never Comes On
The Display Never Comes On
Symptoms
Symptoms
Causes
Causes
Reason and Disposal
Reason
The remote control signal is
not transmitted even when
the ON/OFF button is pushed.
The TEMP. indicator does
not come on.
Check whether the batteries
in the remote control are
exhausted.
Check whether the MODE
indicated on the display is
"FAN ONLY".
The remote control signal is
not transmitted, because the
power supply is off.
The temperature cannot be
set during fan only operation.
The Display Goes Off
Symptoms Causes Reason
The indication on the display
disappears after a lapse of
time.
The ON TIMER indicators
go off after a lapse of certain
time.
Check whether the timer
operation has come to an
end when the OFF TIMER
is indicated on the display.
Check whether the timer
operation is started when
the ON TIMER is indicated
on the display.
The air conditioner operation
stops since the set time
elapsed.
When the time set to start the
air conditioner is reached, the
air conditioner will automatically
start and the appropriate
indicator will go off.
The Signal Receiving Tone does Not Sound
Symptoms Causes Disposal
No receiving tone sounds
from the indoor unit even
when the ON/OFF button is
pushed.
Check whether the signal
transmitter of the remote
control is properly directed
to the receiver of the indoor
unit when the ON/OFF button
is pushed.
Direct the signal transmitter of
the remote control to the
receiver of the indoor unit, and
then repeatly push the ON/
OFF button twice.
Buttons on the remote
controller don't work. Press Reset button.
Setting Change is Impossible
Symptoms Causes Reason and Disposal
The fan speed can not be
changed.
Check whether the MODE
indicated on the display is
"AUTO"
Check whether the MODE
indicated on the display is
"DRY"
When the automatic mode is
selected, the air conditioner
automatically selects the fan
speed.
When dry operation is selected,
the air conditioner automatically
select the fan speed. The fan
speed can be selected during
"COOL" and "FAN ONLY", and "HEAT"

bl
Malfunction
1
2
3
4
5
6
7
8
9
10
12
13
14
15
16
17
18
19
20
21
22
23
24
25
11
Indoor EEPROM error
Water-level alarm malfunction
Indoor room temperature sensor
open circuit or short circuit
Indoor fan speed malfunction
Communication malfunction
between two indoor units (for
twins model)
Refrigerant leakage detection
malfunction
Evaporator coil temperature
sensor open circuit or short circuit
Other malfunction of twins model
Outdoor room temperature sensor
open circuit or short circuit
Current overload protection
High/Low voltage protection
Inverter module IPM protection
Lifting panel is not closed
Lifting panel malfunction
Lifting panel communication
checking channel is abnormal
T2b sensor error
Outdoor EEPROM error
Outdoor fan speed malfunction
(Only for DC fan motor)
Discharging air temperature
sensor error
Outdoor condenser pipe
temperature sensor error
E0.
E1.
E3.
E4.
E5.
EC.
EE.
E8.
E9.
F0.
F1.
F2.
F3.
F4.
F5.
F6.
F7.
F8.
F9.
P0.
P1.
P2.
P3.
P4.
P5.
ON.
ON.
ON.
ON.
ON.
ON.
ON.
ON.
ON.
ON.
Flash.
Flash.
Flash.
Flash.
Flash.
Flash.
High temperature protection of
compressor top
Mode conflict
Compressor drive error
Outdoor low temp. Protection
NO
Display (nixie tube)timer lamp running lamp (flashes per second)
Communication malfunction
between indoor and outdoor units
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
1
2
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
1
10
1
2
3
4
5
6
THE FOLLOWING DISPLAYS INDICATE AN ERROR OR PROBLEM:
The displayed error code differs from appliance to appliance. The actual display of the indoor unit shall prevail.

IMPORTANT
1-877-943-3251
Product not working properly?
Contact Ideal-AirTM support directly
at support@ideal-air.com or call
For answers to most common questions and a complete
technical support library please visit www.ideal-air.com
All design and specifications herein are subject to change without
notice for product improvement. Contact Ideal-AirTM for details,
updates and other information.
DO NOT return this product
to the store where you
purchased it.
Other manuals for 700026
1
This manual suits for next models
3
Table of contents
Other Ideal Air Air Conditioner manuals

Ideal Air
Ideal Air 700875 User manual

Ideal Air
Ideal Air IAH24MD-D3DNA3D User manual

Ideal Air
Ideal Air 700019 User manual

Ideal Air
Ideal Air Portable Air Conditioner User manual

Ideal Air
Ideal Air PRO User manual

Ideal Air
Ideal Air IAH36LB-D3DNA3D User manual

Ideal Air
Ideal Air 700890 User manual

Ideal Air
Ideal Air 700021 User manual

Ideal Air
Ideal Air 700485 User manual

Ideal Air
Ideal Air 700026 User manual