IDEAL TILT-A WAY HYJG 1 Programming manual

TILT-A WAY
HYJG 1
VERTICAL PIVOT GATE
SINGLE PHASE VAC, THREE PHASE VAC
AND 24 VDC
Vehicular Class
I, II, III, and IV
Operators & Parts Manual
NOTE: WHEN ORDERING PARTS, PLEASE HAVE YOUR SERIAL NUMBER
TO ENSURE THE CORRECT PARTS ARE SENT TO YOU.
Manual subject to change with out notice.
Ideal Manufacturing, Inc. • 2011 Harnish Blvd. • Billings, MT 59101
P (406) 656-4360 • F (406) 656-4363
$20.00 USD Funds Date: 1/10/2020 SERIAL NUMBER _______________________________

TABLE OF CONTENTS
DESCRIPTION
PAGE #
WARRANTY
SAFETY INFORMATION
/ CLASS OF VEHICULAR GATE / PROTECTION AGAINST ENTRAPMENT
1
GATE SPECIFICATIONS
2
ALTERNATE FENCE SCHEMES
3
GENERAL INFORMATION
4
USER INTERFACE BOARD GENERAL INFORMATION
5
LOGIC B
OARD GENERAL INFORMATION
6
MOTOR CONTROL BOARD GENERAL INFORMATION
7
ELECTRICAL DIAGRAM
24 VOLT DC
8, 9
MASTER GATE ELECTRICAL DIAGRAM
24 VOLT DC
10
SLAVE GATE ELECTRICAL DIAGRAM
24 VOLT DC
11
ELECTRICAL DIAGRAM
SINGLE
PHASE 208 / 240 VAC
12,13
MASTE
R GATE ELECTRICAL DIAGRAM
SINGLE
PHASE 208 / 240 VAC
14
SLAVE GATE ELECTRICAL DIAGRAM
SINGLE
PHASE 208 / 240 VAC
15
ELECTRICAL DIAGRAM THREE PHASE 208 / 240 VAC
16, 17
MASTER GATE ELECTRICAL DIAGRAM THREE PHASE 208 / 240 VAC
18
SLAVE GATE ELECTRICAL DI
AGRAM THREE PHASE 208 / 240 VAC
19
ELECTRICAL DIAGRAM THREE PHASE 480 VAC
20,21
MASTER GATE ELECTRICAL DIAGRAM THREE PHASE 480 VAC
22
SLAVE GATE ELECTRICAL DIAGRAM THREE PHASE 480 VAC
23
REFLECTIVE TYPE PHOTO EYE DIAGRAM
24
SAFETY WARNING LIGHT DIAGRA
M
25
ELECTROMAGNETIC LOCK
26
EMERGENCY STOP DIAGRAM 24 VDC
27
EMERGENCY STOP DIAGRAM SINGLE PHASE 208 / 240 VAC
28
EMERGENCY STOP DIAGRAM THREE PHASE 208 / 240 VAC
29
EMERGENCY STOP DIAGRAM THREE PHASE 480 VAC
30
MANUAL KEY SWITCH DIAGRAM
31
GATE OP
EN INDICATOR LIGHT DIAGRAM 24 VDC
32
GATE OPEN INDICATOR LIGHT DIAGRAM SINGLE PHASE 208 / 240 VAC
33
GATE OPEN INDICATOR LIGHT DIAGRAM THREE PHASE 208 / 240 VAC
34
GATE OPEN INDICATOR LIGHT DIAGRAM THREE PHASE 480 VAC
35
SIREN OPERATED SENSOR DIAGRAM
3
6
SIREN OPERATED SENSOR INSTRUCTIONS
37, 38
ELECTRICAL LOOP LAYOUT
39
LOOP DETECTOR OPERATING INSTRUCTIONS
40
,
51
LOOP DETECTOR SOCKET DIAGRAM
52
RADIO RECEIVER DIAGRAM THREE BUTTON
53
RADIO RECEIVER DIAGRAM SINGLE BUTTON
54
RADIO RECEIVER INSTRUCTI
ONS
55, 62
REMOTE CONTROL STATION PEDESTAL
63
MONITORED REVERSING EDGE INSTALLATION
64
STANDARD
REVERSING EDGE INSTALLATION
65
CONTROL BOARD PROGRAM MENU
66,71
BLANK PAGE FOR NOTES
OPERATOR ENCLOSURE
72
PROPORTIONAL VALVE
SETTINGS
73
PROPORTIONAL
VALVE DIAGRAM
74
COLD WEATHER PACKAGE 24 VDC
75
COLD WEATHER PACKAGE SINGLE PHASE 208 / 240 VAC
76
COLD WEATHER PACKAGE THREE PHASE 208 / 240 VAC AND 460 / 480 VAC
77
BARRIER UNIT
78
OPERATOR FIELD INSTALLATION FOR ASSEMBLED GATE
79, 80
OPERATOR FIEL
D INSTALLATION FOR UNASSEMBLED GATE
79, 80
BALANCE SYSTEM ADJUSTMENT AND SAFETY WARNINGS
81, 82
SPRING, CABLE, AND SHEAVE REPLACEMENT
83, 84
GENERAL ARRANGEMENT & GENERAL MAINTENANCE
85, 86
BARRIER CARRIAGE
–
SHORT & STANDARD
87, 88

ACTUATOR CYLINDER
WITH COMPONENTS
89, 90
OMRON REFLECTIVE TYPE PHOTOEYE
91
BATTERY LOCATION 24 VOLT DC OPERATOR ONLY
92
BALANCE SYSTEM CABLE GUIDE
93
BALANCE SYSTEM
–
CABLE, SHEAVE & OPTIONAL ICE SCRAPER
94
BARRIER END STANCHION
-
PHOTO EYE
/
SURFACE MOUNT STANCHION
-
PHOTO EYE
95
MAGLOCK MOUNTING
96
BALANCE SYSTEM SPRING TENSIONER UNIT
97, 98
HYDRAULIC SYSTEM
99, 10
0
CUSTOM HYDRAULIC POWER UNIT
101, 102
TROUBLE SHOOTING GUIDE
103
, 105
CAUTIONS AND WARNINGS IN FRENCH
END

Tilt-A-Way
HYJG 1
Serial Number _______________
Barrier Size _______ Long _________Tall
Barrier Type _________________
Notes:

TILT-A-WAY LIMITED WARRANTY
Ideal Manufacturing warrants that its Tilt-A-Way vertical pivot gate HYJG product
will be free from defects in materials and workmanship for a period of 3 years from
the date of purchase. If the product fails to function because of defects in materials or
workmanship within the warranty period of time being used for the purpose for
which it was designed, Ideal Manufacturing will repair or replace the defective part at
its option. This warranty excludes electrical components and damage due to Acts of
God, unauthorized modifications, misuse, abuse or negligence to this product. This
warranty does not cover products or accessories that are not manufactured by Ideal
Manufacturing, Inc. That product follows the warranty, and guidelines of that
manufacturer.
In order to proceed with a warranty claim, Ideal Manufacturing must be notified of
the problem. A new part will be shipped out prepaid (Ground UPS). If the customer
requests that the part be expedited that shipping charge will be charged to the owner.
The part that is being warranted must be returned to Ideal Manufacturing, postage
prepaid. When the new part is shipped out, it will go out with an invoice and a
warranty part return number. The defective part must be returned to Ideal
Manufacturing, freight prepaid, with the warranty part return number. At that time
the invoice will be considered paid in full.
This warranty is exclusive and in lieu of all other obligation, liabilities or warranties.
In no event shall Ideal Manufacturing be liable or responsible for incidental or
consequential damage or for any other direct or indirect damage loss, cost, expense or
fee.
This warranty shall not apply to any products or parts that have been altered or
repaired without written consent of Ideal Manufacturing.
Labor to remove and reinstall defective product or parts will be paid from a labor rate
and schedule only. Consult Ideal Manufacturing for that rate and schedule.
For further information on returning your product or questions concerning Ideal
Manufacturing warranty, please contact Ideal Manufacturing.

IMPORTANT SAFETY INFORMATION
1
Before installing the installer should read and understand the owners manual and safety instructions. The owner should read,
and keep this owners manual. Read and Follow All Instructions.
WARNING-TO REDUCE THE RISK OF INJURY OR DEATH TO PERSONS
1. Do not operate gate unless all safety devices are connected and working properly.
2. The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. Do not adjust pressure
relief valve to compensate for an improperly installed, improperly functioning, or damaged gate.
3. Do not permit children to play on or around a gate. Keep all controls out of reach from children.
4. Automatic gates are not intended for pedestrian use. Pedestrians must be supplied a separate entrance separate from the automatic gate.
5. Never operate an automatic gate system without visual contact so it can be shut down if necessary.
6. Permanently mounted controls intended for user activation must be located at least 6 feet away from the gate and operator.
7. Disconnect all power before performing any maintenance on your gate or operator.
8. Keep your gate properly maintained-have a qualified service person make all repairs.
9. A qualified technician should test your gate monthly. The gate MUST reverse on contact with a rigid object. After adjusting the force of the
limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of injury or death.
10. The gate and operator must have two appropriate safety devices to match the gate class installation. Type A – inherent, and Type B2- Contact
sensor.
11. Operator and barrier must display warning signs on both sides, in view of operator.
12. Do not install added weight to the gate barrier, your barrier has been balanced at the factory, if you add weight to the barrier it will make your
gate out of balance, which could cause it to malfunction.
13. Before turning the power on make sure that the correct voltage has been supplied to the electric motor and the equipment has been properly
grounded.
14. Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.
15. Only qualified personnel should install this equipment. Failure to meet this requirement could cause severe injury and or death, for which the
manufacturer cannot be held responsible.
CLASS OF VEHICULAR GATES
Glossary
CLASS I-RESIDENTIAL VEHICULAR GATE OPERATOR (3.19)
A vehicular gate operator (or system) intended for use in garages or parking areas associated with a residence of one to four single families.
CLASS II-COMMERCIAL/GENERAL ACCESS VEHICULAR GATE OPERATOR (3.4)
A vehicular gate operator (or system) intended for use in a commercial location or building such as multi-family housing unit (five or more single
family unit), hotel, garages, retail store, or other buildings accessible by of servicing the general public.
CLASS III-INDUSTRIAL/LIMITED ACCESS VEHICULAR GATE OPERATOR (3.11)
A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations
not accessible by or intended to service the general public.
CLASS IV-RESTRICTED ACCESS VEHICULAR GATE OPERATOR (3.20)
A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other
restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personal.
INSTRUCTIONS FOR MANUAL OPERATION TILT-A-WAY MODEL HYJG
Note: Use the manual operation only when the gate is not moving and with the power turned off
1. Locate two Brass colored knurled knobs on the top of the pump housing
2. (If equipped with a cold weather package, lift flap on the black cover to access knobs.)
3. Turn both knobs counter clockwise one full turn to open.
4. Gate barrier can now be lifted manually from out at the end of gate.
5. Turn knobs clockwise to close, then operate gate normally.
PROTECTION AGAINST ENTRAPMENT
Gate operator category
Horizontal slide, vertical lift. and vertical pivot Swing and vertical barrier (arm)
Entrapment protection types (a) Entrapment protection types (a)
A, B1, B2, or D A, B1, B2, C, OR D
Note-The same type of device shall not be utilized for both entrapment protection means. Use of a single device to cover both the opening and closing directions is
in accordance with the requirement; however, a single device is not required to cover both directions. A combination of one Type B1 for one direction and one
Type B2 for the other direction is the equivalent of one device for the purpose of complying with the requirements of either entrapment protection means.
(a) Entrapment protection types:
Type A – Inherent entrapment protection system. See 31.1.5.
Type B1 –Non-contact sensor (photoelectric sensor or the equivalent). See 31.1.6 – 31.1.9.
Type B2 –Contact sensor (edge device or the equivalent). See 31.1.7 and 31.1.11 – 31.1.13.
Type C – Inherent force limiting, inherent adjustable clutch or inherent pressure relief device. See 31.1.15 and 31.2.1.2 (b).
Type D –Actuating device requiring continuous pressure to maintain opening or closing motion of the gate. See 31.1.16 and 31.1.17.

2
Specifications
Model# HYJG 1
Operator Size 28” W x 50” T x 120”L
Operator Weight 1,800 lbs.
Maximum Barrier Size 375 lbs
Voltage Phase Hz Cir. Reg. Amps. Act. Draw
208/240 VAC 1 60 20 14
208/240 VAC 3 60 10 9
480 VAC 3 60 5 3
Control Board Voltage
24 VDC
For 24 VDC motor operator
Voltage Hz Cir. Reg. Amps.
120 VAC 60 15 (for battery charger and accessories)
Motor Voltage Control Board Voltage
24 VDC 24 VDC
Operator Speed to 90* 16-20 Seconds
Hydraulic Fluid Citgo-CP (this hydraulic fluid is blue in color)
Maximum Operating Temperature 70 C / 158 F
Note: Hydraulic pump pressure factor set at 385 PSI do not exceed this setting
Note: Wire size is very important. Measure the distance from your power source to the gate
operator location. For wire sizes consult the NEC (National Electric Code).
Recommended Wire Size
208/240 VAC AMPS 20 SINGLE PHASE
Length of circuit in feet
20’-60’ 60’-100’ 100’–160’ 160’–240’ for circuit length greater than 240’ consult a licensed electrician
Wire size 12 10 8 6
208/240 VAC AMPS 10 THREE PHASE
Length of circuit in feet
20’–120’ 120’–180’ 180’–300’ 300’–480’ 480’–760’ 760’–1220’ 1220’–1540’ 1540’–1940’ 1940’–2440’
Wire size 14 12 10 8 6 4 3 2 1
460/480 VAC AMPS 5 THREE PHASE
Length of circuit in feet
20’–500’ 500’–800’ 800’–1280’ 1280’–2040’ 2040–3260’ 3260’–5200’ 5200’–8240’
Wire size 14 12 10 8 6 4 3
120 VAC AMPS 15
Length of circuit in feet
20’-60’ 60’-100’ 100’–160’ 160’–280’ for circuit length greater than 260’ consult a licensed electrician
Wire size 12 10 8 6

IDEAL MANUFACTURING INC.
3
ALTERNATE FENCE SCHEMES
HYJG 1

4
Tilt-A-Way HYJG 1
GENERAL INFORMATION
Tilt-A-Way HYJG vertical pivot gate operates on various voltages. They are 240-vac single
phase, 240-vac three phase, 480-vac three phase, or 24-vdc. If the gate operates on 24-vdc it well
need two 12-vdc batteries (batteries not included). We recommend two 12-volt dc maintenance
free lead acid deep cycle series 27 battery 85 amp hours or equivalent. The two 12-volt batteries
are wired in series to supply 24 volts to the control boards. The wiring harness is equipped with
ring terminals designed to connect to bolt type battery post (red wire to positive and black wire to
negative). See wiring diagram on page 9 of this manual. Do not reverse battery polarity at the
battery or circuit board. Severe damage will occur. Disconnect the battery and all power sources
before installing any devices. Do not perform any welding while the motor cable is connected to
the control board or the battery connected. Serious damage to the control board and battery will
occur.
Caution – Risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteries according to the batteries manufactures instructions.
Tilt-A-Way HYJG vertical pivot gate has a programmable control board, which allows numerous
programmable functions in various combinations (see programming section at in this manual).
The control board has Position Feedback. If the gate reverses direction twice and stops because of
the Position Feedback the control board will have to be UL reset.
A battery charger is supplied to keep the batteries charged on the 24-vdc model. See charger
owner’s manual for proper operation.
A qualified technician should check, and adjust all safeties monthly. The balance of the barrier
should also be checked, and adjusted monthly by a qualified technician.
Tilt-A-Way HYJG vertical pivot gate is supplied with two entrapment protection devices. Type
A, inherent entrapment protection system, manufacturer by Polytron on the logic control board
part number PEO202L. Type B2, contact-sensor edge, manufacturer by ASO Safety Solutions,
model 25.30. Both of the entrapment protection devices must be connected and functioning
properly before the gate operator is put into service. This is the maximum number of entrapment
protection devices to be connected to the operator.
Tilt-A-Way HYJG vertical pivot gate must be installed in a location so that enough clearance is
supplied between the gate and adjacent structures when opening and closing to reduce the risk of
entrapment.

HYJG-201
5
IDEAL MANUFACTURING INC. 2/17/2014
Cord to
Logic Board
TILT-A-WAY
HYJG 1
USER INTERFACE BOARD
TILT-A-WAY
INTERFACE BOARD
The interface board has many functions for the end user to access.
The four push buttons on the board are used to navigate the programming.
Push and hold button SW2 for about 4 seconds to enter the main program menu.
When in the program menu push and release button SW2 to exit main menu, or sub menus.
Button SW4 will scroll up in the menus, and adjustable settings in sub menus.
Button SW3 will scroll down in the menus, and adjustable settings in sub menus.
Button SW1 will enter into menus, and sub menus.
When in sub menus, and after changing adjustable setting the SW1 button will save the change
when pushed.
The interface does not have to be connected to the Logic Board for the gate to open or close.
See program section of this manual for full program menus.
Program Navigation
Buttons
Display Screen
UP DOWN ENT/MAIN
EXIT/SUB
ENT/SUB
SAVE

HYJG-202
6
IDEAL MANUFACTURING INC. 6-10-2015
Cord to
Interface Board
TILT-A-WAY
HYJG 1
LOGIC CONTROL BOARD
Programmable Loop
Detector sockets
12 Volt DC Power
Maximum Current Draw
1 amp Total (not fused)
Optional Radio
Receiver
UL 325 Entrapement
Reset Button
Wires To Motor
Control Board
24 Volt DC
Power In
24 Volt DC
Power Out 5 amp
Fuse Protected
Entrapment dry
contact (NO)
Prewarn
dry contacts
(NO and NC)
Aux Relay #1
dry contact (NO)
Controller
Ground
Aux Relay #2
dry contact (NO)
Aux Relay #3
dry contacts
(NO and NC)
On Board Push
Button Station
Open Input
Close Input
Stop Input
Single Input
Aux Timer Input
Timer Hole Input
Rev Open Input
Timer Set Input
Aux #1 Input
Aux #2 Input
Leaf 1 Closing Safety
Leaf 1 Opening Safety
Leaf 2 Closing Safety
Leaf 2 Opening Safety
5amp Fuse
Not Used

7
TILT-A-WAY
HYJG 1 MOTOR CONTROL BOARD
Wires From
Logic Board
Wires To
Potentiometer
Wires To Limit
Switch's (NC)
Wires To Motor
Contactor
Power In From
Logic Board
2 amp Fuse
HYJG-203
IDEAL MANUFACTURING INC. 6-10-2015
Wires To Close
Solenoid Valve
WiresTo Open
Solenoid Valve
HYDRAULIC
IDEAL MFG., INC.

8
TILT-A-WAY HYJG 1
BASIC ELECTRICAL HARDWARE 24-VDC
DRAWING HYJG-204 ON PAGE 9 SINGLE GATE
DRAWING HYJG-205 ON PAGE 10 MASTER GATE
REF
PART NO.
DESCRIPTION
QTY
1
P00
961
ENCLOSURE
1
2
PE
O6
70
CIRCUIT BREAKER
(15 AMP)
1
3
PEO671
CIRCUIT BREAKER (40 AMP)
1
4
PEO202I
INTERFACE BOARD
1
5
PEO202L
LOGIC BOARD
1
6
PEO202
H
MOTOR BOARD
1
7
PEO202C
CONNECTING CORD
1
8
PEO
61
1
SAFETY SWITCH
2
9
PEO
963
LIMIT SWITCH (nc)
4
10
100234
POTENTIOMETER
1
11
PEO223
½” ROMEX
3
12
PEO275
¾” ROMEX
3
13
100127
ALARM
1
14
TWO448
BATTERY CHARGER (24 VOLT)
1
15
PEO605A
RELAY SOCKET 5 PIN
1
16
PEO679
RELAY 5 PIN SAFETY
1
17
PEO620
END BARRIER (not shown)
1
18
PEO621
G
REEN
TERMINAL BLOCK
1
19
PEO622
BLACK
TERMINAL BLOCK
3
20
PEO623
RED
TERMINAL BLOCK
3
21
PEO665
RADI
O RECEIVER (optional not shown)
1
22
PEO663
RADIO TRANSMITTER (optional not shown)
as req.
23
PEO674
POWER CONTACTOR
1
24
100133
DIODE
1
DRAWING HYJG-206 ON PAGE 11 SLAVE GATE
REF
PART NO.
DESCRIPTION
QTY
1
P
EO29
2
ENCLOSURE
1
2
P
E
O
670
CIRCUIT BREAKER
(15 AMP)
1
3
PEO671
CIRCUIT BREAKER
(40 AMP)
1
5
PEO202H
MOTOR BOARD
1
8
PEO
611
SAFETY SWITCH
2
9
PEO
963
LIMIT SWITCH (nc)
4
10
1001234
POTENTIOMETER
1
11
PEO223
½” ROMEX
3
12
PEO275
¾” ROMEX
3
14
TWO448
BATT
ERY CHARGER (24 VOLT)
1
15
PEO605A
RELAY SOCKET 5 PIN
1
16
PEO679
RELAY 5 PIN SAFETY
1
17
PEO620
END BARRIER (not shown)
1
18
PEO621
GREEN TERMINAL BLOCK
1
19
PEO622
BLACK TERMINAL BLOCK
3
20
PEO623
RED TERMINAL BLOCK
3
23
PEO674
POWER CONTACTOR
1
24
100
133
DIODE
1

UP DOW N
ENT / MAIN
EXIT/ SUB
ENT/SUB
SAVE
TILT-A-WAY HYJG 1
SINGLE GATE 24 VOLT DC
ID EAL MANU FACTURING INC.
9

UP DOWN ENT/MAIN
EXIT/SUB
ENT/SUB
SAVE
TILT-A-WAY HYJG 1
MASTER GATE 24 VOLT DC
IDEAL MAN UFAC TURING INC.
10

TILT-A-WAY HYJG 1
SLAVE GATE 24 VOLT DC
ID EAL MANU FACT URING INC.
11

12
TILT-A-WAY
HYJG 1
BASIC ELECTRICAL HARDWARE 240-VAC SINGLE PHASE
DRAWING HYJG-207 ON PAGE 13 SINGLE GATE
DRAWING HYJG-208 ON PAGE 14 MASTER GATE
REF
PART NO.
DESCRIPTION
QTY
1
P00
961
ENCLOSURE
1
2
PE
O6
02
CIRCUIT BREAKER
1
3
100117
B
POWER SUPPLY (24
-
VD
C)
1
4
PEO202I
INTERFACE BOARD
1
5
PEO202L
LOGIC BOARD
1
6
PEO202
H
MOTOR BOARD
1
7
PEO202C
CONNECTING CORD
1
8
PEO
611
SAFETY SWITCH
2
9
PEO
963
A
LIMIT SWITCH (nc)
4
10
100234
POTENTIOMETER
1
11
PEO223
½” ROMEX
3
12
PEO275
¾” ROMEX
3
13
100127
ALA
RM
1
14
PEO604
OVERLOAD RELAY
1
15
PEO605A
RELAY SOCKET 5 PIN
1
16
PEO679
RELAY 5 PIN SAFETY
1
17
PEO620
END BARRIER (not shown)
1
18
PEO621
G
REEN
TERMINAL BLOCK
1
19
PEO622
BLACK
TERMINAL BLOCK
2
20
PEO623
RED
TERMINAL BLOCK
2
21
PEO665
RADIO REC
EIVER (optional not shown)
1
22
PEO663
RADIO TRANSMITTER (optional not shown)
as req.
23
100128
CONTACTOR
1
DRAWING HYJG-209 ON PAGE 15 SLAVE GATE
REF
PART NO.
DESCRIPTION
QTY
1
P
EO292
ENCLOSURE
1
2
P
E
O
6
02
CIRCUIT BREAKER
1
3
100117B POWER SUPPLY (24-VDC)
1
6
PEO202
H
MOTOR BOARD
1
8
PEO
611
SAFETY SWITCH
2
9
PEO
963
A
LIMIT SWITCH (nc)
4
10
100234
POTENTIOMETER
1
11
PEO223
½” ROMEX
3
12
PEO275
¾” ROMEX
2
14
PEO604 OVERLOAD RELAY
1
15
PEO605A
RELAY SOCKET 5 PIN
1
16
PEO679
RELAY 5 PIN SAFETY
1
17
PEO620
END BARRIER (not shown)
1
18
PEO621
GREEN TERMINAL BLOCK
1
19
PEO622
BLACK TERMINAL BLOCK
2
20
PEO623
RED TERMINAL BLOCK
2
23
100128
CONTACTOR
1

UP DOWN ENT/MAIN
EXIT/SUB
ENT/SUB
SAVE
TILT-A-WAY HYJG 1
SINGLE GATE 240 VOLT SINGLE PHASE
IDEAL MANUFACTURING INC.
13

UP DOWN ENT/MAIN
EXIT/SUB
ENT/SUB
SAVE
TILT-A-WAY HYJG 1
MASTER GATE 240 VOLT SINGLE PHASE
IDEAL MANUFACTURING INC.
14

TILT-A-WAY HYJG 1
SLAVE GATE 240 VOLT SINGLE PHASE
IDEAL M AN UFACTURING INC.
15
Table of contents
Languages: