Iijima KO-X1 User manual

KOX1TS -0210
□□□□□□□□□□□□□□□□□□□□
Opener / KO-X1
Operation Manual
□□□□□□□□□□□□□□□□□□□□
Thank you for purchasing the Iijima Opener “model KO-X1”.
The opener KO-X1 is a hole opening tool designed mainly for plastic caps used on
plastic bottles. Refrain from using this tool to open holes in other caps made of hard
materials, etc., as there is a risk of faults. Do not apply force with other tools when
opening holes. Doing so could result in faults.
Always read and fully understand this manual before starting to ensure correct and
safe use. Keep this manual near the tool for quick reference at any time.

1
KOX1TS -0210
1. Confirmation of Package Contents
When unpacking the KO-X1 Opener, confirm that the following items are included and that the
contents have not been damaged. If any parts are missing or damaged, contact the dealer which
you purchased the product.
Package contents
Description Quantity
1
Opener (model:KO-X1) 1
2
Needle (ø0.8x74 mm)
The 74 mm long needle is dedicated for the KO-X1.
Specify "Needle (model: T-X1, 5-pc. set)" when ordering additional needles.
1 pc.
3
Rubber stopper 1
Specify "Rubber Stopper 1 (model: M-10, 30-pc. set)" when ordering
additional rubber stoppers.
10 pcs.
4
Rubber stopper 2
Specify "Rubber Stopper 2 (model: M-20, 30-pc. set)" when ordering
additional rubber stoppers.
10 pcs.
5
Rubber packing (ø10) 2 pcs.
6
Operation manual (this document) 1
2. Names of each part
The opener is shipped with all parts set. Refer to the following drawing when replacing or servicing
parts. ← Rubber holder (fixed by screwing in)
Rubber stopper 1
Rubber packing ø10 <State with needle inserted>
← Needle (T-X1)
← Rotating handle
← Fixing screw with jaw
Main body
Jaw fixing base
Jaw Jaw
Cutter Rubber stopper 2
Needle tip
penetrates

2
KOX1TS -0210
3. Preparing for use
Make sure the sample bottle meets the following conditions.
<Usage conditions>
Cap height: min.16mm to max.35mm
Neck diameter : min. ø22mm to max. ø36mm
Step 1. Remove the standard needle attached with the oxygen meter.
• For oxygen meter models RO-105 series, the standard needle is model: NN-2116R.
• For oxygen meter models RO-103 series, the standard needle is model: NN-2138S.
When removing the needle, do not remove the accessories, such as the membrane filter
or check valve. Proper measurements may not be possible if these parts are removed.
Step 2. Attach the needle dedicated for the KO-X1.
Take care not to stab the human body with the needle. There is a risk of blindness,
puncture wounds, or cuts.
Step 3. Prepare the oxygen meter with state and setting so that it is ready for measurement.
(Refer to the operation manual enclosed with the oxygen meter for details.)
4. Usage methods
Step 1. Grip the neck of the measurement sample, such as
the plastic bottle, with the jaws on either side.
Turn the fixing screws and fix the jaw fixing base so that the
jaws tightly grip the sample's neck and do not move.
Step 2. Hold the jaw fixing base on either side with a hand
to prevent movement, and then turn the rotating
handle clockwise.
Turn the rotating handle two turns
from where the cutter contacts the
cap.
Do not turn the rotating handle further once the hole is opened. Rotating it further will put
an excessive load on the threads and can result in damage.
Grip the neck with the jaws on either side
View from below

3
KOX1TS -0210
Step 3. Insert the needle into the hole on the rubber stopper.
The tip of the needle will reach the headspace of the sample in the
plastic bottle, etc.
Step 4. Operate the oxygen meter to sample and measure the
sample gas.
For details, refer to the measurement methods described in the
operation manual enclosed with the oxygen meter.
• If there is less than 10mL of sample gas, or if the sample cannot be used the KO-X1
because of the shapes and materials, measure with the Gas Sampling Glass Tube
(model: GS-2) option (sold separately).
• A measurement can be taken even if the inside of the sample is pressurized. However,
if the inner pressure of the package is higher than +40 kPa, the components could break
when the needle is pierced, or a correct measurement value may not be obtained.
<Using oxygen meter RO-105 series >
Do not use the KO-X1 Opener when measuring a sample pressurized above +40 kPa.
Instead, measure with the Gass Sampling Glass Tube (model: GS-2) option (sold
separately).
<Using oxygen meter RO-103S>
Measure with the Compression and Decompression Sampler (model: S-2) option. In
this case, repeat the suction operation two to three times to sample the gas and read
the value when the sample gas is stabilized.
• If there are any concerning symptoms, refer to the symptoms and actions explained in
the Troubleshooting Section of the operation manual enclosed with the oxygen meter.
Replace rubber stopper 1 and rubber stopper 2 with new parts if any degradation is
observed.
Please contact the dealer from which you purchased the product if you have any questions or inquiries
regarding handling, repairs, or inspections.
You can also watch the video on how to handle the product. https://www.iijima-e.co.jp/en/video.html
1-1, Ishida, Toyooka-cho, Gamagori-shi, Aichi 443-0011 JAPAN
Telephone: +81-533-67-2827 Facsimile: +81-533-69-6814 E-mail: eigyou@iijima-e.co.jp
https://www.iijima-e.co.jp/
Note
Note
<Video page>
Table of contents
Popular Gate Opener manuals by other brands

BFT
BFT ELI-250 Installation and user manual

Chamberlain
Chamberlain LiftMaster Professional BG770 Installation and maintenance manual

tau
tau Easy Series Use and maintenance manual

Casanoov
Casanoov VOGEL 500C160 instruction manual

RIB
RIB KING Series Operating and installation instructions

BFT
BFT ORO installation manual