BFT D113745-00001 User manual

POWER + ----------- 51
POWER - ----------- 50
RELAY COMMON ----------- 60
----------- 62RELAY N.O.
PHOTOCELL SENSOR AND/OR LOOP
DETECTOR WIRING (CLOSING OBSTRUCTION)
OPEN ONLY” DEVICE
(RADIO RECEIVER, KEYPAD, ETC.)
POWER + ----------- 51
POWER - ----------- 50
RELAY COMMON ----------- 60
----------- 61RELAY N.O.
(ONLY IF POWER
IS REQUIRED)
START COMMAND” DEVICE
(SINGLE PUSH-BUTTON,RADIO RECEIVER, KEYPAD,
ETC.)
external lock wiring
wiring peripheral devices
SHADOW LOOP SENSOR WIRING
(PREVENTS THE GATE FROM STARTING
TO CLOSE)
PROGRAMMING: LOGIC > SAFE 2 = 004
> AUX 3 = 006
instal jumpers
thalia connection terminals
phobos & igea BT wiring
*igea only on left side operators, black &–
red wires are swapped at the motor.
selecting which motor is motor 1 and which is motor 2
motor 1 opens first and closes second; motor 2 opens second and closes first
wire color
1 white 42 43
2red 10 14
3black 11 15
motor
terminal
thalia p
motor 1
thalia p
motor 2
QUICK SETUP MENU
PRESS THE [OK] BUTTON ONCE TO ENTER. use [+] and [-] to find selection. use [ok] to select
preset table
features A R S R A C S C I ND
INDUSTRIAL
AUTOMATIC CLOSING TIMER x x
x x
UNINTERRUPTED OPEN CYCLE x x
INSTANT REVERSE ON CLOSING x x
HOLD TO RUN x
QUICK REMOTE PROGRAMMING xxxx
AUTOMATIC
RESIDENTIAL
SEMI-AUTOMATIC
RESIDENTIAL
AUTOMATIC
COMMERCIAL
SEMI-AUTOMATIC
COMMERCIAL
PRE-ALARM
thalia quick reference
version 120921A
SIMULTANEOUSLY PRESS AND
HOLD THE 2 BUTTONS ON
YOUR REMOTE UNTIL THE
SCREEN READS RELEASE”
THE SCREEN WILL THEN READ
DESIRED BUTTON”. PRESS
THE BUTTON YOU WANT TO
OPERATE THE GATE WITH
THE SCREEN WILL DISPLAY OK”
AND THE NUMBER OF THE
REMOTE IN MEMORY. REPEAT THE
PROCESS FOR ADDITIONAL
REMOTES
programming remotes after you see –hidden button” displayed on the screen...
pre-alarm: aux with value set
to 6, active for 3 seconds
before gate movement
uninterrupted open cycle: a
start command will not stop
the gate from opening.
instant reverse: a start
command will stop and
reverse a closing gate.
otherwise it just stops it and
an additional start command
will reverse it.
only use 16 awg, stranded, sjtow or sjtoow cable.
avoid splices. if necessary, a splice must be above ground in a dry junction box
█████████████████████ █ █ █ █ █
10 11 14 15 20 21 26 27 40 41 42 43 44 45 50 51 52 60 61 62 70 71 72 73 74 75
10 motor 1 +–
11 motor 1 -–
14 motor 2 +–
15 motor 2 -–
20 & 21 24v courtesy light output–
(25w max)
26 & 27 aux 3 – –
Radio receiver 2nd channel
40 - encoder / limit reference –
41 - encoder / limit common
42 encoder / limit 1–
43 - encoder / limit 2
44 - limit 3
45 - limit 4
accessory power (-) 50–
accessory power (+) - 51
vsafe power (+) - 52
common 60–
start command ic1 -61–
ped (partial opening) ic2 62– –
70 Common–
71 stop–
72 safe 1 phot (obstruction)– –
73 fault 1–
74 safe 2 bar (safety edge)– –
75 fault 2–
PROGRAMMING: LOGIC > IC 2 = 002
PROGRAMMING: LOGIC > SAFE 1 = 004
POWER + ----------- 51
POWER - ----------- 50
RELAY COMMON ----------- 70
----------- 72RELAY N.C.
POWER + ----------- 51
POWER - ----------- 50
RELAY COMMON ----------- 70
----------- 74
26
27
RELAY N.C.
PROGRAMMING: LOGIC > AUX 3 > 007 = SOLENOID LOCK
008 = MAGLOCK
krelay24v
krelay24v
+ POWER SUPPLY *MAGLOCK ONLY
+ POWER SUPPLY *SOLENOID LOCK ONLY
- POWER SUPPLY
- LOCK POWER
+ LOCK POWER
P/N: KRELAY24V IS REQUIRED (NOT INCLUDED)
t yp e pr es et a u t o set
2 int (interior) hidden button
1 ext (exterior) release
ac (automatic commercial) desired button
ind (industrial)
l a ng
(language)
n,mot
(number of
motors)
dir
(open direction) mem remotes
ita (italian) eli ar (automatic residential)
fra (french) phob (phobos) sr (semi-automatic residential)
deu (german) igea
eng (english) sc (semi-automatic commercial)
esp (spanish)
26
27
white
red
blue
orange
yellow
fUSE VALUES:
F1 = 2.5 a SLOW-BLOW
F2 = 3.15 A SLOW-BLOW
www.BFTGateOpeners.com | (800) 878-7829 | [email protected]

VALUE FUNCTION
0 START EXTERNAL–● ● ●
1 START INTERNAL–● ● ●
2 OPEN ● ● ●
3 CLOSE ● ● ●
4● ● ●
5 TIMER (HOLD OPEN) ● ● ●
6● ● ●
7● ●
8● ●
9● ●
10 SAFETY EDGE (bar) ● ●
11 OBSTRUCTION, SUPERVISED ●
12 OPENING OBSTRUCTION, SUPERVISED ●
13 CLOSING OBSTRUCTION, SUPERVISED ●
14 SAFETY EDGE, SUPERVISED ●
IC & EXPI LOGICS
IC 1 & 2 EXPI 1 EXPI 2
PED (PARTIAL OPEN)
TIMER PED (HOLD PARTIAL OPEN)
OBSTRUCTION (phot)
OPENING OBSTRUCTION (phop)
CLOSING OBSTRUCTION (phcl)
error description error description
er20 motor 2 improper encoder movement detected er35 motor 1 obstacle detection during opening
er22 motor 2 opposite movement er36 motor 1 obstacle detection during closing
er25 motor 1 improper encoder movement detected er37 motor 1 obstacle detection during opening slowdown
er27 motor 1 opposite movement er38 motor 1 obstacle detection during closing slowdown
er30 motor 2 obstacle detection during opening er40 thermal overload
er31 motor 2 obstacle detection during closing er61 operating on battery power
er32 motor 2 obstacle detection during opening slowdown error setting limits
er33 motor 2 obstacle detection during closing slowdown erf9 lock output overload
ersw
V A L U E 0 1 2
L O G I C 4-STEP 3-STEP 2-STEP
OPEN I NG STOPS + TCA STOPS + TCA REVERSES
C L O S I NG STOPS REVERSES REVERSES
STEP-BY-STEP LOGICS
VALUE FUNCTION
0 2ND CHANNEL RECEIVER OUTPUT
1 GATE OPEN LIGHT. output active WHEN GATE IS NOT CLOSED. FLASHES WHILE CLOSING
2 COURTESY LIGHT. output active DURING AND FOR 90 SECONDS AFTER OPERATION.
3 GATE NOT CLOSED. output active UNTIL CLOSE LIMIT IS REACHED
4 START OF CYCLE. output active FOR 1 SECOND AT THE BEGINNING OF EACH CYCLE
5 GATE OPEN ALARM. output active IF GATE IS HELD OPEN FOR MORE THAN DOUBLE THE TIMER TO CLOSE TIME
6 GATE RUNNING. output active WHILE MOTORS ARE POWERED
7 SOLENOID LOCK. output active FOR 2 SECOND AT THE BEGINNING OF OPEN CYCLE
8 MAGNETIC LOCK. output active WHEN GATE IS CLOSED
9
AUX & expo LOGICS
TRAFFIC LIGHT CONTROL (EXPANSION BOARD OUTPUT WITH TLB BOARD ONLY)
*note - when the expansion board
input 1 (expi 1) is set to values 11 ~ 14,
the expansion board input 2 (expi 2)
automatically becomes the
supervision circuit (fault).
advanced programming of inputs and outputs
DOWN
ENTER
UP
escape
navigating the programming menu
button navigation value edit
[+] scrolls up increase value
[-] scrolls down decrease value
enter enter value
[+] & [-] escape escape
[ok]
press the [ok] button rapidly twice to enter programming
VALUE FUNCTION DESCRIPTION
0 OBSTRUCTION SENSOR INPUT, NON-CONTACT
1 OBSTRUCTION SENSOR INPUT, NON-CONTACT, supervised (fault active)
2 OPENING OBSTRUCTION SENSOR INPUT, NON-CONTACT
3 OPENING OBSTRUCTION SENSOR INPUT, NON-CONTACT, supervised (fault active)
4 CLOSING OBSTRUCTION SENSOR INPUT, NON-CONTACT
5 CLOSING OBSTRUCTION SENSOR INPUT, NON-CONTACT, supervised (fault active)
6 BAR SAFETY EDGE (CONTACT OBSTRUCTION) INPUT
7 BAR TEST SAFETY EDGE (CONTACT OBSTRUCTION) INPUT, supervised (fault active)
8 BAR 8K2
SAFE LOGICS
PHOT
PHOT TEST
PHOT OP
PHOT OP TEST
PHOT CL
PHOT CL TEST
SAFETY EDGE (CONTACT OBSTRUCTION) EOL RESISTOR SUPERVISED INPUT
common error codes
MAIN SELECTION DESCRIPTION DEFAULT RANGE
PARAM > OPEN DELAY TIME Motor 2 opening delay in seconds 10-10
Motor 1 closing delay in seconds 10-10
TCA Auto-close time adjustment in seconds 10 1-180
Traffic zone clear time adjustment in seconds 40 1-180
Slowdown starting distance from end of open travel expressed in percentage 10 0-50
Slowdown starting distance from end of close travel expressed in percentage 10 0-50
Slowdown starting distance from end of open and close travel expressed in percentage 15 0-50
OP. FORCE Percentage of opening force exerted over the AUTOSET value before obstruction is sensed 50 1-99
Percentage of closing force exerted over the AUTOSET value before obstruction is sensed 50 1-99
OP SPEED Motor opening speed expressed in percentage 99 15-99
CL SPEED Motor closing speed expressed in percentage 99 15-99
SLOW SPEED Slowdown speed expressed in percentage from maximum speed. 25 15-99
LOGIC > MOTOR TYPE 1=Eli 250; 2=Phobos BT, 3=Igea BT 0 0-3
TCA Timer to Close Automatically. 0=OFF / 1=ON 0 0-1
Closes when sensors are cleared. 0=OFF / 1=ON 0 0-1
STEP-BY-STEP MOVEMENT * Determines how the system reacts when a START command is received during operation 0 0-2
Gate running output (AUX value=6) closes 3 sec. before gate movement. 0=OFF / 1=ON 0 0-1
HOLD-TO-RUN Requires continuous OPEN or CLOSE command input for gate to operate. 0=OFF / 1=ON 0 0-2
Ignores START input during the opening cycle. 0=OFF / 1=ON 0 0-1
Ignores the START input while counting down for automatic closing. 0=OFF / 1=ON 0 0-1
Ignores the START input during the closing cycle. 0=OFF / 1=ON 0 0-1
RAM BLOW C. OP Pushes gate against physical stop before opening 0 0-1
RAM BLOW C. CL Pushes gate against physical stop before closing 0 0-1
BLOC PERSIST Hourly push against physical stop 0 0-1
Pushes gate against physical stop for .5 seconds after close limit has been reached. 0 0-1
ICE Continuous force learning on every operation. 0 0-1
1 MOT. ON Single Motor operation. 0= (2)motors; 1=(1)motor. 0 0-1
OPEN IN OTHER DIRECT. 0 = Pull to open; 1 = Push to open 0 0-1
SAFE 1 * 0 0-8
SAFE 2 * Configuration of safety input terminal 74. Defaulted as Bar (Safety Edge) 6 0-8
Configuration of command input terminal 61. Defaulted as Start E 0 0-6
4 0-6
AUX 3 * 0 0-8
FIXED CODE Rolling code defeat. 0 = rolling code; 1 = fixed code 0 0-1
Quick remote programming. 0 = disabled; 1 = enabled 1 0-1
SERIAL MODE 0 = Slave unit; 1 = Master unit 0 0-1
ADDRESS Unit's network identification number. 0 0-127
Configuration of Expansion board input 1. Defaulted as Start command. 1 0-14
Configuration of Expansion board input 2. Defaulted as Start command. 0 0-10
EXPO 1 * Configuration of Expansion board output 1. Defaulted as Traffic light control.. 9 0-9
EXPO 2 * Configuration of Expansion board output 2. Defaulted as Traffic light control.. 9 0-9
Red light flashes for 3 sec. at every start. 0 = Off; 1 = On 0 0-1
TRAFFIC LIGHT RED LAMP ALWAYS ON Red light remains on when gate is closed. 0 = Off; 1 = On 0 0-1
RADIO > ADD START Learns transmitter button as START command
ADD 2CH
ERASE 64 Erase complete memory
COD RX Show receiver ID Code
WK W LINK.
DEFAULT Restores board to factory settings. No effect on RADIO
LANGUAGE > Italian
French
German
ENG English
ESP Spanish
AUTOSET Operates motor(s) several times and automatically adjust its FORCE settings
L. SW ADJ Limit of travel adjustment. Only available with type 4 and 5 motors
STAT > Displays board firmware version.
N. CYCLES Displays number of hundreds of cycles (001=100; 010=1000; 100=10,000)
N. REMOTES Displays the number of remotes in memory.
ERR Displays the last 30 board errors in descending order.
PASSWORD Password setting for wireless programmer
CLS DELAY TIME
TRF. LGHT.CLR. T
OP. DIST. SLOWD
CL. DIST. SLOWD
DIST. DECEL
CLS. FORCE
FAST CLS.
PRE-ALARM
IBL OPEN
IBL TCA
IBL CLOSE
PRESS SWC
Configuration of safety input terminal 72. Defaulted as Phot (Obstruction)
IC 1 *
IC 2 * Configuration of command input terminal 62. Defaulted as Ped (Partial open)
Configuration of auxiliary output terminals 26 & 27. Defaulted as 2nd channel contacts.
RADIO PROG
EXPI 1 *
EXPI 2 *
TRAFFIC LIGHT PREFLASHING
Learns transmitter button as 2nd channel
ITA
FRA
DEU
VERS
www.BFTGateOpeners.com | (800) 878-7829 | [email protected]
Other BFT Gate Opener manuals

BFT
BFT PHOBOS NL BT User manual

BFT
BFT ELI 250 BT User manual

BFT
BFT PHOBOS N BT User manual

BFT
BFT KUSTOS ULTRA BT User manual

BFT
BFT LUX FC User manual

BFT
BFT AKTA A30 User manual

BFT
BFT ICARO User manual

BFT
BFT MOOVI AC 30 User manual

BFT
BFT PHOBOS AC A25 230 User manual

BFT
BFT DEIMOS BT KIT UL User manual