Immergas MAGIS M4-30 Technical manual

MAGIS
M4-30
Block heat pumps
Use and Installation
IE
Instructions and warnings
*1.046978ENG*
*1.046978ENG*


Dear Customer,
Congratulations for having chosen a top-quality Immergas product, able to assure well-being and safety for a long period of
time. As an Immergas customer you can also count on a Qualied Authorised Aer-Sales Technical Assistance Centre, prepared
and updated to guarantee constant eciency of your appliance. Read the following pages carefully: you will be able to draw
useful tips on the proper use of the device, compliance with which will conrm your satisfaction with the Immergas product.
For assistance and routine maintenance, contact Authorised Technical Service Centres: they have original spare parts and are
specically trained directly by the manufacturer.
General warnings
All Immergas products are protected with suitable transport packaging.
e material must be stored in a dry place protected from the weather.
e instruction booklet is an integral and essential part of the product and must be given to the new user in the case of transfer
or succession of ownership.
It must be stored with care and consulted carefully, as all of the warnings provide important safety indications for installation,
use and maintenance stages.
is instruction manual provides technical information for installing the Immergas pack. As for the other issues related to pack
installation (e.g. safety in the work site, environment protection, injury prevention), it is necessary to comply with the provisions
specied in the regulations in force and good practice rules.
In compliance with legislation in force, the systems must be designed by qualied professionals, within the dimensional limits
established by the Law. Installation and maintenance must be performed in compliance with the regulations in force, according
to the manufacturer's instructions and by professionally qualied sta, intended as sta with specic technical skills in the
system sector, as envisioned by the Law.
Improper installation or assembly of the Immergas appliance and/or components, accessories, kits and devices can cause
unexpected problems for people, animals and objects. Read the instructions provided with the product carefully to ensure
proper installation.
Maintenance must be carried out by skilled technical sta. e Authorised Aer-Sales Service represents a guarantee in terms
of qualications and professionalism.
e appliance must only be destined for the use for which it has been expressly declared. Any other use will be considered
improper and therefore potentially dangerous.
If errors occur during installation, operation and maintenance, due to non-compliance with technical laws in force, standards
or instructions contained in this book (or however supplied by the manufacturer), the manufacturer is excluded from any
contractual and extra-contractual liability for any damage and the appliance warranty is invalidated.
e company IMMERGAS S.p.A., with registered oce in via Cisa Ligure 95 42041 Brescello (RE), declares that the design,
manufacturing and aer-sales assistance processes comply with the requirements of standard UNI EN ISO 9001:2015.
For further details on the product CE marking, request a copy of the Declaration of Conformity from the manufacturer,
specifying the appliance model and the language of the country.
e manufacturer declines all liability due to printing or transcription errors, reserving the right to make any modications
to its technical and commercial documents without forewarning.

INDEX
• is manual provides a detailed explanation on the precautions to be taken during use.
• Read this manual carefully before using the wall-mounted control unit to guarantee its proper operation.
• Aer you have read this manual, keep it for future consultation.
Introduction ........................................................................................ 5
1 General safety warnings............................................................. 7
2 General Introduction................................................................ 11
3 Accessories................................................................................. 14
3.1 Accessories supplied with the units 4-16 kw. ........................ 14
3.2 Accessories supplied with the units 18-30 kw....................... 15
4 Prior to installation................................................................... 16
5 Important information on the refrigerant............................. 17
6 Installation site. ......................................................................... 18
6.1 Selection of a cold weather location. ...................................... 21
6.2 Selection of a hot weather location......................................... 21
7 Installation precautions............................................................ 22
7.1 Dimensions................................................................................ 22
7.2 Installation requirements......................................................... 23
7.3 Position of drain hole. .............................................................. 23
7.4 Clearance requirements for maintenance.............................. 24
7.5 Control Panel installation manual.......................................... 26
8 Typical application examples................................................... 30
8.1 UNITS 4-16 KW: Application 1.............................................. 30
8.2 UNITS 4-16 KW: Application 2.............................................. 33
8.3 UNITS 4-16 KW: Cascade System.......................................... 37
8.4 UNITS 18-30 KW: application 1............................................. 39
8.5 UNITS 18-30 KW: Application 2............................................ 40
8.6 UNITS 18-30 KW: Application 3............................................ 42
8.7 UNITS 18-30 KW: Application 4............................................ 44
8.8 UNITS 18-30 KW: Application 5............................................ 46
8.9 UNITS 18-30 KW: Cascade system application. .................. 48
9 Overview of the unit................................................................. 49
9.1 Disassembling the unit............................................................. 49
9.2 Main components ..................................................................... 50
9.3 Electronic control box.............................................................. 52
9.4 Water pipes. ............................................................................... 69
9.5 Filling with water....................................................................... 74
9.6 Water pipe insulation. .............................................................. 75
9.7 Wiring on eld. ......................................................................... 75
10 Start up and conguration....................................................... 98
10.1Overview of dip switch settings. ............................................. 98
10.2Initial start-up at low outdoor temperatures......................... 98
10.3Checks prior to operation........................................................ 99
10.4e circulation pump. .............................................................. 99
10.5On-eld settings...................................................................... 102
11 Test mode and nal checks.................................................... 120
11.1Final checks. ............................................................................ 120
11.2Test operation (manual)......................................................... 120
12 Maintenance and service........................................................ 121
13 Troubleshooting. ..................................................................... 122
13.1General guidelines. ................................................................. 122
13.2General symptoms.................................................................. 122
13.3Operation parameters. ........................................................... 124
13.4Error codes............................................................................... 125
14 Technical specications.......................................................... 132
14.1General. .................................................................................... 132
14.2Electrical technical specications......................................... 133
15 Information on maintenance................................................. 134
15.1Annexes - Refrigerant cycle................................................... 138

5
Sistema di controllo elettrico
Morsettiera
Sistema idraulico
Sistema di refrigerazione Si prega di rimuovere il pannello
di protezione dopo l'installazione.
Magis M 4/6
Magis M 8/12/14/16
Internal arrangement: Magis M 12-16 T
Magis M 4/6
Magis M 8/12/14/16
Magis M 12/14/16
Eliminate
the transport
mount
INTRODUCTION
Please remove the protective panel
aer installation.
Electric control system
Terminal board
Chilling system
Hydraulic system

6
Sistema di refrigerazione
Morsettiera
Sistema di controllo elettrico
Sistema idraulico
e images in this manual are only used as a reference - refer to the actual product.
NOTA
NOTE
- e maximum length of the wiring that guarantees communication between the heat pump and the control panel is
50 m.
- e power cables and communication wires are laid separately and cannot be placed in the same duct. Otherwise there
would be electromagnetic interference. e power cables and wires for communication must not come into contact
with the refrigerant pipe which at high temperatures could damage the wires.
- e communication wires must be in shielded lines, including the line that goes from the heat pump to the control
panel.
NOTA
NOTE
Magis M 18/22/26/30
Wiring diagram
Electric control system
Terminal board
Chilling system
Hydraulic system

7
1
GENERAL SAFETY WARNINGS.
e precautions listed below are divided into the following types. ey are rather important and therefore must be followed
carefully. Meaning of DANGER, WARNING, CAUTION and NOTE symbols.
• Improper installation of the appliances or accessories can cause electric shocks, short-circuits, leaks, re or other
damage to the equipment. Make sure to only use accessories made by the supplier, which are specically designed for
the appliance and make sure that installation is performed by a skilled professional.
• All of the tasks described in this manual must be carried out by an authorised technician. During installation of the
unit or when carrying out maintenance, make sure to wear adequate personal protective equipment, such as safety
gloves and goggles.
• Contact your dealer for any type of service intervention.
iINFORMAZIONI
iINFORMATION
Caution: risk of re/ammable materials
Maintenance must only be carried out according to the instructions given by the manufacturer of the appliance.
Maintenance and repairs that require the assistance of other qualied personnel must be carried out under the supervi-
sion of a person capable of using ammable refrigerants.
AVVERTENZA
WARNING
Indicates a situation of imminent danger which, if not avoided, will cause death or serious injury.
PERICOLO
DANGER
Indicates a potentially hazardous situation which, if not avoided, could cause death or serious injury.
AVVERTENZA
WARNING
Indicates a potentially hazardous situation which, if not avoided, can cause slight or moderate injury.
It is also used to warn about unsafe practices.
ATTENZIONE
CAUTION
Indicates a situation that could only result in equipment or property damage.
NOTA
NOTE

8
Explanation of the symbols displayed on the unit.
WARNING
is symbol indicates that the appliance in question used a ammable refriger-
ant. ere is a risk of re if the refrigerant leaked or was exposed to an external
ignition source.
CAUTION is symbol indicates to carefully read the user manual.
CAUTION is symbol indicates that service personnel must handle the appliance while
referring to the installation manual
CAUTION is symbol indicates that service personnel must handle the appliance while
referring to the installation manual
CAUTION is symbol indicates that there is information available such as instructions
for use or installation instructions.
• Please switch o the power switch before touching the components of the electric terminals.
• When the service panels are removed, it is easy to mistakenly touch live components.
• Never touch the unit during installation or maintenance with the service panel removed.
• Do not touch the water pipes during and immediately aer operation as they could be hot and burn your hands. To
avoid injury, allow the pipes to return to normal temperature or put on protective gloves.
• Do not touch any switch with wet ngers. Touching a switch with wet ngers could cause electric shocks.
• Switch o the unit before touching electric components.
DANGER

9
• Tear up plastic packaging bags and throw them away so that children do not play with them. Children can risk dying
by suocation if they play with plastic bags.
• Safely dispose of packaging materials such as nails or other metal or wooden parts which could cause injury.
• Ask your dealer or qualied personnel to perform the installation jobs in compliance with this manual. Do not install
the unit on your own. Improper installation could cause water leaks, electric shocks or re.
• Make sure to use only the accessories and components specied for the installation jobs. Failure to use the specied
components could cause water leaks, electric shocks, re or cause the unit to fall o its stand.
• Install the unit on a foundation capable of bearing its weight. e appliance could fall or cause injury if not suciently
stable.
• Perform the specied installation jobs taking into account strong winds, hurricanes or earthquakes. Improper instal-
lation could cause accidents due to the equipment falling.
• Make sure that all the electrical jobs are carried out by qualied personnel in compliance with local laws and regulations
and with this manual, using a separate circuit. An insucient capacity of the power circuit or an incorrect electrical
system can cause electrical shocks and re.
• Make sure to install a ground fault circuit interrupter in compliance with local laws and regulations. Failure to install
a ground fault circuit interrupter can cause electrical shocks and re.
• Check that all the cables are rm. Use the specied wires and check that the connections of the terminals or wires
are protected against water and other outside adverse forces. An incomplete connection or fastening can cause a re.
• When wiring the power supply, position the wires so that the front panel can be xed safely. If the front panel is not
in place, there could be overheating of terminals, electric shocks or re.
• Aer having completed installation, make sure there are no refrigerant leaks.
• Never touch leaking refrigerant as it could cause frostbite. Do not touch the refrigerant pipes during and immediately
aer operation as the refrigerant inside could be hot or cold, depending on the conditions of the refrigerant owing
through the pipes, the compressor or the other parts of the refrigerant cycle. Touching the refrigerant pipes could cause
burns or frostbite. To avoid injury, allow the pipes to return to normal temperature or, if you need to touch them, put
on protective gloves.
• Do not touch the internal parts (pump, etc.) during and immediately aer operation. Contact with internal parts
can cause burns. To avoid injury, allow the internal components to return to normal temperature; otherwise, if you
absolutely need to touch them, put on protective gloves.
AVVERTENZA
CAUTION
• Placed the unit on the ground.
• e earthing resistance must comply with local laws and regulations.
• Do not connect the earth cable to gas or water pipelines, to lightning rods or the earth cables of the telephone.
• Incomplete earthing can cause electric shocks.
- Gas pipes: gas leaks could cause a re or explosion.
- Water pipes: rigid rubber hoses do not guarantee earthing.
- Lightning rods: or telephone earthing wires: the electrical threshold could increase anomalously if struck by lightning.
• Install the power cable at least 1 m away from TVs and radios to avoid interference or noise. (Depending on the radio
waves, a distance of 1 m might not be enough to eliminate noise).
• Do not use pressurised water without a large diuser. Do not use high-pressure cleaners for Cu/Cu and Cu/Al air
coils. Concentrated and/or rotating water jets are strictly prohibited. Never use uid with a temperature above 45°C
to clean the air heat exchangers. e device must be installed in compliance with the national wiring regulations. If
the power cable is damaged, it must be replaced by the manufacturer, by a service agent or by just as qualied persons
to avoid danger.
WARNING

10
• Do not install the unit in the following places:
- Where there is mineral oil mist, oil spray or vapours. e plastic components could deteriorate and cause detachment
or leakage of water.
- Where corrosive gases are produced (such as sulphurous acid gas). Where the corrosion of copper pipes or welded
parts can lead to refrigerant leaks.
- Where there is machinery that emits electromagnetic waves. e electromagnetic waves can disturb the control
system and cause the appliances to malfunction.
- Where ammable gases could escape, where the carbon bre or ammable dust is suspended in the air or where
ammable volatile substances are handled such as paint thinners or petrol. ese types of gas could cause a re.
- Where the air contains high levels of salt, like near the ocean.
- Where there is high voltage isolation, like in factories.
- In vehicles or ships.
- Where there are acid vapours or alkalines.
• is appliance can be used by children at least 8 years old and by persons with reduced physical, sensory or mental
capacities or with little experience and knowledge as long as they are supervised or receive instructions on how to use
the appliance safely and understand its risks. Children should not play with the appliance. Cleaning and maintenance
of the utility must not be carried out by children without supervision.
• Make sure that children do not use the product as a toy.
• If the power cable is damaged, it must be replaced by the manufacturer, by a service agent or by just as qualied persons.
• DISPOSAL: Do not dispose of this product as unsorted city waste. is waste must be collected separately for special
treatment. Do not dispose of electrical equipment as city waste; make use of separate collection facilities. Contact your
local government for information on available collection facilities. If the electrical equipment is disposed of in landlls,
the hazardous substances can inltrate into groundwater and enter the food chain, thus damaging your health and
well-being.
• Check the safety of the area and installation (walls, oors, etc.) without concealed dangers such as water, electricity
and gas.
• Before installation, check whether the power supply of the utility meets the electrical installation requirements of the
unit (including reliable earthing, dispersion and the diameter of the electrical load cable, etc.). If the electrical instal-
lation requirements of the product are not met, the product cannot be installed until this is rectied.
• When several units are installed in a centralised manner, please conrm balancing of the three-phase power load and
do not allow multiple units to be assembled in the same three-phase power supply phase.
• e installed product must be rmly fastened. Use reinforcement measures where necessary.
• To guarantee the safety of the product, please restart the unit at least once every 3 months so that it can perform a
self-inspection.
CAUTION
• Information on uorinated gases
- is unit contains uorinated gases. For specic information on the type and amount of gas, see the relative label on
the unit. National standards on gas must be complied with.
- Installation, service, maintenance and repair operations on this unit must be carried out by a certied technician.
- e product must be uninstalled and recycled by a certied technician.
- If the system is tted with a leak detection system, it must be checked at least every 12 months. When a leak check
is carried out on the unit, you are warmly recommended to correctly log all the controls.
NOTE

11
2
GENERAL INTRODUCTION.
• Magis M4-30 block heat pumps are used both for heating and cooling applications and for domestic hot water tanks.
ey can be coupled with fan coils, oor heating applications, low-temperature high-eciency radiators, domestic hot
water tanks and solar kits.
• e unit is supplied with a control panel.
- e maximum length of the wiring that guarantees communication between the heat pump and the control panel is
50 m.
- e power cables and communication wires are laid separately and cannot be placed in the same duct. Otherwise there
would be electromagnetic interference. e power cables and wires for communication must not come into contact
with the refrigerant pipe which at high temperatures could damage the wires.
- e communication wires must be in shielded lines, including the line that goes from the heat pump to the control
panel.
NOTE
Models 4-30
③②①Tbivalente Temperatura esterna
Capacità/carico
Capacity/load
Tbivalent Outside temperature
1) Heat pump capacity.
2) Required heating capacity (depending on site).
3) Additional heating capacity supplied by a backup heater.
Domestic hot water tank (optional)
A domestic hot water storage tank can be connected to the unit (with or without tank booster heater (TBH)
Sonda di
temperatura (T5)
Serpentino
Uscita
Resistenza
elettrica sanitario
(TBH)
Ingresso
Serbatoio
Tank
Coil
Outlet
Tank booster heater
Temperature
probe (T5)
(TBH)
Inlet
e tank booster heater (TBH) must be installed below the temperature probe (T5)
e heat exchanger (coil) must be installed below the temperature probe.
Room thermostat (optional)
e room thermostat can be connected to the unit (the room thermostat must be far away from the heating source when
the installation place is chosen).
Solar kit (optional)
A solar kit can be connected to the appliance for the domestic hot water tank.
e unit has a freezing prevention function using the heat pump to keep the water system safe from freezing in all condi-
tions. Since a power failure could occur while the unit is unattended, it is recommended to empty the system (if there is no
glycol in the water). (Chap. 9.4.4 Anti-freeze protection of water circuit).

12
Unit operating ranges 4-16 kW.
MODALITÀ DI RISCALDAMENTO DELL'ACQUA SANITARIA
T4 Temperatura esterna (°C)
Temperatura del flusso acqua (°C)
Se l’impostazione IBH è attiva, si accende solo IBH;
Se l’impostazione IBH non è attiva, si accende solo la pompa
di calore; si potrebbero verificare dei casi di limitazione e
protezione durante il funzionamento della pompa di calore.
Range di funzionamento mediante pompa di calore
con possibile limitazione e protezione.
La pompa di calore si spegne, si accende solo IBH.
MODALITÀ DI RAFFREDDAMENTO
T4 Temperatura esterna (°C)
Temperatura del flusso acqua (°C)
Range di funzionamento mediante pompa di calore
con
possibile limitazione e protezione.
MODALITÀ DI RISCALDAMENTO
T4 Temperatura esterna (°C)
Temperatura del flusso acqua (°C)
Se l’impostazione IBH è attiva, si accende solo IBH;
Se l’impostazione IBH non è attiva, si accende solo la pompa
di calore; si potrebbero verificare dei casi di limitazione e
protezione durante il funzionamento della pompa di calore.
Range di funzionamento mediante pompa di calore
con possibile limitazione e protezione.
La pompa di calore si spegne, si accende solo IBH.
Linea
di
temperatura
massima
dell'acqua
in
ingresso
COOLING MODE
T4 Outdoor temperature (°C)
Water ow temperature (°C)
Operating range by means of heat pumps with possible
restriction and protection.
Operating range by means of heat pumps with possible
restriction and protection.
e heat pump switches o, only IBH switches on.
HEATING MODE
T4 Outdoor temperature (°C)
Water ow temperature (°C)
If the IBH setting is active, only IBH switches on;
If the IBH setting is not active, only the heat pump switches
on; there could be cases of restriction and protection while
the heat pump is running.
DOMESTIC HOT WATER HEATING MODE
T4 Outdoor temperature (°C)
Water ow temperature (°C)
If the IBH setting is active, only IBH switches on;
If the IBH setting is not active, only the heat pump switches
on; there could be cases of restriction and protection while
the heat pump is running.
Operating range by means of heat pumps with possible
restriction and protection.
e heat pump switches o, only IBH switches on.

13
Unit operating ranges 18-30 kW.
MODALITÀ DI RAFFREDDAMENTO
T4 Temperatura esterna (°C)
Temperatura del flusso acqua (°C)
MODALITÀ DI RISCALDAMENTO
T4 Temperatura esterna (°C)
Temperatura del flusso acqua (°C)
Se l’impostazione IBH è attiva, si accende solo IBH;
Se l’impostazione IBH non è attiva, si accende solo la
pompa di calore;
Nessun funzionamento con pompa di calore, solo IBH
Intervallo di discesa o di risalita della temperatura di
mandata dell'acqua
MODALITÀ DI RISCALDAMENTO DELL'ACQUA SANITARIA
T4 Temperatura esterna (°C)
Temperatura del flusso acqua (°C)
COOLING MODE
HEATING MODE
T4 Outdoor temperature (°C)
Water ow temperature (°C)
T4 Outdoor temperature (°C)
Water ow temperature (°C)
T4 Outdoor temperature (°C)
Water ow temperature (°C)
DOMESTIC HOT WATER HEATING MODE
If the IBH setting is active, only IBH switches on;
If the IBH setting is not active, only the heat pump
switches on;
No operation with heat pump, only IBH
Water ow temperature descent or ascent interval

14
3
ACCESSORIES.
3.1 ACCESSORIES SUPPLIED WITH THE UNITS 416 KW.
Accessories supplied with the units
Name Shape Quantity Name Shape Quantity
Use and maintenance manual 1
Temperature probe for domestic
hot water (T5) or zone 2 (Tw2)
or thermostat controlled storage
tank (Tbt1)
1
Control Panel manual 1 Drain pipe 1
Technical data manual 1 Energy label 1
Y-shaped lter 1Tighten the clip to use the cli-
ent’s wiring
2
3
Control
check 1 Network adapter 1
SG (SMART GRID) jumper 150 kΩresistance for remote
DHW demand 1
Accessories available from the supplier
Probe for expansion tank (Tbt1) 1 Extension cable for Tw2 1
Extension cable for Tbt1 1 Solar temperature probe (Tsolar) 1
Zone 2 ow temperature probe
(Tw2) 1 Extension cable for Tsolar 1
Probes and 10 m long extensions for Tbt1, Tw2, Tsolar can be shared; if these functions are necessary simultaneously, also
order these probes and the extension cable.

15
3.2 ACCESSORIES SUPPLIED WITH THE UNITS 1830 KW.
Accessories supplied with the units
Name Shape Quantity Name Shape Quantity
Use and maintenance manual 1 Y-shaped lter 1
Control Panel manual 1Water outlet connection pipe
group 2+2
Technical data manual 1Control panel 1
Probe for domestic hot water
tank (T5)* 1Water inlet pipe adapter 1+1
Extension cable for T5 1 Network adapter** 1
Tighten the clip to use the
client’s wiring 2
SG (SMART GRID) jumper 150 kΩresistance for remote
DHW demand 1
Accessories available from the supplier
Probe for expansion tank
(Tbt1)* 1 Extension cable for Tbt1 1
Zone 2 ow temperature probe
(Tw2) 1 Extension cable for Tw2 1
Solar temperature probe (Tsolar) 1 Extension cable for Tsolar 1
* =If the system is installed in parallel, Tbt1 must be connected and installed in the expansion tank.
** =When the units are connected in parallel, for example when communication between the units is unstable (like a Hd
failure code), add a corresponding network cable between ports H1 and H2 to the terminal of the communication system.
e sensorsTbt1, T5 and the extension cable can be shared; the sensors Tw2, Tsolare and the extension wire can be shared.
If these functions are needed at the same time, customise these sensors plus the extension.

16
4
PRIOR TO INSTALLATION.
• Prior to installation.
Make sure to conrm the model name and serial number of the unit.
• Handling.
Due to the relatively large size and heavy weight of the unit, it must only be handled with liing equipment with harnessing.
e harnesses can be tted in the sleeves on the base frame, specically made for this purpose.
• To avoid injuries, do not touch the air inlet or the aluminium ns of the unit.
• Do not use the grips of the fan grilles so as not to damage them.
• e unit is very heavy! Do not allow it to fall due to an incorrect inclination during handling.
ATTENZIONE
CAUTION
Models 4-16 kW
Il gancio e il baricentro
dell'unità devono essere su
una linea in direzione verticale
per evitare un'inclinazione
impropria
Far passare la corda di
sollevamento come
rappresentato nell’immagine
≥1000mm
e hook and the centre of
gravity of the unit must be
on a vertical line to avoid an
improper inclination
Have the liing cord pass as
represented in the image
Position of the centre of gravity of the units 4-6 kW and 8-16 kW.
AA
C
B
Models 4-6 kW
C
A
B
A
Models 8-16 kW
Model A B C
Single phase 4-6 kW 296 mm 540 mm 190 mm
Single phase 8 kW 330 mm 580 mm 280 mm
Single phase 12-14-16 kW 290 mm 605 mm 245 mm
ree-phase 12-14-16 kW 200 mm 605 mm 245 mm

17
Models 18-30 kW
Far passare
le fasce come
indicato
nell’immagine
≥1000 mm
Il gancio e il
baricentro dell'unità
devono essere su
una linea in direzione
verticale per evitare
un'inclinazione
impropria
e hook and the
centre of gravity of
the unit must be
on a vertical line to
avoid an improper
Have the straps
pass as shown in
the image
inclination
5
IMPORTANT INFORMATION ON THE REFRIGERANT.
is product contains uorinated gas whose release into the air is prohibited.
Type of refrigerant: R32; Volume of GWP: 675.
GWP =Global Warning Potential
Model Volume of refrigerant loaded in the unit at the factory
Refrigerant (kg) Tonnes of CO2equivalent
4 kW 1.40 0.95
6 kW 1.40 0.95
8 kW 1.40 0.95
12 kW 1.75 1.18
14 kW 1.75 1.18
16 kW 1.75 1.18
18 kW 5.00 3.38
22 kW 5.00 3.38
26 kW 5.00 3.38
30 kW 5.00 3.38
- is unit is a hermetically sealed appliance that contains uorinated greenhouse gas.
- Installation, operation and maintenance can only be carried out by certied persons.
ATTENZIONE
CAUTION
Position of the centre of gravity of the units 18-30 kW.
304
670
425
670

18
6
INSTALLATION SITE.
• e unit is supplied with ammable refrigerant and must be installed in a properly ventilated place. If the appliance is
installed indoors, an additional refrigerant detection device must be added in addition to a further ventilation appliance
pursuant to standard EN378. Make sure to take adequate measures so that the unit is not used to house small animals.
• Animals that come into contact with electric components could cause operating failures, smoke or re. Please advise
the customer to keep the area around the unit clean.
WARNING
• Choose an installation site where the following conditions are met and which is approved by the customer.
- Well ventilated places.
- Places where the unit does not bother neighbours.
- Safe places that can bear the weight and vibrations of the unit and where it can be installed on a at surface.
- Places where ammable gas or ammable product leaks are not possible.
- e appliance is not intended to be used in potentially explosive atmospheres.
- Places where clearance for maintenance can be guaranteed.
- Places where the pipes and lengths of the wiring of the units are within the admissible limits.
- Places where the water escaping the appliance cannot damage the environment (e.g. in case of blocked drain pipe).
- Places where rain can be prevented as far as possible.
- Do not install the unit in places which are oen used as workspace. In case of construction work (for example grinding,
etc.) which creates lots of dust, the appliance must be covered.
- Do not place any object or equipment above the unit (top plate).
- Do not climb, sit or stand on the unit.
- Make sure that sucient precautions are taken in case of refrigerant leaks according to local laws and regulations on the
matter.
- Do not install the unit near the sea or in the presence of corrosive gas.
• When the unit is installed in a place exposed to strong wind, pay particular attention to the following.
Strong winds 5 m/sec or more that blow against the air outlet of the unit cause a short circuit (suction of exhaust air)
which could have the following consequences.
- Deterioration of operating capacity.
- Frequent acceleration of icing in heating mode.
- Interruption of operation due to the high pressure increase.
- When a strong wind continuously blows on the front of the unit, the fan can begin to spin so quickly that it breaks.
Under normal conditions, refer to the following gures for installation of the units 4-16 kW:
A
Unit A
4-6 kW ≥300 mm
8-16 kW ≥300 mm

19
If there is strong wind and its direction can be foreseen, refer to the gures below for installation of the unit (any of them
will do).
Turn the outlet side of the air towards the wall of the building, fence or screen.
B
Unit B
4-6 kW ≥1000 mm
8-16 kW ≥1500 mm
Make sure there is sucient space for installation.
Arrange the outlet side at a right angle with respect to the wind direction.
• Prepare a water discharge channel around the foundation, to drain the water around the unit.
• If the water has diculty owing out of the unit, mount the unit on a cement block foundation, etc. (approximately 100
mm (3.93 in) high).
• If the unit is installed on a frame, assemble a waterproof plate (about 100 mm) on the lower side of the unit to prevent
the water from entering from below.
• When the unit is installed in a place frequently exposed to snow, please pay particular attention to raise the foundation
as high as possible.
Under normal conditions, refer to the following gures for installation of the units 18-30 kW:
>300 mm

20
If there is strong wind and its direction can be foreseen, refer to the gures below for installation of the unit (any of them
will do).
Turn the outlet side of the air towards the wall of the building, fence or screen.
>3000 mm
Make sure there is sucient space for installation.
Arrange the outlet side at a right angle with respect to the wind direction.
• Prepare a water discharge channel around the foundation, to drain the water around the unit.
• If the water has diculty owing out of the unit, mount the unit on a cement block foundation, etc. (approximately 100
mm (3.93 in) high).
• If the unit is installed on a frame, assemble a waterproof plate (about 100 mm) on the lower side of the unit to prevent
the water from entering from below.
• When the unit is installed in a place frequently exposed to snow, please pay particular attention to raise the foundation
as high as possible.
• If the unit is installed on a building structure, please install a waterproof tray (about 100 mm on the bottom side of the
unit) so that the drain water does not ow out (See image below).
Other manuals for MAGIS M4-30
2
This manual suits for next models
8
Table of contents
Other Immergas Water Pump manuals
Popular Water Pump manuals by other brands

Aqua Systems
Aqua Systems Electric KFC Series instruction manual

GORMAN-RUPP PUMPS
GORMAN-RUPP PUMPS JS Series MAINTENANCE AND REPAIR WITH TROUBLESHOOTING

Teikoku
Teikoku ALP 0104QM instruction manual

SFA
SFA SANICOM 1 installation instructions

STA-RITE
STA-RITE 10DOM05121 owner's manual

STA-RITE
STA-RITE DYNA-WAVE MPRA Series owner's manual