InnoLux Viseo190W User manual

Viseo190W
Service Manual
- 0 -
Copyright
Copyright 2009 Innolux Display Corp. Ltd
All Rights Reserved
This manual may not, in whole or in part, be copied, Photocopied, reproduced, translated, or converted to any
electronic or machine readable form without prior written permission of Innolux Display Corp. Ltd.
Viseo190W Wide Service Manual
Service Manual
LCD Monitor Viseo190W

1
1
Table of Contents
Important Safety Notice ......................................................................................02
01 Product Specification .......................................................................................03
02 Flat Panel Specification ....................................................................................29
03 Exploded Diagram ............................................................................................61
04 Troubleshooting..................................................................................................66
05 Spare Parts List .................................................................................................73
06 Schematics and Layouts....................................................................................77
07 Assembly and Disassembly .............................................................................92

Viseo190W
Service Manual
2
Important Safety Notice
1. Safety precautions
This monitor is manufactured and tested on a ground principle that a user’s safety comes first. However,
improper usage or installation may cause damage to the monitor as well as to the user.
Warnings:
zThis monitor should be operated only at the correct power sources indicated on the label on the rear of the
monitor. If you’re unsure of the power supply in you residence, consult your local dealer or Power
Company.
zDo not try to repair the monitor by yourself, as it contains no user-serviceable parts. This monitor should
only be repaired by a qualified technician.
zDo not remove the monitor cabinet. There is high-voltage parts inside that may cause electric shock to
human bodies.
zStop using the monitor if the cabinet is damaged. Have it checked by a service technician.
zPut your monitor only in a lean, cool, dry environment. If it gets wet, unplug the power cable immediately
and consult your closed dealer.
zAlways unplug the monitor before cleaning it. Clean the cabinet with a clean, dry cloth. Apply
non-ammonia based cleaner onto the cloth, not directly onto the class screen.
zDo not place heavy object on the monitor or power cord.
2. Product safety notice
Many electrical and mechanical parts in this chassis have special safety visual inspections and the
protection afforded by them cannot necessarily be obtained by using replacement components rated for
higher voltage, wattage, etc. Before replacing any of these components read the parts list in this manual
carefully. The use of substitute replacement parts, which do not have the same safety characteristics as
specified in the parts list, may create shock, fire, or other hazards.
3. Service notes
zWhen replacing parts or circuit boards, clamp the lead wires around terminals before soldering.
zKeep wires away from high voltage, high temperature components and sharp edges.
zKeep wires in their original position so as to reduce interference.
zAdjustment of this product please refers to the user’s manual.

Viseo190W
Service Manual
3
01 Product Specification
1. General:
Viseo190W is designed with LVDS interface and dual (analog and digital signal) input, it featured with embedded universal AC power
supplies and audio input. It’s a green product and meets all ROHS standard. The power button and display control buttons are on the
front of the monitor. The monitors shall automatically to display lower resolution video modes into 1366X768 full screen display. The
image can be adjusted through OSD control.
1.1 Main Features
Features Specifications
Panel source AUO M185XW01 V2 0B/0C
Maximum resolution 1366X768@60Hz
Back light system 2CCFL
Actual Resolution display WXGA
Pixel pitch 0.3mm(H) x0.3mm(V)
Display area 409.8x230.4 mm
Contrast ratio 1000׃1 (typ.)
Response time (Tr+Tf) 5ms(typ.)
Viewing angle 170°/ 170° (Typ)
Monitor dimension and weight dimension :443.60*335.60*153.70mm weight : 3.72±0.3Kg
Monitor dimension and weight
(without stand and base) dimension :443.0*287.0*63.0 mm weight : 3.25 Kg
Input interface Analog(D-sub 15 pin)
Digital(24pin)(option)
A
udio-In Yes
Earphone NO
Speakers 1W+1W
Video Signal Inputs VGA+DVI(optional)
Knobs and Indicators Power switch button, MENU button, Auto button, Right button, Left button
Security Features Kensington® lock port, VESA® Wall-mountable interface, 100 mm
Power management Compatible with VESA,EPA,NUTEK,DPMS
Plug & Play VESA
University AC power supply YES
For Non-EMEA English(US),French,Italian,Spanish,German,SimplifiedChinese ,Japanese,
Traditional Chinese
For EMEA English(US), French, Italian, Spanish, German, Finnish,Hollands,Russian
OSD language
Russia Russian
Accessories
Items VGA
cable DVI
cable Audio
Cable User’s
manual Warranty
card Quick-start
Guide Installation
Guide
Description 1.8m 1.8m 1.8m Multi
●option
option ●YES
(by region) ●

Viseo190W
Service Manual
4
2. Operation Specifications
The unit should suffer no visible cosmetic damage and should operate with no degradation in display quality during exposure to the
operating conditions and after exposure to the non-operating conditions, in any sequence.
2.1 Environmental conditions
Operating Specification
Temperature range 0°C to 40°C
Relative humidity 20% to 80%
Altitude 0 to 3048M (10000 ft)
Storage
Temperature range -25°C to 60°C
Relative humidity 5% to 80%
Altitude 0 to 9144M (30000 ft)
2.2 Safety, EMC, Ergonomics and Compatibility Requirements
Items Description
UL/cUL CB Bauart CCC Other
Safety ●●
FCC CE CCC VCCI BSMI
EMC ●
MPRΠISO9241-30
Ergonomics ●●
Windows 95/98/Me Windows 2000 Windows XP vista
Compatibility ●●●●
Energy Star
Power
Management ●
2.3 Electrostatic Discharge Requirements
Item Condition Spec
Contact discharge : +4KV
Contact discharge : +8KV ●
Air discharge : + 8KV
Electrostatic Discharge IEC61000-4-2(EN55024)
Air discharge : +15KV ●
2.4 Reliability
Items Condition Spec Note
MTBF 25degree 50,000Hours
CCFL Life time Luminance becomes 50% 50,000 Hours(Typ) Note1
Note1. Display an all WHITE field at mid Brightness and Contrast settings.

Viseo190W
Service Manual
5
3. Electrical and Optical Characteristics and Performance
3.1 Main Power Supply
3.1.1 Input characteristics
Items Condition Spec Note
AC Input Voltage range Universal input full range 90~264Vac
AC Input Voltage rating Universal input full range 100~240Vac
AC input frequency range 90~264Vac 47~63Hz
AC input frequency rating 100~240Vac 50~60Hz
100Vac 1.0A(max)AC Input Current
240Vac 0.6A(max)
115Vac,cold star,25°C 35A (max)
Inrush Current
230Vac,cold star,25°C 70A(max)
See Note2
AC-DC power Efficiency DC output full loading ≥75%
Note2.Before each test, the buck capacitor need to be discharged.
Before each test, it must be 10 minutes at least after the latest test.
Hotstarnotcomponentbedamaged.
3.1.2 Output characteristics
Items Condition Spec Note
+14.2 output(PWM mode) <1000mv
+14V output(linear mode) <400mv
+5V output <150mv
Ripple and Noise
audio 5V output <300mv
See note 3
14v loading:0.2A~1.0A
5v loading:0. 5A~1.2A
audio 5v loading:0A~0.8A
VccV:13.5V~16.3V
Vcc5V:4.95V~5.45V
audio 5v:4.5V~5.5V
For system
active
DC Output Voltage 5v loading:0.04A~1.2
A
14V loading: 0A
audio 5v loading:0A
Vcc5V: 4.85V~5.45V
Vcc14V: 13.5V~20V
audio 5v:4.5V~5.5V
For power
saving or DC
off
DC output loading capability Vcc5V/1.2A
Vcc14V/1.0A
audio 5V/0.8A
Rise Time <20mS
Dynamic load change
Hold-up time AC input: 100V~240V >10mS
Overshoot <10%
Turn on delay time >1S
Power management See Table-1
Note3: Paralleled a 0.1uF ceramic Cap. And 47uF aluminum Cap. Between the end of DC loading side,
Measured band-width=20MHz. The sine wave signal that the frequency is 1K Hz input when testing the ripple for the 5V of audio.
The ripple of 24 out put is 1500mV in burst mode.

Viseo190W
Service Manual
6
3.1.3 Protection characteristics
Protection Condition Spec
OPP >37W
Table-1
Status H-sy
nc
V-sy
nc Video Power LED
Power On(with audio)on on active <34W White
off on blanked < 1W White flicker
on off blanked < 1W White flicker
Power Saving
off off blanked < 1W White flicker
Power Off -- -- -- < 1W Off
3.1.4 Backlight Power Supply
Items Spec
Lamp 2 CCFLs
Input Voltage 13.5V~16.3V
Input current 0.8A (Typ.), 1.0A (Max.)
On/Off switch level 5.5V≧Von≧2.0 V (on)
-0.3v ≤Voff ≤0.8 V (off)
Brightness control voltage 30%~100% (ACM Off)
10%~100% (ACM On)
CCFL operating Voltage 700Vrms(Typ)
2.0 mA (min)
7.5 mA (Typ.)
CCFL Current
8.0mA (Max.)
CCFL startup voltage ≧1700Vrms (0˚C)
Operating frequency 40~70 KHz
Protect delay time > 1 second
Efficiency ≥75%
3.2 Input / Output Signal Specifications
3.2.1 Video signals
Items Condition Spec OK Note
15 pin D-Sub Color: BLACK
Length: 1800 +/- 20 mm ●Monitor side should be
blue right angle.
Signal Cable DVI-D Color: BLACK
Length: 1800 +/- 20 mm NO DVI cable in carton
Signal type Separate analog R,G,B ●For 15 pin D-sub
Level 700 mV +/- 5% (peak to
peak) ●
Analog Impedance 75 Ohms +/- 2% Ohms ●

Viseo190W
Service Manual
7
Digital Base on TMDS technology
●
Signal type Separate H/V-sync
(Positive/Negative) ●For 15 pin D-sub
Level Logic High: 2.0V ~ 5.5V
Logic Low: 0V ~ 0.8V
(TTL level)
●Refer to VESAVSIS
Standard V1R1
Sync
Terminal ≧2.2kΩ●2.2KΩfor application
3.2.2 Signal Timing
For input timing range, this unit can support FH= 31 ~ 83 KHz, Fv=56 ~ 75Hz.
Modes details as below:
VESA MODES
Horizontal Vertical
Mode Resolution Total Nominal
Frequency
+/-0.5KHz
Sync
Polarity
Nominal
Frequency
+/-1Hz
Sync
Polarity
Nominal
Pixel Clock
(MHz)
640*480@60Hz 800*525 31.469 N 59.941 N 25.175
640x480@72Hz 832 x 520 37.861 N 72.809 N 31.500
VGA
640x480@75Hz 840 x 500 37.500 N 75.000 N 31.500
800*600@56Hz 1024*625 35.156 P 56.250 P 36.000
800*600@60Hz 1056*628 37.879 P 60.317 P 40.000
800*600@72Hz 1040 x 666 48.077 P 72.188 P 50
SVGA
800x600@75Hz 1056x625 46.875 P 75.000 P 49.500
1024*768@60Hz 1344*806 48.363 N 60.004 N 65.000
1024*768@70Hz 1328*806 56.476 N 70.069 N 75.000
XGA
1024*768@75Hz 1312x800 60.023 P 75.029 P 78.75
VESA 1152x864@75Hz 1600x900 67.5 P 75 P
108
XGA 720*400@70Hz 900*449 31.469 N 70.087 P
28.322
MAC MODES
VGA 640*480@66.7Hz 864*525 35.000 P66.667 P 30.240
VGA 832x624@74.55Hz 1152x667 49.722 N 74.55 N 57.28
VGA 1152x870@75Hz 1456x915 68.681 N 75.062 N 100
Other MODES
WXGA+ 1280*720@60Hz 1650x750 44.955 P 59.940 P 74.176
VESA 1280x960@60HZ 1800x1000 60.000 P 60.000 P 108.000
1280x1024@60HZ 1688x1066 63.981 P 60.020 P 108.000
SXGA
1280x1024@75HZ 1688x1066 79.976 P 75.025 P 135.000
1280x800@60HZ 1680x831 49.702 N 59.810 P 83.500
WXGA
1366x768@60HZ 1792x795 47.712 P 60.015 P 85.500
Note: 1. Non-interlace signals only (An interlace signal cannot be display)
2. Please refer to F/W specification for more detail
3. Each frequency of Power Macintosh and Sun Ultra is a reference value

Viseo190W
Service Manual
8
3.2.3 Timing requirements
Scan Frequency Condition Specification
Horizontal Sync polarity: (+) or (-) 30~60 KHz
Vertical Sync polarity: (+) or (-) 55~75Hz
Out of range
Excluding
Horizontal 31~83 KHz or
Vertical 56~76Hz
Message “Input Not Supported” on screen
Note: 1. Move around the full screen
2. Desktop background in black
3. Frequency out of range menu will display 5 minutes, then enter power saving status.
3.2.4 DDC datas
EDID Standard Compliance
EDID File Format : VESA’s EDID Standard Version #3, Revision #0,
EDID Structure : Version #1, Revision #3.
EDID Data Table : See the file of LE19S8-DR4-16
4. LCD Characteristic & Performance
4.1 Panel general specifications
General Specifications
(1) The test methods for the below items’ definition, please refer to the specification of AUO M185XW01 V2 0B/0C panel
Supplier AUO
Model name M185XW01
Display Area 409.8( H ) x 230.4( V )
Pixel Pitch 0.3mm(H) x 0.3mm(V)
Display Colors: 16.7 Million (6-bit + Hi-FRC)
Number of Pixel 1366x768 pixels
Pixel Arrangement RGB vertical stripe
Brightness 250cd/m2@7.5mA(Typ.)
Contrast Ratio 1000:1 Typical
Viewing Angle 170°(L)/ 170°(R),
(Typical, CR=10)
Display Mode Normally White
Frame rate 60Hz Typical
Response Time Tr + Tf = 5ms Typical (8ms Max.)
Surface Treatment Anti-glare, Haze = 25%,
Hard coating (3H)
Lamp 2 CCFL
Outline Dimension 430.37(W)x254.6(H)x16.5(D)mm(Max)
Notes: Other panel source, please refer to the panel specifications.
4.2 Optical characteristic of LCD panel

Viseo190W
Service Manual
9
(1) The test methods for the below items’ definition, please refer to the specification of AUO M190PW01 V0 00/0B panel.
Item Unit Conditions Min. Typ. Max. Remark
Viewing Angle [degree]
[degree] Horizontal (Right)
CR >= 10 (Left) 75
75 85
85 -
-
[degree]
[degree] Vertical (Up)
CR >= 10 (Down) 70
70 80
80 -
-
Contrast ratio Normal Direction 600 1000
Response Time [msec] Rising Time - 3.6 5.7
[msec] Falling Time - 1.4 2.3
[msec] Rising + Falling - 5 8
Color / Chromaticity Red x 0.650
Coordinates (CIE) Red y 0.335
Green x 0.295
Green y 0.605
Blue x 0.145
Blue y 0.075
White x 0.313
Color Coordinates (CIE) White White y
Typ-0.03
0.329
Typ+0.03
Luminance Uniformity [%] 9 points measurement 75 80
White Luminance at
CCFL 7.5mA(center point) [cd/m2]
200 250 -
4.3 Brightness output
The test to verify specifications in this section shall be performed under the following standard conditions unless otherwise
noted.
Temperature : 25 ± 5°C
Test pattern : white
Video Resolution : 1366x768
Video input level : 700 mV ± 2%
Warm-up time : 30 minutes
Item Condition SPEC
Brightness=100%
Brightness Contrast = 100% ≧200 cd/m2
Brightness=100%
Grey Scale Contrast = 100%
the last 3~8 levels of 32
grey scales is combined
4.4 White balance
The test standard conditions refer to Sec 3.3. (Brightness control is at 100 contrast control is at 50.)
Chromaticity Coordinate
Mode x y
Cool 9300K 0.283 ± 0.030 0.297 ± 0.030
Warm 6500K 0.313 ± 0.030 0.329 ± 0.030
User Panel While x Panel While y

Viseo190W
Service Manual
10
4.5 Brightness uniformity
The test standard conditions refer to Sec 3.4.
%75
≥
)(backlightpointsnineofluminanceMax. )(backlightpointsnineofluminanceMin. (4)
Fig.3
4.6 Audio Signal
Items Specification
Input impedance ≧10K ohm
Frequency response range 200Hz –20kHz
Signal to noise ratio ≧40 dB
Output power ≦1 W + 1 W(±20% tolerance), THD 10%.
Loading impedance 4 ohm
Note: The low pass RC Filter (R=100Ω/ C=0.047uF) for Class-D output power and THD+N measurement, and under 1KHz, 1Vrms
and sine wave input.
5. Function Specifications
All the tests to verify specifications in this section shall be performed under the following standard conditions unless otherwise
noted. The standard conditions are:
Temperature : 25 ± 5°C
Warm-up time : 30 minutes minimum
Checking display modes : All the specified modes
1 2
5
7 9
L/2 L/10
W/10
W/2
3
4 6
8

Viseo190W
Service Manual
11
5.1 Keypad Function
5.1.1 Control buttons
[AUTO]
A. When OSD un-displays, press [AUTO] to show “auto-adjustment”
B. When OSD displays, press [AUTO] to return to previous level menu
[MENU]
A. When OSD isn’t shown on screen, press [MENU] to enter OSD interface. The OSD
interface uses “Scenario Mode” and “User” to instead “Contrast” and “Brightness”
separately. When press “Scenario Mode” to show “Scenario Mode” OSD, and press
“User” to show OSD interface before. The translations of “Scenario Mode” and “User”
are always English.
B. When OSD displays, press [MENU] to perform function of menu icon that is highlight or
enter next level menu
[►], [◄]
A. When “MENU OSD” displays, press these keys to change the contents of an
adjustment item, or change an adjustment value
B. When “MENU OSD” un-displays, if it is with audio, press [►] to show “Audio” OSD
and increase the volume, press [◄] to show “Audio” OSD and decrease the volume;
else it has no use to press these keys.
[POWER] Power on or power off the monitor
5.1.2 Hot Key Operation
HOT KEY OPERATION
FUNCTION
AUTO MENU ◄►POWER
DESCRIPTION
FACTORY
MODE ●
ON
Press [AUTO], and then press [POWER] for DC
power on. OSD menu will be shown with “F” on
the left top. Select “F” for entering factory mode.
5.2 OSD Structure
The On-Screen Display (OSD) shall be an easy to use icon based menu through keypad OSD buttons or remote control unit. The unit shall
leave the factory with all OSD controls set to their default values.
First Second Third Control Range Default Value
Scenario Mode Scenario
Mode ---
Standard mode
User mode 50
Text mode 50
Standard mode 50
Graphics mode 60
Contrast 0 ~ 100
Movie mode 56
User mode 77
Text mode 44
Standard mode 77
Graphics mode 97
Brightness 0 ~ 100
Movie mode 77
Brightness
User
ACM ON/OFF OFF
Image Focus --- 0 ~ 100 Depend on each timing

Viseo190W
Service Manual
12
Clock --- 0 ~ 100 50
H. Position --- 0 ~ 100 50
Position
V. Position --- 0 ~ 100 Depend on each timing
Warm (6500K) --- ---
Cool (9300K) --- ---
Red 0 ~ 100 80
Green 0 ~ 100 80
Color
User
Blue 0 ~ 100 80
NO-EMEA EMEA
English English --- ---
Deutsch Deutsch --- ---
Español Español --- ---
简体中文 Hollands --- ---
繁體中文 Русский --- ---
Français Français --- ---
Italiano Italiano --- ---
Language
日本語 Suomalainen --- ---
English
H. Position --- 0 ~ 100 50
V. Position --- 0 ~ 100 50
OSD
OSD Timeout --- 10~ 120 20
Wide mode Full/Aspect Full
Input (Analg
only)
DDC/CI ON/OFF ON
Input source D-Sub/ DVI-D
Wide mode Full/Aspect Full
Input(dual)
DDC/CI ON/OFF ON
Resolution --- --- ---
H. Freq --- --- ---
V. Freq --- --- ---
Analog Input/ Digital Input --- --- ---
Info
S/N ET000….0000(22)
Reset --- --- --- ---
Exit --- --- --- ---
Notes: ○
1Clock default 50 is for Visa timing. Others depend on timing.

Viseo190W
Service Manual
13
6. SOP of PCBA ISP Programming(The SOP of E182H/E192HQ, E202H,E191W are the same)
6.1 Operational condition:
Equipment: PC, ISP card, signal cable and power cable.
ESD requirements: antistatic wrists, antistatic gloves(fingers), and connecting cable
Name of ISP program: DebugTool_V6.4.exe
Manufacture of FW IC:RTD 2120
6.2 Operational steps:
1. Connection: connect PC to PCBA with signal cable, and then keep AC and DC in open state.
2. Adjust ISP programming
Firstly, double click DebugTool_V6.4.exe and open ISP program, then select “RTD2120”, and ISP
button.
Secondly﹐select Bank2 size which is 30.
Signal cable
One port of ISP
program card is
connected to PC
Click ISP
button

Viseo190W
Service Manual
14
Thirdly, click “64K”button and load FW file,and it will load extend FW automatically as below Figure 3.
Fourthly, click “program”button as below,then you will see the Checksum. Figure 4 .
Select Bank2 size:

Viseo190W
Service Manual
15
Fifthly, Program process as below.
Click this button
to program

Viseo190W
Service Manual
16
Note: Please see the configure as below Figure 6.
Configure
Inform

Viseo190W
Service Manual
17
3. Flow Chart
◆Flowin
g
chart
After connecting,
AC ON, DC ON
Open ISP program
Choose manufacturer
and model of FW IC
LOAD FW files
Click program
button
Beginning
programming
Turn off power if
programming is OK
OK
OK
OK
OK
OK
OK NG
Choose Config and
adjust
programming

Viseo190W
Service Manual
18
7. SOP of EDID
7.1 Request of hardware and software:
1. Software
a.port95nt.exe
b.Edid.exe
c.Viseo190W model
2. Hardware
a.PC(winXP or win2000)1PCS;
b.Tool(EDID Card、VGA cable & DVI cable)
7.2 Operational steps:
1. First set up Port95nt.exe

Viseo190W
Service Manual
19
2. Click next button continually then can finish setting.