Interlogix ITI SuperBus 2000 User manual

International
Installation Instructions
1
About this Document
This document describes how to install and test the ITI®
International SuperBus®2000 Hardwire Output Module
(HOM). For HOM programming and operating details,
refer to the installation instructions for your security panel.
Note
The panel installation instructions and touchpad
displays may refer to HOM relays as outputs or output
points. The terms are interchangeable. This document
uses the term “relay” to avoid confusion in the wiring
diagrams, because the terminals of the HOM are
labeled RELAY 1, RELAY 2, etc.
Product Summary
The HOM expands the versatility of compatible panels by
adding four programmable outputs. These include both nor-
mally open and normally closed dry relay contact outputs.
The HOM also includes one input zone for hardwire sen-
sors. This input is monitored (using an end-of-line resistor
[EOL]) and the HOM alerts the panel if there is an open or
short circuit.
You can add up to 16 SuperBus 2000 devices to one Inter-
national Concord™security panel.
A built-in cover tamper switch provides additional security.
Examples of HOM output uses include the following:
❑Turning on a closed-circuit television (CCTV) camera
during a burglary alarm.
❑Turning on exit lights during a fire alarm.
❑Activating backup cellular phones or long-range radios
if primary communications are inoperable.
HOM Components
The HOM module comes complete with mounting hard-
ware. Power is provided by the panel.
❑Figure 1 shows the main HOM components. Table 1
describes these components
Figure 1. HOM Circuit Board Components
Installation Guidelines
❑The International Concord security system supports up
to 16 SuperBus 2000 devices.
❑Do not exceed the total DC power rating of the panel
when using panel power for bus devices and hardwired
sensors that require panel power (see the specific panel
installation instructions).
Important !
If separate power supplies are necessary to accom-
modate the HOM modules, safety standards require
that each power supply be prominently marked with
adequate instructions for removing all power from the
unit.
Table 1: HOM Component Descriptions
Component Function
Red light-emitting
diode (LED) Flashes to indicate normal
communication to the panel bus.
Green LED Indicates power is on.
Output relays Form C (dry contact) output relays.
Terminal strip Used for SuperBus 2000 and output
wiring connections.
Cover Tamper Switch Alerts the panel if the HOM cover is
removed.
SuperBus 2000 device
ID Label Identifies the unique device ID number
assigned to each ITI SuperBus 2000
module
TERMINAL
STRIP
OUTPUT
RELAYS (4)
RED LED
GREEN LED
NC CO M NO NC CO M NO NC CO M NO NC COM NO
R E L A Y 1 R E L A Y 2 R E L A Y 3 R E L A Y 4
+12V
BUSA
BUSB
GND
ZO N E 1
ZC O M
COVER
TAMPER
SWITCH
SUPERBUS 2000
ID LABEL
Document Number: 466-1778 Rev. A
August 2000
8557109A.DS4
ITI Part No. 60-770-01

2SuperBus® 2000 Hardwire Output Module (HOM)
Tools and Supplies Needed
❑Maximum HOM current draw with all relays energized
is 180 mA. Each HOM typically draws 25 mA when
relays are not energized (idle) and an additional 39 mA
per energized relay.
❑Do not exceed the HOM output relay contact ratings
(see the specifications section at the end of this docu-
ment).
❑Use 4-conductor, 22-gauge or larger stranded wire
from the HOM to the panel.
❑Use 22-gauge or larger stranded wire from the HOM to
the output devices. Refer to the panel installation
instructions for wire length limitations.
❑If you are replacing an existing HOM, then you must
delete the existing HOM information from panel mem-
ory before installing this HOM. See the panel installa-
tion instructions for details.
Tools and Supplies Needed
❑Screwdriver
❑4 self-tapping screws (included)
❑4 #6 plastic wall anchors (included)
❑22-gauge or larger stranded hookup wire
Installation
The SuperBus 2000 HOM can be mounted
❑on a wall, or
❑inside a SuperBus Accessory Enclosure, or
❑inside a metal Concord cabinet.
To comply with safety standards, the HOM module, or the
cabinet in which the HOM module is mounted, must be
secured to the building structure before operation.
CAUTION
To prevent damaging the panel or card, remove AC
power from the panel and disconnect the backup
battery before installation.
Note
You must be free of all static electricity when handling
electronic components. Touch a bare metal surface
before touching the circuit board.
Mounting the HOM in a SuperBus
Accessory Enclosure
1. Remove AC power from the panel and disconnect the
backup battery.
2. Remove the HOM cover and set it aside (Figure 3).
3. Place the back plate inside the cabinet and line up the
module mounting holes with the cabinet mounting
holes (Figure 2).
Figure 2. SuperBus Accessory Enclosure
(cover not shown)
4. Secure the back plate to the cabinet with four #6-32
self-tapping screws as shown.
Mounting the HOM in a Concord Cabinet
1. Remove AC power from the panel and disconnect the
backup battery.
2. Remove and discard the HOM cover (Figure 3).
Figure 3. Removing the Cover
3. Open the panel cabinet cover.
4. Slide the module backplate onto the two module
mounting clips located on the top-left, top-center, or
top-right corner of the cabinet (Figure 4).
PRESS DOWN
HERE AND PULL
AWAY FROM BASE
8557G47B.DS4

3
SuperBus® 2000 Hardwire Output Module (HOM)
Wiring
Figure 4. Mounting the Module in a Concord Cabinet
5. Install the supplied standoff between the module
backplate and the circuit cards
Mounting the HOM on a Wall
1. Remove AC power from the panel and disconnect the
backup battery.
2. Remove the HOM cover and set it aside (Figure 3).
3. Place the back plate on the wall and mark the mounting
holes (Figure 5).
Figure 5. HOM Mounting Holes
4. Drill holes and insert appropriate anchors.
5. Secure the back plate to the wall with panhead screws.
Wiring
This section describes how to wire the HOM to an Interna-
tional Concord security panel and how to wire various
devices to the HOM terminals.
To wire the HOM to a panel:
1. Remove AC power from the panel and disconnect the
backup battery.
2. Wire the HOM to the panel as shown in Table 2 and
Figure 6. For specific SuperBus 2000 wiring details,
see the panel installation instructions.
To wire output devices to the HOM
Wire the HOM supervised hardwire input zone as shown in
Figure 6. For specific output device wiring details, see the
output device installation instructions. (Example HOM
applications and wiring are provided later in this docu-
ment.)
Module Tamper Detection
If the panel is programmed to detect tampers, the cover
tamper switch will cause an alarm when the HOM cover is
opened. See the panel installation instructions for details.
SUPERBUS
MODULE
MOUNTING
CLIPS (6)
S
UPERBUS
MODULE
(COVER
REMOVED)
PANEL CABINET
(COVER NOT SHOWN
)
MOUNTING HOLES (4)
NC COM NO NC CO M NO N C COM NO NC COM NO
R E L A Y 1 R E L A Y 2 R E L A Y 3 R E L A Y 4
+12V
BUSA
BUSB
GND
ZO N E 1
ZC O M
USA
BU
COVER
TAMPER
SWITCH
Table 2: HOM to Panel Wiring Guide
HOM Terminals +12VDC BUS A BUS B GND
International
Concord Terminals 1234

4SuperBus® 2000 Hardwire Output Module (HOM)
Power-Up and Bus Communication
Figure 6. HOM Hardwire Input Zone Wiring
Power-Up and Bus Communication
This section describes how to power up the panel and the
HOM and get them communicating with each other.
To power up the panel and the HOM and verify bus
communication:
1. Verify that all wiring between the panel, touchpad, and
HOM is correct.
2. Connect the panel battery and restore AC power to the
panel. Alphanumeric touchpad displays should
momentarily indicate:
SCANNING BUS DEVICES
Note
The International Concord security panel scans and
automatically “learns” the device ID number of each
bus device when the panel is first powered up. The
panel then assigns a unique “address” to each bus
device.
3. Enter program mode by pressing 8+ installer code
(default = 54321) + 0+ 0. The touchpad should
display:
SYSTEM PROGRAMMING
4. Press ƒand the display shows
SECURITY
.
5. Press Aor Buntil the display shows
ACCESSORY
MODULES
, and then press ƒ. The display should read:
BUS DEVICES
6. Press ƒ. The display shows unit number 00 and its
device ID number.
7. Press Aor Bto cycle through all bus device unit
numbers until the HOM appears. For example:
UNIT - ID
06 - NNNNNNNN
where 06 is the unit number assigned by the panel and
NNNNNNNN is the device ID number on the HOM
SuperBus 2000 device ID label.
Note
If the HOM ID does not appear, remove AC power
from the panel, disconnect the backup battery, and
verify that all wiring is correct.
8. Verify the HOM device ID number by checking it
against the SuperBus 2000device ID label on the HOM
circuit board.
9. Use the information in the panel installation
instructions to configure the HOM, then press ‚
repeatedly until the display shows
SYSTEM PROGRAMMING
10. Press Aor Buntil the display shows
EXIT PROGRAMMING READY
11. Press ƒto exit the program mode. The display shows
the day, date, and time. The green LED of the HOM
should be on to indicate power and the red LED should
be flashing to indicate successful communication with
the panel.
Note
If the red LED is not flashing, remove AC power from
the panel, disconnect the backup battery, and verify
that all wiring is correct.
Programming the HOM Input Zone
The HOM input zone must be entered (learned) into the
memory of the International Concord security panel. See
the panel installation instructions for details.
Programming HOM Outputs
The HOM receives pre-programmed output commands
from the panel via the SuperBus 2000 data connection, then
energizes the appropriate HOM relay. Relay operation, time
delay, and duration are determined by the panel program-
ming. See the panel installation instructions for details.
1 COM
1 N/C
1 N/O
2 COM
2 N/C
2 N/O
3 COM
3 N/C
3 N/O
4 COM
4 N/C
4 N/O
+12 VDC
*
(RED)
BUS A (GRN)
BUS B (WHT)
GND (BLK)
TO OUTPUT
4 DEVICE
TO OUTPUT
3 DEVICE
TO OUTPUT
2 DEVICE
TO OUTPUT
1 DEVICE
TO PANEL
SUPERBUS
TERMINALS
OR
CONNECTOR
*
ALSO OUTPUT AND OTHER SUPPLY
NC COM NO NC CO M NO NC CO M NO NC CO M NO
R E L A Y 1 R E L A Y 2 R E L A Y 3 R E L A Y 4
+12V
BUSA
BUSB
GND
ZO N E 1
ZC O M
ZONE 1
ZCOM
NORMALLY
OPEN
(N/O)
CONTACTS
IN PARALLEL
2k Ohm
EOL RESISTOR
49-365
NORMALLY
CLOSED
(N/C)
CONTACTS
IN SERIES

5
SuperBus® 2000 Hardwire Output Module (HOM)
Application Examples
Application Examples
The following sections provide some examples of typical
applications to assist you in configuring the HOM to your
specific applications.
CCTV Camera Control Output Example
The following is an example of a CCTV camera controlled
by a burglary alarm.
To wire the HOM to a CCTV camera:
1. Remove AC power from the panel and disconnect the
backup battery.
2. Wire the HOM module to the panel (see Table 2 and
Figure 7).
3. Wire the HOM relay 1 COM and N/O outputs to the
camera (or camera multiplexer control) as shown.
4. Restore AC power to the panel and reconnect the
backup battery.
Figure 7. Connecting a CCTV Camera to the HOM
5. At the panel, select the desired partition and set HOM
relay 1 to trigger on sensor 1 activity (for example,
motion detector learned as sensor 1) and have a 3
minute response. This would be HOM configuration
code 25701.
LED Indicator Output Example
The following is an example of an LED indicator used to
show an arming status condition.
To wire the HOM and LED indicator:
1. Remove AC power from the panel and disconnect the
backup battery.
2. Wire the HOM module to the panel (see Table 2 and
Figure 8).
3. Wire the LED and the appropriate current limiting
resistor in series with the output as shown.
4. Restore AC power to the panel and reconnect the
backup battery.
Figure 8. Connecting an LED Indicator to the HOM
5. At the panel, select the desired partition and set HOM
relay 1 to trigger on arming levels 2 or 3 with a
sustained response. This would be HOM configuration
code 00903.
CAMERA
RUN/PAUSE
INPUT OR
CAMERA
MULTI-
PLEXER
INPUT
CCTV
CAMERA
SUPERBUS 2000
HOM
+12 VDC
BUS A
BUS B
GND
N/C
COM
N/C
N/O
COM
N/O
RELAY
2
RELAYS
3-4
RELAY
1
TO VIDEO
MONITOR/
RECORDER
NOTE: DO NOT EXCEED RELAY CONTACT
VOLTAGE AND CURRENT RATINGS
PANEL
SUPERBUS
TERMINALS
(SEE TABLE)
SUPERBUS 2000
HOM
+12 VDC
BUS A
BUS B
*
2.4 K ohm 1/2 W
(TYPICAL)
LED
GND
9064a40.D S 4
N/C
COM
N/C
N/O
COM
N/O
RELAY
2
RELAYS
3-4
RELAY
1
NOTE: DO NOT
EXCEED OPEN
COLLECTOR
VOLTAGE AND
CURRENT
RATINGS
*DO NOT EXCEED PANEL +12V POWER CONSUMPTION
LIMITS (SEE PANEL INSTALLATION INSTRUCTIONS)
PANEL
SUPERBUS
TERMINALS
(SEE TABLE)

6SuperBus® 2000 Hardwire Output Module (HOM)
Application Examples
Wireless Overhead Door Control
Output Example
The following is an example of a wireless keychain touch-
pad(s) used to control an overhead door.
Note
This procedure would affect the “star” key of ALL
wireless keychain touchpads entered (learned) into
the system.
To wire the HOM and overhead door control:
1. Remove AC power from the panel and disconnect the
backup battery.
2. Wire the HOM module to the security panel
(see Table 2).
3. Wire the HOM Relay 1 COM and N/O outputs in
parallel with the overhead door operator control as
shown in Figure 9.
4. Restore AC power to the panel and reconnect the
backup battery.
Figure 9. Connecting an Overhead Door Operator to
the HOM
5. At the panel, select the desired partition and set HOM
relay 1 to trigger on a wireless keychain star button and
have a momentary response. This would be HOM
configuration code 01400.
Long-Range Radio Communications
Backup Output Example
The following is an example of a long-range radio used as a
communications backup in case of a Failure-To-Communi-
cate (FTC) response from the panel if, for example, the
phone lines are inoperable.
To wire the HOM to a long-range radio:
1. Remove AC power from the panel and disconnect the
backup battery.
2. Wire the HOM module to the security panel
(see Table 2).
3. Wire the HOM Relay 1 COM and N/O outputs to the
long-range radio as shown in Figure 10.
4. Restore AC power to the panel and reconnect the
backup battery.
Figure 10.Connecting a Long-Range Radio to the HOM
5. At the panel, select the desired partition and set HOM
relay 1 to trigger on a fail to communicate (FTC)
condition and to have a sustained response. This would
be HOM configuration code 01203.
9064a41.D S F
NOTE: DO NOT EXCEED RELAY CONTACT
VOLTAGE AND CURRENT RATINGS
OPEN/CLOSE
SWITCH
SUPERBUS 2000
HOM
+12 VDC
BUS A
BUS B
GND
N/C
COM
N/C
N/O
COM
N/O
RELAY
2
RELAYS
3-4
RELAY
1
GARAGE
DOOR OPERATOR
CONTROL
WIRELESS
KEYCHAIN
TOUCHPAD
PANEL
SUPERBUS
TERMINALS
(SEE TABLE)
9064a42.D S F
680 ohm
1/2 w
(TYPICAL) LONG-RANGE
RADIO
ZONE X
SUPERBUS 2000
HOM
+12 VDC
BUS A
BUS B
*
GND
N/C
COM
N/C
N/O
COM
N/O
RELAY
2
RELAYS
3-4
RELAY
1GND
(COMMON)
NOTE: DO NOT EXCEED RELAY CONTACT
VOLTAGE AND CURRENT RATINGS
*DO NOT EXCEED PANEL +12V POWER CONSUMPTION
LIMITS (SEE PANEL INSTALLATION INSTRUCTIONS)
PANEL
SUPERBUS
TERMINALS
(SEE TABLE)

7
SuperBus® 2000 Hardwire Output Module (HOM)
Testing the HOM Operation
4-Wire Smoke Detector (with Power
Reset) Example
The following is an example of a 4-wire smoke detector
with power reset application.
To wire the HOM and 4-wire smoke detector
1. Remove AC power from the panel and disconnect the
backup battery.
2. Wire the HOM module to the security panel SuperBus
2000 terminals as shown in Table 2.
3. Wire the HOM Relay 1 COM and N/C terminals to the
smoke detector terminals and Power Supervision
Module wires as shown in Figure 11.
4. Wire the smoke detector output terminals to the Power
Supervision Module wires and then to any of the
unused panel zone inputs and zone input common
terminals as shown in Figure 11.
5. Restore AC power to the panel and reconnect the
backup battery.
6. At the panel, select the desired partition and set HOM
relay 1 to trigger on a smoke power condition and have
a momentary response. This would be HOM
configuration code 01500.
Figure 11.Connecting a 4-Wire Smoke Detector to the
HOM and Concord Security Panel
Testing the HOM Operation
To test the HOM operation, activate each of the pro-
grammed system triggering events and check that the
desired HOM relays respond.
The HOM status LED (red) should blink regularly when
communications to and from the panel (through the Super-
Bus 2000 data connections) are correct.
Troubleshooting the HOM
Use Table 3 to determine possible solutions to HOM prob-
lems.
9064a43.D S F
4-WIRE SMOKE
DETECTOR
SUPERBUS 2000
HOM
+12 VDC
BUS A
BUS B
*
GND
N/C
COM
N/C
N/O
COM
N/O
RELAY
2
RELAYS
3-4
RELAY
1
*DO NOT EXCEED PANEL +12V POWER CONSUMPTION
LIMITS (SEE PANEL INSTALLATION INSTRUCTIONS)
PANEL
TERMINALS
(SEE TABLE)
ZONE
INPUT
+12VDC
GND
OUT
POWER SUPERVISION
MODULE **
ITI PART #60-798
NOTE: DO NOT EXCEED RELAY CONTACT
VOLTAGE AND CURRENT RATINGS
**LOCATE AT LAST DEVICE. CONTAINS INTERNAL 2.0 K
END-OF-LINE RESISTOR BETWEEN GREEN AND WHITE)
Table 3: Troubleshooting the HOM
Problem Solution
The green
POWER LED
stays off.
1. Check for incorrect wiring connec-
tions.
2. Make sure the panel AC power is on
and the backup battery is connected.
3. If the LED still remains off, replace
the module.
The red BUS
LED doesn’t
flash to indicate
communication
between the
panel and the
HOM.
1. Verify that the panel recognizes the
module by entering program mode
(see specific panel installation instruc-
tions).
2. Check for incorrect wiring connec-
tions.
3. If the LED still doesn’t flash, replace
the module.
The red BUS
LED blinks but
the system does
not respond
when zones are
tripped.
1. Re-initialize the panel by disconnect-
ing and reconnecting panel power.
2. Make sure the zone has been “learned”
into panel memory.
3. Verify that the panel recognizes the
module by entering program mode
(see specific panel Installation
Instructions).
4. Remove zones and try installing the
module without the zones.
5. Replace the module.
One relay never
activates. 1. Check panel/HOM programming.
2. Check that the point (particular HOM
output) programmed trigger event
actually occurs.
3. Check output-to-output device wiring.
Relay(s) activate
only
momentarily.
OR
Relay(s) activate
randomly.
1. Check panel/programming (particular
HOM output) uses correct response
configuration.
2. Check SuperBus 2000 wire routing
and length.

8SuperBus® 2000 Hardwire Output Module (HOM)
Replacing the HOM Cover
Replacing the HOM Cover
To replace the HOM cover on wall mount
installations:
1. Insert the two tabs at the bottom of the module back
plate into the slots of the cover.
2. Swing the cover up and press onto the back plate until
it clicks into place.
Note
On in-cabinet mounting installations the HOM module
cover is not used and may be discarded.
Specifications
Compatibility: International Concord security
panels.
Power Requirements: 12 VDC, 25 mA typical (idle), plus
39 mA per energized relay(180 mA
maximum with all relays ener-
gized). Power supplied from the
panel through the SuperBus 2000
connections.
Input: One supervised hardwire input zone
Outputs: Four panel programmable, “Form-
C” relay contacts (COMMON, N/C,
N/O). Relay contacts rated 5.0 A at
30 VDC or 70 VAC
Storage Temperature: -30° to 140° F
(-34° to 60° C)
Operating Temperature Range:
32° to 140° F
(0° to 60° C).
Dimensions: 5.25" (133.4mm) L x 4.125"
(104.8mm) W x 1.0" (25.4mm) D
Case: Belgian gray ABS plastic
Notices
This Intruder Alarm System Accessory (Security Grade 2, Environmen-
tal Class II) has been manufactured to comply with the following Euro-
pean directives:
[i] EMC Directive 89/336/EEC amending directive 92/31/EEC & 93/68 EEC as per
EN 50081: 1992
EN 50130-04: 1995
[ii] Low Voltage Directive (Safety) 73/23/EEC as per
IEC 60950: 1999-04
Changes or modifications not expressly approved by Interactive Technologies, Inc.
can void the user's authority to operate the equipment.
©2000, Interactive Technologies, Inc., an Interlogix company. Interlogix is
a trademark of Interlogix, Inc. ITI and SuperBus are registered trademarks
of Interactive Technologies, Inc. Concord is a trademark of Interactive
Technologies, Inc.
One relay stays
activated. 1. Check if the point is programmed for a
3 minute “on” time and if the
triggering event for the point is
repeatedly “resetting” the 3 minute
timer.
2. Relay may have failed or been
overloaded. Reprogram to use a
different (unused) relay or replace
module.
Table 3: Troubleshooting the HOM (Continued)
Problem Solution
T: 651/777-2690
F: 651/779-4890
I
nteractive
T
echnologies,
I
nc.
2266 Second Street North
North Saint Paul, MN, USA 55109-2900
Security
Automation
Fire Protection
Access Control www.ititechnologies.com
1-800-777-1415
This manual suits for next models
1
Table of contents
Other Interlogix I/O System manuals
Popular I/O System manuals by other brands

Rockwell Automation
Rockwell Automation Series C installation instructions

Opal-RT
Opal-RT OP8615 user manual

DOLD
DOLD BG 5914.08 0 Series operating instructions

Siemens
Siemens CASTOMAT ION ANALOGINPUT T001 operating instructions

National Instruments
National Instruments sbRIO-9229 Operating instructions and specifications

KonNad
KonNad C2000-A2-SDD8020-BB3 user manual