IRONRIDGE GROUND MOUNT User manual

GROUND MOUNT
INSTALLATION MANUAL

CONTENTS
GROUND MOUNT INSTALLATION MANUAL - 1©2019 IRONRIDGE, INC. VERSION 2.2
DISCLAIMER 1
RATINGS 2
MARKINGS 2
CHECKLIST 3
1. BUILD BASE 4
2. CONNECT SUBSTRUCTURE 4
3. PLACE RAILS 5
4. SECURE LUGS 5
5. SECURE MODULES 6
CAMO 7
ELECTRICAL DIAGRAM 8
DIAGONAL BRACES (OPTIONAL) 9
END CAPS 9
WIRE CLIPS 9
SPLICING CROSS PIPE 10
MICROINVERTER KITS 11
SYSTEMS USING ENPHASE MICROINVERTERS OR SUNPOWER AC MODULES 11
SYSTEMS USING MICROSTORAGE PRODUCTS 12
FRAMELESS MODULE KITS 12
MODULE COMPATIBILITY 13
MODULE COMPATIBILITY 14
MODULE COMPATIBILITY 15
MODULE COMPATIBILITY 16
DISCLAIMER
This manual describes proper installation procedures and provides necessary standards required for product reliability.
Warranty details are available on website. All installers must thoroughly read this manual and have a clear understanding
of the installation procedures prior to installation. Failure to follow these guidelines may result in property damage, bodily
injury or even death.
IT IS THE INSTALLER’S RESPONSIBILITY TO:
• Ensure safe installation of all electrical aspects of the array. All electrical installation and procedures should be
conducted by a licensed and bonded electrician or solar contractor. Routine maintenance of a module or panel shall
not involve breaking or disturbing the bonding path of the system. All work must comply with national, state and local
installation procedures, product and safety standards.
• Comply with all applicable local or national building and re codes, including any that may supersede this manual.
• Ensure all products are appropriate for the installation, environment, and array under the site’s loading conditions.
• Use only IronRidge parts or parts recommended by IronRidge; substituting parts may void any applicable warranty.
• Review the Design Assistant and Certication Letters to conrm design specications.
• Ensure provided information is accurate. Issues resulting from inaccurate information are the installer’s responsibility.
• Validate foundation parameters prior to installation, as a local geotechnical report may be required to assess ground
conditions. We recommend consulting with a local engineer familiar with local regulations and build site requirements,
including soil conditions, terrain and load criteria. All parameters may impact foundation requirements.
• Ensure bare copper grounding wire does not contact aluminum and zinc-plated steel components, to prevent risk of
galvanic corrosion.
• If loose components or loose fasteners are found during periodic inspection, re-tighten immediately. If corrosion is
found, replace affected components immediately.
• Provide an appropriate method of direct-to-earth grounding according to the latest edition of the National Electrical
Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Photovoltaic Systems.
• Disconnect AC power before servicing or removing modules, AC modules, microinverters and power optimizers.
• Review module manufacturer’s documentation for compatibility and compliance with warranty terms and conditions.

GROUND MOUNT INSTALLATION MANUAL - 2©2019 IRONRIDGE, INC. VERSION 2.2
RATINGS
MARKINGS
Product markings are located on the system’s Rail
Connectors.
UL 2703 LISTED
• Conforms to STD UL 2703 (2015) Standard for Safety First Edition: Mounting Systems, Mounting Devices, Clamping/
Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels.
• Certied to CSA STD LTR AE-001-2012 Photovoltaic Module Racking Systems.
• Max Overcurrent Protective Device (OCPD) Rating: 25A
• Max Module Size: 24ft²
• Max Frameless Module Size for Canadian LTR-AE: 19.5 ft²
• CAMO Specic Allowable Design Load Rating: 50 PSF downward, 50 PSF upward, 15 PSF lateral
• LTR AE Canadian Load Rating: 2400 Pa
• System Level Allowable Design Load Rating: meets minimum requirements of the standard (10 PSF downward, 5
PSF upward, 5 PSF lateral). Actual system structural capacity is dened by PE stamped certication letters.
CLASS A SYSTEM FIRE RATING PER UL 2703
• Not Fire Rated
STRUCTURAL CERTIFICATION
• Designed and Certied for Compliance with the International Building Code & ASCE/SEI-7
#5003225

GROUND MOUNT INSTALLATION MANUAL - 3©2019 IRONRIDGE, INC. VERSION 2.2
CHECKLIST
IRONRIDGE COMPONENTSPRE-INSTALLATION
☐Verify module compatibility. See Page 12for info.
☐Purchase 2” or 3” ASTM A53 Grade B Schedule 40
Pipe, galvanized to a min of ASTM A653 G90 or ASTM
A123 G35, or 2.375” or 3.500” Allied Mechanical
Tubing with Gatorshield or FlowCoat Zinc coating
(ASTM A1057).
TOOLS REQUIRED
☐Post Hole Digger or Powered Auger
☐Socket Drive (7/16”, 9/16”, and 1/2” Sockets)
☐Torque Wrenches (0-240 in-lbs and 10-40 ft-lbs)
☐Transit, String Line, or Laser Level
☐3/16” Allen Head
TORQUE VALUES
☐Top Cap Set Screws (3/16” Allen Head)
☐Schedule 40 Grade B Pipe: 20 ft-lbs
☐2.” Allied Mechanical Tubing: 11 ft-lbs
☐3” Allied Mechanical Tubing: 16 ft-lbs
☐Top Cap U-Bolt Nuts (9/16” Socket): 15 ft-lbs
☐Rail Connector Bracket Nuts (9/16” Socket): 21 ft-lbs
☐Rail Connector U-Bolt Nuts (9/16” Socket): 60 in-lbs
☐Grounding Lug Nuts (7/16” Socket): 80 in-lbs
☐Grounding Lug Terminal Screws (7/16 Socket): 20 in-lbs
☐Universal Fastening Objects (7/16” Socket): 80 in-lbs
☐Diagonal Brace Set Screws (1/2” Socket): 15 ft-lbs
☐Diagonal Brace Bolts (1/2” Socket): 40 ft-lbs
☐Microinverter Kit Nuts (7/16” Socket): 80 in-lbs
☐Frameless Module Kit Nuts (7/16” Socket): 80 in-lbs
ÞIf using previous version of: Integrated Grounding Mid Clamps,
Grounding Lug, End Clamps, and Expansion Joints please refer to
Alternate Components Addendum (Version 1.30).
ÞIf installing on a low slope roof please refer to Ground Mount for
Flat Roof Applications Addendum (Version 1.90).
XR100 & XR1000 Rail Rail Connector
Top Cap UFO
Diagonal Brace
Stopper Sleeve
Grounding Lug Microinverter Kit
Frameless Module Kit Frameless End/Mid Clamp
CAMO
End Cap Wire Clip

GROUND MOUNT INSTALLATION MANUAL - 4©2019 IRONRIDGE, INC. VERSION 2.2
1. BUILD BASE
A. MARK LOCATIONS
Establish pier locations. Once grid of pier locations has
been set, verify all angles are square.
ÞSpacing varies with load conditions. Consult engineering specs.
B. POSITION PIERS
Excavate the foundation holes. Insert vertical piers into
foundation holes, and pour in concrete mixture. Ensure
vertical piers are plumb, level, square, and placed in
parallel rows. Level the tops so they are even.
ÞBrace piers until concrete foundation has cured.
ÞIn some cases, cross bracing is required to provide extra support
for piers. If required, install Diagonal Braces at this time.
A. MOUNT TOP CAPS
Mount a Top Cap on each pier. Wait to tighten set screws.
ÞIf using Diagonal Braces, install them prior to Top Caps.
B. LAY CROSS PIPE
Set cross pipes or tubing in Top Cap grooves. Attach with
3/8” U-bolts, ange nuts, at washers, and lock washers.
Torque U-bolts to 15 ft-lbs and align assembly.
Torque Top Cap set screws to 20 ft-lbs for Schedule 40
Grade B Pipe, 11 ft-lbs for 2” Allied Mechanical Tubing,
and 16 ft-lbs for 3” Allied Mechanical Tubing.
ÞTo join more than one section of cross pipe, see Page 10.
2. CONNECT SUBSTRUCTURE
A
B
A
B
Level Tops Vertical Pier
(Schedule 40 Pipe)
Level Ground
90°
U-Bolt
15 ft-lbs
Set Screws
Schedule 40 Grade B Pipe: 20 ft-lbs
2” Allied Tubing: 11 ft-lbs
3” Allied Tubing: 16 ft-lbs
1/3 Depth
Concrete
Foundation
Depth

GROUND MOUNT INSTALLATION MANUAL - 5©2019 IRONRIDGE, INC. VERSION 2.2
3. PLACE RAILS
A. ATTACH HARDWARE
On the ground, attach Rail Connector brackets to rail by
sliding 3/8”-16 bonding bolts into side slot. Space out to
match pier spacing. With brackets in place, nger tighten
ange nuts onto bolts.
ÞTape ends of rail, to keep bolts from sliding out while moving.
B. FASTEN CONNECTORS
Center rails on cross pipes, leaving equal distance on
ends. Secure with Rail Connector hardware: 3/8”-16
U-bolts, ange nuts, at washers, and lock washers.
Torque U-bolt nuts to 60 in-lbs and bracket to 21 ft-lbs.
ÞSpacing between rails should align with module manufacturer
recommended clamping locations.
GROUNDING LUGS
Insert T-bolt in top rail slot and torque hex nut to 80 in-
lbs. Install a minimum 10 AWG solid copper or stranded
grounding wire. Torque terminal screw to 20 in-lbs.
ÞOnly one Grounding Lug required per continuous subarray,
regardless of subarray size (Unless frameless modules are used,
see Page 10).
ÞIf using Enphase microinverters or Sunpower AC modules,
Grounding Lugs may not be needed. See Page 11 for more info.
ÞGrounding Lugs can be installed anywhere along the rail and in
either orientation shown.
ÞGrounding Lugs are intended to for use with one solid or stranded
copper wire, conductor size 10-4AWG.
4. SECURE LUGS
A
B
U-Bolt
60 in-lbs
Bracket
21 ft-lbs
Hex Nut
(84 in-lbs)
Terminal Screw
(20 in-lbs)
Hex Nut
(80 in-lbs)

GROUND MOUNT INSTALLATION MANUAL - 6©2019 IRONRIDGE, INC. VERSION 2.2
5. SECURE MODULES
A. SECURE FIRST END
Place rst module in position on rails, a minimum of 1”
from rail ends. Snap Stopper Sleeves onto UFO. Fasten
module to rail using the UFO, ensuring that the UFO is
hooked over the top of the module. Torque to 80 in-lbs.
ÞEnsure rails are square before placing modules.
ÞHold Stopper Sleeves on end while torquing to prevent rotation.
ÞIf using CAMO instead of UFO + Stopper Sleeve, refer to Page 7
for CAMO installation procedure.
B. SECURE NEXT MODULES
Place UFO into each rail, placing them ush against rst
module. Slide second module against UFO. Torque to 80
in-lbs. Repeat for each following module.
ÞWhen reinstalling UFO, move modules a minimum of 1/16” so
UFOs are in contact with a new section of module frame.
ÞWhen UFOs are loosened and re-tightened, ensure UFO T-bolt
bottoms out in rail channel before re-torquing UFO to achieve full
engagement between T-bolt and rail.
ÞIf using Wire Clips, refer to Page 9.
C. SECURE LAST END
Place last module in position on rails, a minimum of 1”
from rail ends. Snap Stopper Sleeves onto UFO. Secure
UFO Clamps on rails, ensuring they are hooked over top
of module. Torque to 80 in-lbs.
ÞHold Stopper Sleeves on end while torquing to prevent rotation.
ÞIf using CAMO instead of UFO + Stopper Sleeve, refer to Page 7
for CAMO installation procedure.
D. REPEAT STEPS
Secure remaining module rows, leaving a minimum 3/8”
gap between rows.
ÞIf using End Caps, refer to Page 9.
A
B
C
D
UFO
80 in-lbs
UFO
80 in-lbs
UFO
80 in-lbs

GROUND MOUNT INSTALLATION MANUAL - 7©2019 IRONRIDGE, INC. VERSION 2.2
CAMO
A. SLIDE INTO RAIL
Slide CAMO into rail channel far enough to clear the
module frame. CAMO requires 6" of clearance from end of
rail.
B. PLACE MODULE
Place module on rails (module cells not shown for clarity).
When installing CAMO the module can overhang the rail
no more than 1/4”.
C. PULL TOWARDS END
Pull CAMO towards rail ends, at 45 degree angle, so the
bonding bolt contacts the module ange edge.
D. SECURE TO FRAME
Rotate handle with an upwards motion until CAMO snaps
into rail channel. Ensure CAMO bonding pins are fully
seated on top of module frame.
FRAME COMPATIBILITY
CAMO has been tested or evaluated with all modules
listed in the Module Compatibility section having frames
within the referenced dimensions. Be sure the specic
module being used meets the dimension requirements.
ÞFor installations with Hanwha Q CELLS modules with 32 mm
frame heights, the maximum ground snow is 45 PSF (33 PSF
module pressure).
ÞCAMO is not compatible with Canadian Solar modules.
A
B
C
D
6" Clearance

GROUND MOUNT INSTALLATION MANUAL - 8©2019 IRONRIDGE, INC. VERSION 2.2
ELECTRICAL DIAGRAM
UFO Clamp Grounding Lug
Min 10 AWG
Copper Wire
Fault Current
Ground Path
Bonding Points Fault Current Ground Path
*Grounding Lugs and wire are not required in systems using
certain Enphase microinverters or certain Sunpower modules.
Equipment grounding is achieved with the Engage cable for
Enphase or the AC module cable system for Sunpower via their
integrated EGC.
*
*
Section View
Plan View
Optional Cross Brace
Only one Grounding Lug required per continuous subarray.
*
Cross Pipe
Rail
Cross Pipe
UFO or
CAMO

GROUND MOUNT INSTALLATION MANUAL - 9©2019 IRONRIDGE, INC. VERSION 2.2
DIAGONAL BRACES (OPTIONAL)
Slide sleeve on north pier 2-3” above the ground (6” max).
Attach Diagonal Brace to sleeve with 1/2” hardware.
Slide second sleeve up on south pier 2-3” below top cap
(6” max). Raise Diagonal Brace to align holes in sleeve
and brace. Attach hardware and raise sleeve to full extent.
Torque Diagonal Brace bolts to 40 ft-lbs. Torque set
screws to 15 ft-lbs.
END CAPS
WIRE CLIPS
End Caps add a completed look and keep debris and
pests from collecting inside rail.
Firmly press End Cap onto rail end.
ÞEnd Caps come in sets of left and right. Check that the proper
amount of each has been provided.
ÞFor open-structure installations, you can use adhesive to secure
the End Caps.
Wire Clips offer a simple wire management solution.
Firmly press Wire Clip into top rail slot. Open clip and
insert electrical wire accordingly. Close clip once complete.
South Pier North Pier
Diagonal Brace
Diagonal Brace Bolts
40 ft-lbs
Set Screws
15 ft-lbs
Sleeve
Press Clip
into Slot
Run Wire
Snap Clip
Closed

GROUND MOUNT INSTALLATION MANUAL - 10©2019 IRONRIDGE, INC. VERSION 2.2
SPLICING CROSS PIPE
The following instructions should be followed, when
required, to join more than one section of cross pipe
together to ensure bonding is maintained throughout the
system.
A. ALLIED MECHANICAL TUBING SPLICES
Mechanical tube splices shown in the table below shall be
of equivalent Allied Flowcoat or Gatorshield zinc coating.
Insert splice tube 6” into rst section of cross pipe and se-
cure with 2 self-drilling screws (1/4”-14 x ¾”), spacing them
approximately 1.25” from end of pipe and approximately
3.50” apart, tightening screws to 9 ft-lbs.
Slide second section of cross pipe over splice tube and
secure with two more self-drilling screws. Tighten screws
to 9 ft-lbs.
ÞPre-drill 5/32” pilot holes through cross pipe and splice tube for
easier installation of self-drilling screws.
B. SCHEDULE 40 GRADE B PIPE SPLICES
Use galvanized threaded pipe couplings that match the
pipe size used for the structure. Threaded Schedule 40
Grade B Pipe must be used when splicing cross pipe
together.
Fully thread coupling onto both sections of pipe being
spliced together.
ÞTo ensure structural integrity of cross pipes, mechanical tube or
coupling splices are not permitted in end spans or in middle 1/3 of
interior cross pipe spans.
C. CROSS PIPES CAN BE JOINED OVER AN INTERIOR
TOP CAP WITH A MAXIMUM GAP OF 1/2”
ÞTo avoid potential problems from the effects of thermal
expansion, a maximum total continuous cross pipe length
of 100 ft is recommended.
Mechanical Tube Size
of the Structure Splice Tube Size
2.375” OD, 12 Gauge 2.000” OD, 9 Gauge,
Minimum 12” Long
3.500” OD, 8 Gauge 3.000” OD, 12 Gauge,
Minimum 12” Long
A
B
C

GROUND MOUNT INSTALLATION MANUAL - 11©2019 IRONRIDGE, INC. VERSION 2.2
MICROINVERTER KITS
One Microinverter
Kit Required
(80 in-lbs)
Use IronRidge's Microinverter Kit to bond compatible
microinverters and power optimizers to the racking system.
Insert Microinverter Kit T-bolt into top rail slot. Place
compatible microinverter or power optimizer into position
and tighten hex nut to 80 in-lbs.
ÞIf installing in areas with ground snow loads greater than 40 psf,
install MLPE devices directly next to module frame edge
SYSTEMS USING ENPHASE MICROINVERTERS OR SUNPOWER AC MODULES
IronRidge systems using approved Enphase products or SunPower modules eliminate the need for lay-in lugs and eld
installed equipment grounding conductors (EGC). This solution meets the requirements of UL 2703 for bonding and
grounding and is included in this listing.
COMPATIBLE PRODUCTS
Sunpower
Modules with model identier Ab-xxx-YY and InvisiMount (G5) 46mm frame; where “A” is either E, or X; “b” can be 17, 18, 19, 20, 21, or 22;
and “YY” can be C-AC, D-AC, BLK-C-AC, or BLK-D-AC.
Enphase
Microinverters M250-72, M250-60, M215-60, C250-72, and Engage cables ETXX-240, ETXX-208, ETXX-277.
ÞA minimum of two inverters mounted to the same rail and connected to the same Engage cable are required.
ÞThe microinverters or Sunpower AC modules must be used with a maximum 20 A branch rated overcurrent protection device (OCPD).
ÞIf an AC module is removed from a circuit for maintenance, you must rst disconnect AC power and then install a temporary EGC to
bridge the gap by inserting an AC extension cable (or via other NEC-compliant means), in order to maintain effective ground continuity
to subsequent modules.
On AP systems equipment,
remove Grounding Washer
COMPATIBLE PRODUCTS
Enphase
M250-72, 250-60, M215-60, C250-72, S230, S280, IQ 6, IQ 6+, IQ
IQ7, IQ 7A, IQ 7+, IQ 7X, Q Aggregator
Darfon
MIG240, MIG300, G320, G640
Solar Edge
P300, P320, P340, P370, P400, P405, P485, P505, P600, P700,
P730, P800p, P800s, P850, P860
SMA
RoofCommKit-P2-US, TS4-R Module Retrot Kits (TS4-R-S,
TS4-R-O, TS4-R-F)
Tigo
Tigo Access Point (TAP), TS4-R-X (where X can be O, S, F, or
M), TS4-R-X-DUO (where X can be O, S, or M), TS4-A-F, TS4-
A-2F, TS4-A-O, TS4-A-O-DUO
AP Systems
QS1, YC600
ÞRemove Grounding Washer on AP Systems QS1 and YC600
inverters before installing to XR rails.
ÞRemove the Stainless Steel Clip on Tigo-”A” MLPE Devices
before attaching to XR rails.
ÞUse the number of IronRidge Microinverter kits allowed
by the MLPE mounting ange. Some will require 1 kit and
others 2 kits.
Two Microinverter
Kits Required
(80 in-lbs)

DIAGONAL BRACES (OPTIONAL)
GROUND MOUNT INSTALLATION MANUAL - 12©2019 IRONRIDGE, INC. VERSION 2.2
Use IronRidge's Microinverter Kit to bond compatible microstroage
devices to the racking system. Insert Microinverter Kit T-bolt into top
rail slot. Place compatible microstorage into position and tighten hex
nut to 80 in-lbs.
Microinverter Kit
(80 in-lbs)
SYSTEMS USING MICROSTORAGE PRODUCTS
Insert Frameless Kit T-bolt in top rail slot. Place star
washer over T-bolt, allowing it to rest on top of rail. Secure
module clamps with a hex nut and torque to 80 in-lbs. Place
Star Washer
Module Clamp
(80 in-lbs) Grounding Lugs
Required on Every Rail
FRAMELESS MODULE KITS
COMPATIBLE PRODUCTS
PHAZR
PHAZR Devices PHAZR-X, where X is 6-12.
ÞRunning a separate equipment grounding conductor to the PHAZRs is
not required.
ÞIf installing in areas with ground snow loads greater than 40 psf and
underneath a module, install PHAZR devices as close as possible to
module frame edge.
ÞUse the number of IronRidge Microinverter kits allowed by the
microstorage mounting ange. Some will require 1 kit and others 2 kits.
COMPATIBLE PRODUCTS
Sunforson
Sunforson silver or black SFS-UTMC-200(B) mid and SFS-UTEC-
200(B) end clamps.
Sunpreme
Sunpreme silver or black mid and end clamps with part numbers
7500105X where “X” is 1, 5, 6 or 7.
Ironridge
IronRidge silver or black mid and end clamps with part numbers
FMLS-XC-001-Y where “X” is E or M and “Y” is B or blank.
ÞFollow module manufacturer’s installation instructions to install
the module clamps.
ÞFrameless modules require using a Grounding Lug on every
rail.
ÞFor Sunpreme Modules Only: If required to use slide prevention
hardware, see Module Slide Prevention Addendum (Version
1.10).

GROUND MOUNT INSTALLATION MANUAL - 13©2019 IRONRIDGE, INC. VERSION 2.2
MODULE COMPATIBILITY
The Ground Mount System may be used to ground and/or mount a PV module complying with UL 2703 only when the
specic module has been evaluated for grounding and/or mounting in compliance with the included instructions. Unless
otherwise noted, “xxx” refers to the module power rating and both black and silver frames are included in the certication.
MAKE MODELS
Amerisolar Amerisolar modules with 35, 40 and 50 mm frames AS-bYxxxZ Where "b" can be 5 or 6; "Y" can be M,
P, M27, P27, M30, or P30; "xxx" is the module power rating; and "Z" can be blank, W or WB
Aptos Aptos modules with 35 and 40 mm frames DNA-yy-zz23-xxx Where "yy" can be 120 or 144; "zz" can be
MF or BF; and ""xxx" is the module power rating
Astronergy Solar
Astronergy modules with 30, 35, 40 and 45 mm frames aaSMbbyyC/zz-xxx Where “aa” can be CH or
A; "bb" can be 60, 66, or 72; “yy” can be blank, 10 or 12; "C" can M, P, M(BL), M-HC, M(BL)-HC, P-HC,
M(DG), or M(DGT); “zz” can be blank, HV, F-B, or F-BH ; and “xxx” is the module power rating
Astronergy frameless modules CHSM6610P(DG)-xxx Where “xxx” is the module power rating
ASUN ASUN modules with 35 and 40 mm frames ASUN-xxx-YYZZ-aa Where "xxx" is the module power
rating;" YY" can be 60 or 72; "ZZ" can be M,or MH5; and "aa" can be blank or BB
Auxin Auxin modules with 40 mm frames AXN6y6zAxxx Where "y" can be M or P; "z" can be 08, 09, 10, 11, or
12; "A" can be F or T; and "xxx" is the module power rating
Axitec
Axitec Modules with 35 and 40 mm frames AC-xxxY/aaZZb Where "xxx" is the module power rating; "Y"
can be M, P or MH; "aa" can be blank, 125- or 156-; "ZZ" can be 54, 60, 72, 120, or 144; "b" can be S or
SB
Boviet Boviet modules with 35 and 40mm frames BVM66aaYY-xxxBB Where "aa" can be 9, 10 or 12; "YY" is M
or P; "xxx" is the module power rating; and "BB" can be blank or L
BYD BYD modules with 35 mm frames BYDxxxAY-ZZ Where "xxx" is the module power rating; "A" can be
M6, P6, MH or PH; "Y" can be C or K; and "ZZ" can be 30 or 36
Canadian Solar
Canadian Solar modules with 30, 35 and 40 mm frames CSbY-xxxZ Where "b" can be 1, 3 or 6; "Y" can
be H, K, P, U, V, W, or X; "xxx" refers to the module power rating; and "Z" can be M, P, MS, PX , M-SD,
P-AG, P-SD, MB-AG, PB-AG, MS-AG, or MS-SD
Canadian Solar frameless modules CSbY-xxx-Z Where "b" can be 3 or 6; "Y" is K, P, U, or X; "xxx" is the
module power rating, and "Z" can be M-FG, MS-FG, P-FG, MB-FG, or PB-FG
CertainTeed CertainTeed modules with 35 and 40 frames CTxxxYZZ-AA Where "xxx" is the module power rating; "Y"
can be M, P or HC; "ZZ" can be 00,01, 10, or 11; and "AA" can be 01, 02, 03 or 04
CSUN Csun modules with 35 and 40 mm frames YYxxx-zzAbb Where "YY" is CSUN or SST; xxx is the module
power rating; "zz" is blank, 60, or 72; and "A" is blank, P or M; "bb" is blank, BB, BW, or ROOF
Ecosolargy
Ecosolargy modules with 35, 40 and 50 mm frames ECOxxxYzzA-bbD Where "xxx" is the module power
rating; "Y" can be A, H, S, or T; "zz" can be 125 or 156; "A" can be M or P; "bb" can be 60 or 72; and "D"
can be blank or B

GROUND MOUNT INSTALLATION MANUAL - 14©2019 IRONRIDGE, INC. VERSION 2.2
MODULE COMPATIBILITY
ET Solar
ET Solar modules with 35, 40 and 50 mm frames ET-Y6ZZxxxAA Where “Y” can be P, L, or M; “ZZ”
can be 60 or 72; “xxx” refers to the module power rating; and “AA” can be WB, WW, BB, WBG, WWG,
WBAC, WBCO, WWCO, WWBCO or BBAC
Flex
Flex modules with 35, 40 and 50 mm frames and model identier FXS-xxxYY-ZZ; where "xxx" is the
module power rating; "YY" can be BB or BC; and "ZZ" can be MAA1B, MAA1W, MAB1W, SAA1B,
SAA1W, SAC1B, SAC1W, SAD1W, SBA1B, SBA1W, SBC1B, or SBC1W
GCL GCL modules with 35 mm and 40 mm frames GCL-ab/YY xxx Where "a" can be M or P; "b" can be 3 or
6; "YY" can be 60, 72, 72H, or 72DH; and xxx is the module power rating
GigaWatt Solar Gigawatt modules with 40 mm frames GWxxxYY Where “xxx” refers to the module power rating; and
“YY” can be either PB or MB
Hansol Hansol modules with 35 and 40 frames HSxxxYY-zz Where "xxx" is the module power rating; "YY" can
be PB, PD, PE, TB, TD, UB, UD, or UE; and "zz" can be AH2, AN1, AN3, AN4, HV1, or JH2
Hanwha Solar Hanwha Solar modules with 40, 45, and 50 mm frames HSLaaP6-YY-1-xxxZ Where "aa" can be either
60 or 72; "YY" can be PA or PB; "xxx" refers to the module power rating; and "Z" can be blank or B
Hanwha Q CELLS
Hanwha Q CELLS Modules with 32, 35, 40, and 42mm frames and model identier aaYY-ZZ-xxx
where "aa" can be Q. or B.; "YY" can be PLUS, PRO, PEAK, LINE PRO, LINE PLUS, PLUS DUO or
PEAK DUO; and "ZZ" can be G3, G3.1, G4, G4.1, L-G2, L-G2.3, L-G3, L-G3.1, L-G3y, L-G4, L-G4.2,
L-G4y, LG4.2/TAA, BFR-G3, BLK-G3, BFR-G3.1, BLK-G3.1, BFR-G4, BFR-G4.1, BFR G4.3, BLK-G4.1,
G4/SC, G4.1/SC, G4.1/TAA, G4.1/MAX, BFR G4.1/TAA, BFR G4.1/MAX, BLK G4.1/TAA, BLK G4.1/
SC, EC-G4.4, G5, BLK-G5, L-G5, L-G5.1, L-G5.2, L-G5.2/H, L-G5.3, G6, G6+, BLK-G6, L-G6, L-G6.1,
L-G6.2, L-G6.3, G7, BLK-G6+, BLK-G7, G7.2, G8, BLK-G8, G8+, BLK-G8+ L-G7, L-G7.1, L-G7.2,
L-G7.3, L-G8, L-G8.1, L-G8.2, or L-G8.3; and "xxx" is the module power rating
Heliene Heliene modules with 40 mm frames YYZZxxxA Where "YY" can be 36, 60, 72, or 96; "ZZ" can be M, P,
or MBLK; "xxx" is the module power rating; and "A" can be blank, HomePV, or Bifacial
HT-SAAE HT-SAAE modules with 40 mm frames HT72-156Z-xxx Where "Z" can be M, P, M-C, P-C, M(S), M(VS),
M(V), P(V), M(V)-C, P(V)-C; and "xxx" is the module power rating
Hyundai
Hyundai modules with 33, 35, 40 and 50 mm frames HiY-SxxxZZ Where "Y" can be A, D, M or S; "xxx"
refers to the module power rating; and "ZZ" can be HG, HI, KI, MI, MF, MG, RI, RG, RG(BF), RG(BK),
SG, TI, or TG
Itek Itek Modules with 40 and 50 mm frames IT-xxx-YY Where "xxx" is the module power rating; and "YY"
can be blank, HE, or SE, or SE72
JA Solar
JA Solar modules with 30, 35, 40 and 45 mm frames JAyyzz-bbww-xxx/aa Where “yy” can be M, P, M6
or P6; “zz” can be blank, (K), (L), (R), (V), (BK), (FA), (TG), (FA)(R), (L)(BK), (L)(TG), (R)(BK), (R)(TG),
(V)(BK), (BK)(TG), or (L)(BK)(TG); “bb” can be 48, 60, or 72; "ww" can be D09, S01, S02, S03, S06,
S09, or S10; “xxx” is the module power rating; and “aa” can be BP, MP, SI, SC, PR, 3BB, 4BB, 4BB/RE,
5BB
Jinko
Jinko modules with 35 and 40 mm frames JKMYxxxZZ-aa Where "Y" can either be blank or S; "xxx"
is the module power rating; "ZZ" can be M, P, or PP; and "aa" can be blank, 60, 60B, 60H, 60L, 60BL,
60HL, 60HBL, 60-J4, 60B-J4, 60B-EP, 60(Plus), 60-V, 60-MX, 72, 72-V, 72H-V, 72L-V, 72HL-V, 72-MX,
72H-BDVP, or 72HL-TV Jinko frameless modules JKMxxxPP-DV Where "xxx" is the module power
rating
Kyocera
Kyocera Modules with 46mm frames KYxxxZZ-AA Where "Y" can be D or U; "xxx" is the module power
rating; "ZZ" can be blank, GX, or SX; and "AA" can be LPU, LFU, UPU, LPS, LPB, LFB, LFBS, LFB2,
LPB2, 3AC, 3BC, 3FC, 4AC, 4BC, 4FC, 4UC, 5AC, 5BC, 5FC, 5UC, 6BC, 6FC, 8BC, 6MCA, or 6MPA
LG
LG modules with 35, 40, and 46 mm frames LGxxxYaZ-bb Where "xxx" is the module power rating; "Y"
can be A, E, N, Q, S; "a" can be 1 or 2; "Z" can be C, K, T, or W; and "bb" can be A3, A5, B3, G3, G4, J5,
K4, or V5
Longi
Longi modules with 30, 35 and 40 mm frames LRa-YYZZ-xxxM Where "a" can be 4 or 6; "YY" can be
blank, 60 or 72; "ZZ" can be blank, BK, BP, HV, PB, PE, PH, HBD, HPB, or HPH; "xxx" is the module
power rating

GROUND MOUNT INSTALLATION MANUAL - 15©2019 IRONRIDGE, INC. VERSION 2.2
MODULE COMPATIBILITY
Mission Solar
Mission Solar modules with 33 and 40 mm frames MSEbbxxxZZaa Where “bb” can be blank or
60A; “xxx” is the module power rating; “ZZ” can be blank, MM, SE, SO, SQ , SR, or TS; and “aa”
can be blank, 1J, 4J, 4S, 5K, 5T, 60, 6J, 6S, 6W, 8K, 8T, or 9S
Mitsubishi Mitsubishi modules with 46 mm frames PV-MYYxxxZZ Where "YY" can be LE or JE; xxx is the
module power rating; and "ZZ" can be either HD, HD2, or FB
Motech IM and XS series modules with 40, 45 and 50 mm frames
Neo Solar Power
Neo Solar Power modules with 35 mm frames D6YxxxZZaa Where "Y" can be M or P; xxx is the
module power rating; "ZZ" can be B3A, B4A, E3A, E4A, H3A, H4A; and "aa" can be blank, (TF),
ME or ME (TF)
Panasonic
Panasonic modules with 35 and 40 mm frames VBHNxxxYYzzA Where "xxx" refers to the module
power rating; "YY" can be either KA, RA, SA or ZA; "zz" can be either 01, 02, 03, 04, 06, 06B, 11,
11B, 15, 15B, 16, 16B, 17, or 18; and "A" can be blank, E, G, or N
Peimar Peimar modules with 40 mm frames SbxxxYzz Where "b" can be G or P; “xxx” is the module power
rating; “Y” can be M or P; and “zz” can be blank, (BF), or (FB)
Phono Solar
Phono Solar modules with 35, 40, and 45 mm frames PSxxxY-ZZ/A Where xxx refers to the module
power rating; "Y" can be M, M1, MH, or M1H or P; "ZZ" can be 20 or 24; and "A" can be F, T, U, or
TH
Prism Solar Prism Solar frameless modules BiYY-xxxBSTC Where "YY" can be 48, 60, 60S, 72 or 72S; and
"xxx" is the module power rating
REC Solar
REC modules with 30, 38 and 45 mm frames RECxxxYYZZ Where “xxx” is the module power
rating; “YY” can be AA, M, NP, PE, PE72, TP, TP2, TP2M, TP2SM, or TP2S; and “ZZ” can be blank,
Black, BLK, BLK2, SLV, or 72
Renesola
ReneSola modules with 35, 40 and 50 mm frames AAxxxY-ZZ Where "AA" can be SPM(SLP) or
JC; "xxx" refers to the module power rating; "Y" can be blank, F, M or S; and "ZZ" can be blank, Ab,
Ab-b, Abh, Abh-b, Abv, Abv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv-b, Db, Db-b, or 24/Bb
Renogy Renogy Modules with 40 and 50 mm frames RNG-xxxY Where "xxx" is the module power rating;
and "Y" can be D or P
Risen
Risen Modules with 35 and 40 mm frames RSMyy-6-xxxZZ Where "yy" can be 60, 72, 120 or 144;
"xxx" is the module power rating; and "ZZ" can be M or P
Frameless modules RSMyy-6-xxxZZ Where "yy" can be 60, 72, 120 or 144; "xxx" is the module
power rating; and "ZZ" can be MDG or PDG
S-Energy S-Energy modules with 40 frames SNxxxY-ZZ Where "xxx" is the module power rating; "Y" can be
M or P; and "ZZ" can be 10, or 15
Seraphim Energy Group
Seraphim modules with 35 and 40 mm frames SEG-aYY-xxxZZ Where "a" can be blank, 6 or B;
"YY" can be blank, MA, MB, PA, or PB; "xxx" is the module power rating; and "ZZ" can be blank,
BB, BG, BW, HV, WB, WW, BMB, BMB-HV
Seraphim USA Seraphim modules with 40 and 50 mm frames SRP-xxx-6YY Where "xxx" is the module power
rating; and "YY" can be MA, MB, PA, PB, QA-XX-XX, and QB-XX-XX
Sharp Sharp modules with 35 and 40 mm frames NUYYxxx Where “YY” can be SA or SC; and "xxx" is the
module power rating
Silfab Silfab Modules with 38 mm frames SYY-Z-xxxaa Where "YY" can be IL, SA, LA, SG or LG; "Z" can
be blank, M, P, or X; "xxx" is the module power rating; and "aa" can be blank, BL, or NT
Solaria Solaria modules with 40 mm frames PowerXT xxxY-ZZ Where "xxx" is the module power rating; "Y"
can be R or C; and "ZZ" can be AC, BD, BX, BY, PD, PX, PZ, WX or WZ
Solarcity Solarcity modules with 40 mm frames SCxxxYY Where "xxx" is the module power rating; and "YY"
can be blank, B1 or B2
SolarTech SolarTech modules with 42 mm frames STU-xxxYY Where "xxx" is the module power rating; and
"YY" can be PERC or HJT

MODULE COMPATIBILITY
GROUND MOUNT INSTALLATION MANUAL - 16©2019 IRONRIDGE, INC. VERSION 2.2
SolarWorld AG /
Industries GmbH
SolarWorld Sunmodule Plus, Protect, Bisun, XL, Bisun XL, may be followed by mono, poly, duo,
black, bk, or clear; modules with 31, 33 or 46 mm frames SW-xxx Where "xxx" is the module power
rating
SolarWorld Americas Inc. SolarWorld Sunmodule Plus, Protect, Bisun, XL, Bisun XL, may be followed by mono, poly, duo,
black, bk, or clear; modules with 33 mm frames SWA-xxx Where "xxx" is the module power rating
Stion Stion Thin lm modules with 35 mm frames STO-xxx or STO-xxxA Thin lm frameless modules
STL-xxx or STL-xxxA Where "xxx" is the module power rating
SunEdison
SunEdison Modules with 35, 40 and 50 mm frames SE-YxxxZABCDE Where "Y" can be B, F, H, P,
R, or Z; "xxx" refers to the module power rating; "Z" can be 0 or 4; "A" can be B,C,D,E,H,I,J,K,L,M,
or N ; "B" can be B or W; "C" can be A or C; "D" can be 3, 7, 8, or 9; and "E" can be 0, 1 or 2
Suniva
Suniva modules with 35, 38, 40, 46 and 50 mm frames OPTxxx-AA-B-YYY-Z MVXxxx-AA-B-YYY-Z
Where "xxx" is the module power rating; "AA" is either 60 or 72; "B" is either 4 or 5; "YYY" is either
100,101,700,1B0, or 1B1; and "Z" is blank or B
Sunpower
Sunpower standard (G3 or G4) or InvisiMount (G5) 40 and 46 mm frames SPR-Zb-xxx-YY Where
"Z" is either A, E, P or X; “b” can be blank, 17, 18, 19, 20, 21, or 22; “xxx” is the module power
rating and “YY” can be blank, BLK, COM, C-AC, D-AC, E-AC, G-AC, BLK-C-AC, or BLK-D-AC
Sunpreme Sunpreme frameless modules GXB-xxxYY Where "xxx" is the module power rating; and "YY" can
be blank or SL
Sunspark Sunspark modules with 40 mm frames SYY-xxxZ Where “YY” can be MX or ST; “xxx” is the module
power rating; and “Z” can be M, P or W
Suntech Vd, Vem, Wdb, Wde, and Wd series modules with 35, 40 and 50 mm frames
Talesun Talesun modules with 35 and 40 frames TP6yyZxxx-A Where "yy" can be 60, 72, H60 or H72; "Z"
can be M, or P; "xxx" is the module power rating; and "A" can be blank, B, or T
Trina
Trina Modules with 30, 35, 40 and 46mm frames TSM-xxxYYZZ Where "xxx" is the module power
rating; "YY" can be DD05, DD06, DD14, DE14, DE15, DEG15, PA05, PC05, PD05, PD06, PA14,
PC14, PD14, PE14, or PE15 ; and "ZZ" can be blank, .05, .08, .10, .18, .08D, .18D, 0.82, .002,
.00S, 05S, 08S, A, A.05, A.08, A.10, A.18, A(II), A.05(II), A.08(II), A.082(II), A.10(II), A.18(II), H, H(II),
H.05(II), H.08(II), HC.20(II), HC.20(II), or M
Frameless modules TSM-xxxYY Where "YY" can be either DEG5(II), DEG5.07(II), DEG5.40(II),
DEG5.47(II), DEG14(II), DEG14C(II), DEG14C.07(II), DEG14.40(II), PEG5, PEG5.07, PEG5.40,
PEG5.47, PEG14, or PEG14.40
URE URE modules with 35 mm frames DyZxxxHaa Where "y" can be 6 or 7; "Z" can be K or M; "xxx" is
the module power rating; and "aa" can be H3A, H4A, or H8A
Vikram
Vikram solar modules with 40 mm frames VSyy.ZZ.AAA.bb Where "yy" can be M, P, MBB, MH, MS,
MHBB, or PBB; "ZZ" can be 60 or 72; "AAA" is the module power rating; and "bb" can be 03.04 or
05
VSUN
VVSUN modules with 35 and 40 mm frames VSUNxxx-YYz-aa Where "xxx" is the module power
rating; "YY" can be 60, 72, or 144; "z" can be M, P, MH, PH, or BMH; and "aa" can be blank, BB, or
DG
Winaico Winaico modules with 35 and 40 mm frames Wsy-xxxZa Where "y" can be either P or T; "xxx" is the