J.ASSY VISUM Monitor User manual

OPERATOR’SOPERATOR’S
MANUALMANUAL
version 4.2
100 Yellow | 25 Magenta 100 Black
100 Yellow | 25 Magenta 100 Black

Manual
v. 4.2
Product
v. 3.1
Visum Monitor Software
v. 4.4 - 5.0
Manual
v. 4.2
Product
v. 4.0
Visum Fertilizer Software
-----
VISUM MONITOR | VISUM FERTILIZER
This device contains FCC ID 2AD66-RF2401F20
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired operation.
For further information, please visit www.fcc.gov.
This device contains IC ID 21278- RF2401F20
IC compliance
This device complies with Industry Canada license-exempt
RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including
interference that may cause undesired operation
of the device.
Conformité aux normes d’IC
Cet appareil est conforme à la(aux) norme(s) RSS sans
licence d’Industry Canada.
Son utilisation est soumise aux deux conditions suivantes:
(1) Cet appareil ne doit pas causer d’interférences et
(2) Il doit accepter toutes interférences reçues, y compris
celles susceptibles d’avoir des effets indésirables
sur son fonctionnement.

Table of Contents
100 Yellow | 25 Magenta 100 Black
100 Yellow | 25 Magenta 100 Black
Specications .......................................................... 04
Visum Monitor ........................................................ 04
Visum Fertilizer....................................................... 04
Installation................................................................ 05
Visum Monitor ........................................................ 05
Visum Fertilizer....................................................... 06
Recommendations ................................................. 07
Power Connection................................................... 08
Connecting to a power plug inside of
the tractor cab........................................................ 08
Connecting to the tractor battery........................... 08
Attach the antenna................................................. 09
Network ID ............................................................... 10
Operation ................................................................. 12
Functions description ............................................. 14
Version 5.0 or below............................................... 14
F1 | List sensors ..................................................... 14
F2 | Beep volume ................................................... 15
F3 | Brightness ....................................................... 15
F4 | Check Address................................................ 15
F5 | Add sensors .................................................... 16
F6 | Show Monitor ID.............................................. 16
F7 | Maneuver beep delay...................................... 17
Troubleshooting table ............................................. 18
Cleaning and Storage.............................................. 20
Warranty ................................................................... 20
Discarding ................................................................ 21

| J.Assy
4
Operation Instructions
Specifications
Radiofrequency communication at 2.4GHz.
GFSK Modulation.
Omni-directional antenna, 5dBi, 50 Ohms.
SMA connector.
Supply voltage: 10Vdc to 30Vdc.
Display with 2 character, 7 segments.
2 Red/Green/Orange LEDs.
Resistant to dust and water splash.
100 Yellow | 25 Magenta 100 Black
Specifications
Resistant to dust and water jet.
Radiofrequency communication at 2.4GHz.
GFSK Modulation.
Internal antenna.
Dimension: 71mm (A) x 89mm (L).
Weight: 245g.
Internal diameter of the sensor: 45mm.
Wearing protection: Stainless Steel.
Outer diameter of the hose:
from 1 1⁄4 to 2 1⁄16”.
100 Yellow | 25 Magenta 100 Black

OPERATOR´S MANUAL | Visum Monitor | Visum Fertilizer | 5
ATTENTION:
• The Monitor should be installed with the
antenna in a vertical line, and should be avoid
putting the antenna in the horizontal position.
• The Monitor should be installed with the best
possible line of sight to the sensors in order to
avoid communication problems.
• Avoid installing the monitor close to the cab
ROPS column. Keep a minimum distance of
12 in. between monitor and column.
Installation | Visum Monitor
1. Disassemble the bracket of the Monitor, removing the two
side nuts.
2. Clean the installation surface with a cloth and alcohol.
3. Remove the lm from the double-sided tape and fasten the
bracket to the surface by pressing the whole area of the tape.
4. Wait for 15 minutes and then mount the Monitor on the
bracket with the two side nuts.
5. If you install the bracket over a glass surface, put the anti-
UV tape on the opposite side of the glass in order to protect
the double-sided tape from the sun.
6. Press the button to turn on the Monitor and hold it for
5 seconds to turn it off.
Alternatively, the tape may be removed to mount the bracket
with screws or attached to a bar with clamps or RAM Mount
kit (not included).

| J.Assy
6
The sensor is installed between the diffuser/air release and the
fertilizer outlet hose:
Installation | Visum Fertilizer
4
”
2
”
4
”
3
”
16
2
4”2”4”3”162
Choose the correct inlet and outlet coupler
for the hose and diffuser diameters.
ASSEMBLY
1. Cut a piece of the hose at the diffuser side with the
length of the sensor-coupler assembly, so that the
total length will be the same as the original hose.
2. Place the sensor with the
internal antena facing “up”
or “skyward”. The internal
antenna is located to the left
of the square patch with “P”
and “L” between the “J” and
“A” of the word J. Assy. See
illustration below.
TIP:
• Do not bend the couplers to install
in your system. That can increase
clogging or release during use.
TIP:
• Do not install the sensor
at. This will cause sensor
wake up issues.

OPERATOR´S MANUAL | Visum Monitor | Visum Fertilizer | 7
1. Diffuser, 2. Inlet coupler, 3. Outlet coupler, 4. Metal clamps, 5. Hose.
Sensor Assembly
3. Securely fasten the rubber couplers with the metal clamps1.
Do not “overtighten”. Check the hose clamps after
10 minutes of eld operation to ensure everything is snug
and maintaining good connections.
TIP:
• Do not point or align the sensor antenna
toward a metal barrier, that could degrade
the communication efciency from the sensor
to the monitor.
4”2”4”3”162
1 2 3 4 5
Recommendations
11, 75 em - 2, 75 em x 0312 em x 0021 in.
ATTENTION:
• Do not install the sensor upside down.
Installation must match the orientation in the
pictures below.
Flow DirectionFlow Direction

| J.Assy
8
CONNECTING TO THE TRACTOR BATTERY
• Use the included installation kit is detailed below.
2a 2b
2c 2d
1a. The installation kit will
not be used, but a proper
manufacturer harness (not
included) will be needed.
1b. Cut the power cable
excess and mend the wires
with the manufacturer
harness.
CONNECTING TO A POWER PLUG INSIDE OF THE
TRACTOR CAB
The power cable must be connected to 12Vdc to 24Vdc
power source.
Power Connection

OPERATOR´S MANUAL | Visum Monitor | Visum Fertilizer | 9
ATTENTION:
• Do not disconnect any others cables attached
to the battery of the tractor. It may affect the
functionality of other electronics in the tractor.
• The red connector must be protected with self-fusing tape.
• Preferably, the power cable should be connected directly
to the battery terminals.
ATTACH THE ANTENNA
• You will nd the antenna inside your
Monitors box.
• Attach it to the back of the Monitor
by threading on the connection.
Do not “over-tighten”.
• Position the antenna so that it is in
a vertical orientation.

| J.Assy
10
Network ID
All sensors must be congured with the network ID in
order to communicate with the Monitor. The network ID
can be found in the back of the Monitor or can be extract
by software operation. The sensor conguration can be
done with a Visum Monitor. Check how it can be done on
this manual.
The following steps must be done:
1. Find the address indicator on the rubber cover
(square with “P” and “L” and numbers).
2. Wake up the sensor by shaking it.
3. Place the magnet on the address indicator
(make circular movement to easily turn on the
internal switch).
4. Wait for the conrmation beep or message.
5. Fill the address indicator with the number of
the implement and row.
ATTENTION:
• Never congure two sensors at the same
time, even with two different devices, because
the connections may cross each other.
TIP:
1. In order to change the address of any
sensor, just follow the steps again.
2. Before doing the sensor “addressing
procedure”, watch videos on Youtube by
J.Assy (video Visum Monitor).
3. When installing the sensors on your machine
initially, we recommend you “address” the
sensors to the monitor on your
workbench rst before installing the
sensors on the toolbar row units.
Other manuals for VISUM Monitor