logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. jablotron
  6. •
  7. I/O System
  8. •
  9. jablotron JA-110N User manual

jablotron JA-110N User manual

Other jablotron I/O System manuals

jablotron JA-110N-DIN User manual

jablotron

jablotron JA-110N-DIN User manual

jablotron JB-110N User manual

jablotron

jablotron JB-110N User manual

jablotron JA-68 User manual

jablotron

jablotron JA-68 User manual

Popular I/O System manuals by other brands

WAGO 750-344 manual

WAGO

WAGO 750-344 manual

Teknim TWM-1887 Installation & user manual

Teknim

Teknim TWM-1887 Installation & user manual

Intelligent Appliance IA-2662-E user manual

Intelligent Appliance

Intelligent Appliance IA-2662-E user manual

BERGHOF ECC DIO 16/16 User handbook

BERGHOF

BERGHOF ECC DIO 16/16 User handbook

Advantech PCM-27J3AU Startup manual

Advantech

Advantech PCM-27J3AU Startup manual

Festo CP-E08-M12-CL manual

Festo

Festo CP-E08-M12-CL manual

Measurement Computing PCI-DAS64/M1/16 user guide

Measurement Computing

Measurement Computing PCI-DAS64/M1/16 user guide

Hitachi HX-RIO3 Series user manual

Hitachi

Hitachi HX-RIO3 Series user manual

NUUO SCB-A08 user manual

NUUO

NUUO SCB-A08 user manual

M-system R3Y-RS8 instruction manual

M-system

M-system R3Y-RS8 instruction manual

Omron SYSMAC C200H Operation guide

Omron

Omron SYSMAC C200H Operation guide

DOLD SAFEMASTER M Safety Technique

DOLD

DOLD SAFEMASTER M Safety Technique

ABB OPT-MF-001 user manual

ABB

ABB OPT-MF-001 user manual

Omron SYSMAC C2000H Operation guide

Omron

Omron SYSMAC C2000H Operation guide

Helmholz TB20 manual

Helmholz

Helmholz TB20 manual

ICP DAS USA tM-AD2 quick start

ICP DAS USA

ICP DAS USA tM-AD2 quick start

Automationdirect.com DL305 manual

Automationdirect.com

Automationdirect.com DL305 manual

WAGO I/O SYSTEM 750 750-833 manual

WAGO

WAGO I/O SYSTEM 750 750-833 manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

JABLOTRON ALARMS a.s.
Pod Skalkou 4567/33 46601 Jablonec n. Nisou
Czech Republic www.jablotron.com
||
|
JA-110N Bus power output module PG
The JA-110N is a component of the JABLOTRON 100 system.
It provides an output power relay switch. It can be used for
switching on/off the lights, ventilators, etc. The relay can be
controlled with a programmable control panel (PG) output or
according to the status of a section (armed = relay on) or when
there is an alarm in a chosen section (alarm = relay on). The device
should be installed by a trained technician with a valid certificate
issued by an authorized distributor.
Installation
The module shall be installed into the JA-190PL mounting box.
figure: 1 – digital bus terminals; 2 – red relay switching indicator;
3 – configuration switch; 4 – output relay; 5 – relay terminals
1. Use the switch (3) to set the required number of the PG output or
the number of the section to which the relay should react (see
tables).
2. Connect bus wires to the terminals (1).
When connecting the module to the
system digital bus, always switch the
power off.
If the module is installed outside the
protected area, the JA-110T bus insulator
should be used for the external section of
the wiring.
Electrical devices can only be
connected by an authorized
technician.
3. Switch on the system and test its functioning.
4. Check the supply voltage at the bus terminals (red, black) when
the relay is activated. The voltage must be at least 9V.
5. Connect the controlled device to the relay output terminals (5).
Notes:
- The module does not occupy any position in the control panel
(it is not enrolled into the system).
- If you connect multiple modules with identical settings to the bus,
the relays will have the same function.
- The number of modules is only limited by the power consumption
from the digital bus.
- The setting of individual programmable outputs is done in the PG
outputs window in the F-Link program. A detailed description of
the setting is available in the control panel installation manual.
- When the output is set according to the SECTION SET table the
relay is on if the section is fully armed.
- When the output is set according to the SECTION ALARM table
the relay is on if there is external or internal warning (EW or IW).
Table 1: The relay reacts to the PG output state
Table 2: The relay reacts to arming
the choosen section
Table 2: The relay reacts to an
alarm in the choosen section
Technical specifications
Power from control panel digital bus 12 V (9…15 V)
Current consumption in standby mode (relay off / on) 5 mA / 45 mA
Current consumption for cable choice 45 mA
Relay contact rating
Maximum voltage 250 V AC / DC
ReVLVWLYHORDGFRVij  max. 16 A / 250 V AC
IQGXFWLYHFDSDFLWLYHORDGFRVij  max. 8 A / 250 V AC
Minimum acceptable relay output through-wattage(DC) 0.5 W
Protection Class II
Dimensions 78 x 40 x 20 mm
Classification Grade II
according to EN 50131-1, EN 50131-3
Operational environment according to EN 50131-1 II. Indoor general
Operating temperature range -10 °C to 40 °C
Also complies with EN 50130-4, EN 55022, EN 60950-1
JABLOTRON ALARMS a.s. hereby declares that the JA-110N
module is in compliance with the essential requirements and other
relevant provisions of Directive 2004/108/(EC and 2006/95/EC.
The original of the conformity assessment can be found at
www.jablotron.com - Technical Support section
Note: Although this product does not contain any harmful
materials we suggest you return the product to the dealer or
directly to the producer after use. For more detailed information
visit www.jablotron.com.
JA-110N Bus power output module PG 1 / 1 MLY51306