• Make sure the keypad is unlocked and press the DOWN
key for 4s.
• Scroll through the menu labels with the UP and DOWN
keys.
• CH label: displaying compressor operating
hours.
• rCH label: compressor operating hours reset.
• nS1 label: compressor star-up time.
• To access the label press SET.
•In order to reset the compressor operating hours once
selected the rCH label, insert the password “149” using
the UP and DOWN keys then conrm touching the SET
key.
•Touch the ON/STANDBY key to exit the procedure.
General Operations
2
Evco Operating Manual
Keypad Unlocking
Compressor Opperational Time
Date and Time
Buzzer
Cabinet Light
• If the parameter Loc=1 (default) after 30s* without
any keys of the display has been pressed, the display
will show the label “Loc” and the keypad will lock
automatically.
• To unlock the keypad, touch the SET key for 1s. Then
the display will show the label “UnL”.
• If the parameter is u1=0
• Touch the ON/STAND-BY key.
• Ensure the keypad is unlocked then press the DOWN
key for 4s.
• Scroll through the menu’s labels UP or DOWN key up to
the “rtc” label then press the SET key.
• The moniter will display “yy” followed by the two last
digits of the year.
• Set the yeat using the UP or DOWN key then press the
SET key to conrm.
• Repeat the operation for the following labels:
• n: month (01 to 12)
• d: day (01 to 31)
• h: time (00 to 23)
• n: minutes (00 to 59)
• If the parameters u1=3 and u4=1 touch any key to shut
down the buzzer alarm.
Displaying Temperature Probes
Manual Defrost
• First, check the keypad is not locked (and in case unlock
it) and the overcooling cycle is not activated.
• Press the UP key, holding it for 2s.
• If the parameter P3=1 and the evaporator temperature
value is lower than the parameter d2, defrost cycle will
start.
• Ensure the keypad is unlocked then press the DOWN
key for 4 sec.
• Scroll through the menu’s labels by the UP or DOWN
key.
•Pb1: cabinet temperature probe
(if parameter P4=0,1 or 2); inlet air
temperature probe (if parameter P4=3).
•Pb2: Evaporator temperature probe (if
parameter P3=1 or 2)
•Pb3: Auxiliary temperature probe
(If P4=1, 2 or 3).
• To access the label press SET.
• Touch the ON/STANDBY key to exit the procedure.
Temperature Settings
• If the keypad is locked, rst unlock it.
• Touch the SET key then set the desired temperature by
pressing the UP or DOWN keys within 15s according with
the limits range of the set point (parameters r1 and r2)
• Press SET to conrm.
*s=seconds