manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Keeler
  6. •
  7. Adapter
  8. •
  9. Keeler 2508-P-8026 User manual

Keeler 2508-P-8026 User manual

Popular Adapter manuals by other brands

Mini Gadgets BB2Outlet user manual

Mini Gadgets

Mini Gadgets BB2Outlet user manual

LSI LSISAS3442E-R Quick installation guide

LSI

LSI LSISAS3442E-R Quick installation guide

Moeller BBA -16 Series installation instructions

Moeller

Moeller BBA -16 Series installation instructions

Acer MWA3 quick start guide

Acer

Acer MWA3 quick start guide

Connect Tech ADG095 user guide

Connect Tech

Connect Tech ADG095 user guide

cable matters 604002 user manual

cable matters

cable matters 604002 user manual

Solwise PL-85PEW Easy start

Solwise

Solwise PL-85PEW Easy start

HP Photosmart 7100 user guide

HP

HP Photosmart 7100 user guide

HP E2494A installation guide

HP

HP E2494A installation guide

StarTech.com USB150WN1X1 quick start guide

StarTech.com

StarTech.com USB150WN1X1 quick start guide

Lindy 43198 user manual

Lindy

Lindy 43198 user manual

A&D AD-8527 instruction manual

A&D

A&D AD-8527 instruction manual

Motorola WU830G user guide

Motorola

Motorola WU830G user guide

Hawking HUF2 Specifications

Hawking

Hawking HUF2 Specifications

Allen-Bradley E3 Plus installation instructions

Allen-Bradley

Allen-Bradley E3 Plus installation instructions

Trust BT-2210Tp manual

Trust

Trust BT-2210Tp manual

HP NC7170 overview

HP

HP NC7170 overview

Uconnect BLE-485C user manual

Uconnect

Uconnect BLE-485C user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Disposable Probe Adapter Part Number 2508-P-8026
Instructions for use
The system automatically initiates a purging
cycle of 90 seconds. During the purge cycle an
animated Wait Symbol is displayed alongside
the Probe Symbol.
Three short beeps signal that the purge cycle is
complete. The equipment is now ready for use
as indicated by the timer and the Ready Symbol.
Freezing cycles can now be controlled by the Cryomatic
footswitch as normal (see Cryomatic user manual).
Warnings and Precautions
• Only to be used in conjunction with Keeler
Cryomatic (2509-P-1000) and Disposable Cryo
Probe (2508-P-7022)
• Check probe before use – do not use or repair
if damaged or deformed
• Disconnect probe from adapter only when
system is depressurised
• Maximum pressure 5860kPa (850psi)
• Consult Cryomatic instruction manual if in doubt
• Unauthorised interference invalidates warranty
• This device should be used by trained staff
experienced in the use of ophthalmic equipment
• USA federal law restricts this device to sale or
on the order of a physician
1
Connect the Probe Adapter to the Cryomatic console
by aligning the coupling on the console spigots
and pushing to a positive click (It is impossible to
connect the coupling the wrong way round – correct
orientation is with the release button uppermost).
Connect the disposable probe by inserting the probe
plug into the adapter and pushing the probe firmly
and squarely against the collar(1).
The safety latch(2) will operate and the locking
ring(3) will spring towards the probe to confirm that
the probe has been successfully connected.
Operation
2
Before use ensure that the rear safety
clip(4) is in the fully down position
- under no circumstances should it
be used if the safety clip is not in
position (refer to image on page 2).
1
2
4
3
Sterilized using Ethylene Oxide
Manufacturer
Caution
The CE mark on this product indicates
it has been tested to and conforms
with the provisions noted within the
93/42/EEC Medical Device Directive
Do Not Reuse
Use By
Batch Code/Lot Number/Batch Number
Consult Instructions For Use
This Symbol on the Product or on its
Packaging and instructions indicates
that it was put on the market place
after August 2005 and that this
product shall not be treated as
Household Waste. EU only.
Symbols
3
0088
Continued overleaf
1
2
4
3
The disposable probe should only be removed from the adapter
when the system is depressurised as indicated by the ready symbol.
Disconnecting the disposable probe
4
2509-P-8019 Issue E
To disconnect the disposable probe from the
Probe Adapter move the locking ring(1) away
from the disposable probe and operate the
latch(2).
The disposable probe should be gently ejected
from the adapter. Lift the safety clip(3) and remove
the disposable probe plug from the adapter.
The Probe Adapter can itself be removed from
the Cryomatic Console by operating the release
button(4).
2 years against faulty workmanship, materials and labour. Warranty will be conditional on
routine maintenance and will not cover calibration or mechanical issues caused as a result of
lack of maintenance, poor use, incorrect transport or inappropriate storage conditions.
If necessary, the Probe Adapter can be cleaned using a
disposable cloth soaked in mild detergent and warm
water. Do not use abrasive compounds or pads. The user
should avoid getting electrical contacts wet during the
cleaning process.
There are no user serviceable parts in the Probe
Adapter and operator maintenance is restricted to
inspection of the adapter for signs of damage before
every use.
The Probe Adapter should be inspected annually by
Keeler trained personnel.
Repairs should be carried out by
Keeler trained personnel or their
representatives.
Ensure that this equipment is disposed of
in accordance with local regulations.
Please contact the supplier if in doubt.
Product warranty
6
Manufactured by
Keeler Limited, Clewer Hill Road, Windsor, Berkshire, SL4 4AA UK
Freephone: 0800 521251 Tel: +44 (0)1753 857177 Fax: +44 (0)1753 827145
Distributed by
USA Sales Office, Keeler Instruments Inc, 3222 Phoenixville Pike, Building #50, Malvern,
PA 19355, USA. Toll Free: 1 800 523 5620 Tel: 1 610 353 4350 Fax: 1 610 353 7814
Cleaning, maintenance and disposal
5