Roofventing
Salida dealre perel cielo raso
roof cap
caperuzade cieth raso
3+1/4"x16"through+the*roof
atravgsdelciethrasopotanoriUcth
de3+1/4"x 10
Wall venting
Salida de alre por la pared wallcap
caperaz_depared
3+1/4"x 10" through*the+wall
a tray,s de la pared porun
oriUciode 3+1/4"x 10
Roundventtransition
Transici6nde conductode salidade aire redondo
root cap
caperuzade
¢ie]o raso
6" rain. diameter round vent _wall cap
conductode salida de aire
redondo de 6" de di_metro de pared
minimo elbow
UOdO
continuedfrompage7
Forwall or roofventingmethods:
Choose betweenroof venting or wall venting.
If the wall exhaust method is chosen, be sure that there is
proper clearancewithin the wall for the exhaust vent.
Vent materialsneededfor installationare notincluded.
Wall and roofcapsmust haveback-draftdamper.
We recommend:
v' using rigid metal vent.
v' that length of vent and number of elbows should be
kept to a minimum to provide efficient performance.
v' that size of vent should be uniform.
v' using duct tape to seal all joints inthe vent system.
v' using caulking compound to seal exterior wall or roof
opening around cap.
v' two elbows should not be installed together.
We do NOTrecommend:
v' flexible metal vent.
NOTE:If flexible metal vent must be used, calculate each
foot of flexible metal vent as two feet of rigid metal vent.
Flexiblemetal elbows count twice as much as standard
elbows.
vienedelap_,gina7
Para m_todos desalida de aire a travgsde la pared oel
cieio raso:
Decidaentre instalar la salida de airea travds del cielo raso o
de una pared.
Si se decide por el mdtodo de salida deairea travds de la
pared,aseg_resede que hayael espacio adecuadodentro de
la pared parael conducto de salidade aim.
No se incluyenlos materiales del conductode salida deaire
que se necesitanpara la instaiaci6n.
Las caperuzaspara cielo rasoy pareddeben tenet
compuertadecontratiro.
Recomendamos:
v' usar un conducto de salidade aire met_lico y rigido.
v' que la Iongitud del conducto de salida de aire y el n_mero
de codos se mantengana un minimo paraIograr un
rendimiento eficiente.
v' que las dimensiones del conducto sean uniformes.
v' usarcinta pareconducto para sellartodas las uniones en el
sistema de salida de aire.
v' usar masilla parecalafatearparasellar la pared exterior ola
abertura en el cielo rasoalrededor de la caperuza.
v' no se deben instalar dos codos juntos.
No recomendamos:
v' conducto de salida de aire met_lico flexible
NOTA:si debeusarse un conducto metdlico flexible, calcule
cada pie de conducto metdlicoflexible como si fueran dos pies
de conducto metdlico rigido. Los codos de metal flexible hacen
por dos codos estdndar.
3" minimum height (required
for damper to fully open)
Alturaminimade3"
(necesaria para que la
compaerta se abra
compthtamente)
3+1/4"x 10"to 6" roundvent
transition
transici6nde conductode salida
de aire redondode 3+1/4"x 10"
a 6"
8
Recommendedstandardfittings
Accesoriosest_ndarrecomendados
3-1/4"x 10"to6"= 5ft.
De3-1/4"x10_a6+=
5pies
3-1/4"x10_roofcap=24ft.
Caperuzadecielorasode
3-1/4"x10_=24pies
3-1/4"xle'
90°elbow= 25ft.
Codode90oy3-1/4"x
10_=25pies
90°elbow=tOft
Codode90_=
10pies
3-1/4+x 10"watlca
=40ft.
C_eruzadepared
de3-1/4+x 10"=
40pies
_5° elbow=5ft
,';odode45°=
pies
_-1/4"x 10"fiat
_lbow=10ft.
;odop_o de3-1/4"
(10'= t0pies
3-1/4"x 10" ventsystem
Sistemade salidade aire de 3-1/4"x 10"
3-1/4" x 16"
90+elbow
Codode 90+y 6 ft.
3-1/4"x 1_ _6pies _ n wall cap
/II1 /saporu,aan
'1t-> parnd
2_t. (2 pies)
6"vent system
Sistemade salidade aire de 6"
90+elbows
cododego°
transition
transini6n
0 pies
2 ft. (2 pies)
Recommendedventlength:
Use3-1/4° X 10" rectangular or 6" round vent.
Thetotal length of the vent system including straight vent,
elbow, transitions, wall or roof caps must not exceedthe
equivalent of 140 feet of 3-1/4" X 10" rectangular or 6"
diameter round vent.
Forbest performance, use no more than three 90 degree
elbows.
Tocalculatethe length of system you need,add the
equivalent feet for each vent piece used in the system. See
the following examples:
3-1/4"x 10" ventsystem:
1 - 3-1/4" x 10"
90° elbow = 25 ft.
1 - wall cap = 40 ft.
8 feet straight = 8 ft.
Length of
3-1/4" x 10" system = 73 ft.
6"vent system:
1 - transition = 5 ft.
2 - 90+ elbows = 20 ft.
1 - wall cap = 40 ft.
8 feet straight = 8 ft.
Lengthof 6" system = 73 ft.
If the existing vent is round, a rectangular-to-round adapter
must be usedand a rectangular 3" extension vent between
the damper assembly and adapter must be installedto
preventdamper from sticking.
Longitudrecomendadadel conductode salidade aire:
Useun conducto de salidadeaire rectangularde 3-1/4_x 10"
o redondo de 6".
La Iongitud total del sistema de salida de aire, incluyendo el
conducto de salida de aire recto, el codo, las transiciones, las
caperuzasde pared o cielo raso no deben excederel
equivalentea 140 pies de conducto rectangular de salida de
aire de 3-1/4" x 10" o conducto redondo de 6" de didmetro.
Paramejores resultados, no use m_s de tres codos de 90°.
Paracalcular la Iongitud del sistema que necesita,agregue la
equivalenciaen pie paracadapedazode conducto usado en el
sistema. Vealos siguientesejemplos:
Sistemade salidade aire de 3-1/4"x 10":
1 - Codo de 90°
y 3-1/4" x 10" = 25 pies
1 - Caperuzade pared = 40 pies
8 pies recto = 8 pies
Longitud de un
sistema de 3-1/4"x 10" = 73 pies
Sistemade salidade aire de 6"
1 -transiciSn = 5 pies
2 - codos de 90+ 20 pies
1 - caperuzade pared = 40 pies
8 pies recto 8 pies
Longitud de un
sistema de 6" = 73 pies
Si el actual conducto de salida de aire es redondo, debe usarse
un adaptadorde rectangulara redondo y un conducto de
extension rectangular de 3" entre el conjunto de la compuerta
y se debe instalar el adaptador pare evitar que la compuerta se
atasque.
9