12
DPX302,DPX-MP2100
↓
[FM]
key
CD ejection error log display (switched by [ ] / [ ] keys)
(Display) EJERR1: xx ↔EJERR2: xx ↔EJERR3: xx ↔
EJERR4: xx ↔EJERR1: xx ↔
(Number of times is displayed for “xx”)
MAX 99 (times)
CD time code error count data display (missing counts)
(switched by [ ] / [ ] keys)
(Display) CNT_LOSE ↔CDDA_ _: xx ↔CDROM_: xx ↔
CNT_LOSE ↔
(Number of times is displayed for “xx”)
MAX 99 (times)
CD time code error count data display (count not updated)
(switched by [ ] / [ ] keys)
(Display) CNT_STAY ↔CDDA_ _: xx ↔CDROM_: xx ↔
CNT_STAY ↔
(Number of times is displayed for “xx”)
MAX 99 (times)
●Initializing AUDIO-related setting value
Press the [ ] key in the STANDBY source and reset the
AUDIO setting value to the test mode default value.
●Other
• When Power ON, do not display “CODE_OFF” and
“CODE_ON”.
• When the source is STANDBY, press and hold [AUTO]
key for 1 second to switch PREOUT Rear and Sub
Woofer. (2PREOUT model)
• When started in Test Mode, duration of prohibiting LINE
MUTE shall be changed from 10 seconds to 1 second.
• While in Test Mode, serial number is not written with a
serial-number-writing jig.
• When in Test Mode, when DC offset error detection is run,
the detection information is not written into the E2PROM.
• DEMO mode shall not be operated while in Test Mode,
CD Mechanism Error Log Data Clearing Mode, or DC
Offset Error Detection Data Clearing Mode.
Also, do not display DEMO ON/OFF option items in the
MENU in STANDBY source in the above modes.
●Clearing CD mechanism information and
service
information (Clearing E2PROM (F/E) data)
1. While pressing the [EQ] key and [ATT] key, reset-start to
start CD mechanism and service information initialization.
(While “– – – –” is being displayed, power can be ON for
30 minutes.)
[CD mechanism information]
• Displays I2C communication condition
• Displays CD mechanism error log
• Displays CD loading error data.
• Displays CD ejection error data
• Displays CD time code error count data (missing count)
• Displays CD time code error count data (count not
updated)
[Service information]
• Displays power ON time is displayed
• Displays CD operation time
• Displays number of CD EJECT times
• Displays forced Power OFF data
2. After the initialization process is completed, the following
is displayed.
When successfully completed: “CD_O_ _ _ _”
When finished but unsuccessful: “CD_X_ _ _ _”
3. This mode is cancelled by resetting. (The last screen will
not be retained.)
●Clearing DC error detection data
(E2PROM (F/E) data clearing)
1. Press and hold [3] and [6] keys and reset-start to go into
the DC offset error display mode.
(While “– – – –” is being displayed, power can be ON for
30 minutes.)
2. While in STANDBY source, the current DC offset error
condition is displayed.
When detected: “DC_ERR_ _”
When not detected: “DC_OK_ _ _”
3. While error condition is being displayed, press [AUTO]
key briefly to clear the detection data. (clear E2PROM)
4. DC error display mode is cancelled by resetting. (The last
screen will not be retained.)
●Frequency span switching (K/M type)
While pressing and holding [1] and [5] keys, press [SRC]
key simultaneously to power ON.
●Security
• Forced Power-ON mode (all models)
Even when security is permitted, by pressing and holding
[EQ] and [4] keys and pressing RESET simultaneously,
Power can be ON for 30 minutes. After 30 minutes,
recovered only by reset.
TEST MODE