KeriSystems MS-7000 SuperStar User manual

MS-7000: SuperStar Reader
2305 Bering Drive 01826-001 Rev. G
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
MS-7000Quick Start Guide
The MS-7000 SuperStar Reader
The MS-7000 SuperStar Reader is intended for installation in proximity applications where an
extended read range is required. The reader provides an audible beeper and a multi colored LED to
annunciate the reader's status when used on a PXL-250, PXL-100, or IntelliProx.
• Amber - to indicate normal operation awaiting an access event
• Green - to indicate a valid card has been presented or the door has been unlocked for access
• Red - to indicate an invalid card has been presented or the door is in an alarm condition
The MS-7000 SuperStar Reader is housed in a black or white, weatherproof, shock resistant
package. The reader provides optimum performance when mounted at least four inches away from
metal surfaces; read range is reduced if the reader is mounted on or near metal surfaces.
1.0 Specifications
1.1 Dimensions
• 8.50 inches High x 6.00 inches Wide x 0.75 inches Deep
• 21.59 cm High x 15.24 cm Wide x 1.91 cm Deep
Figure 1: MS-7000 Dimensions

MS-7000: SuperStar Reader
2305 Bering Drive 01826-001 Rev. G
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Quick Start GuideMS-7000
1.2 Operating Voltage
• 11v to 14v DC @ 200 ma
1.3 Cable Specifications
• up to 250 feet using six conductor, shielded, stranded AWG 24 wire
• up to 500 feet using six conductor, shielded, stranded AWG 20 wire
2.0 Mounting Instructions
Five holes need to be drilled to mount the SuperStar Reader (see Figure 1 on page 1). One hole
(0.375" – 3/8") accommodates the reader cable. Four holes are for mounting the reader on a wall
surface (hole size is dependent upon the size of the mounting screw - a #10 screw is recommended).
A small recess may be necessary to accommodate the beeper (0.75" – 3/4" x 0.20" Deep).
For parking or similar applications, the SuperStar Reader can be mounted to a metal "gooseneck"
stand. Since the Reader cannot be mounted directly to a metal surface without affecting read range,
the Reader must be mounted on some kind of a nonmetallic mounting plate, which is then mounted
to the gooseneck stand. The larger the mounting surface of the gooseneck stand, the greater the
distance required between reader and mounting surface.
A nonmetallic (PVC) mounting plate is provided for these applications. For a stand with a mounting
surface of 4 inches by 4 inches or smaller, the MP-7 mounting plate provides 1/2 inch of separation
between the reader and the gooseneck mounting surface. If the mounting surface is larger than these
dimensions, additional mounting plates may be necessary to provide the necessary distance
between Reader and stand to ensure optimum read range (available from Keri Systems – p/n MP-7).
NOTE: Do not mount the reader near sources of Electromagnetic Interference (EMI) such as a
computer monitor. EMI degrades a reader's read range.
3.0 Connections
The SuperStar Reader does not require configuration; there are no switches or jumpers to set. The
SuperStar Reader is normally connected to a PXL-250, PXL-100, or IntelliProx, but can be
connected to an alternative host controller/alarm panel through an IntelliProx used in its Wiegand
input device mode. All connections needed to support the reader are made through the reader's
cable. Please consult the tables on pages 2 and 3 for specific connection instructions.

MS-7000: SuperStar Reader
2305 Bering Drive 01826-001 Rev. G
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
MS-7000Quick Start Guide
3.1 PXL-250 Connections
The "A" reader connects to TB5, pins 1 through 6 (TB5 has a seventh pin, but no connection is
made to that pin). The "B" reader connects to TB6, pins 1 through 6 (TB6 has a seventh pin, but no
connection is made to that pin).
Connecting to the PXL-250 –TB5 or TB6
Figure 2: PXL-250 Connections
3.2 Design 5 PXL-100 Connections
The "A" reader connects to TB2, pins 14 through 19. The "B" reader connects to TB3, pins 20
through 25.
Pin # Function Wire Color
1 Reader Antenna Blue
2 Beeper Green
3 Reader Power Red
4 Reader Ground Black
4 Shield Silver
5 Green LED Brown
6 Red LED White
7 no connection –

MS-7000: SuperStar Reader
2305 Bering Drive 01826-001 Rev. G
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Quick Start GuideMS-7000
Connecting to the PXL-100 – TB2 Connecting to the PXL-100 – TB3
Figure 3: Design 5 PXL-100 Connections
NOTE: Please contact customer support at Keri Systems for information regarding connecting a
Reader to a Design 4 PXL-100. A Design 4 PXL-100 can be identified by the location of its power
connection made at the middle of the left edge of the printed circuit board.
Pin # Function Wire Color Pin # Function Wire Color
14 Green LED Brown 20 Green LED Brown
15 Beeper Green 21 Beeper Green
16 Reader Power Red 22 Reader Power Red
17 Reader Ground Black 23 Reader Ground Black
17 Shield Silver 23 Shield Silver
18 Reader Antenna Blue 24 Reader Antenna Blue
19 Red LED White 25 Red LED White

MS-7000: SuperStar Reader
2305 Bering Drive 01826-001 Rev. G
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
MS-7000Quick Start Guide
3.3 IntelliProx Connections
The reader connects to TB1, pins 1 through 6.
Connecting to the IntelliProx – TB1
Figure 4: IntelliProx Connections
Pin # Function Wire Color
1 Reader Antenna Blue
2 Beeper Green
3 Greeen LED Brown
4 Red LED White
5 Reader Power Red
6 Reader Ground Black
6 Shield Silver

MS-7000: SuperStar Reader
2305 Bering Drive 01826-001 Rev. G
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Quick Start GuideMS-7000
4.0 Installation Verification
The following information applies to an installation with a Keri Systems controller or IntelliProx
unit. When used with an alternative host controller/alarm panel through an IntelliProx used in its
Wiegand input device mode, the actions of the reader's LED and beeper are controlled by the
alternative host controller/alarm panel and might not match those of a Keri Systems controller.
The reader's power is provided by the controller, so the reader is powered on when the controller is
powered on. The reader's normal state is to display a constantly on Amber LED as it waits for a card
or tag to be presented.
To verify the reader is functioning properly, pass a Keri Proximity Card or a Keri Key Tag within a
few inches of the reader. The reader will beep and either the Green or Red LED will flash
(depending upon whether or not the card/tag has been enrolled at the controller) and then return to
steady Amber.
To verify the reader's read range, hold a Keri Proximity Card or a Keri Key Tag parallel to the
reader, about 2 feet away and slowly draw the Card/Tag in toward the reader. Note the distance
when the reader recognizes the card. The SuperStar reader's range will be up to 14 inches for a card
and 7 inches for a tag depending upon the installation conditions, the material on which the reader is
mounted, and whether it is a card or a tag being read. Due to the physical size difference between
cards and tags, tags provide approximately 50% less read range than cards.
Refer to the Troubleshooting the Reader Installation section beginning on page 7 if the reader is not
functioning properly.

MS-7000: SuperStar Reader
2305 Bering Drive 01826-001 Rev. G
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
MS-7000Quick Start Guide
5.0 Troubleshooting the Reader Installation
Problem Probable Cause Corrective Action
The reader does
not recognize a
card/tag (no
beep, no LED
flash).
1. One or more of the
reader's wiring
connections are
incorrect.
• Power down the controller and verify the
wiring connections are correct for the
reader/controller combination per the
instructions provided in the Connections
section on pages 2 and 3.
2. The reader is not
receiving proper power
from the controller.
• Verify the voltage supplied to the reader is
between 5 and 14 VDC.
3. The reader is mounted
too close to a device that
radiateselectromagnetic
interference.
• Devices such as computer monitors radiate
electromagnetic interference that affects
read range. When possible, relocate either
the reader or the device to provide a greater
distance between the two.
4. A jumper is not set
correctly on the
controller.
• For a PXL-250: Verify there is a jumper
across pins 1 and 2 of JP4 (refer to the
Technical Reference manual for more
information - Keri p/n 01836-001).
• For a PXL-100: If the controllers are using
TAPTM software, verify JP1 on the
controller and the jumper on the Receiver
card1are installed across both jumper pins.
If the controllers are using DoorsTM
software, verify JP1on the controller and
the Receiver card1 are not installed across
both pins (typically the jumper will be
installed onto one of the pins to keep it
available).
• For an IntelliProx: Verify there is not a
jumper across pins 1 and 2 of JP1
(typically the jumper can be installed onto
one of the pins to keep it available).
1. The receiver board's jumper is on the underside of the board. Gently pull the receiver board away from
the controller, verify the jumper setting is correct per your application, carefully align the connectors on
the receiver board with the pins on the controller, and gently push the receiver board back into place.
– continued next page –

MS-7000: SuperStar Reader
2305 Bering Drive 01826-001 Rev. G
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Quick Start GuideMS-7000
Problem Probable Cause Corrective Action
5. You are using an
incorrect type of card. • Make sure you are using an access card
that is compatible with the reader.
6. The reader is unable to
read the card. • Verify there is nothing that can interfere
between the reader and the access card.
The reader has a
short read range. 1. The reader's controller
is not properly
grounded.
• Ensure there is a quality earth ground
connection made to the controller. Refer to
the controller's documentation for specific
information regarding the earth ground
connection.
2. The shield wire for the
reader's cable has
opened somewhere
between the reader and
the controller.
• Verify the shield line from the controller to
the reader is one continuous, connected
line. Refer to the controller's installation
documentation and verify the shield line is
correctly connected to the controller.
3. The reader is mounted
too close to a metallic
object.
• Remove the reader from its mounting
surface and ensure there is no metal on the
mounting surface within 1 inch of the
reader.
4. The reader is mounted
too close to a device that
radiateselectromagnetic
interference.
• Devices such as computer monitors radiate
electromagnetic interference that affects
read range. When possible, relocate either
the reader or the device to provide a greater
distance between the two.
5. The controller is
mounted too close to a
device that radiates
electromagnetic
interference.
• Devices such as computer monitors radiate
electromagnetic interference that affects
read range. When possible, relocate either
the controller or the device to provide a
greater distance between the two.
6. The reader is powered
by a switching power
supply.
• Switching power supplies are EMI sources.
Change to a linear, regulated power supply.
Table of contents
Popular Gateway manuals by other brands

ViewSonic
ViewSonic PJ-WPD-200 user guide

Comcast
Comcast XFINITY installation guide

Paradyne
Paradyne WIRELESS DATA GATEWAY Installation and operation manual

Cisco
Cisco 545 Serial Installation and upgrade guide

DEUTSCHMANN AUTOMATION
DEUTSCHMANN AUTOMATION UNIGATE CL-MPI instruction manual

EtherWAN
EtherWAN EDGe 1 user guide