Kingdy SA Series User manual

Full IP LCD Monitor
Single Touch : SA / HA / DA / LA Series
Milti Touch : TA / UA / EA / VA Series
User Manual
User Manual

Contents
0-01
Chapter 2 Mounting Installation
Vesa Mount .........................................................................2-01
Chapter 1 General Information
Package
Safety Instructions
FCC & CE Statement
Product Introduction
Specification .....................................................................1-05
OSD Controller
.............................................................................1-01
..............................................................1-02
..........................................................1-03
............................................................1-04
....................................................................1-06
Collections ..........................................................................1-06

1-01
General Information
Package
Please make sure that the items shown below are included in the package.
Should an item be missing, please contact the local retailer from which you
purchased this product.
● 1 x Industrial Touch Monitor
● 1 x DC in Power Adapter
● 1 x Power Cord
● 1 x CD

1-02
General Information
Safety Instructions
Read Instructions: All the safety and operating instructions should be read before
the equipment is operated.
Retain Instructions: The safety and operating instructions should be retained for
future reference.
Cleaning: Unplug this equipment from the outlet before cleaning. Do not use
liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.
Water and Moisture: Do not use this equipment near water.
Ventilation: The openings on the enclosure are provided for ventilation to ensure
reliable operation of the equipment and to protect it from overheating. These
openings should never be blocked.
Power Sources: This equipment should be operated only from the type of power
source indicated on the rating label. If you are not sure of the type of power
supply, consult your dealer or local power company.
Heed Warnings: All warnings on the equipment and in the operating instructions
should be adhered to.
Object and Liquid Entry: Never push objects of any kind into this equipment
through openings as they may touch dangerous voltage points or shout-out parts
that could result in a fire or electric shock. Never spill liquid of any kind on the
equipment.
Servicing: Do not attempt to service this equipment yourself as opening or
removing covers may expose you to dangerous voltage or other hazards. Refer
all servicing to qualified service personnel.
Damage Requiring Service: Unplug this equipment from the outlet and refer
servicing to qualified service personnel under the following conditions: a) if the
power cord or plug is damaged; b) if liquid has penetrated into the equipment; c)
if the equipment has been exposed to moisture; d) if the equipment does not
work well, or you cannot get it to work according to the user’s manual; e) if the
equipment has been dropped and damaged; f) if the equipment has obvious
signs of breakage.
Do not leave this equipment in an environment where the storage temperature is
below -10°C (-25°C for specific wide-operating-temperature-range equipment) or
above 70°C. It may damage the equipment.
Do not open the sealed enclosure / case of equipment. Once enclosure is
disassembled without approval, it will lead in abnormal operating of water proof
gel. For Guarantee of water proof function, please make sure configuration /
peripheral has been confirmed to install before shipping.

1-03
General Information
FCC & CE Statement
This device complies with Part 15 FCC Rules. Operation is subject to the
following two conditions:
FCC
this device may not cause harmful interference, and
this device must accept any interference received including
interference that may cause undesired operation.
(1)
(2)
The product(s) described in this manual complies with all applicable
European Union (CE) directives if it has a CE marking. For computer
systems to remain CE compliant, only CE-compliant parts may be used.
Maintaining CE compliance also requires proper cable and cabling
techniques.
CE

1-04
General Information
Product Introduction
Single Touch Monitor
SM Series: Standard Condition
HM Series: Sunlight Readable
DM Series: Wide Temperature
LM Series: Wide Temperature & Sunlight Readable
Multi Touch Monitor
TM Series: Standard Condition
UM Series: Sunlight Readable
EM Series: Wide Temperature
VM Series: Wide Temperature & Sunlight Readable

1-05
General Information Specification
HA Series
Power Supply
I/O Ports (Default)
Operation Temperature
Storage Temperature
Relative Humidity
OS Support
Installation
Optional Items
Standard / IP65-rated DC in 12V (default) or DC in 19V ~ 36V (optional) external power adapter
1 x VGA, 1 x USB or RS232 for resistive touch screen
0°C ~ 45°C
-10°C ~ 70°C
0% ~ 95% non-condensing
Win 7 Pro, Embedded 7, Win XP Pro, Embedded XP
VESA mount 100 x 100 mm
None touch screen
Touch Function
OSD Controller Rear side
IP65 chassis, IP65 connectors,
IP65 power adapter (alternative)
Waterproof Design
Housing Design Stainless steel
Sunlight Readable Up to 1600 nit
Highlights
SA / HA / DA / LA / TA / UA / EA / VA Series
IP65 waterproof stainless steel connectors
to prevent liquid from getting into the housing via the cable entry points
Size / Aspect Ratio
Backlight
Resolution
Colors
Luminance (cd/m²)
Contrast Ratio
Viewing Angle (H/V°)
MTBF (hrs)
Touch Screen
Display
Model Name
Dimension (W x H x D, mm)
Weight (kg)
I/O port’s position
OSD Controller
12V
19~36V HA-ZJL17RF
HA-ZJL17RW
17" TFT (4:3)
LED
1280 x 1024
16.7 M
1000
1000:1
160/160
70,000
5-wire resistive
425 x 361 x 68
9
Rear
Yes (rear)
16.7 M
1600
1000:1
170/170
16.7 M
800
1000:1
170/170
HA-ZJL19RF
HA-ZJL19RW
19" TFT (4:3)
LED
1280 x 1024
16.7 M
1000
1000:1
160/170
70,000
5-wire resistive
455 x 367.6 x 67
10
Rear
Yes (rear)
16.7 M
1600
1000:1
170/160
16.7 M
800
1000:1
170/160
HA-ZJD21RF
HA-ZJD21RW
21.5" TFT (16:9)
LED
1920 x 1080
16.7 M
1200
1100:1
170/160
70,000
5-wire resistive
TBD
11
Rear
Yes (rear)
16.7 M
1600
900:1
170/160
16.7 M
1000
1000:1
170/160
HA-ZJL15RF
HA-ZJL15RW
15" TFT (4:3)
LED
1024 x 768
16.2 M
1000
700:1
160/160
70,000
5-wire resistive
380 x 290 x 67
8
Bottom
Yes (rear)
16.7 M
1600
700:1
160/160
16.7 M
800
700:1
160/160

1-06
General Information
Series
SA
HA
DA
LA
TA
UA
EA
VA
Category
Full IP65
Stainless
Steel
Chassis
Touch
Single
◎
◎
◎
◎
Multi
◎
◎
◎
◎
Condition
Std.
★
★
Sunlight
Readable
★
★
Wide
Temp.
★
★
Wide
Temp.
Sunlight
Readable
★
★
Panel Size
4:3
10.4" 12.1" 15"
V
V
V
V
V
V
V
V
17"
V
V
V
V
V
V
V
V
19"
V
V
V
V
V
V
8.4"
16:9
21.5"
V
V
V
V
15.6" 17.3"
OSD Controller
LED Indicator
Down Up
Power
MenuAuto Tuning
( I/O Port’s position - Bottom : for
15” Single Touch LCD Monitor only )
( I/O Port’s position - Rear )

2-01
VESA Mounting Installation
Screws
Screw Holes for VESA Mounting Installation
Step 1: screw the VESA mounting plate to the Panel PC
Step 2: screw the VESA mounting bracket to the front of a wall or the front /
back of an object dependingly
Step 3: slide the VESA mounting plate onto the VESA mounting bracket
VESA Mounting Bracket VESA Mounting Plate

Inspiring a reliable solution
Tel: 886-2-6621-8811
Fax: 886-2-8226-1518
Sales Email: sales@kingdy.com.tw
Technical Support Email: tech@kingdy.com.tw
http://www.kingdy.biz
10F, No. 2, Jian 8th Rd., Zhonghe Dist.,
New Taipei City 23511 Taiwan
User Manual
This manual suits for next models
24