The Kitchen Brains®Modularm®75LCT Touch Screen Multi-Monitor offers
the best in walk-in monitoring.
With Touch Screen convenience, the 75LCT provides temperature
alarms, door ajar alarms, AC failure alarms and panic alarms.
Using Autoset™ technology, the Modularm 75LCT automatically
adjusts alarm set points, thus eliminating the need for manual
programming. The system saves energy, improves eciency,
reduces coil icing, lowers maintenance costs and helps to
maintain product integrity.
Featuring:
• Built in battery back-up with recharging circuitry
• Patented energy act compliant light control activates by motion sensors!
75LCT MULTI-MONITOR | OPERATING MANUAL
ABOUT
OPTIONAL ACCESSORIES
IP-1 Illuminated Push Button
Panic/Entrapment Alarm
Kitchen Brains®Modularm IP-1 Illuminated
Push Button Panic/Entrapment Alarm is
an optional accessory that provides light
control, panic, and auto panic inside
the compartment.
• Works with the DAC-55, DL-35, 75LC
and Datalarm™.
• Entrapment Alarms.
• Panic Alarm
• Auto Light Control
MD-1
The MD-1™ adds hands free occupancy
detection to your walk in. Connected through
low voltage wiring to your 75LC multi-monitor™.
• Hands Free Auto-panic™
• Occupancy Detection
• Auto-Panic
• Auto Light Control
• No Reprogramming Needed
75LC COMMUNICATOR
Compact, dedicated system server that
works with the 75LC Multi-Monitor to
harvest data from connected devices.
• 24 Points of Temperature
• Secured Remote Access Password
• No Monthly Monitoring Fee
• View Historical Data and Customized
Reports via Online Access
75LC
This document contains confidential information. Dissemination, publication, copying, or duplication of this document or software described herein without prior written authorization is strictly prohibited.
kitchenbrains.com
Page 2of 16
© 2020 Kitchen Brains

0
This document contains confidential information. Dissemination, publication, copying, or duplication of this document or software described herein without prior written authorization is strictly prohibited.
kitchenbrains.com
Page 3of 16
© 2020 Kitchen Brains
NOTICES
Before you start, please read these instructions thoroughly in order to obtain maximum benet
from the capabilities that this product offers. Thank you for purchasing the 75LCT multi-monitor.
The 75LCT integrates sophisticated functions with easy programming and operation.
OVERVIEW
75LCT FUNCTIONS:
The 75LCT offers the following functions: (Patented Operation).
2. Autodetect accessories
3. AC Failure Alarm with built-in rechargeable battery and built in recharging circuitry
4. Door Ajar Alarm. (Requires magnetic contacts)
5. Panic (Entrapment) Alarm (Requires optional IP-1 Illuminated Button
6. Manual and patented timed light control
7. HACCP monitoring (additional equipment required)
8. Remote notication (additional equipment required)
9. Built in audible alarm
10. RS232 & RS485 Communication ports
11. Preventive Maintenance Reminder
12. Localized for German, Spanish, Portuguese and French markets
75LCT MULTI-MONITOR | OPERATING MANUAL

0
AUTOSET
WHAT IS AUTOSET?
Patented Autoset Technology selects the right alarm temp
setpoints for monitoring a cooler or a freezer automatically,
virtually eliminating the need for manual programming. Com-
mon cooler and freezer setpoints are pre-loaded into the 75LCT.
Autoset Setpoints are:
COOLER FREEZER
HI 42F (6C) HI 10F (-12C)
LO 30F (-1C) LO -20F (-29C)
Cooler setpoints are the default settings, used for cooler
monitoring. If the compartment is a freezer, Autoset detects
the lower compartment temperature and automatically
changes to the freezer setpoints. (Freezer defaults won’t
revert to cooler defaults if temperature rises. Cooler defaults
can be easily manually restored when necessary.) Manually
changing setpoints in the program menu automatically
disables Autoset.
WHAT IS AUTODETECT?
The Autodetect function in the 75LCT automatically senses
and integrates a connected Modularm accessory into device
operation. Additional conguration/setup is not required.
The 75LCT ships with Autodetect enabled, by default, for all
supported accessories. For example, If the magnetic door
contacts are not connected, the 75LCT operates as if there
arenomagneticcontacts.Oncemagneticcontactsareconnected,
Autodetect senses this and automatically includes door ajar
alarm function and automatic lights on function when the
door is open.
SUPPORTED ACCESSORIES:
1.IP-1IlluminatedPushButton–Thelow voltageIP-1isavailable
to be installed inside the Cooler/Freezer and provides the
ability to control the light within the Cooler/Freezer as well as
a mechanism to sound a panic alarm (press the IP-1 to turn
on/off the lights; press and hold for 2 seconds to manually
activate the Panic Alarm). A buzzer and light built into the
IP-1 warns personnel inside the Cooler/Freezer that lights
may turn off if the IP-1 isn’t pressed.
2. MD-1 & MD-1+2 Motion Detector – The low voltage MD-1/
MD-1+2 mounts inside of the Cooler/Freezer and duplicates
the light ON control function of the IP-1 button when activated
by movement of personnel inside of the Cooler/Freezer.
3. MC-1 Magnetic Contacts – Low voltage magnetic contacts
sense door status and provide both a door ajar alarm switch
and a lights on switch relative to the status of the door. One
set of magnetic contacts come with each 75LCT, various
styles are available.
ACCESSORIES:
Three accessories expand 75LCT operation:
1. IP-1 Illuminated Push Button
2. MD-1 & MD-1+2 Motion Detector
3. MC-1 Magnetic Contacts
These accessories are low voltage devices, connected directly
to and powered by the 75LCT. Accessories may be used
individually or in combination. To help eliminate programming
when common settings are desired, the 75LCT comes
equipped with Autodetect.
This document contains confidential information. Dissemination, publication, copying, or duplication of this document or software described herein without prior written authorization is strictly prohibited.
kitchenbrains.com
Page 4 of 16
© 2020 Kitchen Brains
75LCT MULTI-MONITOR | OPERATING MANUAL

0
75LCT MULTI-MONITOR | OPERATING MANUAL
DOOR AJAR Door Icon On
Door Ajar Message Light
Icon On
No Audible Alarm
TEMP OUT High Temp Alarm
OF RANGE Out of Range
No Alarm
Low Temp Alarm
Out of Range
No Alarm
ALARM TYPE ABNORMAL CONDITION ALARM CONDITION
TEMP OUT High Temp Alarm
OF RANGE Out of Range
Alarm Condition
Low Temp Alarm
Out of Range
Alarm Condition
AC POWER Low Temp Alarm
FAILURE Out of Range
Alarm Condition
This document contains confidential information. Dissemination, publication, copying, or duplication of this document or software described herein without prior written authorization is strictly prohibited.
kitchenbrains.com
Page 5 of 16
© 2020 Kitchen Brains
PANIC ALARM (Non Applicable)
DOOR AJAR Door Icon On
Door Ajar Message Light
Icon On
Audible Alarm
TABLE 1. Status of the 75LCT for Abnormal & Alarm Conditions
VISUAL ALARM ANNUNCIATION
VISUAL ALARM ANNUNCIATION:
NOTE the following:
1. During normal operation the monitored temp displays constantly
on the 75LCT.
2. Any abnormal condition (when temperature is out of range or door
is left open) triggers an error condition that is displayed on the LCD
screen. Alarm conditions (when abnormal condition exceeds preset
time delay) not only display the error, but also sound an alarm.
TOUCH SCREENS:
ALARM TYPE ABNORMAL CONDITION ALARM CONDITION
WHILE IN RUN OR ALARM MODE
Lights: Press to manually activate and
deactivate compartment
Silence: Press to acknowledge an alarm
Table of contents
Other Kitchen Brains Monitor manuals