0
FEATURES
This document contains confidential information. Dissemination, publication, copying, or duplication of this document or software described herein without prior written authorization is strictly prohibited.
kitchenbrains.com
Page 6 of 16
© 2020 Kitchen Brains
PANIC ALARM OPERATION:
MANUAL PANIC ALARM
Note: Panic Alarm requires the optional IP-1 switch installed in
the Freezer/Cooler.
A panic alarm can be triggered manually by holding down the the
IP-1 button for more than 2 seconds. The alarm can be cleared by
either pressing the Control Icon /Silence Icon displayed on the 75LCT
screen or by opening and closing the door for those installations
that have the MC-1 magnetic door contacts installed.
AUTO PANIC ALARM
Note: Autopanic function requires MC-1 magnetic contacts, and
either one or both of the IP-1 switch & MD -1/MD-1+2 motion
detectors installed in the Cooler/Freezer.
Auto Panic, when activated within the 75LCT setup, automatically
sounds a panic alarm when a person working inside the Cooler/
Freezer is unable to activate a panic alarm manually.
AUTOPANIC FUNCTION WITH THE IP-1 SWITCH:
When Autopanic is enabled, pressing the IP-1 at any time with the
door closed starts the 20-minute Auto Panic Timer. When the Auto
Panic timer runs out, the IP-1 starts to beep and blink for 40
seconds. Re-pressing the IP-1 during a beep and blink resets the
Auto Panic Timer for 20 minutes.
If during the 40 second interval the IP-1 is not pressed, a Panic
Alarm (HELP message) automatically annunciates on the 75LCT
to let others know that someone may be injured or disabled inside
the Cooler/Freezer. Auto Panic can be cleared by either pressing
the Control Icon /Silence Icon displayed on the 75LCT screen or by
opening and closing the door for those installations that have the
MC-1 magnetic door contacts installed.
AUTOPANIC FUNCTION WITH MOTION SENSOR/S
(MD-1 OR MD-1+2):
Addition of the Motion Sensor/s (MD-1/MD-1+2 ) to the Cooler/
Freezer automates the Autopanic function. Motion detected by
the sensors simulates a keypress on the IP-1 which automatically
restarts the 20-minute Auto Panic Timer. If no motion is detected
for 20 minutes the IP-1 (if present) starts to beep and blink for
40 seconds. During this time, if motion is not sensed a Panic Alarm
(HELP) automatically annunciates on the 75LCT to let others know
that someone may be injured or disable inside the Cooler/Freezer.
Auto Panic can be cleared by either pressing the Control Icon
/Silence Icon displayed on the 75LCT screen or by opening and
closing the door for those installations that have the MC-1 magnetic
door contacts installed.
AC POWER FAILURE OPERATION:
On an AC power failure, the 75LCT will chirp every 30 seconds and
display “Power Failure” on the Screen. After 1 minute, the alarm
relay activates for remote notication and the 75LCT will go dark
to conserve battery life. Clicking/pressing the darkened screen will
wake the unit and display the status on the screen.
For power failures under 1-minute normal operation restores
automatically and the incident is ignored.
LIGHTING CONTROL:
The 75LCT offers three ways to control lights:
1. Regular timed lighting
2. Patented timed lighting with Auto Panic (default)
3. Untimed, manual on-off light control (replaces light switches.)
Regular Timed Lighting (Default) – When lights are turned on
from the 75LCT interface, the lights-off timer will be activated.
The 75LCT will turn off the lights as soon as the lights-off
timer expires.
OPERATION:
Without Accessories: Press the Lights Button on the 75LCT to turn
lights on and start lights-off timer. Press the Lights Button again to
manually turn lights off before the lights-off timer expires.
With IP-1 installed: Press Lights Button on the 75LCT or IP-1 to
turn lights on and start lights-off timer. Press Lights Button or IP-1
Switch again to manually turn lights off before the lights-off timer
expires. The IP-1 blinks and beeps for 40 seconds before lights-off
timer expires to warn personnel that light will turn off soon. Pressing
the IP-1 when it is blinking/beeping resets the lights-off timer and
keeps lights on. If no action is taken the lights will turn off when
lights-off timer expires.
With Magnetic Contacts installed: Open the door to turn lights on.
75LCT light button and installed IP-1 will allow user to turn lights on
or off only with door open. When door is closed, can only turn the
light on, but not off. Once the door is closed the lights-off timer will
begin. However, If a user Opens the door, then turns off the light
(either by pressing the 75LCT light button or the IP-1), closes the
door without going inside the Cooler/Freezer, then lights-off timer
will be cancelled.
With MD-1 or MD-1+2 motion detector installed: Activation of the
MD-1 or MD-1+2 by movement of personnel inside the walk-in will
turn the lights On. When personnel are no longer detected inside the
Cooler/Freezer the lights will turn off.
75LCT MULTI-MONITOR | OPERATING MANUAL