KITOTEC KITOCAM User manual

KITOCAM Auto Focus HDMI C-mount CMOS Camera
1/ 19
KITOCAM Auto Focus HDMI Camera User
Manual
1Basic Characteristic
This camera is a multiple interfaces (HDMI+WiFi+SD card, so Xhere means multiple interfaces) CMOS
camera with autofocus function (Fmeans autofocus) and it adopts ultra-high performance Sony CMOS sensor
as the image-picking device. HDMI+WiFi are used as the data transfer interface to HDMI display or computer.
For HDMI output, The XCamView will be loaded and a camera control panel and toolbar are overlaid on
the HDMI screen, in this case, the USB mouse can be used to set the camera, browse and compare the captured
image, play the video ital.
In HDMI output, the camera embedded Auto/Manual focus function can obtain the clear image at ease.
No hand rotation of the microscope Coarse/Fine knob is needed.
For WiFi output, unplug the mouse and plug in the USB WiFi adapter, connect the computer WiFi to the
camera, then the video stream can be transfer to computer with the advanced software.
Figure 1
The camera basic characteristic is as follows:
All in 1( HDMI+WiFi) C-mount camera with Sony high sensitivity CMOS sensor;
Auto/Manual focus with the movement of the sensor;
For HDMI application, with built-in multiple-language XCamView software. The camera
characteristic can be controlled by XCamView through the USB mouse. The other basic
processing and control can also be realized by the XCamView;
1920 × 1080 (1080P) resolutions to match the current high-definition displayer on the market;

KITOCAM Auto Focus HDMI C-mount CMOS Camera
2/ 19
Support plug and play application;
For HDMI application, 2.0M resolution image(1920*1080) can be captured and saved for
browsing; For video, 1080P video stream(asf format) can be captured and saved;
With the USB WiFi adapter, the camera can be used as WiFi camera, the advanced image
processing software is used to display the video and capture image. support plug and play
application;
Ultra-Fine Color Engine with perfect color reproduction capability(WiFi);
With advanced video & image processing application software, which including professional
image processing such as 2D measurement, HDR, image stitching, EDF(Extended Depth of
Focus), image segmentation & count, image stacking, color composite and denoising(USB);
The camera can meet various applications and can be widely used in industrial inspection,
education and research, materials analysis, precision measurement, medical analyses etc.
The possible applications of the camera as follows:
Scientific research, education (teaching, demonstration and academic exchanges);
Digital laboratory, medical research;
Industrial visual (PCB examination, IC quality control);
Medical treatment (pathological observation);
Food (microbial colony observation and counting);
Aerospace, military (high sophisticated weapons);

KITOCAM Auto Focus HDMI C-mount CMOS Camera
3/ 19
1.1 Datasheet(1)
Order Code Sensor &
Size(mm) Pixel(μm) G Sensitivity
Dark Signal FPS/Resolution Binning Exposure
KITOCAM
1080P/2M/Sony
IMX185(C)
1/1.9"(7.20x4.05)
3.75x3.75 1120mv with 1/30s
0.15mv with 1/30s
60/1920*1080
(HDMI)
25/1920x1080
(WiFi)
1x1 0.06ms~918ms
C: Color; M: Monochrome;
Interface & Button Functions
USB USB Mouse/USB WiFi Adapter
HDMI HDMI Output
DC12V 12V/1APower in
SD SD Card Slot
ON/OFF Power On/off Switch
LED Power Indicator
Other Specification for HDMI Output
UI Operation With USB Mouse to operate on the embedded XCamView
Image Capture JPEG Format with 2M Resolution in SD Card
Video Record ASF Format 1080P 30fps in SD Card(8G)
Camera Control Panel Including Exposure, Gain, White Balance, Color Adjustment, Sharpness and Denoising Control
Toolbar Including Zoom, Mirror, Comparison, Freeze, Cross, Browser Function, Muti-language and XCamView
Version Information
Other Specification for WiFi Output
UI Operation software on Windows/Linux/OSX/Android Platform
WiFi Performance 802.11n 150Mbps; RF Power 20dBm(Maximum)
Maximum Connected Devices 3~6(According to the Environment and Connection Distance)
White Balance Auto White Balance
Color Technique Ultra-FineTM Color Engine (WiFi)
Capture/Control API Standard SDK for Windows/Linux/Mac(WiFi)
Recording System Still Picture or Movie (WiFi)
Software Environment (for USB2.0 Connection)
Operating System
Microsoft® Windows® XP / Vista / 7 / 8 / 8.1/10(32 & 64 bit)
OSx(Mac OS X)
Linux
PC Requirements
CPU: Equal to Intel Core2 2.8GHz or Higher
Memory:4GB or More
USB Port:USB2.0 High-speed Port(As Power Only, not as the USB Data Transfer)
Display:19” or Larger
CD-ROM
Operating Environment
Operating Temperature(in
-10~ 50

KITOCAM Auto Focus HDMI C-mount CMOS Camera
4/ 19
Centidegree)
Storage Temperature(in
Centidegree) -20~ 60
Operating Humidity 30~80%RH
Storage Humidity 10~60%RH
Power Supply DC 12V/1A Adapter

KITOCAM Auto Focus HDMI C-mount CMOS Camera
5/ 19
1.2 Camera and Microscope
Figure 2 and Its Back Panel
Figure 3 Different Views
Figure 4 with Microscope

KITOCAM Auto Focus HDMI C-mount CMOS Camera
6/ 19
1.1.1 Dimensions
Figure 5 Dimension

KITOCAM Auto Focus HDMI C-mount CMOS Camera
7/ 19
1.1.2 Packing Information
Figure 6Packing Information of
Standard Packing List
A
Gift box : L:25.5cm W:17.0cm H:9.0cm (1pcs, 1.43Kg/ box)
B
HDMI Camera
C
Power Adapter: Input: AC 100~240V 50Hz/60Hz, Output: DC 12V 1A
American standard:
Model: GS12U12-P1I 12W/12V/1A: UL/CUL/BSMI/CB/FCC
EMI Standard:EN55022,EN61204
-3, EN61000-3-2,-3, FCC Part 152 class B, BSMI CNS14338
EMS Standard:EN61000
-4-2,3,4,5,6,8,11,EN61204-3,Class A Light Industry Standard
European standard:
Model:GS12E12-P1I 12W/12V/1A; TUV(GS)/CB/CE/ROHS
EMI Standard:EN55022,EN61204
-3, EN61000-3-2,-3, FCC Part 152 class B, BSMI CNS14338
EMS Standard:EN61000
-4-2,3,4,5,6,8,11,EN61204-3,Class A Light Industry Standard
D
HDMI Cable
E
USB Mouse
F
W
ireless network adapter with USB interface
G
CD (Driver & utilities software, Ø12cm)
Optional Accessory
H Adjustable lens adapter
C-Mount to Dia.23.2mm Eyepiece Tube
(Please choose 1 of them for your microscope)
108001/AMA037
108002/AMA050
108003/AMA075
C-Mount to Dia.31.75mm Eyepiece Tube
(Please choose 1 of them for your telescope)
108008/ATA037
108009/ATA050
108010/ATA075
I Fixed lens Adapter
C-Mount to Dia.23.2mm Eyepiece Tube
(Please choose 1 of them for your microscope)
108005/FMA037
108006/FMA050
108007/FMA075
C-Mount to Dia.31.75mm Eyepiece Tube
(Please choose 1 of them for your telescope)
108011/FTA037
108012/FTA050

KITOCAM Auto Focus HDMI C-mount CMOS Camera
8/ 19
108013/FTA075
Note: For H and I optional items, please specify your camera type(C-mount, microscope camera or telescope camera), our
engineer will help you
to determine the right microscope or telescope camera adapter for your application;
J 108015(Dia.23.2mm to 30.0mm Ring)/Adapter rings for 30mm eyepiece tube
K 108016(Dia.23.2mm to 30.5mm Ring)/ Adapter rings for 30.5mm eyepiece tube
L Calibration kit
106011/TS-M1(X=0.01mm/100Div.);
106012/TS-M2(X,Y=0.01mm/100Div.);
106013/TS-M7(X=0.01mm/100Div., 0.10mm/100Div.)
M SD Card(4G or 8G)

KITOCAM Auto Focus HDMI C-mount CMOS Camera
9/ 19
1.1.3 Extension of camera with Microscope or Telescope Adapter
Extension Picture
C-mount Camera
Machine vision; Medical imaging;
Semiconductor equipment; Test instruments;
Document scanners; 2D barcode readers;
Web camera and security video;
Microscope
imaging;
Microscope Camera
Telescope Camera:

KITOCAM Auto Focus HDMI C-mount CMOS Camera
10 / 19
2The Camera Rear Cover Function
Figure 7 The Layout of Camera Rear Cover
The camera is a HDMI camera with auto focus function. Through the precise control of the sensor position, the
image can be focused automatically for the stereo or biological microscope. However, this autofocus principle will
destruct the microscope’s imaging conjugate principle and we think only a minor focus adjustment can be made to
keep the image with high quality.
But for the online basic observation, the camera can greatly increase the working efficiency and eliminate
manual focus operations.

KITOCAM Auto Focus HDMI C-mount CMOS Camera
11 / 19
3Quick Instructions for camera
Before starting the camera please connect the standard C-mount camera to camera adapter and connect it to the
microscope’s 3rd tube which will relay microscope object’s middle image to the camera sensor.
3.1 WiFi Mode
1. Plug 12V/ 1A power cable into Power Interface ③to supply power for the camera. The LED Indicator ⑥will
turn into red;
2. Press ON/ OFF Button ⑤to start the camera and the LED Indicator ⑥will turn into blue;
3. Plug the WiFi antenna which comes with the camera into WiFi ANTENNA/ USB PORT ②to generate WiFi signal;
4. After the indicator on the WiFi antenna starting blinking, connect computer (may be Pad or Phone) to WiFi signal
whose name starts with BHDC-AFC202M. The Password is 12345678;
5. Open software, start by clicking the camera model name listed in Camera List.
3.2 HDMI MODE
1. Plug the HDMI cable into the HDMI Port ①to connect the camera to HDMI display;
2. Plug a USB mouse into USB Port ②to get control of the camera by using built-in software XCamView;
3. Plug 12V/ 1A power adapter into Power Interface ③to supply power for the camera. The LED Indicator ⑥
will turn into red;
4. Insert SD card into SD Card Slot ④for saving captured images and recorded videos;
5. Press ON/ OFF Button ⑤to start the camera. LED Indicator ⑥will turn into blue;
6. Move mouse cursor to the left side of the video window, The Camera Control Panel will appear. It includes
Manual/ Automatic Exposure, White Balance,Sharpness, Denoise and other functions, please refer to 2.3 for details;
7. Move the mouse cursor to the upper side of the video window, a Measurement Toolbar with calibration and other
measurement tools will appear, please refer to 2.3 for details; The measurement data can be output with *.CSV
format.
8. Move the mouse cursor to the bottom of the video window and a Synthesis Camera Control Toolbar will appear.
Operations like Zoom In, Zoom Out, Flip, Freeze, Cross Line, WDR and etc. can be realized. Please refer to 2.3 for
details;
9. Move the mouse cursor to bottom of the video window, the Synthesis Camera Control Toolbar will pop up
automatically. Click the button and Auto Focus Control Panel will show up for conducting autofocus
operation;

KITOCAM Auto Focus HDMI C-mount CMOS Camera
12 / 19
3.3 Brief Introduction of the Camera and Functions
The camera UI shown in Fig. 8 includes the Camera Control Panel on the left side of the video window, the
Measurement Toolbar on the upper side of the video window, the Synthesis Camera Control Toolbar on the bottom of
the video window and the Auto Focus Control Panel on right side of the video window.
Figure 8 The Camera Control UI
Notes
1
When users move the mouse cursor to the left side of the video window, the
Camera Control Panel
will pop up
automatically;
2 When users move the mouse cursor to the bottom of the video window, the Synthesis Camera Control Toolbar
will pop up automatically;
3 When user moves the mouse cursor to the bottom of the video window, the Synthesis Camera Control Toolbar
will pop up automatically. Click the button and the Auto Focus Control Panel will appear for autofocus
operation;
4 Move the mouse cursor to the upper side of the video window, the Measurement Toolbar will pop up for the
calibration and measurement operations. When user left-clicks the Float/Fixed button on the Measurement
Toolbar, the Measurement Toolbar will be fixed. In this case the Camera Control Panel
will not pop up
automatically even if users move mouse cursor to left side of the video windows. Only when user left-clicks
the button on the Measurement Toolbar to exit from measuring procedure will they be able to do other
operations on the Camera Control Panel, Auto Focus Control Panel or Synthesis Camera Control Toolbar. During
the measuring process, when a specific measuring object is selected an Object Location & Attributes Control Bar
will appear for changing location and properties of the selected objects.

KITOCAM Auto Focus HDMI C-mount CMOS Camera
13 / 19
3.3.1 The Camera Control Panel on the Left Side of the Video Window
Camera Control Panel
Function
Function Description
Snap
Capture or
Snap
image from the current video window
Record
Record video from the current video window
Auto Exposure
When Automatic Exposure is checked, the system
will automatically
adjusts exposure time according to the value of Exposure Compensation
value
Exposure
Compensation
Available when Auto Exposure is checked. Slide to left or right to adjust
Exposure Compensation according to current video brightness to achieve
proper brightness value
Exposure Time
Available when
Auto Exposure
is unchecked. Slide to left or right to
decrease or increase exposure time to adjust the video brightness
Gain Adjust Gain to decrease or increase the video brightness. The noise will
be reduced or increased accordingly
Red Slide to left or right to decrease or increase the proportion of Red in
video window
Green Green
is a base for reference and cannot be adjusted
Blue
Slide to left or right to decrease or increase the proportion of
Blue
for
the video
White Balance
Auto
White Balance
adjustment according to the window video
Sharpeness
Adjust
Sharpness
level of the video window
Denoise
Adjust
Denoise
level of the video window
Saturation
Adjust
Saturation
level of the video window
Gamma
Adjust
Gamma
level of the video. Slide to the right side to increase
gamma and to the left to decrease gamma
Contrast
Adjust
Contrast
level of the video. Slide to the right side to increase
contrast and to the left to decrease contrast
DC For DC illumination, there will be no fluctuation in light source so no
need for compensating light flickering
AC(50HZ) Check AC(50HZ) to eliminate flickering “strap”
caused by 50Hz
illumination
AC(60HZ)
Check
AC(60HZ)
to eliminate flickering “strap” caused by 60Hz
illumination
Default Set all the settings in the Camera Control Panel to the default values
The Camera Control Panel controls the camera to achieve the best image quality according to the specific
applications; It will pop up automatically when the mouse cursor is moved to the left side of the video window (in
measurement status, the Camera Control Panel will not pop up. Only when measurement process is terminated will
the Camera Control Panel pop up by moving mouse cursor to the left side of the video window). Left-clicking
button to achieve Display/ Auto Hide switch of the Camera Control Panel;

KITOCAM Auto Focus HDMI C-mount CMOS Camera
14 / 19
3.3.2 Icons and Functions of the Synthesis Camera Control Toolbar at the Bottom
of the Video Window
Icon
Function
Icon
Function
Zoom In
the Video Window
Zoom Out
the Video Window
Horizontal Flip Vertical Flip
Video Freeze Display Cross Line
WDR Start Auto Focus Control Panel
Browse Images and Videos in the SD Card Settings
Check Version of XCamView
The Setting function is relatively more complicated than the other functions. Here are more info about it:
Figure 9 Comprehensive Setting of WiFi Settings Page
Channel: WiFi signal Channel. Avoid interference caused by using the same channel. Suggest choosing different
channels for different cameras when several WiFi cameras are running at the same time;
SSID: Name of the WiFi signal. Can be user-defined by using the soft keyboard below;
Password: Password of the WiFi signal. The Password can be user-defined by using the soft keyboard below;
Default: Set Channel, SSID, Password to the default values;
Figure 10 Comprehensive Measurement Settings Page

KITOCAM Auto Focus HDMI C-mount CMOS Camera
15 / 19
Global:Used for setting digits behind the decimal point for measurement results;
Calibration Line Width: Used for defining width of the lines in measurement and calibration;
Color: Used for defining color of the lines in measurement and calibration;
EndPoint Type: Used for defining shape of the endpoints of lines in measurement and
calibration: Null means no endpoints, rectangle means rectangle type of endpoints.
It makes it easier to calibrate;
Point, Angle, Line, Horizontal Line, Vertical Line, Rectangle, Circle, Ellipse, Annulus, Two Circles, Polygon, Curve:
Left-click the besides the measuring patterns mentioned above will unfold the corresponding
attribute settings to set the individual property of the measuring objects.
Figure 11 Comprehensive Measuring Units, Calibration, Magnification Management Settings Page
Name: Names such as 4X, 10X, 20X ,40X , 100X are based on magnification of microscopes. For continuous zoom
microscopes, ensure that the selected magnification coincides with the scale alignment line;
Resolution: Pixels per meter. Devices like microscopes have high resolution value;
Clear All: Clear All the calibrated magnifications and resolutions;
Delete: Click Delete to delete the selected item for specific resolution;
Figure 12 Image Format Setting Page
JPEG:Save captured image in JPEG format into SD card;
TFT:Save captured image in TFT format into SD card. The TFT format saves not only image data but also the
measurement data over the image. The camera control & imaging processing software is capable of opening TFT
file;

KITOCAM Auto Focus HDMI C-mount CMOS Camera
16 / 19
Figure 13 Comprehensive Setting of Video Encode Setting Page
MJPEG:Save recorded videos in MJPEG coded format;
H264:Save recorded videos in H264 coded format;
Figure 14 Comprehensive Setting of SD Card Setting Page
Current File System: The maximum file FAT32 can store is of 4G Bytes; for NTFS it’s 2048G Bytes. Suggest converting
FAT32 file into NTFS format on a PC; Unknown Status: SD card not detected or the file system is not identified;
Figure 15 XFCAM Comprehensive Setting of Language Selection Setting Page
English:Set language of the whole software into English;
Simplified Chinese:Set language of the whole software into Simplified Chinese;
Traditional Chinese:Set language of the whole software into Traditional Chinese;
Korean: Set language of the whole software into Korean;

KITOCAM Auto Focus HDMI C-mount CMOS Camera
17 / 19
Thailand: Set language of the whole software into Thailand;
3.3.3 The Measurement Toolbar on the Upper Side of the Video Window
The Measurement Toolbar will pop up when moving mouse cursor to any place near the upper side of the video
window. Here are the introduction of the various functions on the Measurement Toolbar:
Figure 16 The Measurement Toolbar Button on the Upper Side of the Video window
Icon
Function
Float/ Fix switch of the Measurement Toolbar
Define measuring object in Show up/ Hide mode
Select the desired Measurement Unit
Choose the same
Magnification
as the microscope to ensure accuracy of measurement
result when measurement unit is not in Pixel unite
Object Select
Point
Angle
Arbitrary Line
Parallel
Horizontal Line
Vertical Line
Rectangle
Circle
Ellipse
Annulus
Two Circles and Center Distance

KITOCAM Auto Focus HDMI C-mount CMOS Camera
18 / 19
Arc
Polygon
Curve
Make Calibration to determine the corresponding relation between magnification and
resolution, this will establish the corresponding relationship between measurement unit and
the sensor pixel size. Calibration needs to be done with the help of a micrometer. For detailed
steps of carrying out calibration please refer to software help manual.
Conjugate Correction: Click to do the Conjugate Correction
before doing any
calibration. Then manually adjust the coarse and fine focus knob of microscope to make
sure the video is clear. Make sure the magnification in the software stays in accordance
with microscope magnification, and then select the corresponding Measurement Unit for
doing the measurement.
Export the measurement information to CSV file (*.csv)
Delete All the Measurement Objects
Setting
Exit from Current Measurement Mode
When the measurement ends, left-click on a single measuring object and the Object
Location & Properties Control Bar will show up. The icons on the control bar mean Move
Left, Move Right, Move Up, Move Down, Color Adjustment and Delete.
Note:
1) When user left-clicks Display/Hide button on the Measurement Toolbar, the Measurement Toolbar will be
fixed. In this case the Camera Control Panel will not pop up automatically even if moving mouse cursor to the left side
of the video window. Only when users left click the button on the Measurement Toolbar to exit from the
measurement mode will they be able to doing other operations in the Camera Control Panel, the Auto Focus Control
Panel or the Synthesis Camera Control Toolbar.
2) When a specific measuring object is selected during the measuring process, the Object Location & Attributes
Control Bar will appear for changing the object location and properties of the selected objects.
3) To ensure accuracy of the measurement, please click the Conjugate Correction button to reset the camera
sensor to the standard C-mount position before calibration. The measurements can be started after calibration is
completed and the video is focused.
4) In case calibration is completed but camera sensor is not on the C-mount position, The Conjugate Correction
should be done to reset sensor to the standard C-mount position and the video is focused before measurement is started.

KITOCAM Auto Focus HDMI C-mount CMOS Camera
19 / 19
3.3.4 Auto Focus Control Panel on the Right Side of the Video Window
Auto Focus
With
Auto Focus
button checked, the system will start autofocus according to
status of the specimen till it stays in focus;
Manual Focus With Manual Focus checked, users should reset position of the camera sensor
by using the mouse to scroll up and down till the specimen stays in focus;
One Push AF Click One Push button can carry out autofocus operation for just once;
Conjugate
Correction
Left-click the Conjugate Correction
button can reset the camera sensor to
standard C-mount position. Conjugate Correction allows users to get sensor
position calibrated while ensuring that the camera video window is clear as
well as image seen from eyepiece is clear. Suggest users do Conjugate
Correction when using the camera for the first time to ensure the camera
sensor at the standard C-mount position. This ensures the object plane,
eyepiece image plane and camera adapter image
plane at the standard
position;
Note: 1) When height of the specimen changes, users must make sure the
sensor at the standard C-mount position while adjusting the coarse and fine
focus knob of microscope to focus; 2) Before doing measurement please do
Conjugate Correction
to make sure accuracy of the measurement results
(please refer to Measurement Toolbar> Conjugate Correction...for details).
3.3.5 Focus Region in the Video Window
Figure 17 Focus Region
The Focus Region is used for selecting the region of interest for auto focus operation. When user clicks the
button on the Synthesis Camera Control Toolbar, the Focus Region will show up as well with the Auto Focus Control
Panel. Users can click any part of the video window to reset the focus region for Auto Focus operation.
When users close the Auto Focus Control Panel, the Focus Region will also be closed automatically.
Note: When Auto Focus is working, moving mouse cursor to upper side of the video window does not make the
Measurement Toolbar pop up.
Table of contents