CONTENTS
• 29610 PowerHub 1
• Instruction Sheet
• Hang Tag
GENERAL SPECIFICATIONS
• AC Input: NEMA 5-15P, Nominal 120V AC, 15A, 60Hz. Use with 15A rated, 5-25'
(1.5-7.6 m) long cord
• Maximum Total Power Output: 1875W
• AC Output: 6 × NEMA 5-15R, Nominal 120V AC, 15A, 60Hz, Max. output 1875W
• Surge Protection: 2160 Joules
• GFCI Type: Auto monitor. Auto reset, trip time 0.025 seconds (nominal)
• Overcurrent Protection: 15A
• USB Output (Total Wattage): 42W
• USB-A: 1× 12W (5V DC, 2.4A) or 2 × 6W (5V DC, 1.2A)
• USB-C: 2× 15W max (5V DC, 3.0A max)
• LED Work Light Output: 5,000 Lumens
• Rotational Range of Work Light: +75°, -15° from horizontal
• Operating Temperature: 14°F to 122°F (-10°C to 50°C)
• Storage Temperature: -4°F to 158°F (-20°C to 70°C)
• Operating / Storage Maximum Altitude: 2,000 m (6,562')
• Operating / Storage Maximum Humidity: 85% non-condensing
• Dimensions: 14" × 14" × 25" (35.6 cm × 35.6 cm × 63.5 cm)
• Weight: 15.1 lb (6.9kg)
• Device Shelf Max Capacity: 5 lbs (2.3kg)
• Drop Protection: 3.3' (1m)
• Standards: CONFORMS TO UL STD, 1363, 1449, 153,
CERTIFIED TO CSA STD, C22.2#308:2018, C22.2#269.3:2017,
C22.2#250.4:2020
WARNINGS
Read, understand, and follow these instructions to ensure safe
operation and service of the PowerHub 1.
Failure to observe these warnings can result in re, electric shock,
property damage, serious injury and/or death.
• TO REDUCE THE RISK OF ELECTRIC SHOCK, USE ONLY INDOORS. DO
NOT EXPOSE TO RAIN OR SNOW.
• R
ISK OF ELECTRIC SHOCK. DO NOT PLUG INTO ANOTHER
RELOCATABLE POWER TAP. PLUG INTO ONLY ONE 15A RATED
EXETNSION CORD, 5-25' (1.5-7.6m) IN LENGTH
• DO NOT
exceed maximum power rating of device (1875W).
• DO NOT
use the product if damaged or modified.
• DO NOT
connect to an ungrounded outlet.
• DO NOT
use with extension cord adapters that eliminate the
connection to ground.
• DO NOT
use near flammable liquids or gases.
• Avoid touching or placing any objects on hot surfaces near LED work
light or its housing.
• DO NOT
attempt to insert other USB connector types into the USB-C
or USB-A ports.
• DO NOT look directly into the LED work light.
• Keep away from high voltage devices.
• CAUTION - DO NOT install this device if there is not at least 10
meters (33') or more of wire between the electrical outlet and the
electrical service panel.
• This device features an internal protection that will disconnect the
surge protective component at the end of its useful life, but will
maintain power to the load – now unprotected.
SYMBOLS ON PRODUCT
Warning or Caution
Risk of Electrical Shock
Read Instructions
Level VI Efficiency Standard
FEATURE DETAILS (FIG.A)
1. Work Light
2. Work Light ON/OFF Button
3. Work Light Tightening Knob
4. Top Grab Handle
5. Side Grab Handle (×2)
6. Integrated Cord Wrap (×2)
7.
Extension Cord Plug Hook (×2)
8. AC Outlet (×6)
9.
USB Ports
10.
AC Input
11.
GFCI Test/Reset Button
12.
GFCI Indicator LED
NOTE: GFCI Indicator LED will illuminate
RED to indicate
power is on.
13.
Device Shelves (×3)
14.
120V Outlet ON/OFF Switch
15.
Surge Protected LED Status Indicator
16.
Grounded Input LED Indicator
MAINTENANCE
CLEANING:
Be sure device is disconnected from all power sources and
devices. Use clean, dry, soft, lint-free cloth to wipe down the entire unit.
Do not use abrasive cleaners or solvents.
STORAGE:
Store at temperatures between -4°F and 158°F (-20°C and
70°C), less than 85% relative humidity, and away from direct sunlight
(See GENERAL SPECIFICATIONS). Leaving in a vehicle or other confined
spaces in extreme hot temperatures can lead to decrease in service
life, overheating, or fire. Extreme cold temperatures below the specified
storage range can also harm performance and service life. Keep away
from corrosive chemicals and gases. After taking out of storage, inspect
visually to make sure device and all accessories look satisfactory. Allow
unit to return to ambient conditions before using.
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash or in
curbside recycle bin. Items must be properly recycled of in
accordance with local regulations. Please see
for additional information.
OPERATING INSTRUCTIONS
PLEASE SEE REVERSE SIDE.
PowerHub 1 -
Instructions
PowerHub 1 - Instrucciones
PowerHub 1 – Instructions
29610
ENGLISH
10
6
2
3
813
5
FIG. A
FRONT / FRENTE / AVANT
9
12
11 14
4
1
8
15
3
716
13
1390488 Rev 02/22 A
www. .com information@itm.com1.800.561.8187
OPERATING INSTRUCTIONS
POWERING AND SETTING UP THE POWERHUB 1:
• Place unit on firm, level ground. Plug a powered, 15A rated , 5-25' long
(1.5-7.6 m), 120V AC power cord into PowerHub 1’s AC Input
10
to
supply power to the unit. When powered, the Surge Protection LED
Indicator
15
will illuminate to show that the outputs are protected from
input voltage surges, and the Ground LED Indicator
16
will illuminate if
the input AC source is grounded. When PowerHub 1 is supplied power,
the USB circuit will be activated automatically.
• Ensure connected power cords do not create trip hazard.
• Refer to your equipment user manual(s) to ensure combined,
connected load is less than 1875W total.
OPERATING THE POWERHUB 1:
• Once powered, turn the power distribution circuit on by toggling
the 120V Outlet ON/OFF Switch
14
to the ON position. This switch
provides power to the 6 × 120V outlets and illuminates when in the
ON position.
NOTE: If the switch
14
is in the ON position and illuminated, but
the 120V outlets are not providing power, refer to the Resetting and
Testing Section
• Once powered, the LED Work Light is activated with the Work Light
ON/OFF Button
2
.
RESETTING AND TESTING THE GFCI AND OVERCURRENT PROTECTION
• If triggered by a ground fault, the built-in GFCI unit will deactivate
power out of the PowerHub 1’s 120V outlets. To reactivate power
to the PowerHub 1, remove the faulty device from the PowerHub
1’s circuit, then press the GFCI Reset Button
11
to re-energize the
PowerHub 1’s outlets.
• GFCI functionality can be tested by pressing the TEST button
11
to
disconnect output power from the device and the RESET button
11
to re-establish output power.
• If the GFCI LED Indicator
12
is illuminated, but the 120V Outlet ON/
OFF Switch
14
is in the ON position and not illuminated, remove
all connected devices and toggle the 120V Outlet ON/OFF Switch to
reset the PowerHub 1’s overcurrent protection.
USING THE INTEGRATED POWER CORD WRAP
• While they are not in use, power cords can be stored on the PowerHub 1
by inserting one plug into a plug hook
7
and looping the cord around
the Integrated Cord Wrap
6
.
USING THE PORTABLE DEVICE SHELVES
• The portable device shelves are intended to elevate small electronics
off the ground while charging. Before resting your portable devices
in the shelves, please ensure that it does not exceed the maximum
weight rating for each self. Once positioned, ensure the portable
device is not at risk of falling off support arm, particularly if bumped.
COMPLIANCE
This device complies with part 15 of the FCC RULES and Industry Canada
license-exempt RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that
may cause undesired operation.
NOTE: The grantee is not responsible for any changes or modifications not
expressly approved by the party responsible for compliance. Such
modifications could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
Canada ICES-003 (B) / NMB-003 (B)
ICES-005 (B) / NMB-005 (B)
ENGLISH
10
6
2
3
8
13
5
FIG. A
FRONT / FRENTE / AVANT
9
12
11 14
4
1
8
15
3
716
13
www. .com information@itm.com1.800.561.8187

This manual suits for next models

1

Popular Work Light manuals by other brands

Prilux Gaudium Assembly instructions

Prilux

Prilux Gaudium Assembly instructions

Energetic Lighting MPL1005-LED15K840 Installation instructions manual

Energetic Lighting

Energetic Lighting MPL1005-LED15K840 Installation instructions manual

Sealey LED0121B manual

Sealey

Sealey LED0121B manual

Black & Decker FireStorm FS18AL instruction manual

Black & Decker

Black & Decker FireStorm FS18AL instruction manual

Polarlite 1559289 operating instructions

Polarlite

Polarlite 1559289 operating instructions

LEXMAN NXW-2109 Use and maintenance manual

LEXMAN

LEXMAN NXW-2109 Use and maintenance manual

LEAD energy SCL Series operating manual

LEAD energy

LEAD energy SCL Series operating manual

Moree LED Pro 45 instruction manual

Moree

Moree LED Pro 45 instruction manual

Napa CARLYLE TOOLS CL800 owner's manual

Napa

Napa CARLYLE TOOLS CL800 owner's manual

EBOY TECHNOLOGY EBE-BAW516 quick start guide

EBOY TECHNOLOGY

EBOY TECHNOLOGY EBE-BAW516 quick start guide

ESYLUX AOL 100 LED Installation and operating instructions

ESYLUX

ESYLUX AOL 100 LED Installation and operating instructions

DeWalt DCL070T1 manual

DeWalt

DeWalt DCL070T1 manual

BOSS ILLUMINATION NOD product manual

BOSS ILLUMINATION

BOSS ILLUMINATION NOD product manual

Parkside PATC 2 A1 Operation and safety notes

Parkside

Parkside PATC 2 A1 Operation and safety notes

Eaton Metalux 14SP4240RT instruction manual

Eaton

Eaton Metalux 14SP4240RT instruction manual

NightSearcher HazStar user manual

NightSearcher

NightSearcher HazStar user manual

Ikan SB200BD quick start guide

Ikan

Ikan SB200BD quick start guide

Atex TL10-090AM K Series installation manual

Atex

Atex TL10-090AM K Series installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.