3.4.2 Move the cursor and selecting ‘Save MT’ will generate a .bin ormat ile.
3.4.3 Move the cursor and select ‘Save OCR’ will generate a ile or OCR processing purpose.
4. Detections
This counter incorporates various detections including UV(ultraviolet), MG(magnetic), MT(magnetic
thread), Re lected IR mapping, and Penetrating IR mapping.
5. Maintenance and troubleshooting
A ter start, the machine will go on sel -check automatically. I preset window show the ollowing error
code, generally speaking, it is because o dust on the sur ace or sensor blocked by notes. So please clear
the dust on the sur ace o sensor with brush or so t cloth, or take the notes away. Then restart the
machine.
Error code Trouble position
E1
Bill UV sensor error
E2
Bill double error
E3
Chain notes error
E4
Hal notes error
E10
Bill CIS sensor signal lose
E11
Denomination error
E12
Bill denomination error
E13
Bill acing recognize error
E14
Bill size recognize error
E15
Bill towards recognize error
E20
MT error
E21
MG1 error
E22
MG2 error
E23
MG3 error
E24
MG4 error
E30
IR transmission area1 error
E31
IR transmission area2 error
E32
IR transmission area3 error
E33
IR transmission area4 error
E34 IR transmission area5 error
E35 IR transmission area6 error
E36 IR transmission area7 error
E37 IR transmission area8 error
E38 IR re lect area 1 error
E39 IR re lect area 2 error