MEI Economy Series User manual

25778 G5 143936044
The 540
ECONOMY SERIES
CHANGEGIVER
POCKET GUIDE
ROUTINE MAINTENANCE,
SAFETY, INSTALLATION &
TROUBLESHOOTING
CashFlow®CashFlow®CashFlow®C
ashFlow®CashFlow®CashFlow®Cas
hFlow®CashFlow®CashFlow®Cash
Flow®CashFlow®CashFlow®CashFl
ow®CashFlow®CashFlow®CashFlo
w®CashFlow®CashFlow®CashFlow
®CashFlow®CashFlow®CashFlow®
CashFlow®CashFlow®CashFlow®C
ashFlow®CashFlow®CashFlow®Cas
hFlow®CashFlow®CashFlow®Cash
Flow®CashFlow®CashFlow®CashFl
ow®CashFlow®CashFlow®CashFlo
w®CashFlow®CashFlow®CashFlow
®CashFlow®CashFlow®CashFlow®
CashFlow®CashFlow®CashFlow®C
ashFlow®CashFlow®CashFlow®Cas
hFlow®CashFlow®CashFlow®Cash
Flow®CashFlow®CashFlow®CashFl
ow®CashFlow®CashFlow®CashFlo
w®CashFlow®CashFlow®CashFlow
®

CashFlow®540 changegiver Pocket Guide
ii ,MEI., 1997
Published by :
MEI
Internet: http://www.meigroup.com
For information on translations in your country, please write to the
Technical Communications Manager at the above address.
CashFlow®540 changegiver Pocket Guide
©, MEI UK International Ltd., 1997. All rights reserved.
Except as permitted under the relevant local legislation, no part of this
publication may be copied, transmitted, transcribed, or distributed in any
form or by any means, or stored in a database or retrieval system, or
translated into any language (natural or computer), without the prior written
permission of MEI.
MEI®, CashFlow®and the MEI device are registered trademarks.
©, MEI., 1997.
MEI reserves the right to change the product or the product specifications
at any time. While every effort has been made to ensure that the
information in this publication is accurate, MEI disclaims any liability
for any direct or indirect losses (howsoever caused) arising out of
use or reliance on this information.
This document does not necessarily imply product availability.
Part Number : 143936044
This Edition ( December 1997 )

CashFlow®540 changegiver Pocket Guide
,MEI., 1997
iii
CONTENTS
Routine Maintenance
Replacing a Fuse
Using the Keypad
Troubleshooting the CashFlow540
Setting a Unit’s Functions with the
MEIRoute Alpha 250 Terminal
Address Settings for the
MEI
Route Alpha 250 Terminal
Coin, Tube and Designator Options
Installing, Starting and Testing a Unit
Product Manuals and
Product Technical Training
Addresses of Regional Offices

CashFlow®540 changegiver Pocket Guide
iv ,MEI., 1997

,MEI., 1997 1
CashFlow®540 changegiver Pocket Guide
User Safety Notices
WARNING
Before cleaning, servicing, removing or replacing
CashFlow®units, ALWAYS SWITCH OFF or
ISOLATE the ELECTRICITY SUPPLY to the host
machine.
CAUTION
This guide is for use only by personnel trained to
carry out electrical installation.
Maximum Operating Voltage
Do not apply more than the voltage specified on the
unit.
Dangerous Environments
Do not operate the unit in the presence of
flammable gases or fumes, or after the entry of fluid
into the machine.
Disposal of Product
If necessary, always dispose of defective units
according to local regulations.
Conformanceto
International Standards
When installed and operated according to the
instructions provided for the particular unit,
CashFlow®products meet the applicable
international and national Safety and Electro
Mechanical Conformance standards for any country
in which they are used.

CashFlow®540 changegiver Pocket Guide
2,MEI., 1997
Parked dispenser arms show here
Reject lever
Coin flap for manual filling
Exit for rejected coins
Keypad and LEDs
Coin entry cup
Acceptor module
Acceptor opening tab
Labels showing the
coin tube positions
Coin storage cassette
release catches
Coin storage cassette
Movable float indicator
Labelshowingkeypadfunctions
and operating voltage of unit
Hinge pin of acceptor
and separator assembly
Connection port for the
Route Alpha 250 terminal
CashFlow540 changegiver
Model number and
serial number of unit
Exit at rear for cashbox coins
Coin slots for manual filling
Interface loom Acceptor and separator
assembly release clip
Mounting screw access flap
Dispenser base

,MEI, 1997 3
CashFlow®540 changegiver Pocket Guide
Routine Maintenance
WARNING
Switch off the power to the host
machine before cleaning the unit
Clean the coin pathway (shown shaded in the
figure) regularly with a soft cloth moistened with
water. Take care that all the surfaces are dry before
you close the lid of the unit, particularly if you have
had to clean the unit after the entry of dirt or fluid.
Take care that no drops of water enter the unit
during cleaning.
Never use solvents or abrasive creams to clean the
unit. These will damage the surfaces. Ensure that
the lid is fully closed after cleaning.
NOTE: If you switch the machine on when
the lid of the acceptor unit is not fully closed,
coins will be rejected, even if you then close
the lid.
If this happens, switch off the power to the
machine for at least 15 seconds,then close the
lid again. Make sure the lid snaps shut.
Switch the power on. Check that coins are
accepted.
Clean the
shaded areas
Lid
Opening
tab

CashFlow®540 changegiver Pocket Guide
4 ,MEI., 1997
Cleaning the Dispenser Arms
Switch off the power to the host
machine before cleaning the unit
Squeeze together the two release catches of the
coin storage cassette and lift out the cassette.
Clean the dispenser arms and their paths in the
dispenser base with a soft cloth moistened with
water.
Switch on power to the machine, press the yellow
Mode button twice to park the dispenser arms, and
replace the coin cassette.
Check that the two release catches snap shut.
You should only remove the dispenser and the
dispenser arms for cleaning if there is a heavy build
up of dirt or other matter in the dispenser.
Always refer to the Product Maintenance
Handbook before removing these parts.
Dispenser arms in
parked position
Clean the arms
and their paths

,MEI., 1997 5
CashFlow®540 changegiver Pocket Guide
Checking and Replacing a Fuse
Switch off the power to the host
machine before checking a fuse
Squeeze together the two release catches of the
coin storage cassette and lift out the cassette.
Press down the blue release catch above the
creditor with a small screwdriver. Pull the top of the
creditor forward and downwards. Unplug the
exposed ribbon cable and lift out the creditor.
The fuses are under a cover in the left hand side of
the unit.
Always replace a blown fuse with one of the same
rating.
Replace the creditor, reconnect the ribbon cable
and press the creditor into place.
Park the dispenser arms and replace the coin
cassette.
Make sure that the release catches of the
creditor and of the cassette snap shut firmly.
Switch on power to the machine. Check that the red
LED comes on.
Acceptor
release catch
Coin cassette
release catches
Fuse box cover
is located
behind creditor

CashFlow®540 changegiver Pocket Guide
6,MEI., 1997
Using the Keypad
Use the keypad to park the dispenser arms,
dispense coins, set prices, float the coin tubes up or
down, and to re-set the tube counts to their pre-set
levels.
The keypad label summarises keypad functions.
▲Not applicable with BDV product.
★If an audit FEM is fitted, Mode+A+Bis not
available to reset tubes to pre-set levels.
◆Not applicable with MDB product.
Function Buttons
Dispense coins from tubes ▲
Park the dispenser arms
Float up tubes automatically
Float down tube automatically
Reset tubes to pre-set levels★
Set the vend prices ◆
Cancel the accumulated credit +
+
Red LED
Tube A
dispense Tube B
dispense
Mode button
(YELLOW)
Tube C
dispense
Tube D
dispense
Correct voltage
for unit
No function
Dispense
coins
Float up tube
Set vend
prices
Re-set tubes
automatically
to pre-set level
Yellow LED A B
CD
+
+
A C
+
A
A
C
AA
B
B C D
,or
+
+
+
+
A,▲
◆
★

CashFlow®540 changegiver Pocket Guide
,MEI., 1997 7
Using the Keypad
Dispense Coins / Empty Tubes
Press a button once to dispense a coin from a
corresponding tube. If you press and hold for more
than three seconds, coins are dispensed
automatically until only a sufficient minimum (the
safe count) are left to operate the dispense
mechanism. To empty a tube or a cassette, you
may have to take out the last coins by hand.
Float-Up Tube Counts Automatically
Press the buttons, then feed tube coins through the
acceptor to refill the tubes to their pre-set float
level. When float levels are reached, further coins
are rejected. If automatic float is left by pressing B,
tube counts re-set to pre-programmed float levels.
Re-set the Tube Counts
Press the buttons to force tube counts to re-set to
pre-set float levels. If there are not enough tube
coins to meet the pre-set levels, coin counts remain
incorrect until recalibration takes place. ★If an
audit FEM is fitted, reset via Mode+A+Bis not
available.
Automatic Float Down to Pre-set Levels
If the unit is programmed for this function,
press the buttons to dispense coins until tube
counts reach their pre-set float levels. If the
numbers of coins already in the tubes are equal to
or below the float levels, no coins are dispensed.
Set the Vend Prices
Press the buttons. Insert coins equal to the lowest
price. Make a selection. A 45-second time-out
starts after each coin. More selections at the same
price can be made without inserting extra coins.
Add coins for the next highest price, and make a
selection. Continue until all prices are set. Press C
to cancel credit and to exit price teach.
◆Not applicable with MDB product.
B C D
,or
A
A
+
,
C
+◆
A B
+
+★
AC
+
+

CashFlow®540 changegiver Pocket Guide
8,MEI., 1997
4 PRICE/1 PRICE MODE SWITCH
(Multi-Interface Product only)
The multi-Interface product offers a mode switch
which, in electro-mechanical operation, allows a 4
price product fitted with a T4 loom to be used in
place of a 1 price product fitted with a T3 loom.
The mode switch is located behind the top flap of the
keypad cover and is of the slide type. If the switch is
to the left the product will be in 4 price mode and if it
is to the right the product will be in the 1 price mode.
1 Price Mode
Position
4 Price Mode
Position
PCB
Slide
Switch
Assy

CashFlow®540 changegiver Pocket Guide
,MEI., 1997 9
FLASHING? OFF?
•Remove cassette, check
for coins covering top-level
sensors
•Check acceptor coin path
•Check for jams in separator
•Press Mode+Mode and
replace the cassette
•Blocker signal from
VMC not present.
•Check for blocker
from VMC to unit.
Is signal present?
•Feedchangecoins
into acceptor
•Are coins routed to
the correct tubes?
•Does the red LED
stop flashing?
•Float up tubes to the
required levels
•Make a trial vend to
check the unit
•Is the unit’s
interface loom
firmly connected?
•Press A,B,C,D
•Are correct coins
dispensed?
Y
N
Y
Y
Y
Y
N
N
N
•Press Mode+Mode
•Does the yellow
LED flash?
•Press A,B,C,Dto
dispense coins
•Insert change coins
•Are change coins
accepted?
•Check fuses,
replace if blown
•Re-connect loom
and re-start unit
N
•Make a trial vend to
check the unit
•Check for sufficient change
coins in tubes, and for jams
in dispenser and tubes
•Remove cassette and press
Mode+Mode to check
dispenser arm movement
•Check reject lever clearance
•Refer to the
troubleshooting
table in this Guide
•Are all coins accepted
and the red LED lit?
Y N
•Make a trial vend
to check the unit
Troubleshooting the CashFlowUnit
N
Is the red LED...
•CheckRouteAlphaaddresses
340 to 349 for error description

CashFlow®540 changegiver Pocket Guide
10 ,MEI., 1997
Problem Causes Actions
No coins accepted Blocked accept gate opto’s, or build
up of dirt in the unit
Power loom not inserted correctly
Switch off power to machine, check if the opto’s are blocked,
and clean the unit. Refer to the Product Maintenance
Handbook’s cleaning section before cleaning the opto’s.
Switch off power to the machine, and check the loom.
Poor coin acceptance Changegiver unit is not level
Modules are not mounted and
aligned correctly
Build-up of dirt in the acceptor
Check and re-level the unit if necessary.
Check that the coin entry and exit chutes of the machine are
aligned with the coin entry cup on the unit and the cashbox on
the machine.
Adjust the modules until they are aligned accurately.
Switch off power to machine, check and clean acceptor.
Coins are accepted but no
credit is given Power loom is not inserted correctly
Coin jam in the separator module
(post gate strobes are covered)
Accept gate strobes mechanism
blocked or dirty
Switch off power to the machine, and check the loom.
Switch off power to the machine, and check the separator for
jams.
Refer to the Product Maintenance Handbook before
attempting to clean the strobes or the opto’s.
Troubleshooting the CashFlowUnit

CashFlow®540 changegiver Pocket Guide
,MEI., 1997 11
Unit rejects one type of
coin or token
N.B.
With MDB applications the coin
mechanism is controlled by the
vending machine controller.
Coin or token is inhibited
Coin or token is damaged or worn
A tube has reached pre-set float
level, further coins are rejected
because the unit is in float mode
Check the coin/token is in the coin set, and has been enabled.
Use the Route Alpha 250 terminal to enable the coin
Discard the worn or damaged coin/token.
Press Ato leave float mode and to clear any credit.
Check the tube levels, then make a vend to check that the
correct change is dispensed.
Coins are not routing
correctly The level of coins in a tube is
covering a top-level sensor
The top-level sensor loom or the
separator loom is not connected
correctly
Wrong acceptor or separator is fitted
A tube is disabled
Check tube counts. If they are above the pre-set float levels
and automatic tube inventory is set, press Mode+A+C to
float-down the coins in the tubes.
Switch off the power, remove the cassette and release the
acceptor. Check that the top-level sensor and separator looms
are fitted correctly. Replace the acceptor and cassette. Switch
on power to the unit, insert coins and check routing.
Check that the acceptor and separator are the correct versions.
Refer to your authorised MEI distributor.
Use the Route Alpha 250 terminal to enable the tube.
Problem Causes Actions

CashFlow®540 changegiver Pocket Guide
12 ,MEI., 1997
High-value coins are
rejected and exact change
light is ON
Too few coins in the change tubes,
leaving the low-level sensors
uncovered
Unit is in No overpay mode. N.B.
Does not apply to MDB applications
Re-float the coin tubes through the acceptor until the low-level
sensor mirrors are covered.
Check Route Alpha 250 address 242.
Incorrect change is
dispensed Insufficient change coins are
available
Incorrect coin values are set.
Incorrect prices are set for required
selections. N.B. Price control is
held in the vending machine in MDB
applications, and are normally held
in the vending machine in Executive
and BDV applications.
If required, float up through acceptor with correct change coins.
Check coin values and prices, reset if necessary using the
Route Alpha 250 terminal. Press A, B,Cand Dto check if
change coins are dispensed.
Check that coins are being routed to the tubes correctly.
Problem Causes Actions

CashFlow®540 changegiver Pocket Guide
,MEI., 1997 13
No coins are dispensed Levels of coins in the tubes are
below the safe count
Dispenser loom not connected, or
loose
Faulty dispenser module
Check that change coins are available in the tubes.
If necessary, float up the tubes with the correct change coins.
Switch off power to the machine and check that the
dispenser loom is fitted correctly. Refer to the Product
Maintenance Handbook.
Check that the dispenser module is operating correctly. Refer to
Maintenance Handbook’s module replacement section
before you attempt to service or to replace the dispenser.
Red LED is ON, except
when a vend is made Normal operation No action
Red LED is ON but coins
are not accepted Coin jam in the changer mechanism
Lid of the acceptor is open
Not enough reject lever clearance
Check for jams in the acceptor and in the tubes. Clear the jams.
Press Mode+Mode to park the dispenser arms before
replacing the cassette, then dispense a coin from each tube to
check operation.
Switch off the power to the machine. Open and close the lid
of the acceptor, wait at least 15 seconds, then switch on
again.
Check clearance is between 2 - 3mm, and adjust if necessary.
Problem Causes Actions

CashFlow®540 changegiver Pocket Guide
14 ,MEI., 1997
Red LED stays OFF No power to the unit, or voltage not
correct
No power to the unit - loose loom or
blown fuse
Check that the power supply to the changegiver is at the
voltage shown in the window on the keypad label.
Test the power supply by pressing the Mode button.
If the yellow LED flashes, the power is ON.
If yellow LED stays off, switch off power to the machine, and
check all power looms and fuses.
Replace any blown fuses.
Restart the machine and check that the red LED is on.
Problem Causes Actions

CashFlow®540 changegiver Pocket Guide
,MEI., 1997 15
Red LED is FLASHING Fault with the changegiver unit
A coin has covered the top-level
sensor mirrors
A coin is jammed in the dispenser
module
Fault with the audit module
Coin cassette is unclipped
Check Route Alpha 250 addresses 340 - 349. Press A,B,C&
Dto check if coins are dispensed. If the red LED is still flashing,
switch off the power to the machine, wait at least 15
seconds and switch on again. Check that coins are dispensed.
Remove the coin cassette and check the tops of the coin tubes.
Switch off the power to the machine, remove the cassette
and check the dispenser for jams.
Clear any blockages and check for damaged coins.
Check the Route Alpha 250 audit addresses.
Return the unit to your MEI distributor for repair if necessary.
Press coin cassette into place firmly, ensure clips snap shut.
Problem Causes Actions

CashFlow®540 changegiver Pocket Guide
16 ,MEI., 1997
Red LED stays OFF and all
coins are rejected No stock available for vending
No blocker signal from the machine
No polling by VNC - MDB only
Faulty transformer
Restock machine if necessary.
Check for a full waste bucket. Check if machine is paused
halfway through a vend cycle. Complete the cycle if necessary.
Check the transformer. If faulty, refer to your MEI distributor.
Red LED permanently
OFF. No other problems. Faulty LED or keypad module Check the keypad module.
If it is faulty, refer to your authorised MEI distributor.
Red LED is flashing and no
coins are accepted Check Route Alpha addresses 340
to 349 for a description of the error
The lid of the acceptor is not closed
firmly
The acceptor loom is not connected
The coin path in the acceptor is dirty
Use the table of Route Alpha 250 error addresses in this
manual
Switch off power to the machine and open and close the lid
of the unit. Make sure the lid snaps shut firmly. Wait at least
15 seconds and switch the power on again.
Check the acceptor loom and reconnect it if necessary.
Switch off power to the machine and clean the acceptor.
Yellow LED is OFF Normal operation No action
Problem Causes Actions
This manual suits for next models
1
Table of contents
Other MEI Cash Counter & Coin Sorter manuals

MEI
MEI CASHFLOW 7000 Series User guide

MEI
MEI CASHFLOW 7000 Series User guide

MEI
MEI CashFlow REFERENCE Series User manual

MEI
MEI EC6000 Manual

MEI
MEI Cashflow 690 series Reference guide

MEI
MEI Cashflow 690 series Reference guide

MEI
MEI Cashflow 9500 User manual

MEI
MEI CASHFLOW 952 Series User manual

MEI
MEI TRC Series User manual

MEI
MEI cashflow VN2700R User manual