Kohler Mira Sport J03In User manual

11561659-W2-A
Mira Sport Thermostatic
9.0 and 9.8 kW
For SPARES,
ADVICE or REPAIRS
please call us free
on 0800 001 4040
(UK only)
For Safety!
Before installing
or using this shower,
you MUST read this
guide.
These instructions must be left with the user
Installation and User Guide

21561659-W2-A
Warning! This shower can deliver scalding temperatures, cause
re, electric shock or other personal injury if not operated, or
maintained in accordance with the instructions, warnings and
cautions contained in this guide and on the appliance.
Pleasereadtheimportantsafetyinformationandtheoperationsection
of this guide before using the shower. Failure to follow the information
or instructions provided on or with this shower will invalidate the
guarantee.
Warning! The shower head and hose supplied with this product
are critical to its correct operation. When installing or exchanging
an electric shower always t and use the shower head and hose
provided with the product.
If any future change of the shower head or hose is required only t
suitableMiramanufactured products. Non-Mira manufactured shower
heads may not be suitable for electric showers. They can be very
restrictive or stop the ow of water, this is dangerous and could lead
to product damage, scalding or serious injury.
If you are unsure about the shower head and hose compatibility with
your shower contact Mira Customer Services.
TOREDUCETHERISKOFFIRE,ELECTRICSHOCKORINJURY:
1. Childrenyounger than 3 yearsshouldnotusethis shower. Children
3 years to under 8 years should only use this shower under
continuous supervision. Children aged 8 years and above and
persons with reduced physical, sensory, or mental capabilities or
lack of experience or knowledge can use the shower if they are
given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved.
2. Children shall not be allowed to play with the shower.
3. Cleaning and user maintenance shall not be made by children.
Important Safety Information

31561659-W2-A
4. DO NOT restrict the water ow from the shower outlet, temporarily
bending the shower hose or blocking the shower head, such as
placing against your body while in use can cause a very hot shot
of water to be discharged.
5. The outlet must not be connected to any tap or tting other than
those specied.
6. The showerhead must be descaled regularly.Any blockage of the
showerhead or hose can cause injury or scalding.
7. Warning! DO NOT switch on if there is a possibility that the water
in the shower is frozen.
8. Warning! If the shower has symptoms of low or no ow from the
outlet, immediately turn it o and DO NOT operate the shower.
Any further diagnosis must be carried out with the power control
set to low and the temperature control set to full cold.
9. Thisshowermustbeprovidedwithmeansforlocaldisconnectionthat
is incorporated into the xed wiring in accordance with the relevant
local wiring regulations. This must be a double pole switch, which
has at least 3 mm contact separation in each pole. The switch can
be a ceiling mounted pull-cord type within the shower room or a wall
mounted switch tted in the applicable zone area.
10. Installation of the shower must be carried out in accordance with
these instructions by qualied, competent personnel. Read all
instructions before installing the shower.
11. DO NOT switch the shower on if water starts leaking from the
showercase.Isolatetheelectricalsupplytotheshowerimmediately.
12. DO NOT switch the shower on if the case appears to be damaged
or incorrectly tted. Isolate the electrical supply to the shower
immediately.
13. DO NOT increase the power setting or adjust the temperature
controlrapidlywhileusing the shower. Move away from the shower
and ensure the temperature has stabilised before re-entering the
shower.

41561659-W2-A
14. DO NOT switch the shower o and back on while standing in the
water ow. Move away from the shower and ensure the temperature
has stabilised before re-entering the shower.
15. DO NOT change the handset model. Fit only shower heads
recommended by Mira and do no t any additional device to restrict
the water outlet ow.
16. When adjusting the handset mode, point handset away from body
and make sure that the water temperature has stabilised before
continuing to shower.
17. Use caution when altering the water temperature, always check
the temperature before continuing to shower.
18. For Dual Head Products in low ambient room temperatures. DO
NOT turn up the temperature control too high as the product may
cycle Hot/Cold.
19. Switch the shower o at the electrical isolating switch when not in
use. This is recommended with all electrical appliances.
20. Isolate the electrical and water supplies before commencing
installation. The electricity must be isolated at the consumer unit
and the appropriate circuit fuse removed, if applicable. Mains
connections are exposed when the cover is removed.
21. DO NOT install the shower in areas with high humidity and
temperature (i.e. Steam rooms and saunas).
22. DO NOT install the shower where it may be exposed to freezing
conditions. Ensure that any pipework that could become frozen is
properly insulated.
23. DO NOT connect the outlet of the shower to any tap, control valve,
trigger operated handset or showerhead other than those specied
for use with this shower as the outlet acts as a vent for the tank
body.OnlyKohlerMirarecommended accessories shouldbeused.
24. DO NOT perform any unspecied modications, or drill or cut holes
in the product other than instructed by this guide. When servicing
only use genuine Kohler Mira replacement parts.

51561659-W2-A
25. DO NOT connect this shower to a Waste Water Heat Recovery
System as this may cause unstable or scalding temperatures to
be delivered from the shower head.
26. Always check the water temperature is safe before entering the
shower.
27. The water supply to this product must be isolated if the product is
not to be used for a long period of time. If the product or pipework
is at risk of freezing during this period they should also be drained
of water.
28. If the shower is dismantled during installation or servicing then,
upon completion, an inspection must be made to ensure all
electrical connections are tight and that there are no leaks.
29. This appliance is intended to be permanently connected to the
water mains and not connected by a hose set.
30. The water inlet of this appliance shall not be connected to a water
supply obtained from any other water heating system.
31. Warning! This appliance is not to be used to provide a potable
water supply.
If you are unsure about any of these Warnings & Cautions and require
further explanation contact Mira Customer Services.

61561659-W2-A
Pack Contents
Tick the appropriate boxes to familiarize yourself with the part names and to conrm
that the parts are included.
Wiring Diagram
Internal Wiring Diagram
1 x Mira Sport Thermostatic
Electric Shower
3 x Wall Plugs
1 x Compression Nut
3 x Fixing Screws
1 x Olive
2 x Case Inserts
INLET
CONNECTOR
TERMINAL
BLOCK
HEATER
TANK
MICRO
SWITCH
(L)
MICRO
SWITCH
(R)
SOLENOID
LED/LED
HOUSING
PUSH BUTTON
SWITCH
BROWN B
GREEN D
BLUE C
RED K
BROWN J
BROWN G
BLACK M
BLACK L
RED H
BLUE E
BROWN F
BLUE E
BLACK N
GREEN A GREEN A
GREEN D
Documentation
1 x Quick Start Guide
1 x Warnings and Cautions Guide
1 x Energy Label 1 x Guarantee Brochure

71561659-W2-A
Domestic Light Commercial
Heavy Commercial Healthcare
Design Registration: 001259287-0002, 001259287-0005
Patents: GB: 2 427 460, 2 404 000, 2 428 286
Thank you for purchasing a quality Mira Sport Thermostatic Electric Shower. To enjoy
the full potential of your new shower, please take time to read this guide thoroughly,
and keep it handy for future reference.
Products manufactured by Kohler Mira Ltd are designed to be safe provided, that
they are installed used and maintained in good working order, in accordance with
our instructions and recommendations.
Follow all warnings, cautions and instructions contained in this guide, and on or
inside the shower.
Mira Sport Thermostatic electric showers have separate controls for power
selection and for temperature/ow adjustment. A unique ow regulator stabilises
any temperature changes caused by water pressure uctuations, which can result
from taps being turned on or o or toilets being ushed.
Product Variant Model No. Colour
Mira Sport Thermostatic 9.0 kW J03In White/Chrome
Mira Sport Thermostatic 9.8 kW J03Jn White/Chrome
Introduction
Products Covered
Recommended Usage
Patents and Design Registration

81561659-W2-A
Specications
Plumbing Thermostatic Variant
Sport 9.0 Sport 9.8
Minimum Dynamic Pressure 70 kPa (0.7 bar)
Maximum Dynamic Pressure * 500 kPa (5 bar)
Minimum Static Pressure 20 kPa (0.2 bar)
Maximum Static Pressure * 1000 kPa (10 bar)
Maximum Inlet Temperature 30°C
Minimum Inlet Temperature 2°C
Inlet Connection 1/2" BSP Male / 15 mm Compression Fitting
Maximum Water Hardness 200 ppm CaCO3
Outlet Connection 1/2" BSP Male
Electrical Thermostatic Variant
Sport 9.0 Sport 9.8
Nominal Power at 230 V ac 8.3 kW 9.0 kW
Nominal Power at 240 V ac 9.0 kW 9.8 kW
Recommended MCB Rating 40 A 45 A
Maximum Supply Cable Size 16 mm²
Recommended RCD Rating 30 mA tripping current
Recommended Isolator Switch 45 A double-pole with 3 mm contact separation
Appliance Sealing Rating IP X4
Maximum Ambient Temperature 30°C
Minimum Ambient Temperature 2°C
Dimensions
Height 358 mm
Width 215 mm
Depth 90 mm
*A drop tight pressure reducing valve should be installed where dynamic or static pressure
exceeds the gure stated in the Specications.

91561659-W2-A
For domestic installations, Mira Showers guarantee the Mira product against
any defect in materials or workmanship for a period of two years from the date of
purchase (shower ttings for one year).
Fornon-domestic installations, Mira Showers guarantee the Mira product against
any defect in materials or workmanship for a period of one year from the date of
purchase. For Terms and Conditions refer to the back cover of this guide.
Guarantee
UK & EU Conformity Information
This product is in conformity with the relevant statutory requirements applicable to
the product:
UK Legislation:
• S.I. 2016/1091 Electromagnetic Compatibility Regulations
• S.I. 2016/1101 Electrical Equipment (Safety) Regulations
• S.I. 2012/3032 Restriction of the Use of Certain Hazardous Substances in
Electrical and Electronic Equipment
• S.I. 2010/2617 The Ecodesign for Energy-Related Products and Energy
Information Regulations
EU Legislation:
• 2014/35/EU - Low Voltage Directive (LVD)
• 2014/30/EU - Electromagnetic Compatibility Directive (EMC)
• 2011/65/EU - Restriction of Hazardous Substances Directive (RoHS)
• (EU) No 814/2013 - Ecodesign requirements for water heaters and hot water
storage tanks
This range of electric showers are high power appliances and are subject to
conditional connection. If the main electrical supply fuse is rated less than 80 Amps,
the local electricity supply company must be contacted to conrm if the electrical
supply is adequate.
Thisrange of showerscomplies with therequirements of theUK’swater regulations.

101561659-W2-A
Indicative annual electricity consumption (kWh), based upon 2100 Wh daily water
energy demand. Actual electricity consumption will depend on kW rating and the
duration and frequency of use.
Product Information
Eco-Design/Energy Labelling
Mira
Sport Thermostatic
kW Rating 9.0 kW 9.8 kW
Load Prole XS XS
Eciency Class A A
Eciency (%) 38.8 38.7
Annual Electricity Consumption (kWh) 476 477
Sound Power Level (dB) 15 15
Disposal and Recycling
End of Product Life
Electrical and electronic devices contain a range of materials that can be separated
for recycling and used in new products.
This product should not be disposed of with your general household
waste. When this product has reached the end of its serviceable life,
please remove any batteries and take it to a recognised WEEE (Waste
Electrical and Electronic Equipment) collection facility such as your local
civic amenity site for recycling.
Your local authority or retailer will be able to advise you of your nearest recycling
facility.

11 1561659-W2-A
Installation Requirements
Plumbing
1. Theplumbing installationmust comply withall nationalor localwater regulations
and all relevant building regulations, or any particular regulation or practice
specied by the local water supply company.
2. DO NOT use any other shower ttings. Only install and use the shower hose
and handset provided with this product.
3. DO NOT use sealing compounds on any pipe tting or joints.
4. DO NOT install the product in a position in which service access is limited.
5. Decideon a suitableposition for theshower (minimumdistance of 200mm from
the ceiling to allow for cover t and removal).
6. The position of the shower and shower ttings must provide a minimum gap of
25 mm between the showerhead and the spill over level of any bath, shower
tray or basin and a minimum gap of 30 mm between the showerhead and the
spill over level of any toilet, bidet or other appliance with a Fluid Category 5
backow risk (see diagram on page 11).
7. The shower is suitable for installation within the shower area and is tted with
a pressure relief valve. It must be positioned over a water catchment area with
the controls at a convenient height for the user.
8. The shower must be tted to a waterproof at and even wall surface.
9. DO NOT t the shower to the wall and tile up to the case.
10. DO NOT seal the gap between the shower and the wall surface.
11. The showerhead should be positioned so that it discharges down the centre
line of the bath or across the opening of a shower cubicle.
12. The showerhead must be directed away from the shower unit, during normal
use the showerhead must not spray directly on to the shower unit.
13. DO NOT apply excessive force to plumbing connections; always provide
mechanical support when making plumbing connections. Any soldered joints
should be made before connecting the shower.
14. This shower is not designed to be plumbed directly from the rear. For rear-entry
supply, add an elbow to the supply pipe and connect as a rising or a falling
supply.
15. If pipework and/or electrical cables enter the shower from the rear through a
hole in the wall provision must be made to prevent water ingress back into the
wall structure.
16. Only use the inlet connector supplied with the shower. DO NOT use any other
type of tting.
17. A full bore/non restrictive servicing valve must be tted in a readily accessible
position adjacent to the shower to facilitate maintenance of the shower.

121561659-W2-A
Zone of
Backflow Risk
30 mm
Minimum
Toilet or Bidet
FC5 Hand Basin
FC3
Bath or Shower
Tray FC3
Electric
Shower
25 mm
Minimum
25 mm Minimum
DO NOT use a valve with a loose washer plate (jumper) as this can lead to a
build up of static pressure.
18. A water treatment device should be installed where the water hardness may
exceed 200 ppm. Malfunctions caused by excessive limescale formation are
not covered by this shower’s guarantee (see back page for details).
19. The installation must not cause the hose to be sharply kinked during normal
use.
20. DO NOT performtheelectrical installationuntilthe plumbinghas beencompleted
and checked for leaks.
Hose retaining ring tted and shower ttings xed at a suitable height
preventing dirty water backow
Note: There will be occasions when the hose retaining ring will not provide
a suitable solution for Fluid Category 3 installations, in these instances
an outlet double check valve must be tted, this will increase the required
supply pressure typically by 10kPa (0.1 bar). Double check valves tted in
the inlet supply to the appliance cause a pressure build up, which aect
the maximum static inlet pressure for the appliance and must not be tted.
For Fluid category 5 double check valves are not suitable.

13 1561659-W2-A
Plumbing and Electrical Schematic
Electrical
1. The electrical installation must comply with BS 7671 (commonly referred to as
the IEE Wiring Regulations) and all relevant building regulations, or any particular
regulation or practice specied by the local electricity supply company.
2. Ensure that all circuit protection devices, switches and cabling is adequate
for the rated current of the shower and that the rating of the electricity supply
company fuse and the consumer unit are adequate for the additional demand.
3. The shower must be earthed. Ensure any supplementary bonding complies
with the relevant regulations.
4. This shower is intended to be permanently connected to the xed electrical wiring
of the mains system. A separate supply must be provided from the consumer
unit to the shower.
5. DONOTsupplyany otherelectricalequipment includingextractorfans orpumps
via this product.
6. This shower must be provided with means for local disconnection that is
incorporated into the xed wiring in accordance with the relevant local wiring
regulations.Thismust be a double pole switch, which has at least 3 mm contact
separation in each pole. The switch can be a ceiling mounted pull-cord type
within the shower room or a wall mounted switch tted in the applicable zone
area.
7. A 30mA Residual Current Device (RCD) must be incorporated into the electrical
supply to this shower in accordance with wiring regulations.
8. DO NOT apply excessive force to the terminal block.
9. Allelectricalconnectionsshould bechecked fortightness toprevent overheating
before switching on the electrical supply.
10. DO NOT switch on the electrical supply until the plumbing has been completed
and checked for leaks.
LOW HIGH
ECO
POWER
1
2
3
4
56
7
8
9
10
THERMOSTATIC

141561659-W2-A
Warning! Turn o the electrical and water supplies before proceeding with
the installation of the shower.
Caution!DO NOT drill into
buried cables or pipes.
Remove the three screws that
hold the cover on and remove
the cover.
Remove the service tunnel.
Using the holes in the case, mark
the positions of the three xing
holes.
Note: Ensure that there are
sucient lengths of supply pipe
and electrical cable to reach the
connection points.
Remove the product and drill
three holes to suit the fixing
screws and wall plugs.
Caution! DO NOT drill into
cables or pipes in the wall.
1
3
4
2
Cover
Screws
Screw
6 mm
Service
Tunnel
Installation

15 1561659-W2-A
Rotate the inlet connector to
suit the direction of the incoming
water supply.
Secure the shower to the wall.
Thoroughly ush the supply
pipe.
Determinethedirection androute
of the incoming water supply:
falling (entering the shower from
the top), or rising (entering the
shower from the bottom).
Note: DO NOT use an incoming
supply entering the shower
directly from the back. Add an
elbow to the supply pipe and
connect it as a rising or falling
supply.
Upperand lowercase insertsare
supplied and should be tted.
Note:Trimtheinsertsifnecessary
to t incoming electrical or water
supplies before tting.
9
6
8
5
7
Case
Insert
Case
Insert
Inlet
Connector

161561659-W2-A
LN
Loosenthescrews intheterminal
block and insert the wires.
Inlet
Connector
Olive
Compression
Nut
Inlet Supply
Pipe
Connect the inlet supply pipe
to the inlet connector using
the compression nut and olive
(supplied). Always provide
mechanicalsupportwhenmaking
plumbing connections. Upon
completion of the installation
ensure connections and back
case are not under any stress
due to misaligned pipework or
electrical cables.
Terminal
Block
Outlet
Connector
Cold Water Supply
Pipe / Inlet Connector
Strip back sucient outer cable
insulation to enable routing to
terminal block.
Fit an earth sleeve to the earth
wire.
Tightenthescrews intheterminal
block, ensure the wires are
secure and tight.
Electrical
Cables
N(Neutral) = Blue wire
L(Live) = Brown wire
(Protective Earth) =
Green /Yellow sleeved wire
Turn on the water supply
and check for leaks.
10
11
12
13
14
15

17 1561659-W2-A
Screws
Cover
Spindle
Service Tunnel
Screw
LOW HIGH
ECO
POWER
1
2
3
4
56
7
8
9
10
THERMOSTATIC
Ensure the earth bonding
complies with relevant
regulations.
Replace the service tunnel.
Ensure the control dials are
aligned with the spindles and
replace the cover.
Tighten the three cover screws.
16
17
18
19
20
22
DO NOT use alternative screws
to secure the cover. This can
cause internal damage to the
appliance.
DO NOT seal around the back of
appliance.
21 Install the shower ttings (Refer
tothe ShowerFittingsInstallation
and User Guide on the Mira
website - or linked with a QR
code on the Quick Start Guide).
This completes the installation,
follow the guidelines in section
‘COMMISSIONING’ to prepare
the shower for use.

181561659-W2-A
Commissioning
Note: A slight hissing sound may be heard from
the Mira Escape during operation. High mains
water pressure and high shower temperatures
will aect the tone. This is quite normal in use.
Switch on the electrical supply.Turn temperature control to
the cold position. Turn power control to low.
Push START/STOP button.
Lightinthebuttonilluminates. Water flows freely within a
few seconds, temperature
remains cool.
LOW HIGH
ECO
POWER
13
2
46
5
COLD
0 - 15 secs
HOT
TEMPERATURE
TEMPERATURE
1
2
3
4
56
7
8
9
10
LOW HIGH
ECO
POWER
POWER
Turn power control to Eco.
Temperature will rise
slightly.
7
5 - 10 secs
COLD
HOT
LOW
HIGH
ECO
POWER
POWER
Turn power control to High. Temperature will rise further.
Adjust temperature as
required. Flow rate will adjust
automatically.
Push START/STOP button.
Light in the button goes out.
Switch off the electrical
supply.
The shower will purge water
from its tank for a few seconds..
9
12
13
8
10 11
TEMPERATURE
TEMPERATURE
1
2
3
4
56
7
8
9
10
5 - 10 secs
COLD
HOT
COLD
0 - 5 secs
HOT

19 1561659-W2-A
Read the section “Important Safety Information” rst.
Switch on the electrical supply.
Turn the power control to the desired
position. Adjust temperature as required. See *Important
Information for Dual Head Products.
0
15
COLD
HOT
Allow 10 - 15 secs for any temperature
adjustments to stabilise and reach the
showerhead.
Check the water temperature before
entering shower.
Switch off the electrical supply.
Push the START/STOP button to turn ON
the appliance. Light in the button illuminates.
Push START/STOP button. Light in the button
goes out and shower continues to run for a
few seconds.
Operation
LOW
HIGH
ECO
POWER
POWER
TEMPERATURE
TEMPERATURE
12
34
5 6
78

201561659-W2-A
9
A small amount of water may continue to drain over a few minutes.
Warning! Turning the shower o and back on or adjusting the temperature control
during showering may result in unstable temperatures at the showerhead. Always
ensure the temperature has stabilised before re-using the shower.
DO NOT hold the showerhead against the body. This may cause product damage,
injury or scalding.
DO NOT allow children to use the shower unsupervised or allow them to play with
the shower ttings or controls.
Alwaysmakesure theshowerhose isnotkinked ordamagedand theshowerhandset
is not blocked before using the shower.
Note:A slight hissing sound may be heard from the shower during operation.
High mains water pressure and high shower temperatures will affect the
tone. This is quite normal in use.
* Important! For Dual Head Products.
Usingtheoverheadshowerduringwintermonthsmayrequirethedesiredoutlet
temperature tobe increased.Coolerroom temperaturescould causethisto be
increasedtoomuchandoperatethecyclingthermalswitch.Iftheshowercycles
hot/cold ensure shower heads are clean and reduce temperature at control.
This manual suits for next models
1
Table of contents
Popular Thermostat manuals by other brands

Lennox
Lennox icomfort Touch Thermostat Homeowner's manual

Honeywell
Honeywell RTH8500D - 7-Day Touchscreen Universal Programmable... owner's guide

Siemens
Siemens RDG165KN operating instructions

CAME
CAME BPT TA/600 Installation and use manual

King Electrical
King Electrical K101-C Installation and Maintenance

Honeywell
Honeywell C owner's guide