The instructions in this manual contain important information on the safe mounting, usage, cleaning
and maintenance of the device. Thus, keep the manual at a place easily accessible by the person who
will use the machine, and the technician.
Mounting, conversions for different gas groups or electrical inlet, and maintenance works of the
device should be performed by a specialist authorized in this subject and in accordance with the
instructions of the manufacturer company.
Gas and electrical connections of the device should be arranged according to the tables and electrical
diagram given in this manual.
Manufacturer Company accepts no responsibility for the final damages incurred in humans or
properties that are caused by any procedure not conforming to the instruction manual, or maintenance
or technical interventions that are not performed by authorized people.
TYPES
G K100G – 00 serie ½ module counter top
G K200G – 00 serie 1 module counter top
G7K100G – 700 serie ½ module w/ cupboard
G7K200G – 700 serie 1 module w/ cupboard
G7K201G – 700 serie 1,5 module w/ cupboard
G7K210G – 700 serie 1 module w/oven
G7K211G – 700 serie 1,5 module w/ cupboard and oven
G9K100G – 900 serie ½ module w/ cupboard
G9K200G – 900 serie 1 module w/ cupboard
G9K201G – 900 serie 1,5 module w/ cupboard
G9K210G – 900 serie 1 module w/oven
G9K211G – 900 serie 1,5 module w/ cupboard and oven
G9K212G – 900 serie 1,5 module w/ oven
MOUNTING INSTRUCTION
Placement
Installation and adjustment of the device should be carried out by technical staff of the Authorized
Service.
Place the device at a place min. 10cm away from the side or back wall to prevent excessive
temperature rises.
Place the device beneath a filtered exhaust hood in order to eliminate smell and fume that may be
emitted during cooking.
Device should be placed on a flat surface by suitably balancing on the four adjustable legs. (Figure A)
Remove the protective nylon on the device. Clean the adhesive particles left on the device with a
suitable cleaner.
Never leave flammable material near the device.
GAS CONNECTION
Device should be connected in accordance with the national and local gas standards of the relevant
country.
Gas inlets “G” of the device are indicated with a label on device body.
Connection to the gas installation should be made with flex pipe and ball valve. Fix the said ball valve
to a place that is away from heat and easily accessible in case of a danger.
After gas inlet connection is completed, check for possible gas leakages.

Feed the device with the gas and pressure as specified on device information plate and adjusted. If the
gas type to which the device was adjusted for is not suitable to the gas type at the mounted place,
follow the instructions written below.
ATTENTION: All adjustments and modifications to be pe fo med on the gas installation and
connection of the device should be pe fo med by autho ized people.
ADJUSTMENT ACCORDING TO DIFFERENT GAS TYPES
If the device is connected to gas installation, close main gas inlet valve.
Replacement of top burner nozzles ( Figure B)
a. Remove cooker grater(1), top burner cover (2) and oil tray (3) (G K-100-200G-G7-9K100-200-
201-210-211G)
b. Replace nozzle (5) with a nozzle suitable for the gas type
c. Adjust the flame of the pilot burner by turning the bolt (4)
Replacement of oven nozzles (Figure C , D) (G7-9K210-211-212G)
a. Take out lower metal sheet ( ) of oven door by removing its bolts (7) (Figure
C)
b. Replace oven nozzle (8) with a nozzle suitable for the gas type (Figure D)
c. Replace pilot nozzle of oven pilot burner (9) with a nozzle suitable for the
gas type (Figure D)
OPERATOR INSTRUCTIONS AND ATTENTION POINTS
With the aim of eliminating the malodour and fume caused by the isolation
of the stove oven, adjust the oven thermostat to the highest value in the first start-up and operate it
unloaded for a while with its door open.
Gas taps of cooker and oven has safety valve; if the main flame goes out for any reason, gas flow is
cut off automatically.
Do not cook on cookers with the lower oil pan removed.
Do not operate the oven with its back funnel mouldings removed or closed.
STARTING-UP COOKERS (700-900 Se ie)
Turn the main gas valve to open position.
Turn the cooker gas button to pilot flame position “ ” by pushing it gently and ignite the pilot
with an external flame source from the hole near the cooker burner.
After the pilot is ignited, keep the button pressed for a few seconds min. 10 to heat the safety
thermocouple end.
Later, you can adjust it to the desired position by turning to half “ ” or full flame ” ”
If the device is operated for the first time, keep the button pressed at pilot burner flame position for a
while before ignition to discharge the air in the gas installation.
STARTING-UP COOKERS (600 Se ie)
Turn the main gas valve to open position.
Turn the cooker gas button to pilot flame position “ ” by pushing it gently and ignite the pilot
with an external flame source from the hole near the cooker burner.
Later, you can adjust it to the desired position by turning to half “ ” or full flame ” ”
If the device is operated for the first time, keep the button pressed at pilot burner flame position for a
while before ignition to discharge the air in the gas installation.

TURN OFF (700-900 Serie)
Turn the cooker gas button to pilot flame position “ ”, only pilot burn occurrs. Turn to
position “0” to turn off completely.
TURN OFF ( 00 Serie)
Turn to position “0” to turn off completely.
STARTING-UP THE OVEN (Figu e E) (700-900 Se ie)
Turn to the side part (11) to see the pilot burner
Turn the oven button (13) to pilot position by pressing it gently
Push button (14) and Ignite the pilot by pushing the button (12). Keep pressed button (14) for a few
seconds (min. 10) to heat the safety thermocouple end.
Then, you can adjust the heat by turning the button left according to the temperature degrees indicated
on the scale of button (11)
TURN OFF
Turn oven or its button to pilot position. In this position, only pilot burn occurrs. Turn to position “0”
to turn off completely.
Push button (15) then it will be off the oven
Wait min. 2 min before ignite the oven if turn off it by pushing button 15
MAINTENANCE
Never perform maintenance without closing the main gas valve of the device.
Before it cools down completely, wipe the device with a cloth immersed in warm soapy water.
Do not use cleaning substances and tools that may cause scratches on device surface.
If required, use chemical cleaners.
Do not clean the device with pressurized water or vapour.
Take out lower oil trays of oven and oven grates, and clean them with warm water and soap daily.
If the device will not be used for a long period, coat the surfaces with a thin layer of Vaseline.
ATTENTION: Any part replacement that may a ect sa ety must be carried out by the authorized
people. During maintenance and repair, keep the main gas valve closed and keep away ire.
Always per orm leakage check a ter repair or part replacement; use oam or gas detector or
this aim. In case o any dangerous condition with the device, noti y to the authorized service.
Do not allow unauthorized people to inter ere in the device.
DANGEROUS: Never allow leakage check to be per ormed with lame.

Figu e A
52
1

Şekil B
Figure B

Şekil D
Figure D
Şekil E
Figure E

G7I211G
G7K210G
G7K200G
G7K100G
G7K212G

G9K100G G9K210G
G9K211G
G9K201G
G9K200G
G9K212G

730
900
400
GAZ GİRİŞ
GAS INLET
G7K100G
730
900
800
GAZ GİRİŞ
GAS INLET
G7K200G
730
900
800
GAZ GİRİŞ
GAS INLET
G7K210G
730
900
1200
GAZ GİRİŞ
GAS INLET
G7K201G
730
1200
GAZ GİRİŞ
GAS INLET
532
478
532
21
900
G7I211G
730
1200
GAZ GİRİŞ
GAS INLET
21
10 3
4
900
G7K212G

B
C
A
GAZ GİRİŞ
GAS INLET
215
252 97
G9K100G
B
A
GAZ GİRİŞ
GAS INLET 21
52 97
C
G9K200G
B
A
GAZ GİRİŞ
GAS INLET
1052 97
17
C
G9K201G
B
A
GAZ GİRİŞ
GAS INLET 21
3
59
C
G9K210G
B
A
GAZ GİRİŞ
GAS INLET 21
532 97
532
C
G9K211G
B
A
GAZ GİRİŞ
GAS INLET 21
10 3
59
C
G9K212G
Other manuals for 600 Series
1
This manual suits for next models
16
Table of contents