The following tables contain information on measured current consumption as well as calculated heat dissipation during normal operation
(1/8 rated power); and during extreme heavy duty operation (1/4 rated power).
Current Draw and Thermal Dissipation
FP+ Series: Dedicated Touring Amplifiers
FP 10000Q
FP 10000Q
Level Load Rated Power Line Current *2) Watt *1) Thermal Dissipation
115 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
Standby, with remote power off via NomadLink 0 0 0 0 0
Powered on, idling 139 0139 475 120
Amp (I) Watt
Pink noise (1/8
rated power)
16 Ω/ Ch. 660 x 4
10.7 5.6 732 330 402 1371 345
32 Ω/ Bridged 1320 x 2
8 Ω/ Ch. 1300 x 4
16.9 8.8 1224 650 574 1958 493
16 Ω/ Bridged 2600 x 2
4 Ω/ Ch. 2100 x 4
25.9 13.5 1914 1050 864 2949 743
8 Ω/ Bridged 4200 x 2
2 Ω/ Ch. 2500 x 4
32.2 16.8 2414 1250 116 4 3973 1001
4 Ω/ Bridged 5000 x 2
Pink noise (1/4
rated power)
*3)
16 Ω/ Ch. 660 x 4
13.6 7.1 1143 880 263 897 226
32 Ω/ Bridged 1320 x 2
8 Ω/ Ch. 1300 x 4
22.4 11.7 2096 1733 363 1238 312
16 Ω/ Bridged 2600 x 2
4 Ω/ Ch. 2100 x 4
39.4 20.6 3589 2800 789 2691 678
8 Ω/ Bridged 4200 x 2
2 Ω/ Ch. 2500 x 4
52.9 27.6 4159 3333 825 2817 710
4 Ω/ Bridged 5000 x 2
Mains connector, 230 V CE version 16 A, CEE7
Mains connector, 115 V ETL version 30 A, Nema L5 -30P Twist lock
*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and
specified here is what is known as the “Active Power” of the amplifier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum power before amplifier protection and limiter features are engaged. Typically this is between 1/4 and 1/3 of rated
power. Note that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be
tripped even if operation is in excess of max. ratings.