LaCoSys SMART PICKER SERIES User manual

Manual SmartPicker AOM Rev. A ENG LaCoSys Nov 2017
-2-
1Introduction
To know this manual is essential for operating with the system. Please read it carefully and comply with the
hints for safe work with the device.
It is our policy to constantly improve the design and specifications. Accordingly, the details represented here
cannot be regarded as final and binding.
© Dissemination and copying of this manual are allowed on special request only.
All rights reserved for the case of patent or registered-design application.
More information is available at the manufacturer http://www.lacosys.com/ or at the responsible distributor.
Manufacturers address:
LaCoSys GmbH
Hans-Knöll-Straße 6
D-07745 Jena, Germany
Phone:
(+49) 3641 / 2241514
E-Mail:
Web:
http://www.lacosys.com
Date: November 2017

Manual SmartPicker AOM Rev. A ENG LaCoSys Nov 2017
-3-

Manual SmartPicker AOM Rev. A ENG LaCoSys Nov 2017
-4-
Content page
1 Introduction.............................................................................................................................2
2 Safety information ...................................................................................................................5
2.1 General notes / Symbols...........................................................................................................5
2.2 Electric safety / Personnel protection insulation........................................................................6
2.3 Laser safety / labeling...............................................................................................................7
2.4 Intended use ............................................................................................................................7
3 Description of the system .........................................................................................................8
3.1 General ....................................................................................................................................9
3.2 AOM-output (SMA) ..................................................................................................................9
3.3 AOM-MONITOR (OUTPUT)........................................................................................................9
3.4 GATE-INPUT ...........................................................................................................................10
3.5 PHOTODIODE INPUT (TRIGGER-IN)..........................................................................................10
3.6 PHOTODIODE MONITOR OUTPUT ...........................................................................................10
3.7 Mains.....................................................................................................................................11
3.8 USB-Connection .....................................................................................................................11
3.9 AOM –INTERFACE..................................................................................................................11
4 Use of the device....................................................................................................................12
4.1 Unpacking and installation .....................................................................................................12
4.2 First steps...............................................................................................................................12
4.3 Installation of software drivers ...............................................................................................13
4.4 Installation of LabView SmartControl AOM .............................................................................13
4.5 Software description ..............................................................................................................13
5 Maintenance information.......................................................................................................17
5.1 Warranty ...............................................................................................................................17
5.2 Maintenance..........................................................................................................................17
5.3 Service ...................................................................................................................................17
5.4 Transport ...............................................................................................................................18
5.5 Disposal .................................................................................................................................18
6 Technical Data........................................................................................................................19
6.1 General data ..........................................................................................................................19

Manual SmartPicker AOM Rev. A ENG LaCoSys Nov 2017
-5-
2Safety information
2.1 General notes / Symbols
Please read the manual carefully before putting the device into operation.
For more information of if you have questions you can contact our service or web-site www.lacosys.com .
The device was designed and built according to the standard DIN EN 61010-1 (IEC 61010-1) "Safety
requirements for electrical equipment for measurement, control and laboratory use".
The device complies with the European Directive 2004/108/EG "Electromagnetic compatibility".
The device is labelled with the - sign.
The device will be disposed according the guideline WEEE- 2002/96/EG.
Warning notes and symbols in this manual:
NOTE
This symbol marks if special attention must be paid for a fact while using the device.
ATTENTION
This symbol marks if danger for the user of the device may occur.
ATTENTION
This symbol marks a danger for the device.
ATTENTION
Laser-radiation may be emitted!
ATTENTION
Electrostatic delicate components.
ATTENTION
Please use appropriate safety precautions against electrostatic discharge (safety pack, antistatic
wristband etc.)

Manual SmartPicker AOM Rev. A ENG LaCoSys Nov 2017
-6-
2.2 Electric safety / Personnel protection insulation
The device operates with dangerous voltages internally. Do not open the device or remove pars of the case. It
is not allowed to work inside the case or at parts under dangerous voltage by the user.
The device must be used as delivered. Every modification voids warranty or liability.
All cables must be electrically insulated. The customer service or authorized staff is allowed to open
the device only.
The IP code of the device is IP2X.
Please switch off the device if you do not intend to use it for a longer time.
ATTENTION
Electrostatic charges on persons and objects may cause voltages up to 4000 V. They can discharge
invisible. To prevent aging or damage it is important to use precautions against electrical charging.

Manual SmartPicker AOM Rev. A ENG LaCoSys Nov 2017
-7-
2.3 Laser safety / labeling
The device is designed for use with lasers. Please respect the signs and regulations of DIN EN 60825-1.
Kennzeichnungen und Vorschriften nach DIN EN 60825-1 gekennzeichnet.
Fig. 1 Identification label at the device
RoHS statement
The device and all components comply with RoHS Directive 2011/65/EU (RoHS).
WEEE-sign (ElektroG) - Waste of Electrical and Electronic Equipment.
The device is labelled with the symbol
2.4 Intended use
The device is intended for driving of a RF-Driver with acusto-optical modulators (AOM). The RF-Driver must be
provided with inputs for the TTL-Signal (input low impedance 50 Ω or up to 10k Ωhigh impedance).
The device use FC-Fibre connector as Trigger –input for the pulses. For this a fibre coupler can be used which
guides a part of the output light (5 - 10 %) to input. Since an InGaAs-photodiode is built in the wavelength can
be between 1000 nm and 1700 nm.
Please store the manual near to the device and accessible for all users.
Furthermore, please take care that all necessary documents like laser safety regulations or country-
specific safety regulations are present.

Manual SmartPicker AOM Rev. A ENG LaCoSys Nov 2017
-8-
3Description of the system
Device name: Smart Picker AOM
Description: Pulse or pulse picker control unit for acusto-optical modulators
Fig. 2 Front panel
1 POWER LED
6 PHOTODIODE MONITOR SMA(f)
2 AOM-TTL OUT SMA(f)
3 AOM-TTL MONITOR OUT SMA(f)
4 GATE-TTL INPUT
5 PHOTODIODE FC
Fig. 3 Rear panel
1 AOM INTERFACE –SUB-D15 (f)
4 On/Off Switch
2 USB-Connection
3 24VDC Input
1
2
3
4
5
6
1
2
3
4

Manual SmartPicker AOM Rev. A ENG LaCoSys Nov 2017
-9-
3.1 General
The SmartPicker is characterized by:
-Divider 1 …65535
-Single Pulse Check
-Input Power Check
-Build in photodiode
-Synchronize up to 200MHz
-Stable EMC shielded aluminium case
-Integrated USB port
-Trigger-Level input down to 50mV
-TTL monitor output
-Variable delay in the range 0 ns ... 1 ms
-Variable pulse width in the range 12 ns ... 1 ms
The device is intended for use as table top device. It must be used in horizontal position. Please
protect it against shifting.
3.2 AOM-output (SMA)
Output
Connector: SMA(f)
Voltage: TTL (square wave)
Current: ± 100 mA
TRise / TFall: < 1.5 ns
A driver for acusto-optical modulator (AOM) needs typical TTL voltage pulses for switching between the off
and on states. The exact value is given in the data sheet of the AOM –Driver.
The AOM-output is optimized for an output impedance of 50 Ω. Shortening the output may lead to
irreparable device damage.
The AOM-output is optimized for an output impedance of 50 Ω. For other output impedance values
the voltages are not correct.
3.3 AOM-MONITOR (OUTPUT)
Output
Connector: SMA(f)
Voltage: TTL (square wave)
Current: ± 100 mA
TRise / TFall: < 1.5 ns

Manual SmartPicker AOM Rev. A ENG LaCoSys Nov 2017
-10-
For monitoring the AOM Driver Signal is duplicated on this port.
The AOM-Monitor output is optimized for an output impedance of 50 Ω. Shortening the output may
lead to irreparable device damage.
The AOM-Monitor output is optimized for an output impedance of 50 Ω. For other output
impedance values the voltages are not correct.
3.4 GATE-INPUT
Input
Connector: SMA(f)
Voltage: TTL/LVTTL
Frequency: < 100 MHz
Input impedance: 50 Ω
Minimum pulse width: 100 ns
The GATE-INPUT provide a logical AND-Function for the AOM-OUTPUT.
Truth table:
Input
HIGH AOM –OUTPUT DIVIDED PULSES
LOW AOM - OUTPUT BLOCKED
3.5 PHOTODIODE INPUT (TRIGGER-IN)
Input (optical)
Connector: FC (f)
Input Power: max. 10mW (cw)
Pulse Repetition Rate: max. 200 MHz
An optical pulse at the Trigger input increases a counter until a software pre-set value is reached. Then a TTL-
pulse is emitted at the AOM-output. The AOM-output pulse will have the pulse width and delay which was
pre-set using the software. The counter will be set back and counts again following the next Trigger input
pulses.
3.6 PHOTODIODE MONITOR OUTPUT
Output
Connector: SMA(f)
Voltage: Pulses < 2Vpp
Current: ± 100 mA
TRise / TFall: < 1.5 ns

Manual SmartPicker AOM Rev. A ENG LaCoSys Nov 2017
-11-
The PHOTODIODE-Monitor port provides a monitoring signal for the photodiode input. Here we advise to
check level. Minimum 50mV (150mV for optimal function)
The Photodiode-Monitor output is optimized for an output impedance of 50 Ω. Shortening the
output may lead to irreparable device damage.
The Photodiode-Monitor output is optimized for an output impedance of 50 Ω. For other output
impedance values the voltages are not correct.
3.7 Mains
Input
Connector: DC-PLUG 2,5mm
Voltage: 24VDC
Current: 2 A max.
Use only the delivered power supply. The supplied mains cable with an IEC 60320 C13 connector or an
identical one must be used. It can be custom- or country specific.
3.8 USB-Connection
Please use a standard USB A-B cable for connecting the device with a PC. The installation of the needed drivers
takes place automatically in most cases. More details can be read in chapter 4.3.
3.9 AOM –INTERFACE
Output
Connector: SUB D 15 (f)
PIN 1 5V
PIN 2,4,7,10,12,14 GND
PIN 3 TTL-OUT @5mA
PIN 5,6,8 NC
PIN 9,11,13,15 24V-DC (max.2A)
The AOM interface provide an easy connection for example RF-Driver from manufacturer AA
http://www.aaoptoelectronic.com/Documents/MODAxx-MODAGxx-2014.pdf.
Here we advise to use the TTL-Version.
The AOM-Interface output is optimized for 24V-DC Drivers. Shortening the output may lead to
irreparable device damage.

Manual SmartPicker AOM Rev. A ENG LaCoSys Nov 2017
-12-
4Use of the device
4.1 Unpacking and installation
Please verify the packaging if it is damaged. Any damage must be announced to the carrier and the
manufacturer after receipt. Please verify if the package is complete:
4.2 First steps
Connect the mains cable with the delivered power supply and connect the DC-Pug to the device.
Only use the delivered power supply!
Connect a USB A-B –cable with the device and your PC.
You may need administrator rights to install the necessary software drivers depending on the
operating system.
The software driver installation proceeds automatically if Microsoft Windows 7 or higher is used. For more
information please read chapter 4.3.
Fig. 4: Scheme of a set-up
A possible set-up of the SmartPicker AOM with a AOM-Driver and modulator is depicted in Fig. 4. Your set-up
may differ from this. The oscilloscope can used on monitor ports for the visibility of the electrical pulses for
modulator control.
Description
Number
SmartPicker tabletop device
1
Mains cable
1
Documentation (manual, usb-stick)
1
Power supply
1

Manual SmartPicker AOM Rev. A ENG LaCoSys Nov 2017
-13-
4.3 Installation of software drivers
A virtual COM-port driver is needed for the communication via USB. For systems of Microsoft Windows 7 or
higher the driver installs automatically if the PC is connected with the Internet. To do this you must only
connect the USB-cable. The driver installs automatically. It is not necessary to switch the SmartPicker AOM on.
This process can take some time.
For all other systems the drivers must be downloaded from the website of the driver manufacturer:
http://www.ftdichip.com/Drivers/VCP.htm . Please connect the USB cable after the drivers installation.
A new COM-port is displayed in the device manager of your system after successful installation.
You may need administrator rights to install the necessary software drivers on your PC depending on
the operating system. Please contact your IT-service.
4.4 Installation of LabView SmartControl AOM
The SmartPicker is controlled by SmartControl AOM Software.
For installation please start the setup.exe on delivered USB-Stick and follow the instructions.
4.5 Software description

Manual SmartPicker AOM Rev. A ENG LaCoSys Nov 2017
-14-
System Settings:
In this section the system parameters for the picking regime is setup. With the Single Pulse Check you can
ensure that the system stops permanently when on the trigger input pulses are missed or skipped.
New pulse sequences can be generated by extracting single pulses or pulse bursts from pulsed lasers. This is
determined by the repetition rate of the signal source and the division factor.
The AOM´s operation principle and use are described in the AOM´s manual. Please contact our service if you
need more information.
Divider ... set up the divider for the input pulses
Delay … setup the delay from 0 to 1.000.000ns
Pulse width ... setup the pulse width from 0 to 1.000.000ns
Attention, Delay must be smaller than output period time
Attention, Pulse width must be smaller than output period time
!

Manual SmartPicker AOM Rev. A ENG LaCoSys Nov 2017
-15-
SPC Settings:
For the Single Pulse Check an internal independent 100MHz clock is used. You may choose an appropriate
value for the check. For example:
Input frequency = 20 MHz
choosing 9 to ensure that asynchrony clocks not trigger the system and smaller then twice the calculated
number.
SPC –ON/OFF … activate the Single Pulse Check and show the actual state
Single Pulse Check … setup the value for the check 0…255
Save Settings … save system setting and spc settings actual values in the device
Limit Settings:
In this section you can use the additional Level Check to ensure signal quality and power at optical input port.
When activated the AOM Output and monitor Port is blocked in any case of limit error.

Manual SmartPicker AOM Rev. A ENG LaCoSys Nov 2017
-16-
A photo diode is integrated in the device. Please respect its maximum optical power of 10 mW.
Overload leads to damage of the photo diode.
MAX LEVEL … setup maximum level of photodiode input port
LOW LEVEL … setup minimum level of photodiode input port
SAVE –LIMITS … save the actuals values in the device
LIMITS- ON /OFF ... turn on off the level check
Photovoltage:
This chart shows the actual peak value of the optical input.
Info Section:
Here you find information to Type, Serial an Product IDS
CLOSE:
Stop the Program.

Manual SmartPicker AOM Rev. A ENG LaCoSys Nov 2017
-17-
5Maintenance information
5.1 Warranty
The device manufacturer guarantees that the device is free of material or production faults. Please tell us
immediately if faults occurred.
There is no warranty if the fault is caused by natural wear (especially at wear parts) or incorrect use.
The device manufacturer is not liable for damages which are caused by incorrect use, negligence or
interference at the device, especially by removal or exchange of device parts and the use of accessories of
other manufacturers. The warranty expires in this case.
LaCoSys declines any liability for damages which are due to disregard of the safety information.
5.2 Maintenance
Please switch off the device and remove the mains cable before maintenance!
Please respect the cleaning instructions of the devices of other manufacturers which are used in
combination with the SmartPicker.
•Don´t use cleaning powders, diluents or solvents like benzine or acetone because this might affect the
devices surface.
•Cleaning should be done using a soft wet tissue and mild soap.
5.3 Service
Any service-, maintenance, adjustment and cleaning work must be done by the service or authorized staff.
Only authorized staff is allowed to open the device.

Manual SmartPicker AOM Rev. A ENG LaCoSys Nov 2017
-18-
5.4 Transport
Please respect the following hints for safe transport. The warranty expires at if they are disregarded!
The SmartPicker is sensitive against electrostatic discharge. The discharge if static electricity for
example from the fingers can shorten the devices lifetime or damage it. Please use appropriate
safety precautions against electrostatic discharge (grounding, antistatic wristband etc.)
Only use packing or wrapping materials which are appropriate for electrostatic sensitive devices.
Please don´t use styrofoam or simple air cushion foils.
Please use the original package preferably.
5.5 Disposal
Defect devices must be disposed according the legal rules. Do not put it into the domestic waste.
The device manufacturer is obligated by law to withdraw defect devices.

Manual SmartPicker AOM Rev. A ENG LaCoSys Nov 2017
-19-
6Technical Data
6.1 General data
Length x Width x Height
240 mm x 125 mm x 36 mm
Mass
1 kg
Mains
24 DC
Power consumption
< 30 W
Maximum switch-on current
< 1 A
Location of use
Only for inside use
Protection class
II
Degree of protection
IP 20
Radio interference suppression
DIN EN 55011 class A
Noise immunity
EN 61000-6-2 (industrial environment)
Environmental conditions:
Temperature range:
Operation:
Storage:
Relative Humidity:
Operation:
Storage:
Vertical height of use:
Operation:
Storage:
10 … 40 °C
-10 ... 60 °C
80 % (non-condensing)
99 % (non-condensing)
3000 m
12000 m
Installation position
Horizontal
Please visit our website www.lacosys.com . You will find more information about further models.