Manual
power[cube] incl. Data Logger met[LOG]
Id-No. 30.95800.015000
power[cube] incl. Data Logger met[LOG]
with Wi-Fi Router
Id-No. 30.95800.115000

________________________________________________________________________________________________
________________________________________________________________________________________________
2
Power[cube] Wi-Fi with met[LOG]
When met[LOG] is delivered it has an automatic reference to an IP address via a DHCP server.
The Wi-Fi module is pre-configured to create an own, (initially) unsecured Wi-Fi network.
In a few steps this network can be:
⇒renamed
⇒secured (with password)
⇒integrated as a station in an existing network
Create first connection with met[LOG]
Needed information:
MAC address Wi-Fi module
Wi-Fi name Wi-Fi module
(factory setting) (name ends
with the last 4 signs of the
MAC address (without „:“ or
„-“)
USR-WIFI232-630_
1.) Connect power[cube] to mains power
In condition as delivered to the customer the Wi-Fi module works with address area 10.10.100.100 to
10.10.100.253 and assigns met[LOG] an appropriate IP address.
The Wi-Fi module has the IP address 10.10.100.254 when it’s delivered.
2.) Open Wi-Fi settings at notebook, PC or tablet, choose Wi-Fi net USR-WIFI232-630_xxxx and connect.
„xxxx“ refer to the last 4 sign of the MAC address of the Wi-Fi module. The network is uncoded and
unprotected. So, there’s no need to type a pass word.
3.) With an IP scanner the IP address can be found which the met[LOG] has been assigned from the DHCP
server of the Wi-Fi module. For this scan the address area 10.10.100.1 to 10.10.100.254 for met[LOG] or its
MAC address. You can find the MAC address of met[LOG] at the housing side of met[LOG] and the inner
side of power[cube]. Alternatively you can find all units of the network with their MAC address and IP address
be found when using the prompt in Microsoft Windows with the command „arp –a“ (don’t forget the blank and
set only ONE blank)
Normally only the computer and met[LOG] are registered in the network at the beginning. Thus, met[LOG]
mostly has the IP address 10.10.100.100 or 10.10.100.101.
Make a note of the MAC and IP address hereunder:
MAC address met[LOG]
IP address met[LOG]
4.) When entering the met[LOG] IP address in a browser the connection to met[LOG] will be made. (See also
the met[LOG] handbook)

________________________________________________________________________________________________
________________________________________________________________________________________________
3
Setting of a secured Wi-Fi with met[LOG]
1.) The USR-WIFI232-630 Wi-Fi module in power[cube] can be reached under IP address 10.10.100.254 via
a browser.
2.) Log in at the website of the Wi-Fi module as user „admin“ with the password „admin“.
3.) The website of the Wi-Fi module is available in English and Chinese. In condition as delivered to the
customer English is set as standard. In case Chinese is set the language can be changed via the link
„English“ which is located in the upper right side.
4.) Open the page „Quick Configure“ via the correspondent link.
5.) You can change the name of the network if you like (Network Name(SSID)), e.g. to „met[LOG]-Wi-Fi“.
Make a note of the network name hereunder:
6.) Activate the network security via the button next to „Security Mode“. We suggest „WPA2-PSK“. According
to the choice further buttons will be shown. We suggest choosing “AES” as „WPA Algorithm“.
7.) Set a password for the network in the field next to „Pass Phrase“, e.g. „met[LOG“.
Make a note of the password hereunder:
Secure the password against unauthorized use!
Network name:
Password:

________________________________________________________________________________________________
________________________________________________________________________________________________
4
8.) To save the configuration press „Apply“.
9.) All other settings in the quick configuration can remain unchanged.
10.) Scroll until the end of the page and restart the Wi-Fi module by pressing „Restart“. By doing the restart
the changed configuration will work.
11.) After restart you reach the met[LOG] via the secured Wi-Fi network with afore set name and password,
e.g.:
Network name: Met[LOG]-Wi-Fi
Password: Met[LOG]
The IP address of the met[LOG] remains unchanged (e.g.: 10.10.100.100). For this please see the chapter
„Make the first connection to met[LOG]“ Point 3. and 4.
11.) By entry of the met[LOG] IP address in a browser you make the connection to met[LOG]. (See also the
met[LOG] handbook)

________________________________________________________________________________________________
________________________________________________________________________________________________
5
Integration in an existing network with an own DHCP server via Wi-Fi
Following the previous chapter the network in the following configuration example has the Wi-Fi name „FB-
LM“ and the address area 192.168.100.1 - 192.168.100.254. The password of the network is „1234567890“.
These data have to be replaced with the data of the existing network in which the power[cube]-Wi-Fi is
integrated.
Needed information:
MAC address Wi-Fi module
Destination WiFi name:
password destination WiFi:
Free IP address (fix) in destination Wi-
Fi for Wi-Fi module
Subnet mask of destination network
(e.g. 255.255.255.0)
Security mode of destination network
(z.B. WPA2PSK)
Encryption type of destination network
(e.g. AES)
1.) Connect with Wi-Fi „met[LOG]-Wi-Fi“; Password: „met[LOG]“ (See example in previous chapter)
2.) The USR-WIFI232-630 Wi-Fi module in power[cube] is reachable under the IP address 10.10.100.254 via
a browser.
3.) Log in at the website of the Wi-Fi module as user „admin“ with the password „admin“.
4.) Open the page „Quick Configure“ via the correspondent link.
5.) Change the Wi-Fi mode in „STA Mode“ (Station Mode). According the choice further fields will be shown.

________________________________________________________________________________________________
________________________________________________________________________________________________
6
6.) Start the search for available networks by confirming the button „Search“ next to „AP‚s SSID). Another
window will open.
7.) Choose the Wi-Fi network in which the power[cube] Wi-Fi shall be integrated. In the present example it is
the network with SSID (Name) „FB-Lm“.
8.) To save press the button „Apply“.
9.) Please make the following settings for the chosen network in „Quick Configure“:
Security Mode
Chosen security mode of the network,
e.g. „WPA2PSK“ (can be found in the
upper search window)
Encryption Type
Chosen encryption code, e.g. „AES“ (can
be found in the upper search window)
Key
Netzwork password, e.g. „1234567890“
10.) To save the configuration press the button „Apply“.

________________________________________________________________________________________________
________________________________________________________________________________________________
7
11.) Open the page „AP Interface Setting“ via the corresponding link.
12.) Change the LAN settings (LAN Setup) of the Wi-Fi module:
IP Address (Default
DHCP Gateway)
Free IP address (fix) in destination Wi-Fi for
Wi-Fi module
Subnet Mask
Subnet mask of destination network (e.g.
255.255.255.0)
DHCP Type
Disable – Deactivate the DHCP server of
the Wi-Fi module.
(Rest)
(Unchanged)
13.) All other settings in „AP Interface Setting“ can remain unchanged.
14.) To save the configuration press „Apply“.

________________________________________________________________________________________________
________________________________________________________________________________________________
8
15.) Scroll until the end of the page and restart the Wi-Fi module by pressing „Restart“. By doing the restart
the changed configuration will work.
16.) Disconnect the met[LOG] or the complete power[cube] Wi-Fi from mains power supply (e.g. by opening
the fuse terminal) and wait until all LEDs have gone out. After this switch on the met[LOG] / complete
power[cube] Wi-Fi again.
17.) Now the met[LOG] gets a new free IP address via the DHCP server of the destination network.
18.) With an IP scanner the IP address can be found which the met[LOG] has been assigned from the DHCP
server of the Wi-Fi module. For this scan the address area of the destination network for the MAC address of
the Wi-Fi module. Alternatively you can find all units of the network with their MAC address and IP address
be found when using the prompt in Microsoft Windows with the command „arp –a“ (don’t forget the blank and
set only ONE blank). You can find the MAC address of met[LOG] at the housing side of met[LOG] and the
inner side of power[cube].
As the met[LOG] is integrated in the destination network via the Wi-Fi module now it is shown by the
command „arp –a“ in a generated list with the IP address of the Wi-Fi module. Search in the listed IP
addresses for the IP address of the Wi-Fi module and make a note of the corresponding MAC address. Now
search the list for further IP addresses with the same MAC address. Normally the second IP address is the
met[LOG]’s. Find further IP addresses with the same MAC address, please read the remark „Repeater“.
In case the MAC address is not shown immediately please wait 1-2 minutes and search the network for the
MAC address again.
Remark: „Repeater“: In case a repeater is in use it can happen that the Wi-Fi module and the met[LOG] is
listed with the MAC address of the repeater or the listing is disturbed by the repeater. If you don’t find the
met[LOG] deactivate the Repeater and start the search again. If the met[LOG] still can’t be found restart the
power[cube]-Wi-Fi and start the search again after approx. 1 minute.
Remark: We suggest to search the IP addresses via an Ethernet-cable connected to a PC that is integrated
in the network.
If applicable you can allocate a fixed IP address to the met[LOG]. (See met[LOG] handbook)
Make a note of the MAC address of the Wi-Fi module and the IP address of the met[LOG] hereunder:
MAC address WiFi-module
IP address met[LOG]
19.) By entry of the met[LOG] IP address in a browser you make the connection to met[LOG]. (See also the
met[LOG] handbook)

________________________________________________________________________________________________
________________________________________________________________________________________________
9
Return Wi-Fi module to factory settings
There are 2 ways to return the Wi-Fi module to factory settings:
- via software button on the configuration webpage of the Wi-Fi module
- via hardware button at the outside of the housing below the green 3-pole terminal
Factory setting via configuration webpage
If the Wi-Fi module can still be reached via the browser you can return to factory setting with the „Load
Default Button“ at the page „Device Management“ of the Wi-Fi module.
The Wi-Fi module has following default settings:
IP address: 10.10.100.254
User: admin
Password: admin
Wi-Fi name Wi-Fi module: USR-WIFI232-630_XXXX
(the name ends with the last 4 signs of the MAC address (without „:“ or „-“)
1.) Open the page „Device Management“ via the corresponding link.
2.) By pushing the „Load Default Button“ the device returns to factory settings.
Factory settings via hardware button at the outside of the housing
At the outside of the housing below the 3-pole terminal is a small hardware button. By pushing the same in
activated mode (Power LED and Ready LED ON) for at least 3 seconds the Wi-Fi module returns to factory
settings.
1.) Dismantle the Wi-Fi module from the cap rail by pushing it upwards and tilting outwards. Alternatively you
can unscrew the antenna and the 3-pole terminal to reach the hardware button.
2.) Push the hardware button in activated mode (Power LED and Ready LED ON) for at least 3 seconds.
3.) Loose the hardware button and wait 10 seconds while the Wi-Fi module is re-initialisating. The Ready

________________________________________________________________________________________________
________________________________________________________________________________________________
10
LED switches Off shortly and the LEDs „net1“ and „net2“ flash very shortly. When the Ready LED flashes
again the Wi-Fi module is returned to factory settings and be reached again via the Default-I P.
Technical Data
(14966) power[cube] Ident-Nr. 00.14966.715 000
Output power-supply: 24 VDC
Output voltage range: 24...28 V
Output current: max. 6,5 A
Input voltage range: 90...264 VAC
Input frequency: 47...63 Hz
Effective power: 156 W
Temperature range: -20...+60 °C
Storage temperature: -40...+85 °C
Dimensions: ca. 190 x 190 x 190 mm
Accessories: Mast fixation for power[cube]
(optional) Ident-Nr. 32.14966.030 000
Version:
power[cube] „Wi-Fi“ power[cube] incl. Data logger met[LOG] and Wi-Fi router
Ident-Nr. 30.95800.115000
power[cube] power[cube] incl. Data logger met[LOG]
Ident-Nr. 30.95800.015000
Subject to change without notice.
BA_WiFi_powercube_metLOG_e (13.20)
______________________________________________________________________________________
LAMBRECHT meteo GmbH Tel +49-(0)551-4958-0
Friedlaender Weg 65-67 Fax +49-(0)551-4958-312
37085 Goettingen E-Mail info@lambrecht.net
Germany Internet www.lambrecht.net
This manual suits for next models