Langmatz basicguide EK 524 User manual

Operating Instructions
Signal Requesting Device
for Pedestrians and the Visually Impaired
basicguide EK 524

2
Contents
English
General information 3
Safety information 3
Product description 4
3.1 Dimensions 4
Technical data 4
4.1 General 4
4.2 Tactile signalling device 5
4.3 Visual feedback 5
4.4 Signal request by vibrator push-button 5
4.5 Signal request by sensor (option 1) 5
4.6 Signal request by push-button (option 2) 5
4.7 Block diagram 6
Scope of delivery 7
Required tools (not included) 7
Installation 8
7.1 Drilling mounting holes in lighting pole 8
7.2 Opening the signal requesting device 8
7.3 Mounting the bottom part of signal requesting device 9
7.4 Installation of replacement device (hole spacing 80 mm) 10
7.5 Aligning crossing symbol 11
7.6 Replacing crossing symbol 12
Description of the crossing symbols for the visually impaired DIN 32981 12
Mounting the crossing symbol 12
Set-up and function test 13
8.1 Vibration 13
Voltage ranges 13
Settings 13
8.2 Vibrator push-button 14
8.3 Visual feedback (depending on configuration) 15
8.4 Signal request 15
8.5 Speaker (depending on configuration) 16
Accessories 17
Maintenance 18
EU Declaration of Conformity 18
Material defects 19
Quality management 19
Disclaimer/Warranty 19
Contacts 19

3
General information
Caution!
Any person involved in installation, operation and repair of the product must
first read, understand and follow these instructions. We accept no liability for
damage and operating malfunctions caused by failure to comply with these
instructions.
In the interest of further development, we reserve the right to change individual
assemblies and accessories as considered necessary for further safety and
performance improvements, while preserving the main features.
The copyright to these instructions remains with Langmatz GmbH.
Safety information
The product corresponds to the latest state-of-the-art technology at the time of printing
and is delivered in operationally safe condition. No unauthorised modifications may be
made, particularly to safety-related parts.
Langmatz GmbH warns against misuse.
Devices may only be opened by specialist personnel. Before opening a device,
ensure that it is disconnected from the operating voltage.
Operating an open housing carries a risk of contact with live components or cables
and/or conductor paths.
Observe the technical data provided (see chapter 4).
The operating company is responsible for installing, operating and maintaining the
fixtures.
The operator is responsible for the following:
- Preventing danger to life and limb of users and third parties.
- Ensuring safe operation.
- Precluding downtime and environmental impact due to incorrect handling.
- Ensuring that protective clothing is worn when working with or on the
product.
Do not use the product if it is damaged. Please contact the hotline (see chapter 15
Contacts).
Caution!
Applicable occupational safety and environmental protection regulations
must be observed during installation, operation and maintenance or repair.

4
Product description
This manual essentially describes installation and operation of the pedestrian signal
requesting device for pedestrians and the visually impaired provided by Langmatz.
3.1 Dimensions
Fig. 1Fig. 2
Technical data
4.1 General
Designation
basicguide EK524 pedestrian signal requesting
device
Nominal voltages
24 VDC | 40 VAC | 230 VAC
Housing colour
Yellow, similar to RAL 1023, solid coloured,
UV-resistant.
Other colours available on request.
Housing material
Polycarbonate (PC)
Protection class
II
Protection rating
IP54
Housing impact strength
IK10
Energy input
Max. 2.5 Watt
Mounting
2 x M6 x 25 / A2 hexagon socket screws
Lighting-pole adaptor (protection
against vandalism)
Universal, stainless steel
Suitable for: diameters of 78 mm –230 mm
Optionally for: wall installation
Operating temperature
-25 °C to +60 °C
Height / Width / Depth
196 mm / 84 mm / 62 mm / Push-button 64 mm
(distance from pole)
Speaker
300 –20000 Hz / 2 W / 8 Ohm
Device meets the following
standards
DIN VDE 0832 - 100, DIN VDE 0832 - 200
DIN 32981
84
196
62

5
4.2 Tactile signalling device
Designation
Core
Minimum
Maximum
Unit
Neutral conductor, tactile signalling
device
9
Pedestrian crossing signal, tactile
signalling device
1
Voltage range
0.8 Unom
(min. 20 V)
1.2 Unom
(max. 253
V)
Volts
Input power
0.5
1.3
Watts
Nominal voltages
24 VDC / 40 VAC / 230 VAC
4.3 Visual feedback
Designation
Core
Neutral conductor, visual feedback
5
Visual feedback
4
Voltage range
0.8 Unom
(min. 20 V)
1.2 Unom
(max. 253
V)
Volts
Input power per input
0.5
1.2
Watts
Nominal voltages
24 VDC / 40 VAC / 230 VAC
4.4 Signal request by vibrator push-button
Designation
Core
Vibrator push-button
6 / 7
Potential-free switching output
Switching voltage
Max. 250 V AC
Switching current
Max. 2 A
Contact types
NC / NO
4.5 Signal request by sensor (option 1)
Designation
Core
Large-surface sensor
8 / 10
Potential-free switching output
Switching voltage
20-250 V AC / DC
Switching current
Max. 80 mA
Contact types
NO
Bias current
< 1 mA
4.6 Signal request by push-button (option 2)
Designation
Core
Large-surface push-button
8 / 10
Potential-free switching output
Switching voltage
Max. 250 V AC
Switching current
Max. 2 A

6
Contact types
NC / NO
Background colour indicates core colour.
4.7 Block diagram
Fig. 3

7
Scope of delivery
1 1x pedestrian signal requesting device
of type “basicguide”
with connection cable
22x fastening screws
M6x25 (A2)
31x pole seal (flexible)
41x steel lighting-pole adaptor (A2)
(protection against vandalism)
for lighting poles with a
diameter of 78 mm –230 mm
51x drilling template
(self-adhesive paper)
64x crossing symbols
71x special key
Fig. 4
Required tools (not included)
•SW4 Allen key
Fig. 5
1
1
2
3
4
5
6
7

8
Installation
7.1 Drilling mounting holes in lighting pole
Fig. 6
•Remove the protective film from the
drilling template (1).
•Stick the drilling template on the
lighting pole so that the bottom edge
of the template is 850 mm above the
footway.
•Punch-mark 3 drill holes (2).
•Drill 2 holes with a diameter of 5 mm
(3) (for mounting).
•Cut 2 M6 threads (3).
•Drill 1 hole with a diameter of 14 mm
(4) (for the cable duct).
Langmatz recommends using a metal
drilling jig.
Langmatz item no. 700663080.
See also chapter 9 (Accessories)
7.2 Opening the signal requesting device
•On the signal requesting device,
open the 2 locking screws (2) with an
SW4 Allen key and take off the top
part (1) of the device.
Fig. 7
1
850 mm
2
3
4
1
2

9
7.3 Mounting the bottom part of signal requesting device
Fig. 8
Fig. 9
The bottom part (1) of the device is
pre-assembled with the steel lighting-
pole adaptor (protection against
vandalism) (2) and pole seal (flexible)
(3).
•Take off the plastic caps (captive) (2).
•Fasten the bottom part (1) of the device
to the lighting pole with 2 M6x25
fastening screws.
•Note:
- Torque approx. 5 Nm.
- Check that the signal requesting
device fits correctly on the lighting
pole.
•Put on the plastic caps (captive) (2)
again.
Note: Check for correct fit.
(Protection class!)
•Connect the connection cable to the
cable distributor according to the block
diagram in chapter 4.7.
•Unused cores must be insulated.
A function test must be carried out
when the pedestrian signal requesting
device has been installed!
1
2
2
3
1

10
7.4 Installation of replacement device (hole spacing 80 mm)
Fig. 10
Fig. 11
If mounting holes (1) already exist
(thread spacing 80 mm), a
predetermined breaking point (2) can
be opened in the bottom part (3) of the
device.
•Take off the plastic caps (captive) (4).
•Open the predetermined breaking point
(2) and deburr.
•Fasten the bottom part (3) of the device
to the lighting pole with 2 M6x25
fastening screws (5).
•Note:
- Torque approx. 5 Nm.
- Check that the signal requesting
device fits correctly on the lighting
pole.
•Close the upper housing hole with a
sealing plug (1) (colour yellow –
accessories kit).
•Turn the plastic cap (captive) (2) down
and put on to the fastening screw.
Note: Check for correct fit.
(Protection class!)
•Connect the connection cable to the
cable distributor according to the block
diagram in chapter 4.7.
•Unused cores must be insulated.
A function test must be carried out
when the pedestrian signal requesting
device has been installed!
1
3
2
4
80 mm
5
1
2

11
7.5 Aligning crossing symbol
The pedestrian signal requesting device
is factory-fitted with a crossing symbol
(1).
If the specified direction of the crossing
symbol does not match the direction
required, proceed as follows:
Fig. 12
•Insert the special key (1) behind the
crossing symbol and press down.
•The brackets (2) are opened.
Fig. 13
•Press the crossing symbol (2) in
slightly and click it out of place.
•Turn the crossing symbol into the
required direction.
Note: The fitted spring must not fall
out!
•Remove the special key (1).
•Release the crossing symbol and click
it back into place.
Note: Check the built-in seal for
correct fit.
Fig. 14
1
1
2
2
1

12
7.6 Replacing crossing symbol
Description of the crossing symbols for the visually impaired DIN
32981
1Crossing with additional
request
2Crossing only
(factory-fitted)
3Crossing with central island
4Crossing with level crossing
5Crossing in two directions
A more detailed description of the symbols
and their functions is specified in
DIN 32981.
Fig. 15
Mounting the crossing symbol
•Open the brackets (2) with the special
key (1) (as described in chapter 7.5).
•Press the crossing symbol (3) in slightly
and click it out of place.
•Pull the crossing symbol out completely
downwards.
Note: The crossing symbol is spring
loaded. Catch the spring when pulling
out!
Fig. 16
•Insert the new crossing symbol (2).
•Turn the crossing symbol into the
required direction.
Note: The fitted spring must not fall
out!
•Remove the special key (1).
•Release the crossing symbol and click
it back into place.
Note: Check the built-in seal (3) for
correct fit.
•Close the device again.
Fig. 17
1
2
3
4
5
2
1
3
1
2
3

13
Set-up and function test
8.1 Vibration
The vibrator (tactile signalling device) is connected to the corresponding crossing
orientation signal of the traffic light system and can be operated with a voltage of 20 V DC
to 253 V AC.
The voltage range is set with a DIP switch.
This ensures that the vibration can only be activated with the set voltage range.
Voltage ranges
DIP switch, 5-pole (1)
Only change the switch positions in a
de-energised state.
Fig. 18
24 V nominal voltage (18 to 30 V DC)
40 V nominal voltage (30 to 50 V DC)
230 V nominal voltage (170 to 253 V AC)
40 V dimming nominal voltage (18 to 50 V AC / DC)
230 V dimming nominal voltage (110 to 253 V AC)
Settings
The voltage range is set on 230 V on delivery.
1

14
Operating voltages
Switch
position
230
V
40 V
24 V
DC
230 V
dim.
40 V
dim.
1
OFF
OFF
ON
OFF
OFF
2
OFF
ON
OFF
OFF
ON
3
OFF
OFF
OFF
ON
ON
Fig. 19
The vibrator clock rate can be set to
the clock rate of the pedestrian
crossing signal with switch position 4
and 5.
The clock rate is set to 2 Hz on
delivery.
Vibrator clock rate
Switch
position
1 Hz
2 Hz
4 Hz
6 Hz
4
ON
OFF
OFF
ON
5
ON
OFF
ON
OFF
Fig. 20
8.2 Vibrator push-button
Important:
When the mounting work has been
finished, check that the vibrator push-
button works correctly with the crossing
symbol (1)!
- Possibility to request a signal in all
positions of the vibrator push-button.
- Clearly noticeable vibration at the
crossing symbol during signalling of
crossing possible.
Fig. 21
1

15
8.3 Visual feedback (depending on configuration)
DIP switch
Visual feedback (1)
The voltage range is set to 230 V
and constant light on delivery.
Fig. 22
Switch
position
230 V
40 V
24 V
1
ON/OFF
ON/OFF
ON/OFF
2
ON/OFF
ON/OFF
ON/OFF
3
-
-
-
4
OFF
ON
ON
Fig. 23
8.4 Signal request
•Test signal-request function by
pressing the large-surface push-button
(1).
Optionally with sensor:
•Test signal-request function by
touching the sensor surface (1).
Fig. 24
Switch position 1 → on = flashing 2 Hz
→ off = flashing 1 Hz
Switch position 2 → on = flashing
→ off = constant light
Switch position 3 → not used
Switch position 4 → on at 24 and
40 Volt
→ off at 230 Volt (Inrush
current limiter)
1
1

16
8.5 Speaker (depending on configuration)
The speaker is available for an
external acoustic device.
The function test depends on the type
of acoustics used.
Technical data of the speaker:
300-20000 Hz | 2 Watt | 8 Ohm
Fig. 25
Note:
If one or more of the above-mentioned settings do not work correctly, check the
devices settings and connection configuration.

17
Accessories
Designation
Langmatz item no.
Example illustration of the
product
Drilling jig
700663080
Vandal guard
Available in various colours
and with various pictograms
on customer request
700663090

18
Maintenance
EU Declaration of Conformity
The product meets the requirements of the following applicable harmonisation
directives:
2014/30/EU Electromagnetic Compatibility (EMC)
2014/35/EU Low Voltage Directive (LVD)
The following standards were complied with:
EN 50293:2012 (EMC)
EN 50556:2011 (LVD)
DIN 32981:2018-06
The EU Declaration of Conformity for this product can be requested from Langmatz
GmbH.
Measures
Intervals
Remarks
External visual
inspection
At least every 12
months or during
maintenance
measures on the
complete
installation.
Check the device for external dirt and
damage.
Note: Do not use abrasive cleaning
agents or solvents to clean the
housing.
Check crossing
symbol
Check correct alignment and
corresponding crossing symbol.
Carry out complete
function test
If the device is defective, send it in to
Langmatz GmbH with a description of
the fault.
Langmatz GmbH senden.

19
Material defects
Langmatz shall assume liability for material defects in the product as per Section 434
BGB (German Civil Code) for 24 months, starting from the date on the purchase
receipt.
Within the scope of liability, all parts that become damaged due to manufacturing or
material errors shall be replaced or repaired free of charge.
The purchaser must report any deficiency complaints immediately in writing.
Claims for damages by the purchaser due to material defects or whatever legal
reason shall not be accepted.
Any damage or failure caused by the following are also excluded from liability:
- incorrect use,
- natural wear and tear,
- intervention by third parties.
We accept no liability for damage caused by force majeure or transport.
Repairs due to a deficiency complaint shall not extend the warranty period for the
replaced parts or the product.
This product corresponds to the latest state-of-the-art technology. Nevertheless, if you
experience any problems with it, please contact our hotline (see chapter 15 Contacts).
Quality management
Langmatz GmbH’s quality management system is certified to DIN EN ISO 9001.
Disclaimer/Warranty
The information in this technical document is presented appropriately and correctly
according to technical regulations and to the best of our knowledge. However, this
does not confer any guarantee of particular characteristics. The operator of the
products supplied by Langmatz GmbH is expressly obliged in this context to decide,
based on his/her own judgement, whether the products are suitable and appropriate
for the application or use being considered. The product liability accepted by
Langmatz GmbH relates exclusively to our conditions of sale, delivery and payment.
Langmatz GmbH accepts no liability due to random, indirect and resultant
consequential damage, as well as any damage attributable to any use of the product
other than for its described and intended purpose.
Contacts
Langmatz GmbH | Am Gschwend 10
82467 Garmisch-Partenkirchen, Germany
Our hotline: +49 88 21 920 137
Telephone: +49 88 21 920 0

20
12 524 0960 / 000 │ As of 18.11.2019 │ Original Operating Instructions