1. Overview
2. Considerations and Safety Maintenance
Please read the instruction for use carefully in order to ensure correct
measurement result:
1
8
1. Overview
2. Considerations and Safety Maintenance
3. Performance index
4. Product Description
4.1. Instruction to structure
4.2. Key Description
4.3. Key Description
5. Initial Operation
6. Introduction to “image” sub-menu
6.1. View image
6.2. Delete images
7. Introduction to “color palette” sub-menu
7.1 Color Palette Description
7.2 Application of color palette
8. Introduction to “emissivity” sub-menu
8.1 Emissivity Description
8.2. Emissivity setting
8.3 The Emissivity Value of Common Materials
9. Introduction to “Setting” Sub-menu
9.1 Time Setting
9.2. Enable/disable of the highest and lowest temperature cursor
This product is an inferred camera that integrates surface temperature
measurement and real-time thermal image. The traditional inferred
thermometer needs to measure every component one by one while it is not
necessary for infrared imaging camera, thus saving time. The potential
problems may be displayed on color display screen clearly. Moreover, the
central point measurement cursor is used to locate quickly and accurately to
measure the temperature of the target object.
In order to increase the differentiation, the product is provided with a visible
light camera. The thermal images and visible images are stored in the
device and can be read through USB or stored in a computer to generate a
report or for print. The supported operating system through verification
includes: win XP, win7, win 8, win10, Apple system. It is suggested to use
the attached USB cable or USB cable with higher quality.
The product can be used in fields of medical treatment, fire fighting,
archaeology, traffic, agriculture, geology, energy, smelting, electronic
manufacture, etc and is the ideal selection for electrician and maintenance
personnel and technicians and can be used to find the problem area quickly.
The following major functions increase the product’s accuracy and usability:
The radiation coefficient may be adjusted to increase the measurement
accuracy of objects with half reflection surface.
The highest temperature and lowest temperature cursor may guide the
users to the areas with highest and lowest temperature of the thermal
images.
The selectable color palette.
Don’t use the device in explosive, flammable or corrosive environment.
The product belongs to precision electronic and sensitive optical devices.
Don’t impact and drop it to avoid damage.
Don’t dismantle and remodel the products.
When the product works, there is light sound of clicking every several
seconds. This is normal phenomenon that the lens captures images.
Please use damp cloth or weak soap to clean the enclosure of the device.
Don’t use abradant, isopropanol or solvent to clean. Special optical lens
cleaner is used to clean the screen.
Contents

3. Performance index 4. Product Description
4.1. Instruction to structure
23
Visible light camera
Infrared imaging
sensor
Image capture key
Display Pixels
Infrared image resolution
visible image resolution
Field angle/shortest focus length
Thermal sensitivity
Temperature measurement range
Accuracy(-20℃~450℃)
Accuracy(300℃~450℃)
Emissivity
Frame rate of thermal images
Wavelength coverage
Focus mode
Color palette
View option
Storage medium
File format
Automatic power-off time
USB
Power supply
Product size(length × width × height)
Product weight
Work temperature
Storage temperature
Relative humidity
320x240
Display screen
Screen size
TFT display screen
3.2 inches
220x160
300,000
27°x35°/0.5m
0.07℃
-20℃to 450℃(-4°F to 842°F)
±2%
±10%
Adjustable from 0.01 to 1.0
9Hz
8-14um
Fixed
Rainbow, iron oxide red, cold color,
black & white, white & black
The integration of thermal image with
25% step length and visible image.
Built-in 3G
JPG
Built-in chargeable 18650 battery
Micro USB 2.0
Selectable: 5 minutes/20 minutes/
not power off automatically
90mm×105mm×223mm
389g
0℃to 45℃
-40℃to 60℃
< 85%RH
Micro USB

4.2. Key Description
Maximum value/
minimum value of
field temperature
5. Initial Operation
4.3. Key Description
On/off key
Menu key
Entry key
Selection key
Navigation key: Up, down, left and right
45
Color code
Current emissivity
Battery power
The highest
temperature cursor
Temperature
cursor at
central point
Time
Central point
temperature
The lowest
temperature cursor
Color code: used to mark the color corresponding to the relative temperature
from low to high in the field of version.
The central point temperature cursor: used to indicate the central position in
the screen area. The cursor color displays white. The temperature value is
displayed top left corner of the screen.
The highest temperature cursor: used to indicate the highest temperature
position in the screen area. It will move with the movement of the highest
temperature. The cursor displays red. The temperature value is displayed at
bottom left corner of the screen.
The lowest temperature cursor: used to indicate the lowest temperature
position in the screen area. It will move with the movement of the lowest
temperature. The cursor displays red. The temperature value is displayed at
the central position of the screen.
5.1 Charging: the product is provided with built-in 18650 lithium battery.
When the battery power is not sufficient, please charge it through Micro
USB interface in time.
5.2 On/off key: hold down “ ” key to power on /off.
5.3 Switching between infrared thermal image and visible image: press
“ ” or “ ” key to switch the degree of fusion between inferred thermal
images and visible images (the degree of fusion is 0%, 25%, 50%, 75% and
100%).
5.4 Image capture: press the image capture key. When the capture is
successful, the screen will display “store photo?” prompt. If “yes” is selected,
please press “MENU” key to determine to save the image. If “no” is
selected, press “SELECT” key to determine not to save the image.
5.5 The function to hide highest/lowest temperature column at the screen
bottom: under the operation after normal start up, press “ ” key and the
screen bottom will display highest/lowest temperature column. Press “ ”
can also hide it.
5.6 Image output: The saved images through capture may be checked and
output by connecting with a computer through Micro USB.

6. Introduction to “image” sub-menu 7. Introduction to “color palette” sub-menu
The following is the image of the same object with selection of different
color palettes.
6 7
7.1 Color Palette Description
6.1. View image
171229-105030
171229-105031
171229-105032
171229-105033
Iron oxide redRainbow Cold color
White heat Black heat
6.2. Delete images
As shown in the figure, press “MENU” key to select “image” option in the main
menu. Then press “ ” key to enter image list. Press “ ”or “ ” key
in navigation to select the image. Then press “SELECT” key to view image.
When viewing the images, press “ ” key to view the precious image.
Press “ ” to view the next image. Press “ENTER” key to return. Press
“MENU ” key to exit from the menu.
When viewing the images, the screen will show the prompt of “Delete
photo?” by pressing “ ” key. If “yes” is selected at the moment,
press “MENU” key to determine to delete the image. If “no” is selected,
press “SELECT” key to determine not to delete the image.
The menu of color palette can change the false color of infrared thermal
image. The product provides five types of color palette: rainbow, iron oxide
red, cold color, black white heat and black heat.
Suitable selection of color palette displays the details of the target objective
better. Rainbow, iron oxide red and cold color palettes focus on display of
color. Such color palettes are very suitable for high heat contrast and are
used to improve the color contrast between high temperature and low
temperature. But the black & white and white & black color palettes provide
even linear color.

The operating step is as the following:
9
8.2. Emissivity setting
Matt (e=0.95)
Emissivity
Semi-matt (e=0.85)
Semi-glossy (e=0.60)
Glossy (e=0.30)
Custom
0.01
8. Introduction to “emissivity” sub-menu
7.2 Application of color palette
8.1 Emissivity Description
Spectra
Iron
Cool
White
Black
Color palette
8
As shown in the figure, press “MENU”
key to enter the main menu and select
“color palette” option and press “ ”
key to enter the color palette list. Press
“ ” and “ ” keys in navigation to
select the color palette. Then press
“SELECT” key to select the color palette.
Press “ ” to return. Press “MENU”
key to exit from the menu.
The emissivity of the product can be adjusted from 0.01 to 1.00 with the default
value of 0.95. Many common objects and materials (such as timber, water, skin
and textile fabric) can reflect the heat energy effectively. So it is easy to obtain
relatively correct measurement value. The emissivity is usually set as 0.95
when the coarse objects that are easy to give out energy. For semi-matte
objects that give out less energy, the emissivity is usually about 0.85 and the
emissivity of semi-gloss objects is 0.6. The shiny objects are divided into
materials with low radiation coefficient. The emissivity is usually set as 0.3 at
the time of measurement. Correct setting of the value of emissivity is very
important for you to carry out the most correct temperature measurement. The
surface emissivity will produce giant impact on surface temperature measured
by the product. Understanding the surface emissivity will enable you to obtain
correct temperature measurement result.
The product is provided with four types of object measurement modes:
Coarse object (0.95)
Semi-matte object (0.85)
Semi-shiny object (0.60)
Shiny object (0.30)
According to the characteristics of the measured objects, users may set the
emissivity value through the “self-define” option (please refer to the table of
“emissivity of common materials”).
As shown in the figure, press “MENU” key to enter the main menu and
select “emissivity” option and press “ ” key to enter the emissivity list.
Press “ ” and “ ” keys in navigation key to select the emissivity. Then
press “SELECT” key to determine selection of the emissivity. Press “ ”
key again to return.
If to select “self-defined” emissivity, please press “SELECT” key to enter
the edit state. Press “ ” and “ ” keys to select the number to be
changed. After the change is completed, press “ENTER” key to enter.
Then press “ ” and “ ” keys to change the value. Press“MENU” key
to exit from the menu.

9. Introduction to “Setting” Sub-menu
Settings
Auto shutdown Auto
shutdown
Intensity
Language
Unit
Time Format
Year
Month
Day
Hour
Minute
Second
2017
12
28
15
15
15
Set time
Spot
Version
Off
On
HT-18
V2.2.3
24 hour
AM/PM
English
Chinese
Celsius
Fahrenheit
NO
5min
20min
Low
Medium
Hight
Intensity
Language
Unit
Time format
Set time
Spot
Version
24h
10
8.3 The Emissivity Value of Common Materials
Thermal radiation
Black cloth
Human skin
Foam
Charcoal dust
Paint
Matte paint
Black rubber
Plastic
Timber
Paper
Chromium
hemitrioxide
Copper oxide
Ferric oxide
Textile
11
Substance Thermal radiation
Substance
Bitumen
Concrete
Cement
Sand
Earth
Water
Ice
Snow
Glass
Ceramics
Marble
Gypsum
Mortar
Brick
Press “MENU” key to select the “setting” option in the main menu.
Press “ ” key again to enter the “setting” sub-menu.

9.2. Enable/disable of the highest and lowest
temperature cursor
13
12
9.1 Time Setting
Spot
Off
On
24h
Year
Month
Day
Hour
Minute
2016
9
9
11
33
Second
33
Set time
24h
Press “ ”/“ ” to select year/
month/day/hour/minute.
After selecting, press “SELECT”
key to enter the edit state.
Press“ ” and “ ” keys to
select the figure to be changed.
Press“ ” /“ ” key to change
the value. After completing the
change, press “SELECT/ENTEER”
to enter.
After the time setting is completed,
press “ ” key to return. Press
“MENU” exit from the menu.
As shown in the figure, after entering the “setting” sub-menu,
select the cursor point (spot). Press “ ” key in the
navigation key to enter cursor point (spot) setting.
Press “ ” /“ ” key to select
“enable” or “disable” the option
Then press “SELECT” key to
determine selection
After the setting is completed,
press “ ” key to return. Press
“MENU” key to exit from the menu
Table of contents