LifeSafety Power PROWIRE RGA150B-D8Z/T8-A User manual

July 2022 1/2 www.lifesafetypower.com
AMAG 8DR Rack
PROWIRE
®
Overview
These ProWire Unified Power rack mount models are single and dual voltage access power systems, precision wired for M2150 or M4000 Series AMAG controllers.
ProWire enables the specification and installation of standardized access power equipment across an enterprise for uniform operation, maintenance and servicing.
The F8 egress output module provides eight outputs selectable for constant output, enable on FAI, or disable on FAI. Each output is selectable for either 12 or 24V in dual
voltage systems.
The D8 provides eight auxiliary outputs, individually selectable for 12 or 24V in dual voltage systems.
ProWire Unified Power rack drawers are painted steel with removable backplate, lock, keys and and tamper switch and come 100% factory tested – ready for
final panel installation and field wire termination.
Product Features Rack Drawer
Guarantees uniform installations across an enterprise
Pre-installed wire harness for panel power, FAI drop,
faults and tamper switch
Point to point wiring; labeled, color coded, twisted pair,
shielded communication
Tie wrap cable management
Managed systems monitor power and batteries
UL294, ULC S319 listing
Model Nomenclature
*Model Number Model Wiring Options System Type Distributed Outputs Enclosure / Cable Mgmt
T8-A T8-C Auxiliary and Control H x W x D (inches)
Dual Voltage - 4A/12V and 4A/24V
RGA150B-D8Z/T8-A T8-A T8-C Standard 8 Auxiliary R2U
19" rack drawer
Tie Wrap
RGA150B-F8Z/T8-A T8-A T8-C Standard 8 FAI drop
Single Voltage - 12A/12V (6A/24V)
RGA150-D8Z/T8-A T8-A T8-C Standard 8 auxiliary
R2U
19" rack drawer
Tie Wrap
RGA150-D8NZ/T8-A T8-A T8-C Networked 8 auxiliary
RGA150-F8NZ/T8-A T8-A T8-C Networked 8 FAI drop
*Model wiring option "T8-A" calls out A wired tie wrap. Modify model number to order other options, i.e., RGA150B-F8Z/T8-C (C wired tie wrap)
Power Supplies Accessory Boards Wiring Option
RGA150
Cable mgmt
Networked
F8 NZ T8-A
/
T Tie Wrap 8DR
A 8DBC
C M4000
B–
Power rating
FPO150 4A/24V 100W lock power
B100 4A/12V 50W system power Accessories
D8, F8, NL2
4DC (X2)8DBC
B
8DBC
A
M4000
C

July 2022 2/2 www.lifesafetypower.com
LSP PROWIRE | AMAG 8DR RACKMOUNT
System Specifications
Power Supplies FPO150 Power supply board, 4A/24V
B100 Secondard voltage module, 4A/12V class 2 power limited
Input 120/230VAC 50/60Hz | 83 Watts (0.69A)
Overload and short circuit protection
Over temperature protection
Polarized AC power supply disconnect
Battery Charging Independent built-in charger for sealed lead-acid or gel type batteries
Microprocessor dual rate charging of 12 or 24V battery sets
Automatic switchover to standby battery when AC fails
Zero voltage drop when switched over to battery backup
Supervision AC Fault (form "C" contacts)
System Fault (form "C" contacts)
System Fault conditions: Low or no battery | short to earth ground | power supply failure
Distribution Modules D8 8 auxiliary outputs, fused at 3A per output
F8 8 egress outputs, fused at 3A per output
Network Management NL2 Two port module. Monitors and reports power supply status. Tests and reports battery health status.
Enclosures RGA 2U rack mount (19.00"W x 3.50"H x 20.50"D) | Weight 24 lbs. | Z bracket wire management articulating arm
Wiring Suffix T8-A T= Tie Wrap 8= Door count A= M2150
T8-C T= Tie Wrap 8= Door count C= M4000
Regulatory Compliance UL / ULC UL294, ULC S319
CSA / FCC CSA C22.2 #107.1 | FCC Part 15, CSFM
System Examples
4DC (X2)8DBC
B
8DBC
A
M4000
C
LifeSafety Power
10027 S. 51st Street, Suite 102
Phoenix, AZ 85044 USA
PH 888-577-2898
info@lifesafetypower.com
P01-1024A07/22
LifeSafety Power warrants to the original purchaser only that all products will be free from defects in material or workmanship at time of shipment. This warranty is
non-transferable. Our obligation under this warranty is limited to repair or replacement, at the sole discretion of LifeSafety Power, of products that are defective in
material or workmanship at the time of shipment provided they were used within the specified ratings and installed in accordance with accepted engineering practices.
Products in the Unified Wired Systems Classification will be wired to the LifeSafety Power description of operation unless otherwise stated. At the time of installation it
is the obligation of the purchaser or final installer to verify that all wired terminations provide the desired operation. In no event shall LifeSafety Power be responsible for
any special, incidental or consequential damages even if LifeSafety Power has been advised of the possibility of such damages. Customer hereby agrees to indemnify
LifeSafety Power for and hold LifeSafety Power harmless from and against any and all loss, cost or expense (including reasonable attorneys’ fees) directly or indirectly
related to any claim with respect to Unified Wired™ systems classification products except to the extent any such claim shall result from the gross negligence or willful
misconduct of LifeSafety Power.
This manual suits for next models
4