Safety instructions and precautions
• Never look directly into the beam or shine in anyone’s eyes.
• Do not block the ventilation inlet or outlets on the unit.
• Ensure that there is sufcient ventilation around the unit, recommended minimum 1m².
• This product is designed for indoor use only and should not come into contact with water or excessive
dust.
• No user serviceable parts inside.
• Use only approved accessories.
• Do not use this device in the presence of ammable or oxygen rich atmospheres.
• To prevent injury, this apparatus must be securely attached to the ceiling/wall.
Installation
Prior to mounting the unit please refer to the distance/spot size charts below to achieve the required
image size.
Fix the projector to the bracket by inserting the screw thread on the top of the bracket into the projector
and screwing in place until tight.
Distance Diameter
4m
3m
2m
1m 0.44m
0.89m
1.33m
1.77m
25°
Narrow Lens Wide Angle Lens
Distance Diameter
4m
3m
2m
1m 0.30m
0.60m
0.90m
1.20m
17°
Light Projects 23 Jacob St London SE1 2BG Tel +44 (0)20 7231 8282
Website www.lightprojects.co.uk Email info@lightprojects.co.uk
Constant Current
pg 1
EVICA EP40 CONTANT CURRENT LED EFFECTS PROJECTOR

1.
6.
2.
5.
3.
Operation
1. Gobo projector only: Remove Gobo cassette by
unscrewing 2 socket head screws in the side of the
projector. Place the gobo slide into recessed pocket in the
cassette and hold in place with the gobo retaining ring. Gobo
image should be upside down and back to front.
2. Slide the cassette into the slot in the side of the projector
and x side screws.
3. Connect power as detailed above.
4a. Framing projector only: Insert the shutter blades into the
gap behind the cassette and position as detailed on next page.
4b. Gobo projector only: Rotate cassette ring to orientate
image as required.
5. Focus the projected image by rotating the objective lens
bezel. The lens may also be coarsely positioned by simply
pulling the lens to the desired position and then twisted to
provide ne focus.
6. To reposition the projector, loosen the buttery screw,
position as desired and tighten the buttery screw to x into
position.
4.
Connect to Constant CurrentPower supply.
Remote Constant Current versions are tted with a 4 core cable to provide 12Vdc 0.6W(min) xed supply
to power Fan and 900mA 43.2 Vdc (min) variable supply to power LED.
Before maintenance or installation, ensure power is disconnected from the Driver or Lighting Track.
Check labelling on Projector and Driver for correct terminals.
Projector LED +ve (White) to Driver CC LED +ve Projector LED -ve (Black) to Driver CC LED -ve
Projector FAN +ve (Brown) to Driver AUX 12Vdc +ve Projector FAN -ve (Blue) to Driver 12Vdc AUX -ve
For Remote versions: Projector is tted with long 4 way cable which is connected directly to Driver.
For Ceiling Mount versions: projector is tted with a short cable with plug together terminal block in top of
Ceiling Mount. Connect terminals to Driver using separate 4 core cable (by others) see Driver for Cable
details.
Projector MUST ONLY be operated WITH the 12V FAN supply permanently connected.
Ensure that all wires are connected and any plugs and sockets between Projector and Driver are fully mated.
Connect Mains supply to Driver, switch on supply and check Fan is operating. SWITCH OFF if fan fails to
operate.
Dimmable drivers will operate at full output in the absence of the control connection. Having established
correct operation without the control connection, connect the controller following it’s instructions (by other)
and check for correct dimming function.
Constant Current
Light Projects 23 Jacob St London SE1 2BG Tel +44 (0)20 7231 8282
Website www.lightprojects.co.uk Email info@lightprojects.co.uk pg 2

Firstly if the object to light doesn’t fall
within the circle of the open beam as
gue 1 illustrates, then the projector
will need to be mounted further away
from the object so beam fully covers
object as shown in gure 2.
Figure 3 shows cassette removed from projector for clarity.
Figure 4:
1. Place I shaped blade (1) onto cassette next to the xing screw side.
2. Place T shaped blade (2) onto cassette on opposite open side.
Figure 5:
3. Place the remaining 2no T blades (3) and (4) onto cassette, on top of
blades (1) and (2).
To frame object:
1. Pull blades out of beam, leaving just one in the beam.
2. Adjust lens position to focus on the edge of the blade. For coarse
adjustment, push lens out/in from projector. For ne adjustment, rotate
lens.
3. When lens focus position is found, push all the blades out, leaving just
the edges touching the beam circle.
4. Adjust projector orientation to centre beam on lit object.
5. Starting with blade (1), move blade to cut edge of beam as desired.
6. When viewing from behind the projector with blade (1) on right hand
side, the change on the beam will be on the left hand side.
7. Similarly, blade (2) on left, will be visible on right side of beam.
8. (3) At top, visible on the bottom
9. (4) At bottom, visible on the top
10. Moving side blades (1) and (2) may move blades (3) and (4) as well, so
set (1) and (2) rst and then (3) and (4).
1
1
2
2
4
3
Framing Objects with Shutter
1
3
4
2
Figure 6 shows where the blades will
effect the framing on the object.
Figure 3
Figure 1 Figure 2
Figure 4
Figure 5 Figure 6
Constant Current
Light Projects 23 Jacob St London SE1 2BG Tel +44 (0)20 7231 8282
Website www.lightprojects.co.uk Email info@lightprojects.co.uk pg 3

Cleaning and Maintenance
Periodically clean the projection lens with a lint free cloth and a small amount of glass cleaner if neces-
sary.
Check that the ventilation inlet and outlets are free from dust or blockages, clean with a vacuum cleaner
nozzle if necessary.
Notice
The information contained within this document is subject to change without notice.
Light Projects Ltd makes no warranty of any kind with regard to this material, including, but not limited
to, the implied warranties of merchantability and tness for a particular purpose.
Light Projects Ltd shall not be liable for errors contained herein or for incidental or consequential dam-
ages in
connection with the furnishing, performance, or use of this material.
No part of the document may be photocopied, reproduced, or translated to another language without
prior written consent of Light Projects Ltd.
Service
Guarantee
The Evica product range is provided with a 3 year guarantee against manufacturing and material defects
when installed according to the product specication and used under recommended working conditions.
Full details available on request.
Limits of the guarantee: At its sole discretion, Light Projects Ltd agrees to repair or replace products
deemed by Light Projects Ltd to be defective. Light Projects Ltd reserves the right to replace a product
with a like replacement that fulls the same purpose. This replacement product may have graphics or
nishing different from the original.
It is the product users responsibility to examine the product on a regular basis to determine the need for
servicing and or a replacement.
Products that have been neglected, modied or poorly maintained are not covered under the guarantee.
Damage from causes other than defects in materials and workmanship (e.g. lack of experience, ability or
competence) are not covered under the guarantee.
The nish or aesthetics of Light Projects Ltd products are not covered under the guarantee.
Any labour or postage costs associated with the removal, replacement or reassembly of the product are
not covered under the guarantee.
Normal wear and tear and maintenance are not covered under the guarantee
Constant Current
Light Projects 23 Jacob St London SE1 2BG Tel +44 (0)20 7231 8282
Website www.lightprojects.co.uk Email info@lightprojects.co.uk pg 4

Additional instructions for Evica EP40 Effects Projector Remote Dimmable 0-10V Models.
The internal LED driver is dimmable by use of a remote Current Source or Sink 0-10V Dimmer.
Projector is tted with an additional 2 core cable with jack plug to connect to the dimmer
Red Core = +ve output of Dimmer
Black Core = -ve coutput of Dimmer
Follow general instructions for installation of Projector.
Connect Dimming wires, which are connected to the black marked terminal block, to Remote 0-10V
dimmer.
Connect:
Black to Black (-) -ve 0-10V
Red to Red (+) +ve 0-10V
Connect Low Voltage 24Vdc power supply to white terminal block.
Connect:
Black to Black (-)
Red to White (+)
Attach EP40 projector to Ceiling Mount Ball Joint.
Plug 24V & 0-10V leads from ceiling mount into back of EP40 projectors.
If 0-10V signal is diconnected, the LED with come on at full output.
With dimmer connected, adjust dimmer to achieve desired intensity.
Rev: 20.12
Constant Current
Light Projects 23 Jacob St London SE1 2BG Tel +44 (0)20 7231 8282
Website www.lightprojects.co.uk Email info@lightprojects.co.uk pg 5