LINDR 022-2021 User manual

FLOW-THROUGH COOLER
LINDR
Number 022-2021 REV00 Valid 2021-02-01
INSTRUCTION MANUAL
ENGLISH
AS-40 GLYKOL GREEN LINE

2
IMPORTANT
his manual contains instructions for installation, use and operation of the
appliance. This manual is an integral part of the device. It must be stored in the
vicinity of the device for the entirety of its service life and must be made avai-
lable to the user any time the device is installed, moved, used or maintained.
Read this manual carefully before installing and using the device. It contains
important information necessary to ensure that all operations are done pro-
perly and safely.
Due to continuous product improvement, the images placed in the manual are
illustrative only and may dier from the purchased goods.
WARNING:
Not following instructions may cause injury or
damage the device.
SYMBOLS AND MARKINGS USED IN THE MANUAL:
DANGER:
Risk of injury by electrical current.
NOTE:
his symbol indicates information and re-
commendations for the user.
WARNING:
The cooling system contains ammable coolant
R290 (propane)!
LINDR.CZ s.r.o.
Sadová 132
503 15 Nechanice, Czech Republic
mob.: + 420 775 715 494
tel. : +420 495 447 239
e-mail: info@lindr.cz
web: www.lindr.cz, www.lindr.eu
is manual is a translation of the original Czech manual.

AS - 40 Glykol
3
Contents:
1. Introduction
2. Description of the cooler
3. Machine plate
4. General instructions, measures and safety instructions
5. Installation and placement
6. Electrical connection
7. Testing
8. Warranty
9. Description of the device
10. Filling the cooler tank and connection with beer tank
11. Putting into operation
12. How to work with speed ttings
13. Thermostat STC 200, Dixell XR20CX
14. Inspection before every use
15. Periodic checks
16. Maintenance
17. Environmental protection
18. Table of malfunctions
19. Spare parts
20. Technical data
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
..................................
4
4
4
4
5
5
6
6
6
7
8
8
9
9
9
10
10
10
11
11

4
1. INTRODUCTION:
Thank you for purchasing this LINDR product.
2. DESCRIPTION OF THE COOLER:
AS-40 GLYKOL GREEN LINE:
Professional cooling system designed for
applications where cooling to temperatures
below freezing is required. The cooler is equi-
pped with a digital thermostat with a mini-
mum temperature setting of up to -6 ° C. The
cooling unit is equipped with a powerful pump
with a displacement of 6 m. The modern Lindr
cooling technology uses the input energy for
direct conversion to cold and guarantees mi-
nimum energy consumption.
3. MACHINE PLATE:
4. GENERAL INSTRUCTIONS, MEASURES
AND SAFETY INSTRUCTIONS:
When using the device, follow basic safety
instructions stated by the manufacturer. The
device is designed for ow-through cooling of
coolant for technological processes. Any other
use is considered impermissible and therefore
dangerous. The supplier is not liable for dam-
age caused by incorrect use.
DO NOT USE THE DEVICE FOR PURPOSES
OTHER THAN THOSE STATED BY THE MANU-
FACTURER!
General safety principles. Observe the fo-
llowing safety instruction.
The supplier is not liable for damage caused
by activities carried out on this device without
observing the following instructions!
WARNING: Children must not be allowed
to play with the appliance. Store all packaging
material out of reach of children (comes with a
plastic bag – suocation hazard).
WARNING: Cleaning and maintenance of
the appliance by the user must not be done by
unsupervised children.
WARNING: Before connecting to main
electrical supply, check that the voltage and
frequency in the mains corresponds to the
data stated on the device.
WARNING: Always make sure the power
socket the cooler is plugged into meets the
specications on the machine plate (voltage,
frequency, input power).
WARNING: Before any interference with
the device, such as cleaning or maintenance,
ALWAYS disconnect the device from power
supply: set the switch to the „O“ position and
unplug the appliance from the socket
WARNING: Never place tools or other ob-
ject into the fan
WARNING: Never touch electrical compo-
nents with wet or damp hands.
WARNING: To ensure the cooling unit
works properly and at full capacity, make sure
air supply to the unit is not obstructed.
WARNING: Always make sure the power
socket you intend to plug the cooler into is ac-
cessible, so that the appliance can be imme-
diately unplugged in case of emergency.

AS - 40 Glykol
5
WARNING: When unplugging the device
from the socket, grab the plug and pull it out.
Do not under any circumstances pull at the
cable; risk of damage.
WARNING: To turn the device o comple-
tely, unplug the appliance from the power soc-
ket.
WARNING: : In the event the electrical wi-
ring of the product becomes damaged, sum-
mon a trained service technician. Do not under
any circumstances repair the device yourself.
WARNING: The cooling system contains
ammable coolant R290 (propane)!
WARNING: Emergency maintenance and
repair of the cooling system must be done by
trained, authorised technicians familiar with
cooling and electrical systems. The technicians
should have special training and qualication
for handling ammable substances in order to
perform service on coolers containing R290.
Follow basic regulations and safety measures
regarding service and repair!
WARNING: Do not use open ame or po-
tential sources of sparks in the vicinity of a
cooler using R290 coolant!
WARNING: After unpacking, place the coo-
ler so that heat created by the cooling unit can
be vented suciently.
WARNING: Do not place objects that could
prevent air circulation on top of the cooler.
5. INSTALLATION AND PLACEMENT:
Place the cooler onto a stable, level surface
(maximum permitted inclination: 2 degrees).
The appliance requires unobstructed air circu-
lation.
• Ensure sucient free space for air circulation
and heat dissipation.
• Ensure sucient supply of fresh air.
• The device must not be placed in an enclo-
sed space.
• The device must not be placed in the vicinity
of heat sources or exposed to direct sunlight.
The minimum distance from obstacles vents
must be 200 mm and 500 mm from the con-
denser. In the place where there are no venti-
lation holes, the minimum distance is 70 mm.
It is best to use the machine in a cool and well-
-ventilated room. The machine is intended for
use at an ambient temperature of min. 16 ° C
and max. 32 ° C.
WARNING: The device MUST NOT be used
or stored at ambient temperature lower than
0 °C. The device is designed for use in a normal
environment, always indoors, protected from
rain or sunlight. Climate class N.
DANGER: Protect the cooler and the
electrical connection from rain and spraying
water!
WARNING: Do not under any circumstan-
ces lay the cooler on its side, not even during
transport.
6. ELECTRICAL CONNECTION:
onnect the device to a power socket in accor-
dance with specications on the machine pla-
te of the device. Electrical wiring is subject to
local regulations. If the power leads (cables)
are damaged, they must be replaced by the
manufacturer, their service technician or a si-
milarly qualied person to prevent risk of ha-
zardous situations
DANGER: Do not use or turn on the device
if the power lead (cable) is damaged!
NOTE: In order for the device to work
correctly and at maximum output, it is im-
portant to not cover up any of the device‘s
vents and ensure sucient air circulation.

6
7. TESTING:
The product is delivered ready for immediate
use.
8. WARRANTY:
The device comes with a warranty in accor-
dance with general legal regulations of the
Czech Republic or in accordance with the tra-
de agreement. During the validity period of
the warranty, we will remove any defects on
the product free of charge, provided these
defects were not caused by excess wear, im-
proper handling, incorrect storage or by using
the product in a way that is counter to the in-
struction manual or the product‘s design as
dened by the manufacturer. Materials repla-
ced during the validity period of the warranty
are our property. The legitimacy of the warran-
ty claim is always decided by an authorised
service centre. Warranty provided by a retailer
outside of the territory of the Czech Republic
is governed by the agreement between the
retailer and the buyer in their mutual relation-
ship; this agreement is not directly linked to the
manufacturer. The agreement does not give
the buyer the right to submit warranty claims
to the manufacturer. Transport expenses or
other costs are not covered by the warranty.
ATTENTION:
Electrical devices and appliances must be
checked/inspected at a time stipulated by
valid legislation of the country the device
is operated in. Inspection of wiring may
only be done by a person with valid autho-
risation for this activity. Service work,
provision of spare parts and inspection is
done by the manufacturer or an authoris-
ed service centre.
9. DESCRIPTION OF THE DEVICE:
1. JG straight 12,7x12,7 mm 5. Overow
1.a Straight nipple(modications) 6. Thermostat
2.a Screw clamp (modications) 7. Main switch
3. Hose with insulation 12,7x9 mm 8. Power cable
4. Agitator pump
gure 6 A

AS - 40 Glykol
7
gure 7 C
10. PLASTIC TANK FILLING AND CONNECTION WITH BEER TANKS:
gure 7 A gure 7 B
Pour liquid here

8
11. PUTTING INTO OPERATION:
1. Fill the plastic tank with liquid (antifreeze based on monopropylene glycol) up to the over-
ow.
WARNING: If you discover a leak, turn o the device. Fix any leaks found on the tubing. If
a leak is found inside the device or you are unsure how to proceed, contact a service centre.
2. Connect the cooling machine to the tank, see Fig. 7C (diagram of the connection of the coo-
ler to the tank).
3. Before connecting the mains, make sure that the voltage and frequency corresponds to the
data on the production sticker on the left side of the cooler. If the data matches, connect the
device to the mains.
4. Press the main switch to position (I) to turn on the cooling unit.
5. Using a thermostat, set the temperature of the water bath in the plastic tank to the desired
temperature and leave for approx. 30 - 40 min. to cool down.
NOTE: For connection use only the ttings and clamps specied by the supplier. Use ca-
librated hoses.
12. HOW TO WORK WITH SPEED FITTINGS:
12.1 Speed Fittings Installation:
Grasp the speed tting and insert the hose all
the way inside the speed tting body (ca. 20
mm). The end of the hose must be straight so
that it plugs fully into the coupling. If the hose
will not go in, moisten the end of the hose.
Hold the grey ring tight against the body of
the speed tting and pull out the hose.
12.2 Speed Fittings Removal:
WARNING: If you do not hold the grey ring but pull at the hose, the speed tting will cut
even deeper into the hose.
WARNING: Hoses must not be pressurised during removal.
gure 8 A
gure 8 B
WARNING: When the pump is switched on, the liquid from the plastic tank will be pumped
into the circuit of external container, therefore it is necessary to add liquid to the plastic tank
before the circuit is completely lled.

AS - 40 Glykol
9
Displaying Set Temperature:
1. Short-press the SET button. The display will show the set value.
2. To return the display to the current temperature, again short-press the SET button or wait
5s.
Changing Set Temperature:
1. Hold the SET button for more than 2 s.
2. The set temperature will be displayed and the °C indicator will begin ashing.
3. The set temperature can be changed by pressing or (within 10 s).
4. The newly set temperature can be saved by pressing the SET button again or automatically
by waiting 10 s.
13. THERMOSTAT STC 200, Dixell XR20CX:
gure 9 a
14. INSPECTION BEFORE EVERY USE:
1. Visual check.
2. Lead-in cable check.
3. Condenser cleanliness check (in case of excess pollution of the condenser, clean more
frequently than 1x a month).
4. Inspection of water level.
WARNING: Do not use the device if defects or malfunctions are found.
15. PERIODIC CHECKS:
1x day: check the water level in the tank.
1x a week: check that the lead-in cable is
undamaged and that the plug is rmly in the
socket.
1x a week: check that the device is not ex-
posed to radiant heat.
1x a week: check that air circulation is not
obstructed.
11x a month: check the cooling unit‘s con-
denser and clean it regularly.
1x a month: check water purity in the devi-
ce (cooler tank), or change it if necessary.
1x a year: have an engineering inspector
check the electrical safety of the device.
WARNING: Do not tamper with or move the device while it contains water. Doing so could
result in water overowing from the tank.
gure 9 B

AS - 40 Glykol
10
16. MAINTENANCE:
The condenser must be checked for cleanliness every month. Any dirt found must be cleaned with
compressed air or wiped o. Otherwise, there is a risk of reduced cooling output or damaging of
the cooler.
Wipe the device only with a soft and, if needed, lightly moistened cloth.
17. ENVIRONMENTAL PROTECTION:
Waste Sorting:
This product must not be disposed of in communal waste. Electrical waste in the Czech
Republic is disposed of within the Rema System (www.remasystem.cz).
In countries other than the Czech Republic, waste sorting is subject to local regulations.
Sorted waste enables recycling and reusing used products and packaging materials. Reuse
of recycled material helps protect the environment from pollution and reduces resource
consumption. Local regulations may regulate the method of disposing household appli-
ances at local collection points or at the point of sale.
18. TABLE OF MALFUNCTIONS:
Malfunction Cause Removal
The device is too noisy. The device is in contact
with a foreign object.
There is a sunken fo-
reign object in the fan
compartment.
Move the object that is touching the
device so that it is not in contact with the
cooler.
Remove the object from the fan com-
partment.
The device does not
work.
Power cable is not plug-
ged in.
The main switch is not
turned on or the the-
rostat is incorrectly set.
Plug in the power cable. Check that the
power cable is undamaged.
Turn on the main switch and set the
thermostat to the desired value.
The device is turned on
but does not cool.
The air vents are ob-
structed.
The device has a dirty
condenser.
Make sure the air vents are unobstructed.
Remove coarse dirt and dust by wiping.
Speed ttings. Hose poorly inserted.
Scratches on the hose.
Unplug the hose from the speed tting
and check that it does not have a sharp
edge.
Shorten the hose with a knife if necessary.

11
NOTE: If the defect persists even after the above steps are taken, contact a service
centre.
Do not forget to specify the following:
• type of defect
• type of product
• production year
• product‘s serial number (found on the plate)
19. SPARE PARTS:
When ordering spare parts, always provide the following:
• product type
• production year
• product‘s serial number
Ordering Components:
ALWAYS USE ORIGINAL COMPONENTS. The manufacturer or supplier bear no
responsibility for non-original components or components not recommended
by the manufacturer.
20. TECHNICAL DATA:
Name AS 40 GLYKOL
Green Line
Power (Hp) 1/8
Power (W) 310
Maximum output (l/hour) 40
Continuous output (l/hour) 25
Temperature dierence Δt (°C) 10
Coolant type R290
Voltage (V/ Hz~1) 220 – 240 V 50Hz~1
Input power (W) (W) 437
Current (A) (A) 1,9
Frame dimensions (WxDxH mm) 440x270x395
Net weight (kg) 17,0
Water tank volume (l) 12