manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Livart
  6. •
  7. Humidifier
  8. •
  9. Livart L-2O92 Instruction sheet

Livart L-2O92 Instruction sheet

This manual suits for next models

1

Other Livart Humidifier manuals

Livart L-763CP Instruction sheet

Livart

Livart L-763CP Instruction sheet

Livart L-493B User manual

Livart

Livart L-493B User manual

Livart L-282M User manual

Livart

Livart L-282M User manual

Livart H-8800 Series Assembly instructions

Livart

Livart H-8800 Series Assembly instructions

Popular Humidifier manuals by other brands

Scarlett Comfort SC-AH986E22 instruction manual

Scarlett

Scarlett Comfort SC-AH986E22 instruction manual

SOLAC HU1060 Instructions for use

SOLAC

SOLAC HU1060 Instructions for use

Vicks FilterFree use and care manual

Vicks

Vicks FilterFree use and care manual

Philips HU4902 quick start guide

Philips

Philips HU4902 quick start guide

Bionaire CM1 Instruction leaflet

Bionaire

Bionaire CM1 Instruction leaflet

Air-O-Swiss AOS 7131 Instructions for use manual

Air-O-Swiss

Air-O-Swiss AOS 7131 Instructions for use manual

Vitek VT-1768 BK Manual instruction

Vitek

Vitek VT-1768 BK Manual instruction

KING K 5002 Rainbow instruction manual

KING

KING K 5002 Rainbow instruction manual

Crane EE-6902 instruction manual

Crane

Crane EE-6902 instruction manual

Glaziar Ness user manual

Glaziar

Glaziar Ness user manual

Philips DreamStation Go Faqs

Philips

Philips DreamStation Go Faqs

Honeywell MISTMATE HUL520BC manual

Honeywell

Honeywell MISTMATE HUL520BC manual

Stadler Form Hera Operation instructions

Stadler Form

Stadler Form Hera Operation instructions

Hunter 31206 owner's guide

Hunter

Hunter 31206 owner's guide

TaoTronics TT-AH004 user guide

TaoTronics

TaoTronics TT-AH004 user guide

adorini Cigar Heaven manual

adorini

adorini Cigar Heaven manual

Aprilaire 800 Series user manual

Aprilaire

Aprilaire 800 Series user manual

Pyle SereneLife PHUMDIF8 Instruction book

Pyle

Pyle SereneLife PHUMDIF8 Instruction book

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

LIWT
Operating
lnstructions
ULTRASONIC HUMIDIFIER
WARM & COOI MIST
MODEL:L-2O92 lL-2093C
Thank you for choosing the LIVART Humidifier. Please read these instructions before using the LIVART
Cool Mist Ultrasonic Humidifier and keep them in a safe place for future reference. lf you pass the
humidifier on to anyone else, you should also pass on the instructions. Remove all packaging before
using the product, but keep the packaging until you are satisfied that the product is operating correctly.
1. Read the operating instructions carefully before using the humidifier and
keep them for later reference.
2. connect the unit only to alternating curent with voltage according to the
rating label.
3. Only use the humidifier indoors. lf used for a purpose it is not intended
it could cause serious danger to health and life.
4. Children cannot recognize the hazards associated with the usage of
electrical appliances. For this reason, always supervise children when they
are near the humidifier.
5. Person who are not familiar with the operating instructions, as well as
children and person under the influence of medication, alcohol, or drugs are
not permitted to operate the appliance, or are only permitted to operate it
under supervision.
6. Never use the appliance if there is any damage to the appliance or cable,
after malfunction, after the appliance has been dropped or damaged in any
other way.
7. Only operate the humidifier when it is completely assembled.
8. Repairs of electrical appliances are only to be made by qualified service
engineers. lmproper repair work can cause considerable danger to the user.
9. Disconnect the appliance from the mains power before filling/emptying the
water tank, before cleaning/maintenance,iassembling/dismanfl ing of
individual parts and before moving it.
10. Place the humidifier on a dry, level surface.
11. Do not pour water into the ventilator of the humidifier.
12. Do not put any additives in the waler. (e.9. fragrances, essential oils, water
fresheners, etc.)
13. Do not submerse the main body in water or other liquids.
N The using of tap water can be main cause of breakage of transducer due to,,
compounds of calcium in the water. So please use a scale filter atter
purchasing it additionally. (lF you use the clean water, never happen scalec.r
transducer and vaporized cleaning vapor.)
Generol informqtion
A comfortable atmosphere indoors is reached with a
relative humidifier level between 40% and 60%.
Water tank
Water-level sensor
Reservoir
Power cord
Main body
3
A _ _ _ Finding the ideal location lor your LIVART humidifier.
a GAUTION :ffuxi?!"li::lx;lllr;Slxlil;rm:ai:x'i:3,:':1x,f,:i:fi:ai'oorwirhf'|oorheatins'
IMake sure that no foreign objects
are in the water tank. N-,
1
(D
plD
d6P
Fill the tank with clean, cold water
from the tap or purifier.
(no hotter than 40"C).
. lfyou use clean water, you can use the
appliance with cleaning state for a long
time and lor sanitary reasons, good
for your health.
Close the cap of the water tank properly.
. Wait until the reservoir in the appliance is filled with
water.
rD .\.-/
lnsert the plug into the socket.
. lnsert the plug into the socket and switch on the appliance
using the onioff switch.
4
. L-2092
r On-otf switch.
I . Turning the right switch clockwise o
POWER
o
EMPTY
oFF6fr9x
,:'dH;":
iv.j
POWER
Regulation of vapor output.
. Regulates the vapor output lrom low to high. o
POWER
o
EMPTY
OFFAON
;'ffi;,
ltd,
POWER
. [-2093C
tOn-Off switch and operation with
WARM/COOL.
. Turning the POWER switch clockwise.
. On selecting WARM is preheated to 60'C
before entering the resevoir So the vapor
will have the pleasant temperature of 40"C.
This provides the advantage that the room
temperature will not fall, and additionally the water
can be kept essentially cleaner. (bacteria are killed.)
Regulation of vapor output.
. Regulates the vapor output from low to high
MED
@
MIST
o
POWER
o
EMPTY
cooL
oFFrtA\wARM
.'A*xL'.
,sil,
POWER
cooL
oFFZAWARM
:'5gi
is#j
POWER
MED o
POWER
o
EMPTY
MIST
5
A Caution
) Switch off the appliance and unplug it from the socket before cleaning it.
) Clean the water tank and the reservoir regularly.
\t->
6
Attention
. lf possible, use clean water.
. Make sure that no water gets into the lower
part of the main body.
. Clean the inner parts with a soft cloth. Do
not use any solvents or aggressive cleaning
agents to clean the appliance.
. Only use the brush to clean the transducer,
this should be done once a week. ffie
I
2
?
Cleon the humidifier os descriH eorlier ond
dry it thoroughly.
Avoid high temperolures.
Preferobly store the opplionce in ih originol
box.
Problem Possible couse Whot to do
,,Hitllidilhr,&es
:n0tiOp.$-t$e . Power cable not plugged in.
. Humidifier not switched on.
. No water in the tank.
(Empty-light flashing)
* Plug in power cable.
*- Push pcrwerbutton.
: Fill tank with water.
. Water temperature is too low. : Set vapor output to maximum about
10 min. ln that case, the humidifier
will work properly again.
Ito.vryor.aqlpUt
.fiQricl-e-aning
mtl toea,
. Mineraldeposits on transducer. *- Clean transducer again.
L!30,* Li2093C""
&iirii$rnK.g! 120V AC / 60Hz
40w 140W (Cool mist : 40W)
2.5 gal.l day 3.5gal./day(Cool mist:2.5)
1.7 gal.
14.8 x 7.8 x 15.2 in.
7.0lb.av.
PIease contact your dealer il, despile
strict quality control, your humidifier becomes
defective.
This product is warranted for 3 months and you
must present the receipt when making a claim
under the warranty.
- LG-LIVART
2110 S. TUBEWAY AVE.
COMMERCE, CA 9OO4()
- Toll Free :1-877-260-4949