Lodar 92320 User manual

w92320.09
20 Function and IP Extend Transmitter
SYSTEM PART NUMBER
92320 1 x 20 Function Receiver & 1 x 10 Function Extend Transmitter
(20 Function in Extend Mode)
REPLACEMENT TRANSMITTER
92310TX - 10 Function IP Transmitter with
Extend Buttons.(20 Function in Extend Mode)
REPLACEMENT RECEIVER
9220RX - 20 Function Receiver
TRANSMITTER SPECIFICATION
ENCLOSURE
Material ABS
Switch Type Tactile Dome on PCB Keypad
Functions 10 (20 with dual function buttons)
Identification Pockets for printed text or image insertion
RF
Modulation 2-GFSK. Gaussian Frequency Shift Keying
Frequency 433.050 MHz to 434.790 MHz
Channels 1
Channel Selection Fixed
Technology Hand-held Transmitter
Temperature Range -10o C to + 40o C (13o F to + 104o F). Use Lithium for lower temperatures
Range 60m (200ft)
Aerial Internal –printed on PCB
Transmitted power 1mW Typical
POWER
Batteries 4 x AAA Alkaline Manganese in holder (6 Volts)
Quiescent Current 15µA
Current Transmitting 20mA
PROTECTION
IP Rating 65
Registration codes Over 16 million
INDICATOR
Type 1 x Red LED
Off Transmitter is OFF and in standby mode
Slow flash Transmitter is ON and ready for use (The SET Button has been pressed and released)
On Transmitting (A STOP, SET or Function Button is being pressed)
Fast flash Transmitting –Indication that the battery will need replacing soon
Enclosure Slow Flash ON and ready for use with Receiver 2. The SET button has been pressed and released
COMPLIANCE
FCC FCC CFR 47-part 15.231
433.9MHz
IC ISED RSS-210 Issue 8
433.9MHz
RoHS Directive 2011/65/EU
CONTENTS
1 x Receiver
1 x IP Extend Transmitter
1 x Lanyard
1 x Instructions

w92320.09
RECEIVER SPECIFICATION
ELECTRICAL
Voltage Nominal 12/24V DC
Voltage Min/Max 8 to 36V DC
Switch Type MOSFET (Positive Switching)
RF
Modulation 2-GFSK. Gaussian Frequency Shift Keying
Frequency 433.050 MHz to 434.790 MHz
902.025 MHz–927.975 MHz
Channels 32
Channel Selection Fixed
Channel hopping
Technology Fixed Receiver
Temperature Range -40o C to + 80o C (-40o F to + 176o F).
Range 60m (200ft)
CURRENT CAPACITY
FET Rating 10A
System Rating 10A
Quiescent Current 31mA 12V/ 17mA 24V on Standby (Not SET)
Overload Protection 10A (Auto Shutdown)
AERIAL
Internal Antenna Yes Supplied and fitted
External Antenna Optional AC9860/ AC9861/ AC9862/ AC9863 & AC9869 –order separately
OUTPUTS
Master Yes Parallel or Continuous
Function 20 Supply to Receiver is switched
CONFIGURATION
RS232 Programming Yes For programming interlocks, push/push latch, parallel master inhibit, timeout, channel timeout delay,
to users’requirements master on delay, radio button de-latching and output allocation.
PERFORMANCE
Simultaneous Outputs Yes Programable (Modify through configuration)
Instant TX response Yes Programable (Modify through configuration)
DIAGNOSTICS
LED’s Yes Confirm 5 Volts, SET, Fault and all Outputs.
PROTECTION
Back EMF Yes Diode protection on all outputs
Registration codes Yes Over 16 million
STOP Connection Yes Internal Emergency Stop Connection
WIRING
Wiring Loom No Upon Request
Cable Gland Yes Supplied (Not fitted)
Connections Screw terminal into plug and socket on PCB, for easy “swap out”

w92320.09
ENCLOSURE
Weight 0.5 lbs (335gms)
Lid Clear PC/FR V0 and UV stabilised
Base Black PC V0 and UV stabilised
Breather Gortex fitted in base
Mounting 4 external lugs
Fixings 5mm (3/16”) not supplied
IP Rating IP55
S = Standard. C = Customer configured (see “Factory Settings”).
+ Positive 8-36V supply
- Negative 0 Volts
F1 to F16 Outputs to F1 through F16
M Master Output
STOP - STOP, when grounded shuts down the Receiver
S+ S- Master Secondary for Safety solenoid connections etc.
ANT Blade connector for internal antenna
SMA Aerial connection for optional external antenna (internal antenna must be removed)
LK1 Master Selection by Jumper (Parallel)
LK2 Master Selection by Jumper (Continuous)
Factory Settings 418/915MHz configured Parallel, 433.92MHz configured Continuous
RS232 RS232 for Wired Remote and interface to access special programmes
92 Series
92320
BUILD SPECIFICATION TABLE FOR MODELS IN THIS RANGE
Ident
Legend
Connection
+ -
Positive, Negative,
S
M, F1, F2, F3
Master F1, F2 and F3
S
F4, F5, F6, F7
F4, F5, F6 & F7
S
F8, F9 & F10
F8, F9 & F10
S
F11, F12, F13, F14
F11, F12, F13 & F14
S
F15, F16, F17, F18
F15, F16, F17, F18
S
F19, F20
F19, F20
S
S+, S-
Safety Solenoid S+ and S-
S
STOP, 0Volts
STOP connections
S
ANT
Internal Antenna
S
SMA (external antenna)
S
LK1
LK1
Master - Parallel
C
LK2
LK2
Master - Continuous
C
RS232
RS232
S
Number of Receivers
1
Number of Transmitters
1

w92320.09
COMPLIANCE
REG 10 EC Type-approval mark E11 037601
EC Type-approval No: e11/72/245*2009/19*7601*00
FCC FCC CFR 47 Part 15.109
433.050MHz to 434.790MHz
FCC CFR 47 Part 15.109
902.025MHz to 927.975MHz
IC ICES-003 Issue 6.
433.050MHz to 434.790MHz
ICES-003 Issue 6.
902.025MHz to 927.975MHz
CE RED Directive
ETSI EN 300 220-2 v3.2.
ETSI EN 300 220-1 v3.1.1.
ETSI EN 301 489-17 V3.1.1,
ETSI EN 301 489-1 V2.1.1
433.050MHz to 434.790MHz
Australia/NZ ETSI EN 300 220-2 v3.2.1
ETSI EN 301 489-1 V2.1.1
433.050MHz to 434.790MHz
915.025MHz to 927.975MHz
RoHS Directive 2011/65/EU
RECEIVER PCB –Component Side
This is viewable through the clear lid of the Receiver.
LED’s are visible for confirmation that the system is operating correctly.
These are: -
+5V Power Supply OK
SET Receiver operational
Fault Flashes for 20 seconds
At “power up”
Tx coding window open
Fault ON = Current overload
LED’s F1 to F20 and M
ON when there is an output

w92320.09
EXPLANATION OF “SHIFT” & “EXTEND” OPERATIONS - as illustrated with a 20 Function Transmitter.
These “SHIFT” operations can be applied to ALL Transmitters. For example, a 10 function Transmitter will
give 20 functions –ideal if you do not want the larger 20 function Transmitter.
To operate 2 x 20 function Receivers, giving 40 functions
This is a standard 20 function Transmitter, modified so that it
transmits 20 functions in two different modes.
The Green SET Button is the SHIFT button. Both 20 function
Receivers can therefore be operated by one Transmitter.
Press the Green SET Button to turn both Receivers on - it will start
in mode One; press it again for mode Two; press it again for mode
One, and so on.
Press the Red Stop button to turn both modes off.
Receiver One (functions 1 to 20) is operated with the SHIFT buttons
in mode One, indicated when the Keypad LED is flashing during
operation.
Receiver Two (functions 21 to 40) is operated with the SHIFT
buttons in mode Two, indicated when the Enclosure LED is flashing
during operation.
To register a Transmitter to its TWO Receivers.
Switch OFF or DISCONNECT the power to the Receivers.
Switch ON or Reconnect the power to Receiver ONE, this opens a 10 SECOND registration window in its
processor.
Immediately PRESS and HOLD the green SET button while the registration window is open until the SET LED
lights (5 seconds), the SHIFT function must NOT be active.
Receiver TWO, repeat the process but this time PRESS and HOLD the SHIFT button, and PRESS and HOLD
the SET button until its SET LED lights.
You have now coded the Transmitter to both receivers.
Table of contents
Popular Transmitter manuals by other brands

Endress+Hauser
Endress+Hauser Heat Brief operating instructions

Metal Samples
Metal Samples MS2500L Operator's manual

Freelap
Freelap Tx Pad Pro quick start guide

Measy
Measy WHD/LKV-388A user manual

HK Instruments
HK Instruments RHT DUCT Series installation instructions

Define Instruments
Define Instruments TM-USB Setup