Quick Start Guide
13
June 2016
N5 FM Class 1, Division 2, and Dust Ignition-proof
Certificate: 3034378
Standards: FM Class 3600:1998, FM Class 3610:2010, FM Class 3810:2005,
NEMA-250:1997, IEC 60529:2004
Markings: NI CL I, DIV 2, GP A, B, C, D; T4(–50 °C ≤ Ta≤+70 °C); DIP CL II/III DIV 1, GP E, F,
G; –50 °C ≤ Ta≤ +85 °C; when installed per Rosemount drawing 00849-1000;
Type 4X; IP66
Canada
I6 CSA Intrinsic Safety
Certificate: 1261865
Standards: CSA Std. C22.2 No. 25-1966, CSA Std. C22.2 No. 30-M1986, CAN/CSA C22.2
No. 94-M91, CSA C22.2 No. 142-M1987, CAN/CSA C22.2 No. 157-92, CSA
Std. C22.2 No. 213-M1987, CSA Std. C22.2 No 60529:05
Markings: Intrinsically Safe for CL I, DIV 1 GP A, B, C, D; Suitable for CL I DIV 2 GP A, B, C,
D; when installed per Rosemount drawing 00849-1016; T3C; Type 4X, IP66
See Table 2 at the end of the Product Certifications section for entity parameters.
N6 CSA Class I, Division 2
Certificate: 1261865
Standards: CSA Std. C22.2 No. 25-1966, CSA Std. C22.2 No. 30-M1986, CAN/CSA C22.2
No. 94-M91, CSA C22.2 No. 142-M1987, CSA Std. C22.2 No. 213-M1987,
CSA Std. C22.2 No 60529:05
Markings: Suitable for CL I DIV 2 GP A, B, C, D; T3C; when installed per Rosemount
drawing 00849-1016; Type 4X, IP66
Europe
I1 ATEX Intrinsic Safety
Certificate No.: Baseefa09ATEX0022X
Standards: EN 60079-0:2012, EN 60079-11:2012
Markings: II 1 G Ex ia IIC T4/T5 Ga
T4(–60 °C ≤Ta≤+70 °C), T5(–60 °C ≤Ta≤+40 °C)
See Table 2 at the end of the Product Certifications section for entity parameters.
Special Conditions for Safe Use (X):
1. The surface resistivity of the antenna is greater than 1 GΩ. To avoid electrostatic charge
build-up, it must not be rubbed or cleaned with solvents or a dry cloth.
2. The power module may be replaced in a hazardous area. The power module has surface
resistivity greater than 1GΩand must be properly installed in the wireless device
enclosure. Care must be taken during transportation to and from the point of
installation to prevent electrostatic charge build-up.
3. The enclosure may be made from aluminum alloy with a protective polyurethane paint
finish; however, care should be taken to protect it from impact or abrasion when located
in Zone 0.
International
I7 IECEx Intrinsic Safety
Certificate: IECEx BAS 09.0004X
Standards: IEC 60079-0:2011, IEC 60079-11:2011
Markings: Ex ia IIC T5/T4 Ga, T4(-60 °C ≤Ta≤+70 °C), T5(-60 °C ≤Ta≤+40 °C)
See Table 2 at the end of the Product Certifications section for entity parameters.