Settings Adjustment With Remote Control
Security time: The Security time, prevents continuous flushing of water due to
reflections or vandalism. By default, if the sensor is covered for more than 90 seconds
the water flow will shut automatically. To resume regular operation any obstruction
must be removed.
Press the SEC button. Wait until a quick flashing of the red light of the sensor eye is
perceived. Then, press + to increase the security time and – to reduce it.
Detection Range: The sensor range is the greatest distance that an object can be
away from the sensor to activate the tap.
The sensor is factory preset. To adjust the sensor range press + to increase
detection range and – to decrease the detection range of the sensor.
Delay in time: It is recommended to change the delay in time for flush valves for urinals
or toilets only.
If required, the delay in time can be modified in taps as follows: Press the IN button.
Wait until a quick flashing of the red light of the sensor eye is perceived. Then, press +
to increase the delay in time and – to reduce it.
Delay out time: This button allows modifying the water flow time after the user
removes his hands from the tap. A delay out time close to 0 will save more water. An
increased delay out time will make the user experience more comfortable.
If required, the delay out time can be modified as follows: Press the OUT button.
Wait until a quick flashing of the red light of the sensor eye is perceived. Then, press
+ to increase the delay out time and – to reduce it.