LUCHT LHZ Technotherm VPN DSM 750 User manual

Feel good through warmth from electricity - www.technotherm.de
Installa on and Opera ng Instruc ons
VPN with DSM or TDI/plus thermostat for wall moun ng
Please read attentively and keep in a safe place!
Subject to alterations!
Id_no.
Issue 02/19
Types:
• VPN DSM 750
• VPN DSM 1000
• VPN DSM 1200
• VPN DSM 1500
• VPN DSM 2000
• VPN H DSM 1200
• VPN plus 750
• VPN plus 1000
• VPN plus 1200
• VPN plus 1500
• VPN plus 2000
• VPN H plus 1200

Feel good through warmth from electricity - www.technotherm.de
Installaon and Operang Instrucons
VPN devices
Feel good through warmth from electricity - www.technotherm.de
GB
1. General informaon about our heaters
With our variety of electric heaters, you can nd the right soluon
for your needs in any spaal situaon. The TECHNOTHERM heaters
are available as addional or transional heang for all rooms in the
living area, with the excepon of the special cases stated in the safe-
ty instrucons. They are designed for connuous operaon. Prior
to dispatch, all our products undergo an extensive funcon, safety
and quality test. We guarantee a construcve design complying with
all currently applicable internaonal, European and German safety
standards and rules. You can see this in the labelling of our products
with the well-known cercaon marks: “TÜV-GS”, “SLG-GS”, “Key-
mark” and “CE”. Our heaters are evaluated in accordance with the
internaonally applicable lEC-regulaons. The manufacture of our
heaters is constantly supervised by a state-accredited test centre.
This heater can be used by children aged from 8 years and above and
by physically, sensory or mentally restricted persons if they are super-
vised or given instrucons on safe use and understand the hazards
involved as it does not require any experience or knowledge. This
device is not a toy for children to play with! Cleaning and user main-
tenance shall not be carried out by children without supervision. The
use of heat radiators is to be given a parcular duty of care by super-
visors. Children under the age of 3 are to be kept away unless they
are connually supervised. Children between the age of 3 and 8 are
only allowed to switch the heater on or o if they are supervised or
given instrucons on safe use and understand the hazards involved,
provided that it has been placed or installed in its intended normal
operang posion. Children between the age of 3 and 8 shall not
plug in, regulate and clean the heater or perform user maintenance.

Installa on and Opera ng Instruc ons
VPN devices
Feel good through warmth from electricity - www.technotherm.de
GB
Cau on: Some parts of the product can become very hot and cause
burns. Pay par cular a en on when children and vulnerable people
are present.
Warning! this device has to be grounded
This device may only be operated using alterna ng current and the opera ng voltage indicated on the
power ra ng plate
• Nominal Voltage 230V AC, 50 Hz
• Protec on Class I
• Degree of Protec on IP 20
• Room Thermostat 7°C ll 30°C
2. User manual for the VPN DSM
Please see addi onal manual at
h� ps://www.technotherm.de/manuals.html
Plus/TDI thermostat
The instruc on will be enclosed separately if required
3. Maintenance
Before cleaning the device be sure to turn it o . To clean use a damp towel and a mild detergent.
This device is used only for wall moun ng!

Feel good through warmth from electricity - www.technotherm.de
Installaon and Operang Instrucons
VPN devices
Feel good through warmth from electricity - www.technotherm.de
GB
4. Assembly instrucon
This Manual is very important and has to be kept at a safe place at all mes. Be sure to hand this ma-
nual to any other succeeding owner of the device. The device comes with a power plug that has to be
plugged into an outlet.
The device is designed to be connected to 230V (nominal) alternang current (AC).
5. Wall Installaon
When installing the device, the safety distance must be strictly adhered to, so that ammable materials
can not ignite. Install the device to a wall which is heat resistant up to 90 ° C.
• Due to possible re hazard the safety distances are observed during assembly:
Side walls of the heater to any masonry: 5 cm
Side walls of the heater to combusble materials: 10 cm
Distance radiator to the oor: 10 cm
arranged spaced upper radiator limit to about components or covers (. Eg window):
ammable 15 cm
nonammable 10 cm
The safety distance to the oor should be 10 cm, and at least 10 cm to all other devices. Furthermore
there has to be safety distance of approximately 50 cm between the venlaon grille, windowsills, roof
slopes and ceilings.

Installaon and Operang Instrucons
VPN devices
Feel good through warmth from electricity - www.technotherm.de
GB
6. Wall Mounng
Type Power
[Wa]
With
A
High
B
Deep
C
[mm]
D
[mm]
E
[mm]
F
[mm]
G
[mm]
H
[mm]
I
Weight
[kg]
VPN
750
750 750 450 85 442 140 375 100 115 375 11,5
VPN
1000
1000 750 450 85 442 140 375 100 115 375 11,5
VPN
1200
1200 750 450 85 442 140 375 100 115 375 11,5
VPN
1500
1500 1050 450 85 740 140 375 100 115 525 15,0
VPN
2000
2000 1050 450 85 740 140 375 100 115 525 15,0
VPN H
1200
1200 450 1050 85 252 99 809 100 100 275 15,0
7. Installaon of Electricity
The device was developed for an electrical voltage of 230 V(nominal) and an alternang current of (AC)
50 Hz. The electrical installaon may only be performed according to the user manual and only by a
qualied Electrician. The device was designed to be used with terminaon and the connecon cable
has to be plugged into an appropriate socket at all mes. (Noce Permanent cables may not be used)
The distance between the receptacle and the device hast to be at least 10cm. The connecon line may
not touch the device at any me.

Feel good through warmth from electricity - www.technotherm.de
Installaon and Operang Instrucons
VPN devices
Feel good through warmth from electricity - www.technotherm.de
GB
8. Regulaon
From 01.01.2018, the EU conformity of these devices is addionally linked to the fulllment of the
Ecodesign requirements 2015/1188.
The installaon and commissioning of the devices is only permied in conjuncon with external room
temperature controllers that fulll the following funcons:
• electronic room temperature control
and has at least one of the following properes:
• room temperature control, with presence detecon
• room temperature control, with open window detecon
• with distance control opon
• with adapve start control
The following room temperature controller systems
• DSM-Thermostat with the DSM-Interface (Art.No.:911 950 101)
• TDI- Thermostat / plus-Thermostat
from Technotherm meet the following requirements and therefore the ErP Direcve:
• electronic room temperature control plus week mer (DSM/plus/TDI)
• room temperature control, with open window detecon (DSM/plus/TDI)
• with distance control opon (DSM)
• with adapve start control (DSM/plus/TDI)
Failure to comply with these requirements will result in the loss of the CE mark.

Installaon and Operang Instrucons
VPN devices
Feel good through warmth from electricity - www.technotherm.de
GB
10.Informaon requirements for electrical local space heaters
Type: VPN plus/TDI
Item Symbol Value Value Item Value
Heat output Type of heat input, for electric storage local space heaters only (select
one)
Nominal heat
output Pnom 1000 1200 1500 2000 Wa manual heat charge control, with integrated thermostat NO
Minimum heat
output (indicave) Pmin 1000 1200 1500 2000 Wa manual heat charge control with room and/or outdoor tempera-
ture feedback
NO
Maximum con-
nuous heat output Pmax,c 1000 1200 1500 2000 Wa electronic heat charge control with room and/or outdoor
temperature feedback
NO
Auxiliary electricity
consumpon
fan assisted heat output NO
At nominal heat
output elmax 1000 1200 1500 2000 Wa Type of heat output/room temperature control (select
one)
At minimum heat
output elmin 2.0 2.0 2.0 2.0 Wa single stage heat output and no room temperature control NO
In standby mode elSB <0,5 <0,5 <0,5 <0,5 Wa Two or more manual stages, no room temperature control NO
with mechanic thermostat room temperature control NO
with electronic room temperature control NO
electronic room temperature control plus day mer NO
electronic room temperature control plus week mer YES
Other control opons (mulple selecons possible)
room temperature control, with presence detecon NO
room temperature control, with open window detecon YES
with distance control opon YES
with adapve start control YES
with working me limitaon NO
with black bulb sensor NO
Contact Lucht LHZ Elektroheizung GmbH & Co.KG - Reinhard-Schmidt-Str. 1 - 09217 Burgstädt - Germany

Feel good through warmth from electricity - www.technotherm.de
Installaon and Operang Instrucons
VPN devices
Feel good through warmth from electricity - www.technotherm.de
GB
Type: VPN DSM (addional DSM interface oponally necessary)
Item Symbol Value Value Item Value
Heat output Type of heat input, for electric storage local space heaters only (select one)
Nominal heat
output Pnom 1000 1200 1500 2000 Wa manual heat charge control, with integrated thermostat NO
Minimum heat
output (indicave) Pmin 1000 1200 1500 2000 Wa manual heat charge control with room and/or outdoor tempera-
ture feedback
NO
Maximum con-
nuous heat output Pmax,c 1000 1200 1500 2000 Wa electronic heat charge control with room and/or outdoor
temperature feedback
NO
Auxiliary electricity
consumpon
fan assisted heat output NO
At nominal heat
output elmax 1000 1200 1500 2000 Wa Type of heat output/room temperature control (select
one)
At minimum heat
output elmin 0,8 0,8 0,8 0,8 Wa single stage heat output and no room temperature control NO
In standby mode elSB 0,8 0,8 0,8 0,8 Wa Two or more manual stages, no room temperature control NO
with mechanic thermostat room temperature control NO
with electronic room temperature control NO
electronic room temperature control plus day mer NO
electronic room temperature control plus week mer YES
Other control opons (mulple selecons possible)
room temperature control, with presence detecon NO
room temperature control, with open window detecon YES
with distance control opon YES
with adapve start control YES
with working me limitaon NO
with black bulb sensor NO
Contact Lucht LHZ Elektroheizung GmbH & Co.KG - Reinhard-Schmidt-Str. 1 - 09217 Burgstädt - Germany
Technotherm is a label from Lucht LHZ GmbH & Co. KG
Reinhard Schmidt-Str. 1 | 09217 Burgstädt, Germany
Phone: +49 3724 66869 0
Telefax: +49 3724 66869 20
info@technotherm.de | www.technotherm.de
Technical alternaons, errors, omissions and errata reserved. Dimensionsare stated without warranty!
Updated: 02/ 19
TECHNOTHERM Aer-sales service:
Ph. +49 (0) 911 937 83 210
This manual suits for next models
11
Table of contents
Popular Thermostat manuals by other brands

BDR Thermea Group
BDR Thermea Group 28220 installation manual

Salus
Salus ERT50 UP instruction manual

Bticino
Bticino KW4691 manual

OJ Electronics
OJ Electronics MCD5-1999 instruction manual

ApenGroup
ApenGroup SMART WEB Series Operating, Installation and Programming Manual

SPC
SPC Modulo Installation and operating instructions

Danfoss
Danfoss DEVIreg Smart installation guide

Bio Green
Bio Green Thermo 2 Installation and operating instruction

Honeywell
Honeywell Easy-To-See T87N1000 owner's manual

Beretta
Beretta Alpha 7D Installation and user instructions

LUX
LUX KONOz user manual

EUROSTER
EUROSTER 2006 Installation and operation manual