Full product range & more information: www.lumenalights.com
INSTALLATION:
IMPORTANT: Cable should be laid inside armoured conduit or piping to protect from water-logging, chemicals found in soil
and damage. If buried, it should be buried to at least 0.5m below ground to reduce damage risk. If this method is not used,
cable warranty will be void.
Always test bollards prior to installation.
1. Remove the mounting base by releasing the 3 x grub screws with the allen key provided
2. Position bollard mounting base in the desired location, ensuring the supply cable is central to
the base and enough cable is available to easily connect to the inline connector at the base of
the tube / body with plenty of slack for ease of wiring.
3. Secure the base in place with the correct fixings for your surface (3 x expanding anchor bolts
have been supplied for optional use), with the mains cable protruding through the centre.
4. Carefully lay down the bollard on a soft, protective surface e.g. cloth / cardboard and
connect the mains cable to the bollard via the In-line connector provided (see diagram).
Alternatively, change the connector to a waterproof,
multi-way junction box. IMPORTANT: Check that the
supply wires are correctly identified, the connections
are tight and that there are no loose strands. Also
check that the connector is fully tightened and sealed.
5. Push the cable up as high up inside the tube as
possible, reposition the tube back over the bollard
base and secure in place with the allen screws
removed in step ‘1’. If applicable, ensure photocell in
the tube is facing the correct direction for optimum
light sensitivity.
6. Test the bollard –for photocell models, the photocell
will need to be covered for daytime testing which has
a short delay of <5 secs.
J-BOLTS
To mount into wet concrete, attach the J-bolts to the template with one nut
below and one nut above. Set into concrete (use a spirit level) with the mains
cable protruding through the centre. Once set, attach the base to the J-Bolts
with the lock washer and remaining nut, wire up and re-attach the bollard
tube.
INTERNAL SUPPORT
For additional support at the lower tube, attach the internal support (sold separately) by bolting to the top
of the mounting base via the 3x threaded holes. (see image) >
WIRING:
Please Note: For models with a photocell, the photocell is pre-wired within the head, not the
connector block at the base of the tube. Should the photocell become faulty, please contact us
for further information.
In-line Connector
1. Unscrew and remove the cap and thread from the open end of the connector
2. Unscrew cap from cable end of connector and move up the cable
3. Pull the red, rubber grommet up the cable to the label (approx.)
4. Pull centre sleeving up the cable pushing the cable downward to reveal the terminal block
5. Loosen the 3 screws at the open edge of the connector block.
6. Place end cap and thread over your prepared mains cable and then wire into the connector block
accordingly, fastening the 3 screws to secure the cables in place. Ensure there are no loose strands
and that the wire is clamped, not the rubber sheath. Each terminal is marked with the Live,
Neutral or Earth Symbol, with the screw threaded towards the relevant terminal.
7. Always check wires are connected to the correct wire / terminal.
8. Reassemble the in-line connector:
a. Pull the sleeving back over the terminal
block, then pull red, rubber grommet back
inside the flexi-end of sleeving, then replace
end cap securely (clockwise –turning end
cap –DO NOT TWIST CABLE).
b. Reattach the thread to the sleeving, fully
encasing the terminal block and then the end
cap (DO NOT TWIST CABLE)