Maan VESUVIO User manual

S5
S1
S2
S4
VESUVIO – Cooker hood
OPERATION MANUAL
General safety and installation conditions:
When installing the appliance, follow the conditions and guidelines given in this operating manual.
This appliance is intended for domestic use only. In case of commercial use in food business,
warranty conditions change.
Do not remove the plug from the power socket by pulling the cord.
The power cord must not touch any hot surface.
Do not turn the appliance on if the power cord is damaged
The cooker hood, if used to extract cooking fumes outside, should be connected to an appropriate
ventilation duct (do not connect it to flues, smoke or exhaust ducts which are in use).
The manufacturer assumes no responsibility for any damage caused by the installation not
conforming to the operating manual.
Any changes made in the structure of the hood by unauthorized persons will result in
the exclusion of the liability of the manufacturer.
If the cooker hood is used simultaneously with devices burning gas or other fuels, the room
should be appropriately ventilated (not applicable in the case of closed circulating system).
Do not use naked flame directly under the cooker hood,
If the non-detachable power cord is damaged, it should be replaced with a special cord available
from the manufacturer or a specialized repair shop.
The exhaust air from the hood must not be discharged into a flue used for discharging exhaust
fumes from appliances burning gas or other fuels (not applicable in the case of closed circulation
mode).
Before connecting the cooker hood to the main power supply and checking its correct functioning,
always check if the power cord is properly installed and has not been pinched by the hood during
installation.
Cleaning not carried out in accordance with the manual constitutes a fire hazard.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge of the appliance, unless
they are given supervision or instructions according to the operating manual by persons responsible
for their safety.
Purpose and operation
The hood is intended for operations in a suction mode, discharging the fumes outside, or for operation
in a filter mode as a closed circulation system.
Installation
The minimum distance between the surface on which dishes are placed on the heating appliance and
the lowest part of the cooker hood should be no less than 45cm in the case of electric stoves and no
less than 65cm in the case of gas or dual electric/gas stoves. If the manual of the heating appliance
recommends a larger distance for installation of a cooker hood, you must comply with these instructions.
Installation of the hood and the hood’s casing pipe is shown in Figure S3. When installing the hood,
you should observe the general regulations on discharging air from the room. You should take into
account the fact that the use of spiral aluminium pipes reduces the efficiency of the hood and increases
the noise level of the flowing air.
Electrical connection
The mains voltage must comply with the conditions specified on the rating plate inside the hood. If the
hood is equipped with a plug it needs to be put into a socket meeting the requirements of the applicable
regulations and located in an easily accessible place. If the hood is not equipped with a plug, the hood
should be installed by an authorized person.
Maintenance

Before proceeding to any maintenance operations, unplug the hood from the power supply. The appliance
should be cleaned with special cleansing agents for surface made of stainless sheet metal or coated
sheet metal. The hood should be cleaned with mild detergents, do not use abrasive cleaners. Regular
maintenance will improve the operation of the hood.
Caution: DO NOT USE ALCOHOL!!!
Grease filter
The cooker hood is equipped with an aluminium filter. The filter is removed by moving the locks in the
direction indicated by the arrow (Fig. S1). The filter should be cleaned manually in the following manner:
immerse it for 15 minutes in water mixed with mild detergent at the temperature of 40-50°C. After 15
minutes, start washing the filter and rinse it carefully. The filter must be completely dry before it is put
back in the hood. If the filter is not cleaned regularly, the performance of the hood decreases and
the fire risk increases. If washed in a dishwasher, the filter may become discoloured, but this does
not affect its filtering properties.
Charcoal filters (Only for closed circulation mode - Fig. S5)
The cooker hood can be equipped with carbon filters. Carbon filters are used only when the hood is NOT
connected to a ventilation duct. The filters should be placed on the turbine casing, as shown in Fig. S5.
In this case, the filtered air is discharged back into the room. The hood should not be connected to
ventilation ducts. In order to ensure correct operation and efficient filtering of odours, the carbon filters
should be replaced regularly (every 3 to 6 months), depending on the intensity of utilization of the hood.
Lighting replacement (Fig. 2)
Before proceeding to any operations related to lighting replacement, unplug the hood from the power
supply. If the hood was previously on, wait a few minutes and only replace the bulb after it cools down.
Caution! Do not touch the bulbs as long as they are hot. Make sure you do not touch the front of the bulb
you install directly with your fingers.
Aluminium filter replacement - Fig. S1
Lighting replacement - Fig. S2
Hood and chimney installation – Fig. S3
Hood dimensions – Fig. S4
Charcoal filters replacement - Fig. S5
The symbol placed on a product or on the accompanying documents means that this
product may not be treated as household waste. In order to dispose of the appliance,
you should take it
to an appropriate collection point for the recycling of electrical and electronic equipment.
Disposal must be carried out in accordance with local regulations concerning waste disposal.
For more information about utilization, scrapping and recycling of this appliance, please contact
your local authorities, waste disposal facility or the store where you purchased the product.
Manual control (push button)
Control of the turbine in the hood
„0” – turns the turbine on
„1” – turbine works at the minimal speed
„2” – turbine works at the medium speed
„3” – turbine works at the maximum speed
The turbine is turned on by pressing the selected button. The higher speed, the bigger the air flow.
„Light bulb icon” - Press the button to t urn lights on. Press it the second time to turn the lights off.
6x PW8x40
6x HS4,0x45
2x O3,9x9,5
2x O2,9x9,5
S3