Magner Magner100 User manual

Magner100 User Manual
Rev 2.1.0
Advanced intelligent single pocket
currency counter.
Reliable discriminator with
excellent
counterfeit detection.
Easy Maintenance for cleaning
sensors
1 POCKET CURRENCY COUNTER& DISCRIMINATOR

- Contents –
Introduce ............................................................................................................................ 3
....................................................................................................................For Safety Use 3
.......................................................................................................................Appearance 10
1. Display Description …………………………………………………………………………11
2. Key Operation Description …………………………………………………………………12
3. Basic Operation
3-1 . COUNT Mode 14
3-2 . EURO Mode 17
3-3 . USD Mode 17
3-4 . Local Currencies Mode 18
4. Operation Mode I
4-1 . BATCH Mode 19
4-2 . CF Mode 20
4-3 . ADD Mode 20
4-4 . GRAND TOTAL Mode 24
5. Operation Mode II
5-1. MIX Mode 27
5-2. SP Mode 28
5-3. SP VERS Mode 28
5-4. SG Mode 29
6. USER Mode ………………………………………………………………………………….30
SPECIFICATION ………………………………………………………………………………….
33
Error Code List ………………………………………………………………………………….34
Maintenance 36
Simple Trouble Shooting 37
MAGNER100 USER MANUAL
Magner INT!2

Introduce
Thanks for your purchase of iSNIPER.
iSNIPER is the advanced intelligent single pocket currency counter.
Depending on the variant used, it can be used to check banknotes for authenticity,
denomination, value, to sort and account these accordingly and to count banknotes.
Utilizing Full IR CIS sensor, it can recognize value and count banknotes, while providing
the highest level of protection against counterfeits.
iSNIPER works with External Display, Serial Printer and PC.
For Safety Use
In this section, the compliance matters are described in order to use the product safely, and to
prevent you and other people from the damages brought by the product to the human bodies or
properties.
Please read this instruction manual thoroughly in advance to use in the correct way.
Appearance
MAGNER100 USER MANUAL
Magner INT!3
Warning Maintenance
1. For repairing the product, please contact our distributor near you or our designated
dealers. Insufficient repair may cause fire, electric shock, and/or injury.
2. When the product has sunk under the water due to a disaster etc., stop using it and
please ask for repair/check to our distributor near you or our designated dealers. If
used as it is, it may cause fire and/or electric shock.
3. Check periodically whether its installation place is unstable or not. If there is any
abnormality, please contact our distributor near you or our designated dealers. If it is
continuously used with insufficient installation, it may cause a falling accident.
4. Check and clean the power supply plug and the cord regularly. It the power supply
plug is broken or the cord is damaged, stop using and please replace it by contacting
our distributor near you or our designated dealers. It may cause fire and/or electric
shock.
When smoke, abnormal smell, or abnormal sound is generated from the product, stop
using it immediately, cut off power supply and pull out the plug from the outlet. Then,
please contact our distributor near you or our designated dealers. It used or left as it
is, it may cause fire and/or electric shock.
Warning Power Supply
1. When using the product, connect it to the power supply specified in the instruction
manual. If it is connected to the power supply, other than the product’s specification, it
may become a cause of fire, electric shock, and/or electrical leakage.
2. Do not use a power supply cord and the plug other than the attached ones. If a
current that exceeds the rating flows in the power supply cord, it may cause fire.
3. Be sure to insert the blade part of the power supply plug into an outlet. Insufficient
insertion may cause fire.
1. When the earth leakage breaker frequently operates, please contact our distributor
near you or our designated dealers. If the product is used or left as it is, it may cause
fire and/or electric shock.
2. Do not modify, process, or repair the power supply cord and the plug. In addition, do
not convert a 3-prong power supply plug into a two-pole type. Grounding becomes
insufficient and there may cause electric shock.
Please follow the items below to prevent electric shock and/or fire due to damage of
the power supply cord.
- Do not pull the cord part when pulling out the power supply plug.
- Do not put anything on the cord part.
- Do not pass the cord near a source of heat.
- Do not bend or pinch the cord.
- Do not tread or twist the cord.
- Do not spill chemicals on the cord.
- Do not use it while it is bundled.
- Do not fix it with a stapler etc.
Caution Handling
1. The product should be used under the environment specified in the instruction
manual. If it is used under the other environment of the specification, there may cause
fie and electric shock.
2. When operating inside the product for error or clearing or cleaning etc., the
operation should be made in accordance with the description in the instruction
manual. Operation other than the description may cause an accident.
1. Do not turn off the power, pull out the power supply plug, or open the cover of the
product during the operation. Otherwise, it may cause an accident.
2. Do not put a vase or glass with an object and/or water etc. on the product.
Otherwise, it may cause fire, electric shock, and/or injury by spilling water or dropping.
3. Do not apply shock on the product. There is a risk of damaging the product and
normal operation cannot be performed.
4. Do not use chemicals such as thinner or benzene when removing dirt of the
product. Otherwise, it may cause damages.
5. Do not use a interface cable other than the attached one. When cables are other
than the attachment, it may cause the interface error or machine trouble.
Do not us a combustible spray etc. around product. If spray gas etc. contacts the
electrical parts inside the product, it may cause explosion and fire.
Warning
Caution
It denotes the contents in which mishandling of the product by
neglecting this indication may cause the people’s light injury or only
physical damage.
It denotes the contents in which mishandling of the product by
neglecting this indication may cause the people’s serious injury.
This symbol indicates that the precautions for handling the product.
Please read the indications well and utilize the product safely.
This symbol indicates prohibited matters not to do. Please read the
indications well and never do the prohibited matters.
This symbol denotes that there are indication matters which should be
done without fail. Please read the indicated matters thoroughly and
perform the matters without fail.
Warning Installation
1. At installation and relocation of the products, please contact our distributor near you
or our designated dealers. If installation is not perfect, there is a risk of a falling
accident, electric shock, fire and burn injury.
2, At installation and use of the products, keep the space sufficient for opening and
closing the door, cover and operation. If a part of the product touches a human body, it
may cause an accident.
3. In case of installing the product at the following places, you should confirm the Road
Law, Road Traffic Law and Fire Protection Law, etc. If compliance conditions are not
clear, please consult with the authorities concerned.
- The place which may disturb traffic or accident prevention.
- The place adjacent to the fire extinguishing and detecting apparatus.
- The place adjacent to the road signs or traffic signals.
- The place where combustible materials or gas are treated (gas stations, etc.)
Passages and facilities for evacuation Illegal installation may cause an accident.
4. Keep an installation space as described in the instruction manual, and do not choke
up the ventilation inlet. If the ventilation inlet is choked, heat is accumulated inside and
it may cause fire.
5. Depending on the installation place, mounting of an earth leakage breaker is
required by Electricity Enterprises Law. Illegal installation may cause an accident.
1. Do not install the product at the place where water may spill on it. If water enters into
the product, insulation performance degrades and it may cause fire and/or electric
shock.
2. Do not install the product at the place where the floor cannot bear the load of the
product, or at the unstable place with inclination and/or irregularity. It may cause the
accidents of floor caving and sudden move of the product.
3. Installation at the following places should be avoided.
There are safety problems and deterioration of the product may be accelerated,
which leads to a cause of failure.
- 1m or less from volatile combustible materials or curtains.
- 1m or less from heating apparatus such as stoves, heaters etc.
- The place brown by direct winds from air conditioners, ventilating openings etc.
Grounding work should be made for safety and prevention of static electricity and
noise failure. In addition, a ground wire should be installed independently without
sharing the wire with other products. At grounding work, please be sure to contact our
distributor near you or our designated dealers. In case of electrical leakage when
grounding is insufficient or not connected, it may cause fire and/or electric shock.
The place where a ground wire can be fitted:
- Ground terminals for power receptacle.
- The copper piece etc. with a length of 65 cm or more, buried in the ground.
- The ground terminals on which grounding work is made.
The place where is a ground wire must not be fitted.
- Gas pipes
- Telephone wires for exclusive use
- Lightning rods
- Water pipes or faucets with plastic materials at their intermediate part.
-The place with high temperature, high humidity, or low temperature.
-The place with direct sunlight.
-The place with much dust.
When installing the product at the following places, please contact our distributor
near you or our designated dealers.
-The place exposed to salty winds or corrosive gas.
-The place with much swinging or vibration.
5. There is a charging part inside. Be sure to open the cover with turning off the
power. If the cover is opened without turning off the power, it may cause electric
shock.
1. Do not drop any metallic piece such as a clip, staple etc. inside or in a clearance of
the product. If a metallic piece drops inside the product and contacts the electric
circuit, it may cause fire.
2. When the product is not use for a long time, be sure to pull out the power supply
plug from an outlet for safety. Otherwise, it may cause heating and/or firing due to
dust accumulation.
Do not modify the product or mount modified parts on the product. Further, do not
dismount the portion which is not indicated to be opened/closed in the manual, or the
cover and parts etc. fixed with screws etc. Otherwise, it may cause fire, electric
shock, and/or injury.
1. Do not approach your hand or cloths during operation to moving parts of the
product reachable. There may cause injury and/or pinching of a finger.
2. When closing a door, pay attention not to pinch a finger. It may cause of injury.
3. When working with a door opened, confirm it is locked. It may become a cause of
injury because the door may suddenly close.

Gap Adjustment Knob
USB Port
Power Switch
Power Connector
Serial Port
External Display Port
Hopper Guide
Hopper
LCD Display
Release Button
Stacker Pocket
1. Display Description
MAGNER100 USER MANUAL
Magner INT!4
MIXCF
€0
0
B100S1000ADD
Currency
Operation Mode
Total Value
Note number of
Stacker
Counterfeit Detection

2. Key Operation Description
~
Number Key for selecting Batch number and Shortcut Key.
Clear Batch number to 0.
Counterfeit detection function key (Operation Mode) & double
detection function key (COUNT Mode)
Select Currency
Select ADD Mode and G.TOTAL Mode.
Select Batch number which was selected already.
1. Select Counting Speed in COUNT Mode.
2. Select denomination in SG Mode. 3. Enter Engineer Mode.
1. Select Operation Mode.
2. Enter USER Mode
Print counting result to print or screen.
1. Clear counting result on the screen.
2. Exit sub Mode.
Shortcut Key (Long Key Operation)
If press and hold down Number Key, you can select special currency or mode directly.
Go to COUNT Mode.
Go to EURO (local currency 1) Mode.
Go to USD (local currency 2) Mode.
Go to local currency 3 Mode.
Go to local currency 4 Mode.
Go to local currency 5 Mode.
Go to local currency 6 Mode.
Go to NORMAL COUNT Mode.
Go to ADD Mode.
Go to GRAND TOTAL Mode.
MAGNER100 USER MANUAL
Magner INT!5

3. Basic Mode
1. COUNT Mode
MAGNER100 USER MANUAL
Magner INT!6
When press LEVEL Key, DDL is changed.
And long LEVEL Key can enter CF LEVEL MODE.
In this mode, user can select DDL, UVL, MGL and SIZE DETECTION.
Move Cursor
Change Level.
Exit CF LEVEL MODE.
Double Detection Level
DDL means Double Detection Level in Count Mode.
User can select 1~8 levels.
- DDL 1~2 : For local currency.
- DDL 3 : For Euro
- DDL 4 : For USD
- DDL 8 : If the notes are darker than EURO or USD or the notes are so old, user can
select this level to detection double notes. But when counts normal notes
in this level, the machine do not detect the double notes. Please take
care.
COUNT
0
B100S1000--
CNT DLL:0¦●+++++++¦
UVL:0¦●+++++++¦
MGL:0¦●++++++++¦
======================
CFLEVELMODE
======================
>>DLL:Level00%
UVL:Level00%
MGL:Level00%
SIZEDETECT:DISABLE
COUNT
0
B100S1000--
CNT DLL:2¦++●+++++¦
UVL:0¦●+++++++¦
MGL:0¦●++++++++¦
Display shows as below.
Press CURRENCY Key and
select COUNT Mode.
User can count all currencies without
recognition and detection.
COUNT
0
B100S1000--
CNT DLL:0¦●+++++++¦
UVL:0¦●+++++++¦
MGL:0¦●++++++++¦
☞Preparing Banknotes
Make sure that there are not paper clips, rubber bands, staples or similar objects
of the banknotes.
Before inserting the banknotes, sort out any banknotes with following
characteristics.
▶Extreme damages
▶High soil levels
▶Folded/bent banknotes
▶Highly wrinkled banknotes
▶Limp banknote

UV Level
In COUNT Mode, machine has adjusted UV
Level function for detecting white paper.
User can select 1~8 levels.
According to thickness of notes, UV Level is
different.
Before counting, please check and adjust
Level first.
COUNT
0
B100S1000--
CNT DLL:0¦●+++++++¦
UVL:0¦●+++++++¦
MGL:0¦●++++++++¦
======================
CFLEVELMODE
======================
DLL:Level00%
>>UVL:Level228%
MGL:Level00%
SIZEDETECT:DISABLE
MG Level
COUNT
0
CNT DLL:0¦●+++++++¦
UVL:0¦●+++++++¦
MGL:0¦●++++++++¦
======================
CFLEVELMODE
======================
DLL:Level00%
UVL:Level00%
>>MGL:Level457%
SIZEDETECT:DISABLE
COUNT
0
B100S1000--
CNT DLL:0¦●+++++++¦
UVL:0¦●+++++++¦
MGL:0¦●++++++++¦
SIZECHECK!
COUNT
0
B100S1000--
CNT DLL:0¦●+++++++¦
UVL:0¦●+++++++¦
MGL:0¦●++++++++¦
======================
CFLEVELMODE
======================
DLL:Level00%
UVL:Level00%
MGL:Level00%
>>SIZEDETECT:ENABLE
SIZE Detection
In COUNT Mode, machine can have simple
detection function by adjusting MG Level.
User can select 1~8 levels.
Before counting, please check and adjust
Level first.
If SIZE DETECTION is enabled, machine can detect the different size note.
When a note which has a different size (±5mm) from the first note is inserted, machine stops.
2. EURO Mode
MAGNER100 USER MANUAL
Magner INT!7

Display shows as below.
Press CURRENCY Key and
select EURO Mode.
Press MODE Key and select
Operation Mode.
In this Mode, the machine can recognize
and detect EURO currency.
MIXCF
€0
0
B100--
3. USD Mode
Display shows as below.
Press CURRENCY Key and
select USD Mode.
Press MODE Key and select
Operation Mode.
MIXCF
$
0
B100--
In this Mode, the machine can recognize
and detect USD currency.
4. Local Currencies Mode
MAGNER100 USER MANUAL
Magner INT!8

Display shows as below.
Press CURRENCY Key and
select local currency.
Press MODE Key and select
Operation Mode.
MIXCF
LC
0
B100--
Note!
Some local currencies may be counted only.
4. Operation I
4-1. BATCH Mode
MAGNER100 USER MANUAL
Magner INT!9

4-2. CF Mode
4-3. ADD Mode
MAGNER100 USER MANUAL
Magner INT!10
When press and hold down ADD Key,
you can enter ADD or G.TOTAL Mode.
Press MODE Key to select item.
Select 2. ADD and press SET Key to
enter.
MIXCF
€0
0
B100--
If you want to detect counterfeit
during counting, press CF Key..
Display shows as below.
MIXCF
€0
0
B100--
-- - Machine doesn’t detect counterfeits.
CF - Machine detects counterfeit with UV, MG and IR.
UV - Machine detects counterfeit with UV.
IR - Machine detects counterfeit with IR.
UV+MG - Machine detects counterfeit with UV and MG.
UV+IR - Machine detects counterfeit with UV and IR.
MG+IR - Machine detects counterfeit with MG and IR.
When you select LOCK, the previous condition is kept although you press CF Key.
Display shows as below.
If press BATCH Key, user can select
batch number which is registered
already. (5, 10, 20, 50, 100)
When user wants to select special
batch number, please use Number
Key (0~9).
If press CLEAR Key, batch number
will be changed to 0.
MIXCF
€0
0
B100--
MIXCF
€100
2,000
B100--
Note!
When counting number gets to batch
number, machine stops to count
and !mark is shown.
! means a note can be placed
inside the machine. When
remove notes from Stacker,
one note will come out.

MIXCF
[ADDTOTAL]
€0
0
B100ADD
MIXCF
[CURRENT]
€76
1,180
B100ADD
MIXCF
[ADDTOTAL]
€76
1,180
B100ADD
Display shows as below. When count notes, display shows the current
counted information
When remove the notes from stacker,
display shows added information between
current and ahead counted notes.
MIXCF
[ADDTOTAL]
€118
1,830
B100ADD
MIXCF
[CURRENT]
€42
650
B100ADD
When count notes again, display shows
the current counted information
When remove the notes from stacker,
display shows added information between
current and ahead counted notes.
Verify Function
MAGNER100 USER MANUAL
Magner INT!11

MIXCF
[VERIFY]
€0
0
B100ADD
In ADD Mode, press ADD Key
again shortly.
VERIFY function is activated and
display shows as below.
When VERIFY function is turned
on, you can count new notes
which is no relation with ADD
value.
Save ADD value to MEMORY
Delete ADD value from MEMORY
MIXCF
[ADDTOTAL]
€76
1,180
B100ADD
MIXCF
[ADDTOTAL]
€76
1,180
B100ADD
MIXCF
[ADDTOTAL]
€0
0
B100ADD
Select item 2. CLEAR ADD and press SET Key. The value is deleted from MEMORY and exit
ADD STATE menu.
MAGNER100 USER MANUAL
Magner INT!12
Press and hold down START Key,
ADD STATE menu appears.
You can save or delete ADD value
to MEMORY.
MIXCF
[ADDTOTAL]
€76
1,180
B100ADD
Select item 1. SAVE ADD and press SET Key.
The value is saved to MEMORY and exit ADD
STATE menu.
You can check it ADD STATE menu.
MIXCF
[ADDTOTAL]
€76
1,180
B100ADD
Note!
Frequent saving data to MEMORY can shorten the life of Main Board.

4-4. GRAND TOTAL Mode
MAGNER100 USER MANUAL
Magner INT!13

When press and hold down ADD Key,
you can enter ADD or G.TOTAL Mode.
Press MODE Key to select item.
Select 3. G.TOTAL and press SET Key
to enter.
MIXCF
€0
0
B100--
MIXCF
[GRANDTOTAL]
€0
0
B100GT
MIXCF
[CURRENT]
€49
760
B100GT
Display shows as below. When count notes, display shows the current
counted information
MIXCF
[ADDTOTAL][1]
€49
760
B100GT
When remove the notes from stacker,
display shows ADD TOTAL x value .
Save ADD TOTAL x to GRAND TOTAL
MAGNER100 USER MANUAL
Magner INT!14
When press START Key, you can check ADD TOTAL and GRAND TOTAL value.
MIXCF
[ADDTOTAL][7]
€42
650
B100GT
MIXCF
[GRANDTOTAL]
€606
11,380
B100GT

Delete GRAND TOTAL value
Select item 4. CLEAR G.TOTAL and press SET Key.
G.TOTAL value is deleted exit ADD STATE menu.
MIXCF
[ADDTOTAL][1]
€49
760
B100GT
MIXCF
[GRANDTOTAL]
€0
0
B100GT
5. Operation Mode II
Operation Mode
MIX Mode
Count all denomination of selected currency.
SP Mode
The machine saves denomination information from first inserted note.
SP VERS Mode
The machine saves denomination and version information from first inserted
note.
SG Mode
Before counting, the user can select a specific denomination to be counted.
5-1. Mix Mode
5-2. SP Mode
MAGNER100 USER MANUAL
Magner INT!15
Press CURRENCY Key and select
currency which you want to count.
Press MODE Key and select MIX
Mode.
You can count all denomination of selected
MIXCF
€0
0
B100--
EURVALUECOUNTINGINFO
============================
€5:0¦€200:0
€10:5¦€500:0
€20:1¦
€50:12¦
€100:7¦
=======================================
TOTALCOUNT:25
TOTALVALUE:1370
After counting, if you press and
hold down PRINT Key, you can
check counting result on the
screen.
MIXCF
[ADDTOTAL][1]
€49
760
B100GT
MIXCF
[ADDTOTAL][1]
€49
760
B100GT
MIXCF
[GRANDTOTAL]
€49
760
B100GT
Press and hold down START
Key, you can save the value to
MEMORY or G.TOTAL.
Press MODE Key and select
item 2. SAVE ADD->G.TOTAL.
Press SET Key and save the
value to GRAND TOTAL.
MIXCF
[ADDTOTAL][3]
€38
590
B100GT

The machine sorts out the same denomination
with first inserted note.
Press MODE Key and select SP
Mode
Press CURRENCY Key and select
currency which you want to count. SPCF
€0
0
B100--
5-3. SP VERS Mode
The machine sorts out the same denomination
and version with first inserted note.
Press MODE Key and select SP
Mode
Press CURRENCY Key and select
currency which you want to count. SP(VERS)CF
$0
0
B100--
Press SET Key.
5-4. SG Mode
MAGNER100 USER MANUAL
Magner INT!16
Press MODE Key and select SG
Mode.
Press SET Key and select
denomination.
SG5CF
€0
0
B100--
Press CURRENCY Key and select
currency which you want to count
except USD.

6. USER Mode
Move cursor to upside or downside.
Enter item.
Move cursor to left or right and go to next page.
Go to higher mode or exit User Mode
MAGNER100 USER MANUAL
Magner INT!17
Press and hold down MODE Key.
USER Mode is shown.
USERMODEp1/1
=======================================
>>1.PRINTERSET
2.LCDLANGUAGE:ENGLISH
3.SPSELECT:REFRESH
4.WARNINGBUZ:ON
5.CFLOCK:UNLOCK
6.COMMA:ENABLE
7.STACKERBRAKE:OFF
8.AUTOSTART:ON
9.POWERSAVE:20MIN

1. PRINTER SET
1. BAUD RATE
Set up the baud rate between machine and printer.
2.PAPER SIZE
Set up the size of printer paper.
3. FONT
Set up the font size
4. BLANK OF TAIL
User set up the blank of tail.
5. PRINT NUMBER
Set up number of receipt.
6. PAPER CUTTING
Set up cutting paper automatically or manually.
7. PRINT ID
Select to print ID to receipt or not.
8. SELECT ID
Enter user ID to machine.
LEVEL and CURRENCY Key: Move position.
ADD and SET Key: Select characters.
2. LCD LANGUAGE
Select displayed language on screen.
3. SP SELECT
In SP Mode, machine recognized first note continuously or not.
REFRESH: After stop, machine remembers next inserted note again.
CONTINUE: Machine memorizes the first note continuously.
4. WARNING BUZ
If select ON, when error is caused, machine makes a beep.
5. CF LOCK
If you select UNLOCK, you can select the method of counterfeit detection.
After select UNLOCK, counterfeit detection function is changed by pressing CF
Key.
6. COMMA
If select ENABLE, display shows COMMA by the thousand.
7. STACKER BRAKE
If select ON, when error appears, machine stops the stacker before the error note
goes to Stacker pocket.
8. AUTO START
MAGNER100 USER MANUAL
Magner INT!18
1.PRINTERMODEp1/1
=======================================
>>1.BAUDRATE:115200BPS
2.PAPERSIZE:3INCH
3.FONT:12X24
4.BLANKOFTAIL:5LINE
5.PRINTNUMBER:1PIECE
6.PAPERCUTTING:NO
7.PRINTID:NO
8.SELECTID:”NONE”

If select OFF, machine start to count banknotes when operator press START Key.
9. POWER SAVE
If user does not use the machine during regular time, the machine enters screen
save state
SPECIFICATION ------------------------------------------------------------------
-Technical Specification
Available currencies
EURO, USD, LOCAL
Dimension(mm)
296(W)×325(L)×280(H)
Display
3.1” Graphic LCD (192x128
dot)
Weight
Approx. 10 Kg
Denomination Detection
Full Line Image Sensor,
Color Sensor
Countable Notes Size
W: 100 ×180mm
H: 60 ×90mm
Counterfeit Detection
UV, FL, MG (Magnetic
Thread Detection), IR
Countable Note
Thickness
0.08 ~ 0.12mm
Speed
Recognition
Count
900 notes/min
Hopper Capacity
500 notes
Piece Count
Max. 1100 notes/min
MAGNER100 USER MANUAL
Magner INT!19

Stacker Capacity
200 notes
Feed System
Roller friction type
Power Supply
100 ~ 240V AC, 50/60Hz
Power consumption
Approx. 140 Watts
-Features
Local Currency
Max. 4 currency
IR Detection
Full Line IR CIS Sensor
External Display
LCD type for customer
Bill Printout
With RS232C Interface for PC and external printer. Print user name.
Error Code List
No
Error Code
Description
1
Chain 1 error
The gap between two notes is under 100mm.
2
Chain 2 error
After note passes counter sensor, note length is over 100mm.
3
JAM 1 error
Encoder value isn’t increased although motor turns.
4
JAM 2 error
Because note places on Counter sensor and motor is kept turning ticking
over, length information is increased.
5
JAM 3 error
Note is not moved to upside when motor turns counter direction.
6
Motor error
Motor isn’t controlled properly.
7
Double error
Thickness by measuring IR is lower than the standard.
8
Half error
Only half of note is recognized.
9
MinSize error
Note size is smaller than the minimum size.
10
SKEW error
The difference between R and L is over 10 mm.
11
Rotate error
Note is rotated over an angle of 20 degrees.
12
XSize error
X size of note is not matched. (CIS sensor information)
13
YSize error
Y size of note is not matched. (Cnt sensor information)
14
IR 1 error
IR error
MAGNER100 USER MANUAL
Magner INT!20
Other manuals for Magner100
1
Table of contents
Other Magner Cash Counter & Coin Sorter manuals