Marquis WM 47 User manual

OWNER’S MANUAL
WM 33
WM 40
WM 42
WM 47
CIRCLE THE MODEL OF YOUR
COOLER AND RECORD THE SERIAL
NUMBER BELOW.
READ CAREFULLY ALL OF THIS
MANUAL BEFORE INSTALLING THE
UNIT
ENCIERRE CON UN CIRCULO EL
MODELO DE SU ENFRIADOR Y ESCRIBE
EL NUMERO DE SERIE ABAJO.
LEA CON CUIDADO TODO ESTE MANUAL
ANTES DE INSTALAR LA UNIDAD
SERIAL #
NUMERO DE SERIE
SAFETY RULES
1. Read instructions carefully.
2. Electrical hook up should be done by a qualified electri-
cian, so that all electrical wiring will conform to your local
standards.
3. Unit must be in the OFF POSITION and UNPLUGGED
from power receptacle when installing or performing any
maintenance.
4. Your cooler will run on 120 volt AC., 60 Hz (cycle) current
only.
5. Motorandpumparegroundedandhaveanautomaticther-
mal overload switch which will shut motor off when it
overheats. The motor will restart automatically when it
cools down.
WARNING: To reduce the risk of fire or electric shock,
do not use this fan with any “solid-state fan speed con-
trol device.”
READ AND SAVE THESE INTRUCTIONS
EVAPORATIVE COOLING
With this unit being a fresh air system, you are not trapped
with recirculating air that can become stale, laden with smoke
and odors, as happens with refrigerated air conditioning
systems. Instead, you are completely replacing the air every
2 to 4 minutes by either opening doors or windows or a
combination of both to exhaust the air continually.
VEA EL ESPAÑOL EN EL INTERIOR.
110528 3-01
OPERATION
To eliminate delivery of hot air when starting cooler, turn on
pump only for the first few minutes, then turn on the blower
motor.
These coolers may be used without water for ventilation
purposes. When outside air is cool (for example, at night) or
when humidity is high the water pump can be turned off.
www.championcooler.com

2110528
COOLER INSTALLATION
MOUNTING COOLER
CAUTION: Make sure that the mounting surface
is strong enough to support the operating weight of
the cooler when in use. (For operating weight, see
Specification Table.)
CAUTION: Never plug in cooler until installation is
complete and unit has been tested for rigidity.
•Lift out all removable louvered sides.
•Screw chain hooks into window facing. Position the two
chain hooks above the neck of the cooler a distance equal
to the width of the cooler apart (A-Fig. 1). Hook one hanger
chain in each hook and then an “S” hook in the other end of
each chain. NOTE: Chain hooks supplied with this mount-
ing kit have wood screw threads for wood walls. Concrete,
brickwallsorconcreteblocksrequiresufficientlystrongwing
nuts or anchors with mating hooks.
FIG. 2
WINDOW FILL-
IN PANELS
TOP PANEL
RETAINER
BOTTOM PANEL
RETAINER
RUBBER WASHER
OVERFLOW PIPE
NIPPLE
BOTTOM PAN
NUT
FIG. 3
A
B
C
D
E
FG
H
WINDOW
NECK
“S” HOOK
FIG. 1
•Install window panel re-
tainers. Place two panel
retainer strips onto bot-
tom of neck flange and
positiontothewidthof
the window. Cut the
strips to fit if neces-
sary. These strips
hold the window fill-
in panels (Fig. 2).
•Position cooler in
window. Position
neck of cooler so that
bottom of neck flange
rests on window sill
and flange (E-Fig. 1)
is snug against
edge of sill (H-Fig.
1). With cooler in
position, hook the
“S” hooks into the
holes of the top pan
near the back of the
cooler (B-Fig. 1).
•Break fill-in panels to
fit. With cooler installed, as described above, measure for
each window fill-in panel and score with sharp knife and
straight edge guide to desired width. To break window fill-
inpanels,thepanelshouldbelaidovertheedgeofastraight
flat surface at the point to be broken off. Apply pressure on
the edge of the panel that extends over the edge of the
surface and break off unwanted piece.
•Install fill-in panels. Place one window fill-in panel on each
side of grill and into panel retainer strip at bottom of grill.
Place the other panel retainer strips onto top of neck flange
and fill-in panels. Be sure the panels are snug up against
cooler neck.
•Place window behind retainer strip. Raise back of cooler
so that the window (D-Fig. 1) may be brought down behind
top of panel retainer strip (C-Fig. 1).
•Level Cooler. Adjust chains so that cooler is level.
•Adjust house legs. Pull out house legs so that the rubber
bumpers rest against house siding (F-Fig. 1). Tighten screw
in retaining collar. (G-Fig. 1).
OPEN WINDOWS TO EXHAUST AIR
An often misunderstood concept of evaporative cooling is the
amount of air that should be exhausted. How much should
you open your windows? The fact is that most people do not
open their windows enough. The following method will help
you determine the amount to open your windows.
CHAMPION AIR BALANCING METHOD
1. Take a piece of tissue paper and cut it lengthwise into 3
equal strips.
2. Turn your cooler on high cool.
3. Open one window at least six inches wide in each room
that you want to cool.
4. Take the piece of tissue paper and put it up against the
screen of the open window furthest from the cooler dis-
charge opening. Let go of it. It will do one of three things.
IF It falls down.
THEN CLOSE all of the windows one inch and try step 4
again.
IF It plasters itself to the screen.
THEN OPEN all of the windows one inch and try step 4
again.
IF It stays on the screen lightly.
THEN PERFECT. You are done. Enjoy your cooler.
NOTES:
• When switching to low cool, you must rebalance your home.
Repeat step 4.
• Once you balance your home you can cool some areas
more than others by opening those windows more and clos-
ing the others by the same amount. Repeat step 4 to make
sure your home is still air balanced.
CONNECTING WATER
•Install overflow assembly. Re-
move nut and place nipple
through the hole in the pan, with
the rubber washer between the
pan and the head of the drain
nipple (Fig. 3). Screw on nut and
draw up tight against bottom of
pan. Insertoverflowpipeinnipple
toretainwater. Theoverflowpipe
may be removed to drain the pan when necessary. A gar-
den hose may be screwed onto the drain nipple to drain
water away from your unit.

3
110528
•Connect water supply line.
Install a sillcock and water
valve on faucet as shown by
figure 4. Place the nut and
ferrule on the tubing and
tighten the nut until water
tight.
•Install float valve. Install
valve in the provided hole in
corner post (Fig. 5) and at-
tach water supply line.
•Fill pan. Allow water to
filltowithin1”oftopofpan
and adjust float to main-
tain this water level. This
can be accomplished by
bending the float rod (Fig.
5).
•Adjust water amount.
Your cooler is equipped
with a unique water me-
tering valve (Fig. 6). The
amount of water delivered to
thepadsmay be decreased by
pressing the plastic valve as
the arrows indicate. If water
is splashing out of water
troughs, you may need to de-
crease the amount of water
delivery. Check to see that all
pads are saturated with water
and that there are no dry spots
or openings in the pads.
•Change Pads. Aspen pads should be replaced once or
twice a season, depending upon the length of the season.
At the beginning and at mid season a clean pad is more
absorbent and efficient and will deliver substantially more
cool air.
•Oil bearings. The blower bearings and cooler motor in this
unit should be oiled with a few drops of non-detergent 20/
30 weight oil once each year. The motor does not need oil
if it has no oil lines for oiling. Motors that have no lines are
lifetime oiled at the factory and require no further oiling for
the life of the unit.
CAUTION: Do not over oil. Over oiling can cause mo-
tor burn out, due to excessive oil
getting into motor winding.
•Check belt tension. A 3 lb.
force should deflect the belt 3/
4 inches (see Fig. 8). Read-
just belt if needed.
WINTER SHUT DOWN
•Drain water. Always drain all of the water out of the cooler
and water supply line when not in use for prolonged peri-
ods, and particularly at the end of the season. Keep the
water line disconnected from both the unit and water sup-
ply so that it does not freeze.
•Cover unit. To protect the life of the finish, a cover for the
unit is suggested in extended periods of non-use.
•Unplug unit from power supply during extended peri-
ods of non-use.
By following the operating, installation, and maintenance sug-
gestions as outlined, you can get many years of efficient and
satisfactory service from your cooler. In the event additional
information is desired, your dealer will be more than glad to
assist you in every possible way.
INCREASE
DECREASE
FIG. 6
MAINTENANCE
WARNING: Before doing any maintenance be sure
power is off and unit is unplugged. This is for your safety.
SPRING START-UP
•Clean pump. Cleaning the pump is necessary once a year
at start-up. For your safety, turn unit off and unplug from
power receptacle. Remove the pump from the mount slot.
Remove the base of the pump as shown in Fig. 7. Clean
the pump and turn the impeller to ensure free operation.
Remove the pump spout and check for any blockage. After
cleaning, reinstall the base onto the pump. Reattach the
pump to the mount in
the cooler using the
plastic retainer to en-
sure that the pump will
not overturn. Do not
forget to replace the
spout and water deliv-
ery tube onto the pump
outlet. The pump has
automaticreset thermal
protection.
FLOAT ROD
WATER
SUPPLY LINE
WASHER
NUT
FERRULE
NUT
FIG. 5
CORNER POST
DEPRESS HERE
TO REMOVE
FIG. 7
FAUCET
WATER SUPPLY
VALVE
SILLCOCK
FERRULE
NUT
FIG. 4
WHITE-COM
BLACK-HI
PLAIN
BLOWER
MOTOR
PUMP
MOTOR
RED-LO
RIBBED-COM
GREEN-GROUND
WIRE CONNECTOR
GREEN
SWITCH
A
B
12
34
RIBBED-COM
PLAIN
WIRING DIAGRAM
FIG. 8
3 LB.
3/4 INCHES

4110528
PROBLEM POSSIBLE CAUSE REMEDY
Failure to start or no
air delivery
Inadequate air
delivery with cooler
running
Inadequate cooling
Motor cycles on and
off
Noisy
Excessive humidity in
house
Musty or unpleasant
odor
Water draining from
cooler
1. No electrical power to unit
• Fuse blown
• Circuit breaker tripped
• Electric cord unplugged or damaged
2. Belt too loose or tight
3. Motor overheated
• Belt too tight
• Blower bearings dry
4. Motor locked
1. Insufficient air exhaust
2. Belt too loose
3. Pads plugged
1. Inadequate exhaust in house
2. Pads not wet
• Pads plugged
• Open spots in pads
• Trough holes clogged
• Pump not working properly
1. Low voltage
2. Excessive belt tension
3. Blower shaft tight or locked
4. Bearings dry
1. Bearings dry
2. Wheel rubbing blower housing
3. Loose parts
1. Inadequate exhaust
1. Stale or stagnate water in cooler
2. Pads mildewed or clogged
3. Pads not wetting properly
• Trough holes clogged
• Pump not working properly
1. Float arm not adjusted properly
2. Overflow assembly leaking
1. Check power
• Replace fuse
• Reset breaker
• Plug in cords or replace if damaged
2. Adjust belt tension
3. Determine cause of overheating
• Adjust belt tension
• Oil blower bearings
4. Replace motor
1. Open windows or doors to increase air flow
2. Adjust belt tension or replace if needed
3. Replace pads
1. Open windows or doors to increase air flow
2. Check water distribution system
• Replace pads
• Repack pads
• Clean trough and unplug holes
• Replace or clean pump (Unplug unit)
1. Check voltage
2. Adjust belt tension
3. Oil or replace bearings (Unplug unit)
4. Oil bearings
1. Oil bearings
2. Inspect and realign (Unplug unit)
3. Tighten loose parts
1. Open doors or windows
1. Drain pan and clean pads
2. Replace pads
3. Check water distribution system
• Clean
• Replace or clean pump (Unplug unit)
1. Adjust float
2. Tighten nut and overflow pipe.
TROUBLESHOOTING

5
110528
SNOITACIFICEPSROTOM /ROTOMLEDSENOICACIFICEPSE
.oNledoM oledoM #traProtoM °N-rotoM PHPH deepS dadicoleV stloV soitloV #traPyelluProtoM °N-rotoMleDaeloP #traPdroClacirtcelE °N-ocirtcélEelbaC #traPtleBevirD °N-adnaB
33MW2440113/12 511172011863011)054-L4(112011
04MW2440113/12 511272011863011)005-L4(012011
24MW2440113/12 511272011863011)005-L4(012011
74MW3440112/12 511372011863011)005-L4(012011
SNOITACIFICEPSLARENEG /SELARENEGSENOICACIFICEPSE
.oNledoM oledoM
).sbl(thgieW )sarbil(oseP ).ni(snoisnemiDtenibaC )sadaglup(ajaCaLeDsenoisnemiD ).ni(d'qeRgninepOwodniW )sadaglup(adireuqeRarutrebA
yrD oceS gnitarepO onelL thgieH arutlA htdiW aruhcnA htpeD dadidnuforP htdiW aruhcnA thgieH arutlA
33MW25192261/7338/1828/1828/3528/721
04MW06173261/31938/1828/1828/3528/721
24MW07146261/31938/1432/1828/3528/721
74MW57196261/31938/1432/1828/3528/721
LIMITED WARRANTY
This warranty is extended to the original purchaser of an evaporative cooler installed and used under normal conditions. It
does not cover damages incurred through accident, neglect, or abuse by the owner. We do not authorize any person or
representative to assume for us any other or different liability in connection with this product.
TERMS AND CONDITIONS OF WARRANTY
For Five Years from date of installation, we will replace the original base assembly if water leakage should occur due to rust
out.
For One Year from date of installation, we will replace any original component provided by Champion Cooler Corporation
which fails due to any defect in material or factory workmanship only.
EXCLUSIONS FROM THE WARRANTY
We are not responsible for replacement of cooler pads. These are disposable components and should be replaced periodi-
cally. We are not responsible for any incidental or consequential damage resulting from any malfunction.
We are not responsible for any damage received from the use of water softeners, chemicals, descale material, plastic
wrap, or if a motor of a higher horsepower than what is shown on the serial plate is used in the unit.
We are not responsible for the cost of service calls to diagnose cause of trouble, or labor charge to repair and/or the
replacement of parts.
HOW TO OBTAIN SERVICE UNDER THIS WARRANTY
Contact the Dealer where you purchased the evaporative cooler. If for any reason you are not satisfied with the response
from the dealer, contact the Customer Service Department: Champion Cooler Corporation, 5800 Murray Street, Little
THIS LIMITED WARRANTY APPLIES TO ORIGINAL PURCHASER ONLY
This manual suits for next models
1
Table of contents
Languages:
Other Marquis Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual