EQ-1 MAINTENANCE
Preventative Maintenance
The MART Corporation recommends that a preventative maintenance schedule be
established for processing the wastewater. More frequent processing shortens the
treatment time and the reduces the dosage rate of the Magic Dust. A good starting
point to determine frequency is to treat the solution after one week of use. If this
processing proves successful, try treating after two weeks and continue extending the
time between treatments to determine the best treatment frequency. Note that, if the
reservoir is allowed to become too saturated with contaminants, the treatment process
will become difficult or even impossible.
Service Schedule
The only servicing to the MART EQ-1
Processor is a thorough washdown after each
use. The Processor has a built-in rinse system
to facilitate the wash down procedure. It is
important to periodically remove the secured
cover on the upper Reactor Tank for inspection
and cleaning as necessary.
Empty and rinse the Processor after each use.
Never leave solution in the Processor for
extended periods. Aggressive chemicals can
damage the finish and corrode the tanks. Clean
the Sight Tube with the Sight Tube Brush
provided with the EQ-1 Processing System.
S
Sight tube & Brush
For Maintenance and Servicing of the EQ-1 Sump Pump and Mixer, refer
to the vendor-supplied operating manuals or speak with a MART Service
Technician at 1-800-567-6278.
EQ-1 TROUBLESHOOTING
Problem Solution
Mixer will not start. 1. Check electrical connections.
2. Unplug unit from electrical receptacle and check power cord
GFI unit. Press “RESET” button.
3. Check Fuses for continuity.
4. Check timer settings.
Sump Pump will not
start. 1. Check electrical connections.
2. Verify that solution is in Holding Tank.
3. Check that Sump Pump Float Switch is not sticking.
Filter paper clogging. Pull forward and roll up used portion of Filter Paper so fresh clean
paper is on the Platen.
Filter paper tears. Too much waste material on filter paper will cause paper to tear
from the weight of water and waste.
Reverse the Platen so that bottom side faces upward. Reposition
the Filter Paper to extend beyond the Platen on all sides.
No floc, or very little
floc, or pin floc. 1. Verify that the specified Magic Dust compound is being used.
2. Verify that correct amount of Magic Dust is being used.
3. Add more Magic Dust.
4. Shorten Mix time. A long mix time may chew up the floc.
5. Verify that processing instructions in Manual are being followed.
Mixer Pump vibrates
while running. 1. Unplug electrical connection. Process wastewater to empty
Reactor Tank. Remove top cover. Inspect Propeller Blades and
remove any dried waste from Blades.
2. Rotate by hand to inspect motor shaft for straightness.
For technical assistance please contact:
MART Tech Services
2450 Adie Road, St. Louis MO 63043
Phone: 1-800-543-MART (314-543-6278)
1-314-567-7222 in Missouri
FAX: 1-314-567-6318
Web: www.marttechservices.com
Email: [email protected]
2

Other manuals for EQ-1

1

Popular Water System manuals by other brands

Monitor MFH-5398 instructions

Monitor

Monitor MFH-5398 instructions

EnerWorks EWRA2 installation manual

EnerWorks

EnerWorks EWRA2 installation manual

Grunbeck GENO-EDI-X Operation manual

Grunbeck

Grunbeck GENO-EDI-X Operation manual

Rotex Solaris RPS3 25M OPERATING AND INSTALLATION Manual

Rotex

Rotex Solaris RPS3 25M OPERATING AND INSTALLATION Manual

EarthMinded F-RN090 user guide

EarthMinded

EarthMinded F-RN090 user guide

IMI Hydronic IMI PNEUMATEX Pleno PI manual

IMI Hydronic

IMI Hydronic IMI PNEUMATEX Pleno PI manual

Intewa RAINMASTER Eco manual

Intewa

Intewa RAINMASTER Eco manual

Omnifilter B2000 Installation, operation and maintenance manual

Omnifilter

Omnifilter B2000 Installation, operation and maintenance manual

Taylex ABS owner's manual

Taylex

Taylex ABS owner's manual

EasyPro PA10 Installation, operating and maintenance instructions

EasyPro

EasyPro PA10 Installation, operating and maintenance instructions

Marco UNA FONT instruction manual

Marco

Marco UNA FONT instruction manual

Everpure Single Head EV9272-19 Specification sheet

Everpure

Everpure Single Head EV9272-19 Specification sheet

CLIVET WDAT-ik4 Manual for installation, use and maintenance

CLIVET

CLIVET WDAT-ik4 Manual for installation, use and maintenance

Mueller Hydro-Guard HG-3 Operating instructions manual

Mueller

Mueller Hydro-Guard HG-3 Operating instructions manual

Aqua Kinetic A200 owner's manual

Aqua Kinetic

Aqua Kinetic A200 owner's manual

Condair RO-U Installation, operation and maintenance

Condair

Condair RO-U Installation, operation and maintenance

flamco Airfix D Series Installation and operating instructions

flamco

flamco Airfix D Series Installation and operating instructions

Taco Comfort Solutions 1900e Series instruction sheet

Taco

Taco Comfort Solutions 1900e Series instruction sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.