Mastip MetiCom SC8 User manual

SC8
Sequence Injection Controller
User Guide
Ver. 2.0

Page | - 1 -© Page | - 1 - © Copyright Mastip Technology Limited. Information subject to alteration. V2.0 www.mastip.com
Sequential Injection Controller SC8
1. Warranty
We warrant that this product will be free from defects in materials and workmanship for a period
of 18 months from the date of shipment. If any such product proves defective during this
warranty period, at our option, either will repair the defective product without charge for parts
and labour, or will provide a replacement in exchange for the defective product.
This warranty shall not apply to any defect, failure or damage caused by improper use or
improper or inadequate maintenance and care. We shall not be obligated to furnish service
under this warranty; a) to repair damage resulting from attempts by personnel other than our
representatives to repair or service the product; b) to repair damage resulting from improper
use or connection to incompatible equipment; or c) to service a product that has been modified or
integrated with other products when the effect of such modification or integration increases the
time or difficulty of servicing the product.
This warranty excludes replacement of fuses and damage to the product from the use of
improper fuses. The maximum allowable fuse rating is 3 amps (10 amps for DC24V/240W
output). Lower ratings may be used for improved protection.
2. Safety
This product has been designed to be safe and simple to operate. As with any electronic
equipment, you must observe standard safety procedures to protect both yourself and the
equipment.
To Prevent Injuries:
do not apply voltage to a terminal that exceeds the range specified for that terminal.
do not operate this product when wet.
do not operate this product in an explosive atmosphere.
To Prevent Product Damage:
Do not operate this product from a power source that applies more than the voltage specified.
Do not operate this product from an injection signal input that mismatches the setting.
Do not operate this product from a solenoid valve where its power source mismatches the
gate output type setting.
3. Specifications
Power requirements: AC85~265V, 50/60Hz

Page | - 2 -© Page | - 2 - © Copyright Mastip Technology Limited. Information subject to alteration. V2.0 www.mastip.com
Sequential Injection Controller SC8
Injection signal input (Selected by JP1 on PCB): DC24V/AC220V
Gate output
1) DC24V (50W or 240W for total 8 gates)
2) AC220V (less than 100mA per gate, the voltage is the controller’s power
source) , total 8 gates
Operating mode: Mode A, Mode B or Mode AB
Time range: 0~999s, 0.0~99.9s, or 0.00~9.99s
Operating condition: 0℃~55℃(32℉~131℉), 10~80% (non-condensing)
Storage temperature: -20℃~70℃(-4℉~158℉)
4. Faceplate
1) Gate number: Gate1~Gate8.
2) Delay time display: Shows delay time of corresponding gate; green.
3) Open time display: Shows open time of corresponding gate; red.
4) Gate indicator: Corresponding gate is selected.
5) DC24V output light:DC24V output is selected.
6) AC220V output light:AC220V output is selected.
7) Injection signal input indicator: Indicates the state of injection input signal.
8) MODE key: Used to select operating mode & time range
MODE indicator: Mode key is selected
9) OPEN key: Used to open all gates or the gate selected manually.

Page | - 3 -© Page | - 3 - © Copyright Mastip Technology Limited. Information subject to alteration. V2.0 www.mastip.com
Sequential Injection Controller SC8
OPEN indicator: Open key is selected.
10) & 14) Up & Down arrow: Used to select gate for setting operating mode, time range and
open gates manually; used to change the number for setting delay & open time.
11) & 12) Left & Right arrow: Used to select operating mode or time range if mode key is
selected; used to select the time display unit for setting delay & open time.
13) Enter key: Used to finalize setting or exit the gate selected.
15) Power key: Used to turn on/off the controller.
Power indicator: Blinks after connected power and lights after the controller is turned on.
16) Operating mode indicator: Indicates the operating mode of corresponding gate.
5. Injection Signal Input Setting
Caution: Please set the jumpers JP1(on PCB)correctly. Otherwise, it may damage the
controller.
JP1 setting for Switch Input JP1 setting for DC24V/AC220V Input
6. Gate Output Setting
Caution: Please set the band switch (covered by a panel) on the side of the product correctly.
Otherwise, it may cause the controller or solenoid valve damaged.
Comment: The band switch on the product is one of the following. Please specify which is
required at time of order)
7. Operating Mode
Mode A:

Page | - 4 -© Page | - 4 - © Copyright Mastip Technology Limited. Information subject to alteration. V2.0 www.mastip.com
Sequential Injection Controller SC8
1) When the controller receives the injection signal (t1), delay time begins.
2) The controller counts down the delay time and displays it on DEL display unit.
3) At the end of delay time, the controller opens the gate output, counts the open time and
shows it on OPEN display unit.
4) The controller keeps the gate output open until the injection signal is off (t2).
5) When the injection signal is off, the controller resets the delay time and shows it on DEL
display unit. And the counted open time is showed on OPEN display unit until the next
injection signal comes on.
6) If the injection signal is off before the delay time passed, the controller will reset the delay
time and wait for the next injection signal.
Mode B:
1) When the controller receives the injection signal (t1), delay time begins
2) The controller counts down the delay time and displays it on DEL display unit.
3) At the end of delay time, the controller opens the gate output, counts the open time and
shows it on OPEN display unit.
4) At the end of open time, the controller closes the gate output.
5) When the injection signal is off (t2), the controller resets the delay time & open time, and
shows them on DEL & OPEN display units.
6) If the injection signal is off before the delay time passed, the controller will reset the delay

Page | - 5 -© Page | - 5 - © Copyright Mastip Technology Limited. Information subject to alteration. V2.0 www.mastip.com
Sequential Injection Controller SC8
time and wait for the next injection signal.
7) If the injection signal is off before the open time passed, the controller will close the gate
output, and reset the delay time & open time.
Mode AB:
1) When the controller receives the injection signal (t1), the indicator A is lit up and delay
time1 begins.
2) The controller counts down the delay time1 and displays it on DEL display unit.
3) At the end of delay time1, the controller opens the gate output, counts the open time1 and
shows it on OPEN display unit.
4) At the end of open time1, the controller closes the gate output.
5) Then the indicator B is lit up and delay time2 begins.
6) At the end of delay time2, the controller opens the gate output, counts the open time2 and
shows it on OPEN display unit.
7) At the end of open time2, the controller closes the gate output.
8) When the injection signal is off (t2), the controller resets the delay time & open time, and
shows delay time 1 & open time 1 on DEL & OPEN display units.
9) If the injection signal is off before the delay time1 passed, the controller will reset the
delay time and wait for the next injection signal.
10)If the injection signal is off before the open time1 passed, the controller will close the gate
output, and reset the delay time and open time.
11) If the injection signal is off before the delay time2 passed, the controller will reset the
delay time and open time, then wait for the next injection signal.
12) If the injection signal is off before the open time2 passed, the controller will close the
gate output, and reset the delay time and open time.

Page | - 6 -© Page | - 6 - © Copyright Mastip Technology Limited. Information subject to alteration. V2.0 www.mastip.com
Sequential Injection Controller SC8
8. Operation
Power on
1) Before powering on the controller, please confirm the connections are correct, the input
setting matches the injection signal, the output type matches the solenoid valve, and the
power source matches the voltage specified.
2) Switch on the power source, the power indicator blinks.
3) Press the POWER key for 3s to turn on the controller, the power indicator lights.
4) Check the display units and the indicators state to confirm the controller is ok and the
setting is required is correct.
Power off
Press the POWER key for 3s to turn off the controller, the power indicator blinks.
Select operating mode or shut off the gate selected
1) Press MODE key for 4s, MODE indicator and the gate indicator of gate1 blinks.
2) Press <or >to select the operating mode of gate1.
Both A&B indicators blinking indicates AB mode, and both A&B going off means to shut off
this gate.
3) Press ∧or ∨to select the gate and repeat step 2).
At the same time, the operating mode setting is saved.
4) Press ENTER key to save the setting and exit the procedure.
Select time range
1) Press ∧or ∨to select the gate, corresponding gate indicator blinks.
2) Press MODE key for 4s, MODE indicator blinks and the selected gate DEL display unit
shows “UnI”, OPEN display unit shows “9.99” or “99.9 or “999””.
3) Press <or >to select the time range of this gate.
4) Press ∧or ∨to select the gate and repeat step 3).
At the same time, the time range setting is saved.
5) Press ENTER key to save the setting and exit the procedure.
Set delay time and open time
1) Press <or >to set delay or open time, the corresponding display unit blinks.
Note: In the AB Mode, when the indicator A blinks, you can set the first group of delay & open time, and
when the indicator B blinks, you can set the second group of delay & open time.
2) Press ∧or ∨to change the number, the blinking digit can be modified.
Press <or >to select the blinking digit.
3) Press <or >to select the delay or open time and repeat step 2).
At the same time, the time setting is saved.
4) Press ENTER key to save the setting and exit the procedure.

Page | - 7 -© Page | - 7 - © Copyright Mastip Technology Limited. Information subject to alteration. V2.0 www.mastip.com
Sequential Injection Controller SC8
If there’s no operation in 4s during the setting procedure, the controller will exit the
procedure without saving automatically.
Open all gates output manually
Press OPEN key and hold on, the OPEN indicator lights and the controller open all gates
output (gate indicator lights) until the OPEN key is released.
Open the selected gate output manually
1) Press ∧or ∨to select the gate, the corresponding gate light blinks.
2) Press OPEN key and hold on, the OPEN indicator lights and the controller open the selected
gate output (gate indicator lights) until the OPEN key is released.
9. Default Setting
No. Name Default Setting
1 Gates in shut off state No
2 Injection signal input DC24V or Customized
3 Gate output type DC24V or Customized
4 Operating mode Mode A
5 Delay time 5.0 s
6 Open time 6.0s
7 Time range 0.0~99.9s
10. Wiring