Matsusada Precision AMP Series User manual

Ultra High Speed HV Amplifier
AMP series is an ultra high speed high voltage amplifier. It
realizedasfastas700V / µsevenwithload,andapproximately
2 times faster than existing models. With the capability of
peak current output of 3 times, it suppress the distortion of
waveform when with capacitive load.
AMP series
peak current
output range*
DC output range*
*Output rms must be
within 10mA
(Example : AMP-10B10)
Iout
t u o Vt u o V -
-Iout
30mA
+10kV-10kV -5
-5
5
5
0
10
20
-10
-20
-30
A
2
w
Vcon-in
32kV
Vout
Ch1 Freq
1.250kHz
Ch2 Ampl
40.68kV
:32.0kV
@
:16.0kV
:38.0μs
@
:50.0μs
Ch1
20.0V M 100μs
Ch2
10.0kV A Ch1 0.00V
T 10.20%
40μs
Suitable for the trend to higher
voltage for cell / panel evaluation
Additional output ranges for solar battery panel evaluations!
When the voltage at load is lower than the rated maximum output
of AMP series, constant voltage and high speed operation is possible
by sinking the output current with current sink feature.
As example of solar battery application, cell / panel voltage and
current data can be obtained by logging the change of current sink
by changing the voltage to solar battery cell / panel gradually. At
that time with its high slew rate of 300v / µs AMP can get more
detailed sampling. AMP is a bi-polar power supply with 0 crossing,
and so, it can measure the output short current at 0V. Moreover, it
can output peak current of 3 times more than rated current(at DC).
(see right chart)
Voltage rating required for solar battery(panel) evaluation is getting
higher and higher. AMP series added more lineups raging from ±600V
to ±30kV to meet the demand for evaluation of higher voltage solar
battery panel as well as evaluation of cell / panel with wider output
range.
Slew rate with actual load is as high as 700v / µs, and solve the
problem of "When actual operation with load, the response
become slow."
Ideal for higher speed printer or material evaluation testing.
Example of waveform : model AMP-20B20
Operation condition : Vcon-in=±10V Vout=±20kV
RL=1MΩF=1.25kHz
Slew rate: SR=32kV / 40µs > 700V / µs
For measuring voltage and / or current
*Change model to model
•Solar battery panel evaluations •Beam deflection
•Corona discharge •Electrostatic chuck
•Electrophotography process •Breakdown voltage testing
•Electroviscocity fluid •Lighting discharge tube
•Various electrostatic testing
APPLICATION
OUTPUT RANGE
High speed response of slew rate 700V/µs *
VOLTAGE RISE WAVEFORM

Input voltage / current
Output voltage
control
DC Bias
Regulation
Ripple
Stability
DC output voltage display
Output voltage monitor
Output current monitor
Remote switch ON/OFF
Protection
Operating Temp.
Storage Temp.
Humidity
Accessories
230VAC±10% 50 / 60Hz single phase 8Atyp(AMP-0.6B2000, AMP-1B1200)
230VAC±10% 50 / 60Hz single phase 5Atyp(AMP-2B200, AMP-5B80, AMP-10B40, AMP-20B20, AMP-30B10)
200V to 240VAC ±10% 50 / 60Hz single phase 10Atyp(AMP-40B20)
100V to 240VAC ±10% 50 / 60Hz single phase 3.5Atyp@100VAC(AMP-10B10)
External control voltage Vcon-in = -10V to +10V *1
(Input Impedance greater than 10k)
Front panel 10-turn potentiometer enables setting between
-
100% and +100%
Line : ±0.05%(115V or 230V ±10% input change)
Load : 0.05%(10% to 100% load change) *2
Less than 0.02% +1Vp-p *2
0.016% / Hr typ *2
3.5-digit digital meter *3
-10V to +10V from front panel BNC terminal
(Output impedance 1k)
-10V to +10V(10Vpeak) from front panel BNC terminal
(Output impedance 1kUp to 3kHz bandwidth)
Output ON / OFF with external contact signal
(Short : ON, Open : OFF)
Over current protection with cut off, over voltage protection
output short circuit protection, arc protection and blackout protection.
0°C to +40°C
-20°C to +60°C
20 to 75%RH(no condensation)
Input AC cable 2.5m (1)
With 3-pin connector for 115VAC input Flying lead(open end) for 230VAC input
Output HV cable flying lead 1.5m (1)
Instruction Manual (1)
LINEUP
SPECIFICATIONS
-
600V to +600Vdc
-
1kV to +1kVdc
-
2kV to +2kVdc
-
5kV to +5kVdc
-
10kV to +10kVdc
-
20kV to +20kVdc
-
30kV to +30kVdc
-
40kV to +40kVdc
Output Voltage
1200W
1200W
400W
400W
100W
400W
400W
300W
800W
Max.
output power
Output Current (DC+AC) MODEL
Frequency Response(
-
3db)*1
Slew Rate Full scale Small bandwidth
(10% of full scale)
±10mA max and
±30mApk 1mS max
±40mA max and
±120mApk 1mS max
±20mA max and
±60mApk 1mS max
±2000mA max and
±4000mApk 1mS max
±1200mA max and
±2400mApk 1mS max
±200mA max and
±400mApk 1mS max
±80mA max and
±160mApk 1mS max
±10mA max and
±30mApk 1mS max
±20mA max and
±40mApk 1mS max
AMP-0.6B2000
AMP-1B1200
AMP-2B200
AMP-5B80
AMP-10B10
AMP-10B40
AMP-20B20
AMP-30B10
AMP-40B20
700V / µs
300V / µs
360V / µs
DC to 40kHz
DC to 30kHz
DC to 20kHz
DC to 10kHz
DC to 7kHz
DC to 4kHz
DC to 1kHz
DC to 1kHz
DC to 60kHz
DC to 50kHz
DC to 50kHz
DC to 30kHz
DC to 25kHz
DC to 20kHz
DC to 5kHz
DC to 5kHz
*1 Offset voltage at Vcon-in = 0V is less than
0.1% of rated output.
*2 At DC operation with resistive load maximum
rated output.
*3 At DC output : DC voltage display. At more
than 10Hz output : Average voltage display
*2
*3
*1 Typical value at sine wave operation with
resistive load.
*2 At frequency of full scale, output voltage
may be clipped by power limitation.
*3 CE marking model corresponds to low
voltage directive.

AMP series
DIMENSIONS inch(mm)
ON/OFF
REMOTEVmoniImoni
HIGHVOLTAGEAMPLIFIER
BIASONVcon-in
HV
POWER
I
O
O
POWER
I
HV
HIGHVOLTAGEAMPLIFIER
ONVcon-in BIAS Imoni Vmoni
ON/OFF
REMOTE
18.31(465)
18.31(465)
19(483)
19(483)
18.31(465)
19(483)
16.81(427)
0.2
(5)
1.38
(35)
0.79
(20)
17.17(436)
Vmoni REMOTE
ON/OFF
HIGHVOLTAGEAMPLIFIER
ImoniBIASONVcon-in
O
I
POWER
HV
OUTPUT
18.82
(478)
4
(101.6)
5.91
(150)
5.91
(150)
6.97
(177)
0.59(15)
8-0.24x0.39
(6x10)
8-0.24x0.39
(6x10)
12-0.24x0.39
(6x10)
12-0.24x0.39
(6x10)
11 12
10 13
1 2 3 4 5 6 7 8 9
10.47
(266)
24.49
(622)
14
(355)
19(483)
18.31(465)
4
(101.6)
1.5
(38)
1.5
(38)
3
(76.2)
4
(101.6)
3
(76.2)
4
(101.6)
3
(76.2)
1.77
(45)
3
(76.2)
3
(76.2)
0.23
(5.95)
1.75
(44.45)
4
(101.6)
4
(101.6)
4
(101.6)
11
Have priority to all other
operations for safety reason.
To be also used to reset output
cutoff status due to output over
load,
output short circuit protection
or black
out protection.
Remote switch operation is possible
only when output switch is on.
BNC receptacle
10-turn potentiometer
BNC receptacle
BNC receptacle
BNC receptacle
M6
POWER ON / OFF switch
HV ON / OFF switch
OUTPUT voltage meter
External control voltage
(Vcon-in)input connector
Bias ON/OFF switch
Bias setting dial
OUTPUT current monitor
terminal
OUTPUT voltage monitor
terminal
Remote ON/OFF terminal
OUTPUT connector
Ground terminal
FUSE
AC inlet
1
2
3
4
5
6
7
8
9
10
11
12
13
AMP-10B10
D=19.06(484)*
Weight : 23kg approx.
AMP-30B10
D=21.65(550)*
Weight : 50kg approx.
AMP-2B200, AMP-5B80
AMP-10B40, AMP-20B20
D=21.65(550)*
Weight : 28kg approx.
AMP-0.6B2000
D=24.02(610)*
Weight : 45kg approx.
*Except projection
*Except projection
*Except projection
*Except projection
BIAS Imoni Vmoni REMOTE
ON/OFF
Vcon-in ON
HIGHVOLTAGEAMPLIFIER
O
I
POWER
HV
AMP-1B1200
D=24.02(610)*
Weight : 50kg approx.
0.59(15)
0.59(15)
0.59(15)

INPUT / OUTPUT CABLE
OPTION
*Except projection
-LN
-L(5m)
Adjustable cut-off current setting value *
Limit setting value to trigger to cut off the output current becomes variable by adjusting the potentiometer
on the front panel between the range 10% to 105% of the rated current.
Current limit *
Output current will not be cut off but will be regulated by lowering the output voltage at a occurence of overcurrent.
Variable current limit *
Output current will not be cut off but will be regulated by lowering the output voltage at a occurence of overcurrent.
The setting value to trigger to regulate the output current becomes variable by adjusting the potentiometer
on the front panel between the range 10% to 105% of the rated current.
Cancellation of blackout protection
HV output cable 5m (more than 1kV models except AMP-30B10 and AMP-40B20)
Please note that using 5-meter long cable may decrease slew rate, response time, and distort output waveforms.
Please see “Capacitive load” for details.
Input cable
* These options cannnot be selected together. Need to be selected either one.
When ordering, suffix -L mark(option mark) to the model number.
<e.g.> AMP-10B10-LCN(5m), AMP-2B200-LNOc(5m)
The length is 2.5m for both.(Please see CABLE series catalog for details)
*CABLE TYPE 3 is needed separately when the input voltage is 200V to 240VAC.
Output cable
800V to 10kV models
CN-40-AHVP HV output cable 1.5m (standard)
CN-40-AHVP(5) HV output cable 5m (-L(5m) option)
AMP-20B20
CN-40-AHVP TU* HV output cable 1.5m (standard)
CN-40 AHVP TU(5)* HV output cable 5m (-L(5m) option)
AMP-30B10, AMP-40B20
CN-50-AHVP HV output cable 3m (standard)
Less than 600V models
using terminal board output line 1.5m (standard)
*TU : With silicon tube
-LOc
-LC
-LCc
Inlet type / Flying lead / 250V rated /
Single phase(3-core) / Black
CABLE TYPE 3 (Standard)
[300W and 400W models] [800W,1200W models]
CABLE TYPE 5 (Standard)
M4 roand terminal×3 / Flying lead /
250V rated /Single phase(3-core) / Black
23.23 (590)
48.03
(1220)
23.62 (600)
AMP-40B20
Weight : 160kg approx.
[AMP-10B10]
CABLE TYPE 1 (Standard)*
3-pin plug(Type-A) / Inlet type / 125V rated /
Single phase(3-core) / Black

Customer Inquiry Sheet
Please copy this page and above fax number after filling out form below.
A quotation
Other ( )
An explanation of product A demonstration To purchase
Address:
Company:
Dept.: Title:
Fax:
Name:
Tel:
E-mail:
Give us your requirement / comment
I would like
Please fill in below.
USA/Canada
USA/Canada
:
:
+
+
1-888-652-8651
1-888-652-8651
other countries
other countries
:
:
+81-6-6150-5089
+81-6-6150-5089
FAX
FAX
01.047.09 6C
We warrant the specification, unless otherwise specified, at max. rated output after warm up, and scope of application is between 10% and 100% of max. rated output. We warrant that products
contained in this catalog (hereinafter, the “Products”) are free from defects in material and workmanship under normal use for a period of one (1) year from the date of shipment thereof. However,
the warranty period for X-ray detectors and X-ray source shall be either one (1) year from the date of shipment or 1,000 hours, whichever shorter. The above warranty shall not apply to any
Product which, at our sole judgment, has been: i) Repaired or altered by persons unauthorized by us; or ii) Connected, installed, adjusted or used otherwise than in accordance with the
instructions furnished by us (including being used in an inappropriate installation environment, such as in corrosive gas, high temperature and humidity). We are not liable for any loss, damage or
failure of the Products after the shipment thereof caused by external factors such as disasters. We will not inspect, adjust or repair any of our power supply products in the field or at any customer
site. If you suspect that there has been a power supply failure in the field, please inspect your whole unit by yourself in an effort to determine that the problem is, in fact, arising out of our power
supply products. If it is found that the problem is arising out of such power supply product after inspection, please contact your local sales office for additional troubleshooting. A “Return Merchan-
dise Authorization” is required in case the power supply must be sent back to the factory in Japan for inspection and repair. We, at our sole discretion repair or replace such defective products at
no cost to the purchaser. We assume no liability to the purchaser or any third party for special, incidental, consequential, or other damages resulting from a breach of the foregoing warranty. This
warranty excludes any and all other warranties not set forth herein, express or implied, including without limitation the implied warranties of merchantability or fitness for a particular purpose. The
Products are not designed and produced for such applications as requiring extremely high reliability and safety, or involving human lives (such as nuclear power, aerospace, social infrastructure
facility, medical equipment, etc.). The use under such environment is not covered by this warranty and may require additional design and manufacturing processes. No modification or supplement
of this warranty shall be binding unless in writing and signed by a duly authorized officer of Matsusada. Matsusada reserves the right to make any changes in the contents of catalogs or specifica-
tions at any time without advance notice. Due to compelling reason such as unavailability of components used, products might be un available or unable to repair. The products specified in
catalogs or specifications are designed for use by the person who has enough expertise or under the control of such person, and not for general consumers. Schematics of products shall not be
submitted to users. Test result or test data for the products shall be available upon request with charge.
Make sure you read the specification in the latest catalog before you order. Contact nearby sales office for the latest catalog.
PLEASE SEE THE LINK BELOW FOR THE COMPLETE WARRANTY TERMS
http://www.matsusada.com/site/warranty.html
Manufacturer warranty
Website
San Jose Office
:
2570 N.First Street Suite 200 San Jose, CA 95131
Tel: +1-408-273-4573 Fax: +1-408-273-4673
Boston Office
:
859 Willard Street, Suite 400, Quincy, MA 02169
Tel: +1-781-353-6407 Fax: +1-781-353-6476
International Office
:
Osaka-City, Osaka Japan
Tel: +81-6-6150-5088 Fax: +81-6-6150-5089
Headquarters
:
745 Aoji-cho Kusatsu Shiga 525-0041 Japan
5960 Fairview Rd. Suite 400, Charlotte, NC 28210
Tel: +1-704-496-2644 Fax: +1-704-496-2643
North Carolina :
Office
www.matsusada.com
Other manuals for AMP Series
1
This manual suits for next models
9
Table of contents