Intended use MX-RFSG1800
The device is a highly integrated RF signal/sweep generator specifically
designed for Cable Telecommunication Technicians working in the HFC
environment. Its small size, portability and battery power can easily assist
the technician to quickly identify network issues when performing network
bandwidth upgrades, equipment, or plant performance and proofing.
By injecting this signal source into the plant with this device, it allows the
user to insert RF signals at higher frequencies (up to 1800 MHz). This allows
the technician the opportunity to verify and validate the coax and
passives downstream are capable of properly passing higher frequencies.
This allows the technician to “Proof” the network by recording the signal
performance at the end of line. The device also provides an excellent
solution for troubleshooting missed or defective network equipment, or
other anomalies such as “suck-outs”, “roll-off”, and other signal ailments
and impairments.
1. RF output 4. Directional keys (up, down, left, right)
2. LCD Screen 5. OK (To Confirm)
3. Power on/off 6. Return (Escape)
PWR Power on/off. Press 3 seconds to power off.
OK Confirm the current operation. To save changes, select "START" then press OK key.
RETURN When changed prior to pressing “START", pressing “RETURN” will return to previous settings.
▲▼ Move cursor up/down or change frequency.
◀▶
Move cursor right/left or change options of current menu item.
Mode 2 Single
Frequency Single Frequency Output,700-1800MHz
Attenuator 0, 5, 10 attenuation selection
Shutdown Time: Never, 10mins, 30mins
START When settings are modified ,select button “START” then
press OK key to save the changes. Device will start to
transmit RF signal with this command
STOP When selecting “STOP”, then pressing “OK”, device will
stop RF signal transmitting.
Mode 1 Sweep
Start Freq Start frequency, 700-1800MHz
End Freq End frequency, 700-1800MHz
Step Freq Step Frequency, select 1/3/6/9/12MHz
Interval Output dwell time,100~1000ms
Repeat Once or Repeat, scan once or repeatedly
Attenuator 0,5,10 attenuation selection available
START When settings are modified ,select “START”
and press OK key to save the changes. Device will
start to transmit RF signal with this command
STOP When selecting “STOP”, press OK key, device will stop
signal transmitting RF.