Maxey Moverley Limited, 6 Broad Ground Road, Lakeside, Redditch, Worcestershire, B98 8YP
Tel: 01527 522299 ● Fax: 01527 522588
Date: 28/03/2013 | Page 2
Quick Reference Guide
1. Introduction
This guide provided y Maxey Moverley Limited contains programming instructions to aid onsite
engineers in tackling common pro lems when installing Dedicated Micros 2060 cameras.
This information has een compiled from pu licly availa le documentation in conjunction with the
o servations of Maxey Moverley Limited.
1.1. Description
The Dedicated Micros 2060 camera is a precision unit, offering a wide varia le speed range, together
with a large pre-set memory for positions, tours and alarm responses.
The Dedicated Micros 2060 Camera has a num er of features which can e selected y the System
Supervisor when the dome is installed. Any of these can e altered su sequently, or cancelled
altogether, to give the est operational responses for any particular application. They are invoked or
cancelled through on-screen menu structures and the settings are then retained in non-volatile
memory so that they are not affected y a loss of power.
2. Connections
The type 2060 external connections are via an IP66 Amphenol connector with 3 metre composite
ca le flying lead comprising co-ax, power pair & RS485 pair. This lead should e connected to the
oxed P.S.U. supplied with the dome (can e extended to 30 metres max. in length) The connections
are as follows:
Red Wire 24 V AC live
Blue Wire 24 V AC neutral
Yellow Wire R.S. 485 ‘A’
Green Wire R.S. 485 ‘B’
Coax Screen BNC screen
Coax Signal BNC centre pin
The co-ax and power wires are always connected, the RS 485 wires are only connected when an
external protocol converter is fitted or an RS485 controller is eing used.