Quick Reference Guide
VCL Or iter Gold/Lite
VCL Or iter Gold/Lite
Quick Reference Guide
Contents
1. INTRODUCTION 2
2. INSTALLATION 2
2.1 Ceiling and Wall Mounted Models 2
3. SETTING UP THE ORBITER GOLD/LITE 4
3.1 Wiring Details 4
3.2 Ta le 1 – VC408 Terminal Block PCB 4
3.3 Ta le 2 – Pin Descriptions of Pin Outs for False Ceiling 5
4. SETTING ON THE TOP BOARD 5
5. ADDRESS SETTINGS 6
6. COAX TELEMETRY 7
7. ALARM SETTINGS 7
8. TECHNICAL SUPPORT HELPLINE 5
9. REVISION HISTORY 6

Maxey Moverley Limited, 6 Broad Ground Road, Lakeside, Redditch, Worcestershire, B98 8YP
We : www.cctvrepairs.com ● Email: [email protected]
Tel: 01527 522299 ● Fax: 01527 522588
Issue 1.1 | Page 2
Quick Reference Guide
VCL Or iter Gold/Lite
1. Introduction
This guide provided y Maxey Moverley Limited contains programming instructions to aid onsite
engineers in tackling common pro lems when installing Or iter Gold/Lite cameras.
This information has een compiled from pu licly availa le documentation in conjunction with the
o servations of Maxey Moverley Limited.
2. Installation
2.1 Ceiling and Wall Mounted Models
Figure 1. Below, details the ceiling and wall mount rackets, including dimensions.
Step 1
Attach the racket (wall or ceiling type) using fixings which are appropriate for the surface and a le
to support the weight of the Or iter Gold/Lite (1.1kg) as shown in Figure 2.
Figure 2. Push up pole – Align to lug slot.

Maxey Moverley Limited, 6 Broad Ground Road, Lakeside, Redditch, Worcestershire, B98 8YP
We : www.cctvrepairs.com ● Email: [email protected]
Tel: 01527 522299 ● Fax: 01527 522588
Issue 1.1 | Page 3
Quick Reference Guide
VCL Or iter Gold/Lite
Step 2
Align the lug on the Or iter Gold/Lite with the slot on the racket. Carefully push the Or iter
Gold/Lite into the racket and twist clockwise. Allow to drop into the retainer, see Figure 2.
Figure 3. Fitting the Or iter Gold/Lite into the racket
Step 3
Fit the M3 CSK safety locking screw into the racket to lock the Or iter Gold/Lite in place. This is
ESSENTIAL for the safe operation of the Or iter Gold/Lite. (The hole for the screw is on the opposite
side of the pole to the slot.)
Step 4
Attach the ca le cover. This is supplied in two halves which snap together over the neck of the
Or iter Gold/Lite as shown in Figure 4, elow.
Figure 4. Fitting the Ca le Covers.

Maxey Moverley Limited, 6 Broad Ground Road, Lakeside, Redditch, Worcestershire, B98 8YP
We : www.cctvrepairs.com ● Email: [email protected]
Tel: 01527 522299 ● Fax: 01527 522588
Issue 1.1 | Page 4
Quick Reference Guide
VCL Or iter Gold/Lite
3. Setting up the Or iter Gold/Lite
3.1 Wiring Details
The Or iter Gold/Lite is designed for speed of installation and set up and so the wall and ceiling
mount rackets are supplied pre wired. Customer wiring is via an internal terminal lock PCB which
is located inside the ase plastic cover.
Note: The terminal lock is accessed y removing the two M3 CSK head screws, using appropriate
tool.
Figure 5. Mounting options for Or iter Gold/Lite
Figure 6. Terminal lock details
3.2 Ta le 1 – VC408 Terminal Block PCB
TWISTED PAIR ‘DATA IN COAX’
SG
(Not Used)
SG
(Not Used)
SYN
(Not Used)
SYN
(Not Used)
D+
Twisted Pair Telemetry
D+
(Not Used)
D-
D
-
(Not Used)
VID
Video Signal
VID
Video Signal
VG
Video Ground
VG
Video Ground
+V (AC)
24V AC
+V (AC)
24V AC
0V (AC)
24V AC
0V (AC)
24V AC

Maxey Moverley Limited, 6 Broad Ground Road, Lakeside, Redditch, Worcestershire, B98 8YP
We : www.cctvrepairs.com ● Email: [email protected]
Tel: 01527 522299 ● Fax: 01527 522588
Issue 1.1 | Page 5
Quick Reference Guide
VCL Or iter Gold/Lite
Figure 7. Wiring details for the Or iter Gold/Lite (False cealing mount)
3.3 Ta le 2 – Pin Descriptions of Pin Outs For False Ceiling
TWISTED PAIR ‘DATA IN COAX’
Pin 1
Green
24V AC
Pin 1
Green
24V AC
Pin 2
Red
24V AC
Pin 2
Red
24V AC
Pin 3
Blue
Data +
Pin 3
Blue
Pin 4
Yellow
Data
-
Pin 4
Yellow
Pin 5
Coax Screen
Video Ground
Pin 5
Coax Screen
Video Ground
Pin 6
Coax Core
Video Signal
Pin 6
Coax Core
Video Signal
Pin 7
(Not Used)
Pin 7
(Not Used)
4. Settings on the Top Board
Figure 8. The Or iter Gold/Lite top oard

Maxey Moverley Limited, 6 Broad Ground Road, Lakeside, Redditch, Worcestershire, B98 8YP
We : www.cctvrepairs.com ● Email: [email protected]
Tel: 01527 522299 ● Fax: 01527 522588
Issue 1.1 | Page 6
Quick Reference Guide
VCL Or iter Gold/Lite
LED D17 will illuminate if the receiver that is eing controlled y Coax telemetry is selected y the
transmitter and the coax telemetry is satisfactory. If the receiver is eing controlled y twisted pair
telemetry, LED D17 will flash whenever a valid telemetry command is received.
VR1 (LIFT) and VR2 (GAIN) are factory set. They are designed to improve the picture quality
transmitted y the Or iter Gold/Lite when long ca le runs are involved and a degradation of picture
quality occurs. Before adjusting either the LIFT or GAIN, ensure that the iris is correctly adjusted.
If the image is ‘smearing’ due to a long ca le run, then the LIFT pot may e adjusted to sharpen the
image. If the contrast of the image is low, (caused y an attenuated video signal), make adjustments
y turning the GAIN pot.
Note. Over adjustments of either the GAIN or the LIFT pot will result in further image quality
degradation.
5. Address Settings
The addresses for each Or iter Gold/Lite are set as shown in the ta le elow. Set the poles on
DILSW2 to the desired position for each address.
Figure 9. Address Settings

Maxey Moverley Limited, 6 Broad Ground Road, Lakeside, Redditch, Worcestershire, B98 8YP
We : www.cctvrepairs.com ● Email: [email protected]
Tel: 01527 522299 ● Fax: 01527 522588
Issue 1.1 | Page 7
Quick Reference Guide
VCL Or iter Gold/Lite
6. Coax Telemetry
Coax telemetry Or iter Gold/Lites do not require an address setting, therefore the settings of
positions 1-7 on DILSW2 are ignored. Position 8 controls the alarm feature.
7. Alarm Settings
Switch 8 of the 8 way DIL switch DILSW2 is used to toggle the Or iter Gold/Lites alarm setting. When
the switch is ‘ON’ the Or iter Gold/Lites alarm inputs are ena led and set to the default settings as
shown in the ta le elow. If switch 8 is ‘OFF’ then the alarms are not automatically ena led, ut can
e ena led and adjusted using a MaxCom with local alarm menus.
ALARM
INPUT
-
T PE
PRESET
TIME
-
OUT
1
Normally Open
1
10 Seconds
2
Normally Open
2
10 Seconds
3
Normally Open
3
10 Seconds
4
Normally Open
4
10 Seconds

Maxey Moverley Limited, 6 Broad Ground Road, Lakeside, Redditch, Worcestershire, B98 8YP
We : www.cctvrepairs.com ● Email: [email protected]
Tel: 01527 522299 ● Fax: 01527 522588
Issue 1.1 | Page 8
Quick Reference Guide
VCL Or iter Gold/Lite
8. Technical Support Helpline
For help and guidance with installation issues, that are not covered within this guide please contact
our dedicated customer technical helpline on 01527 522299 and speak to one of our specially
trained technicians will who will e happy to assist you.

Maxey Moverley Limited, 6 Broad Ground Road, Lakeside, Redditch, Worcestershire, B98 8YP
We : www.cctvrepairs.com ● Email: [email protected]
Tel: 01527 522299 ● Fax: 01527 522588
Issue 1.1 | Page 9
Quick Reference Guide
VCL Or iter Gold/Lite
9. Revision History
Revision
Date
Author
Amendments
Comments
1 24/04/13 DS First draft Issued for internal review
1.1 14/05/2013 DS Agreed format/content Issued for distribution