UC 200 IR
This product complies with EMC requirements in accordance with Directives
2004/108/CE and subsequent amendments
and reference to Applied Regulation EN ISO 14982
Manufacturer
: MC elettronica S.r.l.
Address
: Via E. Fermi, 450/486
Fiesso Umbertiano (ROVIGO) - ITALY
Tel. +39 0425 754713 Fax +39 0425 741130
E-mail: [email protected]
Internet: www.mcelettronica.it
Manual code
: 1230-EN
Issued
: May 2012
Edition
: February 2020
MC elettronica S.r.l. is not obliged to give notice of any further modifications to the
product.
The Information provided in this manual does not allow unauthorised personnel to
tamper with the product in any way.
The guarantee on the equipment will no longer be valid if tampering should be
detected.
© Copyright MC elettronica 2020
2 LED for millesimal scale
3 LED for centesimal scale
4 Mechanical adjustment of the instrument
5 Function selector switch
6 Cycle LEDs
7 Delay end LED
8 Adjustment buttons

Installazione e uso 3
UC 200 IR
Index
1. Rules and general warnings ................................................................................ 4
1.1 Introduction....................................................................................................... 4
1.2 Terms of guarantee........................................................................................... 5
1.3 After-sales service............................................................................................. 5
2. Installation............................................................................................................. 6
3. Programming......................................................................................................... 7
4. Changing password.............................................................................................. 9

Printed in Italy
UC 200 IR
1. Rules and general warnings
1.1 Introduction
This manual gives all the specific information that you need for a proper use of the
equipment.
After buying the Speed indicator, read the manual carefully and refer to it any time
you have doubts on how to use the equipment or when you have to carry out
maintenance operations.
Keep the manual on the machine. If this is not possible, keep it ready at hand.
ALL RIGHTS RESERVED. THIS MANUAL IS INTENDED FOR CUSTOMERS ONLY. ANY
THE OTHER USE IS FORBIDDEN.

Installazione e uso 5
UC 200 IR
1.2 Terms of guarantee
•SUBJECT OF THE GUARANTEE: the guarantee is applied to the product and to
those parts which are marked with the serial number or any other identification
number used by MC elettronica;
•HOW LONG THE GUARANTEE IS EFFECTIVE: MC elettronica S.r.l.
guarantees the UC 200 IR Monitor for a period of 1 year from the
manufacturing date (printed on the identification label which is to be found on the
rear side of the equipment) and also accessories.
The guarantee covers the product and any repair carried out within the
agreed terms.
This guarantee does not apply in the event of:
•accidental damage;
•improper use;
•modifications which haven't been agreed upon, improper installation (or
setting);
•damage caused when a non-MC elettronica equipment, which is
mechanically and electrically connected to our instruments, breaks or does
not function properly;
•acts of God (lightning, floods, fire or any other causes which do not depend
on MC elettronica).
Repairs under guarantee, which must be carried out in the laboratories of our
authorized centres, are entirely free of charge provided the equipment is directly
transported to said laboratories or sent free port. Transport charges and risks are
entirely borne by the Customer.
The above-mentioned guarantee is valid unless otherwise stated between MC
elettronica and the Customer.
!
Warning
MC elettronica declines any liability for damage or direct or indirect
charges, as a consequence of improper use or inability of the Customer
to use the equipment separately and/or together with other instruments.
1.3 After-sales service
Service is available in all the countries where the computer is officially supplied by
MC elettronica (during and after the warranty period).
Any kind of operation that is to be carried out on the UC 200 IR Monitor must be
carried out in accordance with the instructions stated in this manual or as agreed with
MC elettronica.
If not, the relative terms of guarantee might become void.

Printed in Italy
UC 200 IR
2. Installation
UC 200 IR can work with the pressure transducer or litre counter sensor. To ensure
optimal operation in the pressure configuration for UC 200 IR and its related transducer
they should be installed near the support nozzle powered by a 12V battery, if the
transducer is installed away from the nozzle it is possible to compensate for its related
loss in pressure with a special programmable parameter, see chapter on Programming.
Selecting the type of sensor:
UC 200 IR is factory-set to work with a pressure sensor, to use a flow meter instead
you need to: open the device removing the 4 corner screws, removing the front panel
and moving the micro-switches as indicated in the following figure, then change the
relative software parameter (see chapter on Programming).
Configuration for
Pressure sensor
Configuration for
flow meter
Internal electronic board

Installazione e uso 7
UC 200 IR
3. Programming
To access the programming phase of the parameters keep the PRESS/bar pressed for
10 seconds, after which the monitor will request a password, the password usually
corresponds to a 4-digit number shown on the label behind the monitor.
Name of parameter
description
Range and step
default
Pr
Calibrating the pressure sensor, set the
maximum nominal value of the sensor
5 –30 at step of
1
20
dU
Nozzle diameter selected; each diameter
has a matching pressure
characteristic/pre-loaded flow; it is only
possible for the nozzle “P” to be
programmed, see below
6-8-10-12-14-16-
18-20-22-24-26-
28-30-32-34-36-
38-40-P
22
Flow rate at 5 Bar of the P nozzle: this
parameter is always required even if in the
previous parameter one of the standard
nozzles is selected, this parameter is
indicated by the arrow at the top left
0.0 –6500.0
step of 0.1
500.0
PC
Loss of head : the loss of head is
programmed in bars with a decimal,
between the assembly point of the
pressure sensor and the nozzle
0.0 –30.0 at
step of 0.1
0.0
In this case the password will be 1001: to input the first
digit use the m3/h and m3keys, to go to the next digit
press the Press button; if the password has been input
correctly, when pressing the Press button for the last
time, the monitor will go to programming the first
parameter, see the list below

Printed in Italy
UC 200 IR
Name of parameter
description
Range and step
default
i
Litre pulses for the flow meter
10.0 –999.9
step of 0.1
30.0
PF
Select work mode :
F = with flow meter
P = with a pressure transducer (to match
the choice of the sensor type described on
the previous page)
P or F
P
At the end of the parameters it is possible
to change the m3 counter totals, the
totalled current value will appear on the
display with the related arrow and the
flashing first digit : thus the value of the
digit can be changed or reset using the
same keys used to input the password
--
--

Installazione e uso 9
UC 200 IR
4. Changing password
The programming access Password can be changed in the following way : with the
monitor off (disconnected from the power supply) press all three keys simultaneously
and hold them down for about 10 seconds until the display shows “P----“, now release
the keys and input the new password, use the external keys to change the value of the
first digit and with the middle key go to the next digit.
Technical features
Power supply voltage
From 9 to 16 Vdc
Maximum absorption
60 mA @ 16Vcc (sensors excluded)
80 mA @ 16Vcc with pressure transducer (1)
Operating temperature
-20°C ÷ +75°C
IP Protection degree
IP65
Mechanical resistance
2 g
Material
ABS
( (1) = sample calculation 12V power battery : setting the hourly consumption at
80mA/h, setting 10 hours of daily work therefore 80*10=800mA daily, setting 30
consecutive working days thus 800*30=24A=24000mA
Therefore, if the sprayer worked consecutively for 1 month, consumption would be
24A. If you cannot connect UC 200 IR to the tractor battery it is advisable to use a
battery with at least twice the calculated value capacity, thus 48A: for example a
battery for small cars.

Printed in Italy
UC 200 IR
WARNING: THIS PRODUCT CONTAINS TIN AND LEAD. IT MUST BE
DISPOSED OF AT THE END OF ITS LIFE CYCLE AT THE
DESIGNATED DISPOSAL FACILITIES OR DELIVERED DIRECTLY TO
MC ELETTRONICA SRL (ITALY).

Installazione e uso 11
UC 200 IR
NOTES
Table of contents
Other MC Electronics Monitor manuals
Popular Monitor manuals by other brands

EverFocus
EverFocus EN-7517E instruction manual

Renkforce
Renkforce RF-SW-130 operating instructions

Hitachi
Hitachi 55HDX99/DW2-U Service manual

Siko
Siko MA501-S Additional to the Original Installation Instructions

Elo TouchSystems
Elo TouchSystems AccuTouch 821615-000 product manual

Samsung
Samsung QM43N Quick setup guide